At least 1,243 records · Page 69

Performance of a Multifunctional Space Evaporator- Absorber-Radiator (SEAR)

The Space Evaporator-Absorber-Radiator (SEAR) is a nonventing thermal control subsystem that combines a Space Water Membrane Evaporator (SWME) with a Lithium Chloride Absorber Radiator (LCAR). The LCAR is a heat pump radiator that absorbs water vapor produced in the SWME. Because of the very low water vapor pressure at equilibrium with lithium chloride solution, the LCAR can absorb water vapor at a temperature considerably higher than the SWME, enabling heat rejection by thermal radiation from a relatively small area radiator. Prior SEAR prototypes used a flexible LCAR that was designed to be installed on the outer surface of a portable life support system (PLSS) backpack. This paper describes a SEAR subsystem that incorporates a very compact LCAR. The compact, multifunctional LCAR is built in the form of thin panels that can also serve as the PLSS structural shell. We designed and assembled a 2 sq ft prototype LCAR based on this design and measured its performance in thermal vacuum tests when supplied with water vapor by a SWME. These tests validated our models for SEAR performance and showed that there is enough area available on the PLSS backpack shell to enable heat rejection from the LCAR.

Izenson, Michael G.↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash Radiography Studies with Microcolumnar CsI

There is growing interest in using low-energy flash x-ray sources in radiographic applications to provide high-contrast images of low-density objects. Due to the low-energy nature of the detected photons, thin bright scintillators are desired. In order to pursue an optimum radiographic system, experimental studies have been performed of the static imaging properties of thin microcolumnar CsI using a Platts x-ray source. The Platts source is a nominally 300 keV endpoint rod pinch diode x-ray source with a ~35 ns pulse time. The source was used to measure the imaging properties of microcolumnar CsI with various thicknesses and backings. The experimental setup was modeled in GEANT4, and the images were simulated to estimate system performance. Taking into account the source photon production, radiation transport, and system optical performance, an accurate assessment of the detection system can be deduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA’s Vision for Spaceflight Computing

Future NASA mission applications demand onboard computing performance, power efficiency, and flexibility not available from current products. To address these needs, NASA’s High Performance Spaceflight Computing (HPSC) project is developing a radiation hardened, general purpose multi-core processor. Key HPSC objectives include natural space radiation hardness, fault tolerance, computation performance and extensibility, and power scalability. This presentation will first highlight how advances in spaceflight computing are key to NASA’s envisioned future for advanced avionics. Descriptions will then be provided for NASA mission applications and use cases that demand advanced spaceflight computing. The presentation will then provide an overview of NASA’s HPSC project and how it will address the computational demands of future missions.

Wesley Powell↗

Measuring THz QCL feedback using an integrated monolithic transceiver.

THz quantum cascade lasers are of interest for use as solid-state local-oscillators in THz heterodyne receiver systems, especially for frequencies exceeding 2 THz and for use with non-cryogenic mixers which require mW power levels. Among other criteria, to be a good local oscillator, the laser must have a narrow linewidth and excellent frequency stability. Recent phase locking measurements of THz QCLs to high harmonics of microwave frequency reference sources as high as 2.7 THz demonstrate that the linewidth and frequency stability of QCLs can be more than adequate. Most reported THz receivers employing QCLs have used discrete source and detector components coupled via mechanically aligned free-space quasioptics. Unfortunately, retroreflections of the laser off of the detecting element can lead to deleterious feedback effects. Using a monolithically integrated transceiver with a Schottky diode monolithically integrated into a THz QCL, we have begun to explore the sensitivity of the laser performance to feedback due to retroreflections of the THz laser radiation. The transceiver allows us to monitor the beat frequency between internal Fabry-Perot modes of the QCL or between a QCL mode and external radiation incident on the transceiver. When some of the power from a free running Fabry-Perot type QCL is retroreflected with quasi-static optics we observe frequency pulling, mode splitting and chaos. Given the lack of calibrated frequency sources with sufficient stability and power to phase lock a QCL above a couple THz, attempts have been made to lock the absolute laser frequency by locking the beat frequency of a multimoded laser. We have phase locked the beat frequency between Fabry-Perot modes to an {approx}13 GHz microwave reference source with a linewidth less than 1 Hz, but did not see any improvment in stability of the absolute frequency of the laser. In this case, when some laser power is retroreflected back into the laser, the absolute frequency can be pulled significantly as a function of the external path length.

99 GENERAL AND MISCELLANEOUS↗

2D rad-MHD model assessment of designs for multiple-shell gas nozzles for Z.

AASC is designing multiple-shell gas puff loads for Z. Here we assess the influence of the loads initial gas distribution on its K-shell yield performance. Emphasis is placed on designing an optimal central jet initial gas distribution, since it is believed to have a controlling effect on pinch stability, pinch conditions, and radiation physics. We are looking at distributions that optimize total Ar K-shell emission and high energy (>10 KeV) continuum radiation. This investigation is performed with the Mach2 MHD code with non-LTE kinetics and ray trace based radiation transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical Properties of the Solar Atmosphere Derived from Comparison of Spectro-Polarimetric SDO/HMI Observables with 3D Radiative MHD Simulations

In this study, we compare the SDO/HMI line-of-sight observables (magnetic field, velocity, continuum intensity, and line depth) with the related physical properties for several dynamo simulation runs performed using the "StellarBox" 3D Radiative MHD code. The modeling of the Fe I 6173 A Stokes profiles is performed using the SPINOR radiative transfer code in the LTE approximation. The reproduced SDO/HMI line-of-sight pipeline is applied to the modeled spectra, and the observables are synthesized with high (numerical) and SDO/HMI (instrumental) resolutions. Correlations between the observables and the physical properties at various heights in the atmosphere are studied for a set of view angles (0, 30, 45, 60, 70, and 80 degrees away from the solar disk center). It is found that the SDO/HMI magnetic field and velocity measurements are unambiguously correlated with physical parameters at certain heights of the solar atmosphere. These heights increase from about 100 km above the photosphere for the disk center case to 300-600 km above the photosphere for the 80-degree case. The heights are found to be slightly lower in regions where stronger magnetic fields are found. The comparison of the photospheric magnetic flux and integrated continuum intensity derived from the SDO/HMI observables and high-resolution observations and spectra is discussed. The results of our study improve physics-based interpretations of the SDO/HMI observables and provide a better understanding of the physical properties of the solar atmosphere.

SMD↗

Active control of sound transmission/radiation from elastic plates by vibration inputs. II - Experiments

Actively controlled harmonic force inputs were applied experimentally to reduce the sound transmitted through an elastic circular plate. The control implementation used a time domain least mean square adaptive algorithm with two error sensors. The control forces were applied directly to the plate by point force vibration inputs, while the error information and performance were measured in the radiated acoustic field by microphones. Test cases were also performed in which the error sensors were accelerometers mounted on the plate. When accelerometers were used as error sensors, the controller performance was degraded; leading to the conclusion that minimizing plate motion does not necessarily lead to an associated decrease in radiated sound levels. In contrast, the results show excellent attenuation of the transmitted sound field when microphone error sensors were used. This result was consistent over a range of frequencies. In addition, the experimental results are compared to previously derived analytical results and the effect of using a point or global minimization scheme is discussed.

Metcalf, V. L.↗

Saturn Radiation Dose Environment Characterization

To understand the environment where a time-resolved hard x-ray spectrometer (AXIOM) might be fielded, experiments and simulations were performed to analyze the radiation dose environment underneath the Saturn vacuum dome. Knowledge of this environment is critical to the design and placement of the spectrometer. Experiments demonstrated that the machine performance, at least in terms of on-axis dose, has not significantly changed over the decades. Simulations of the off-axis dose were performed to identify possible spectrometer locations of interest. The effects from the source and dome hardware as well as source distributions and angles of incidence on the radiation environment were also investigated. Finally, a unified radiation transport model was developed for two widely used radiation transport codes to investigate the off-axis dose profiles and the time-dependent x-ray energy spectrum. The demonstrated equivalence of the unified radiation transport model between the radiation transport codes allows the team to tie future time-dependent x-ray environment calculations to previous integral simulations for the Saturn facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IR Camera Report for the 7 Day Production Test

The following report gives a summary of the IR camera performance results and data for the 7 day production run that occurred from 10 Sep 2015 thru 16 Sep 2015. During this production run our goal was to see how well the camera performed its task of monitoring the target window temperature with our improved alignment procedure and emissivity measurements. We also wanted to see if the increased shielding would be effective in protecting the camera from damage and failure.

43 PARTICLE ACCELERATORS↗

Objective characterization of GE Discovery CT750 HD scanner: Gemstone spectral imaging mode

Purpose: To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. Methods: A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol (preset 11) that is similar to the regular protocol and has a moderate dose level (CTDI{sub vol}=26.27 mGy) was compared to the baseline protocol. The resolving power of both protocols was characterized in terms of modulation transfer functions and high contrast resolution bar readings. Their noise characteristics were studied through noise power spectra, and their low contrast detectability was compared via contrast-to-noise ratio. Material decomposition capability of GSI was evaluated by scanning iodine solutions of 9-24 mg/ml iodine concentration in a Gammex CT phantom and by examining the estimated iodine concentration. In addition, a formula describing the dependency of HU in iodine enhanced area on GSI monochromatic energies and iodine concentrations was provided and the theoretical values were compared with the measured results. Results: The resolutions levels of 50%, 10%, and 5% MTF of GSI monochromatic images at 65 keV agree with those of the regular protocol within 0.1 lp/cm. GSI monochromatic images at 65 keV demonstrated the lowest noise level among GSI images of different monochromatic energies and showed very similar noise magnitude and noise power distribution as compared to the regular protocol images. The CNR of 60 and 65 keV GSI monoimages are approximately 100% of those of the regular protocol images. Estimated iodine concentration levels agreed with the actual values within 2% when the iodine solutions were placed at 3, 9, 12 o'clock positions of the phantom; when iodine solutions were placed at the phantom center and at 6 o'clock position, higher discrepancies of 2%-10% were observed. The observed dependency of HU on keV and iodine concentration levels agreed with the expectation from x-ray attenuations. Conclusions: Equivalent performances were observed in the comparison between GSI 65 keV monochromatic images and images from a regular abdomen scan protocol. This suggests the possibility of GSI to be employed in routine abdominal scans, which would potentially offer more information through its capabilities of material decomposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of aerosol vertical profiles on satellite-estimated surface particle sulfate concentrations

The aerosol vertical distribution is an important factor in determining the relationship between satellite retrieved aerosol optical depth (AOD) and ground-level fine particle pollution concentrations. We evaluate how aerosol profiles measured by ground-based lidar and simulated by models can help improve the association between AOD retrieved by the Multi-angle Imaging Spectroradiometer (MISR) and fine particle sulfate (SO4) concentrations using matched data at two lidar sites. At the Goddard Space Flight Center (GSFC) site, both lidar and model aerosol profiles marginally improve the association between SO4 concentrations and MISR fractional AODs, as the correlation coefficient between cross-validation (CV) and observed SO4 concentrations changes from 0.87 for the no-scaling model to 0.88 for models scaled with aerosol vertical profiles. At the GSFC site, a large amount of urban aerosols resides in the well-mixed boundary layer so the column fractional AODs are already excellent indicators of ground-level particle pollution. In contrast, at the Atmospheric Radiation Measurement Program (ARM) site with relatively low aerosol loadings, scaling substantially improves model performance. The correlation coefficient between CV and observed SO4 concentrations is increased from 0.58 for the no-scaling model to 0.76 in the GEOS-Chem scaling model, and the model bias is reduced from 17% to 9%. In summary, despite the inaccuracy due to the coarse horizontal resolution and the challenges of simulating turbulent mixing in the boundary layer, GEOS-Chem simulated aerosol profiles can still improve methods for estimating surface aerosol (SO4) mass from satellite-based AODs, particularly in rural areas where aerosols in the free troposphere and any long-range transport of aerosols can significantly contribute to the column AOD.

54 ENVIRONMENTAL SCIENCES↗

Effect of interfacial excess oxygen on positive-bias temperature stress instability of self-aligned coplanar InGaZnO thin-film transistors

We investigated the impact of excess oxygen on positive bias temperature stress (PBTS) instability of self-aligned coplanar amorphous InGaZnO thin-film transistors. We focus on the interface region which is compositionally differentiated from the bulk material on each side. The threshold voltage shift under PBTS is proportional to the extracted density of interface trap states that act as electron traps. The density of interface trap states is extracted from capacitance-voltage measurements with monochromatic light of varying wavelengths. We introduce a figure-of-merit that quantifies the amount of excess oxygen relative to the metal cation composition in the interface region. Minimization of interfacial excess oxygen from 112.4% to 101.2% reduces the density of interface trap states by a factor of 2.77, resulting in improvement of PBTS instability from a threshold voltage shift value of 4.42 V to 0.35 V.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence for the eta{sub b}(1S) Meson in Radiative UPSILON(2S) Decay

We have performed a search for the eta{sub b}(1S) meson in the radiative decay of the UPSILON(2S) resonance using a sample of 91.6x10{sup 6} UPSILON(2S) events recorded with the BABAR detector at the PEP-II B factory at the SLAC National Accelerator Laboratory. We observe a peak in the photon energy spectrum at E{sub {gamma}}=609.3{sub -4.5}{sup +4.6}(stat)+-1.9(syst) MeV, corresponding to an eta{sub b}(1S) mass of 9394.2{sub -4.9}{sup +4.8}(stat)+-2.0(syst) MeV/c{sup 2}. The branching fraction for the decay UPSILON(2S)->gammaeta{sub b}(1S) is determined to be [3.9+-1.1(stat){sub -0.9}{sup +1.1}(syst)]x10{sup -4}. We find the ratio of branching fractions B[UPSILON(2S)->gammaeta{sub b}(1S)]/B[UPSILON(3S)->gammaeta{sub b}(1S)]=0.82+-0.24(stat){sub -0.19}{sup +0.20}(syst).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-Level Radio Frequency System Development for the National Synchrotron Light Source II

The National Synchrotron Light Source-II (NSLS-II) is a new ultra-bright 3GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. The position and timing specifications of the ultra-bright photon beam imposes a set of stringent requirements on the performance of radio frequency (RF) control. In addition, commissioning and staged installation of damping wigglers and insertion devices requires the flexibility of handling varying beam conditions. To meet these requirements, a digital implementation of the LLRF is chosen, and digital serial links are planned for the system integration. The first prototype of the controller front-end hardware has been built, and is currently being tested.

43 PARTICLE ACCELERATORS↗

Preliminary Low Temperature Electron Irradiation of Triple Junction Solar Cells

For many years extending solar power missions far from the sun has been a challenge not only due to the rapid falloff in solar intensity (intensity varies as inverse square of solar distance) but also because some of the solar cells in an array may exhibit a LILT (low intensity low temperature) degradation that reduces array performance. Recent LILT tests performed on commercial triple junction solar cells have shown that high performance can be obtained at solar distances as great as approx. 5 AU1. As a result, their use for missions going far from the sun has become very attractive. One additional question that remains is whether the radiation damage experienced by solar cells under low temperature conditions will be more severe than when measured during room temperature radiation tests where thermal annealing may take place. This is especially pertinent to missions such as the New Frontiers mission Juno, which will experience cell irradiation from the trapped electron environment at Jupiter. Recent testing2 has shown that low temperature proton irradiation (10 MeV) produces cell degradation results similar to room temperature irradiations and that thermal annealing does not play a factor. Although it is suggestive to propose the same would be observed for low temperature electron irradiations, this has not been verified. JPL has routinely performed radiation testing on commercial solar cells and has also performed LILT testing to characterize cell performance under far sun operating conditions. This research activity was intended to combine the features of both capabilities to investigate the possibility of any room temperature annealing that might influence the measured radiation damage. Although it was not possible to maintain the test cells at a constant low temperature between irradiation and electrical measurements, it was possible to obtain measurements with the cell temperature kept well below room temperature. A fluence of 1E15 1MeV electrons was selected as representative of a moderately high dose that might be expected for a solar powered mission. Fluences much greater than this would require large increases in array area and mass, compromising the ability of PV to compete with non-solar alternatives.

Stella, Paul M.↗

TU-AB-202-06: Quantitative Evaluation of Deformable Image Registration in MRI-Guided Adaptive Radiation Therapy

Purpose: To assess the performance of the deformable image registration algorithm used for MRI-guided adaptive radiation therapy using image feature analysis. Methods: MR images were collected from five patients treated on the MRIdian (ViewRay, Inc., Oakwood Village, OH), a three head Cobalt-60 therapy machine with an 0.35 T MR system. The images were acquired immediately prior to treatment with a uniform 1.5 mm resolution. Treatment sites were as follows: head/neck, lung, breast, stomach, and bladder. Deformable image registration was performed using the ViewRay software between the first fraction MRI and the final fraction MRI, and the DICE similarity coefficient (DSC) for the skin contours was reported. The SIFT and Harris feature detection and matching algorithms identified point features in each image separately, then found matching features in the other image. The target registration error (TRE) was defined as the vector distance between matched features on the two image sets. Each deformation was evaluated based on comparison of average TRE and DSC. Results: Image feature analysis produced between 2000–9500 points for evaluation on the patient images. The average (± standard deviation) TRE for all patients was 3.3 mm (±3.1 mm), and the passing rate of TRE<3 mm was 60% on the images. The head/neck patient had the best average TRE (1.9 mm±2.3 mm) and the best passing rate (80%). The lung patient had the worst average TRE (4.8 mm±3.3 mm) and the worst passing rate (37.2%). DSC was not significantly correlated with either TRE (p=0.63) or passing rate (p=0.55). Conclusions: Feature matching provides a quantitative assessment of deformable image registration, with a large number of data points for analysis. The TRE of matched features can be used to evaluate the registration of many objects throughout the volume, whereas DSC mainly provides a measure of gross overlap. We have a research agreement with ViewRay Inc.

60 APPLIED LIFE SCIENCES↗

Integrated treatment of detector arrays for source tracking.

Illicit radioactive sources can potentially appear in a wide range of public venues. One element in a plan for managing such sources involves searching for them in venues at risk and tracking them in real time when they are detected. A treatment of source tracking using multiple directional detectors in a probabilistic framework is given. The performance of a prototype directional detector based on these methods was characterized in the laboratory. Instances where the performance of a directional detector is not immune to the effects of shielding are identified.

07 ISOTOPE AND RADIATION SOURCES↗