Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ranking methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Hygrothermal Simulations of Foundations: Part 1 - Soil Material Properties

Hygrothermal performance of soils coupled to buildings is a complicated process. The computational approach for heat transfer via the ground is well defined (EN-ISO-13370:, 2007) together with simplified methods (Staszczuk, Radon, & Holm). Though the soil moisture transfer is generally ignored, it is proven not negligible (Janssen, Carmeliet, & Hens, 2004). Even though reliable material properties of soils are required to perform realistic hygrothermal calculations of soils coupled to buildings, such material properties have not been well defined in hygrothermal calculations tools. Typical building constructions which are greatly influenced by soils are basements, crawl spaces and slab on grade and reliable hygrothermal performance of such construction are highly requested; as it is ranked within the top 10 Building America Enclosure Research Ideas according to Enclosures STC - Residential Energy Efficiency Stakeholder Meeting, February 29, 2012 Austin, TX. There exists an extensive amount of measurements on soil properties in Soil Science though this information must be gathered as well as adapted to be applicable in Building Science and for hygrothermal simulation purposes. Soil properties are important when analyzing and designing both new building constructions and retrofitting measures, where the outer boundary of the buildings enclosure consists of soil materials. Concerning basement energy retrofits, interior solutions of improving the energy demand has to cooperate with the existing soil properties and must therefore be designed thereafter. In concerns of exterior retrofits, the soil material can be replaced, if needed, with a more suitable filling material, though this approach applies only for basement walls. The soil material beneath the basement floor can naturally not be replaced hence the soil properties of this part of the buildings enclosure still must be taken into consideration. This study is divided into several parts. The intention of the first part is to gather, comprehend and adapt soil properties from soil science. The obtained information must be applicable for Building Science related tasks and validated in hygrothermal calculation tools hence the second part of this study will focus on validation of the implemented soil properties. Basic changes in the software code may be requested as well. Different basement constructions will be created with a hygrothermal calculation tool, WUFI, from which simulations will be compared with existing or on-going measurements. The final outcome of the study is to enable an evaluation of several soil types in several climate zones combined with a number of basement assemblies. The study will define which type of soil together with a certain building construction which is considered most and least reliable in concerns of energy consumption and moisture safety. Further, what influences different soils will have on the total energy loss via the ground and if the performance of a different soils can be measured by a comparison of soil properties solely.

Pallin, Simon B↗

Anomaly Detection in Connected and Autonomous Vehicle Trajectories Using LSTM Autoencoder and Gaussian Mixture Model

Connected and Autonomous Vehicles (CAVs) technology has the potential to transform the transportation system. Although these new technologies have many advantages, the implementation raises significant concerns regarding safety, security, and privacy. Anomalies in sensor data caused by errors or cyberattacks can cause severe accidents. To address the issue, this study proposed an innovative anomaly detection algorithm, namely the LSTM Autoencoder with Gaussian Mixture Model (LAGMM). This model supports anomalous CAV trajectory detection in the real-time leveraging communication capabilities of CAV sensors. The LSTM Autoencoder is applied to generate low-rank representations and reconstruct errors for each input data point, while the Gaussian Mixture Model (GMM) is employed for its strength in density estimation. The proposed model was jointly optimized for the LSTM Autoencoder and GMM simultaneously. The study utilizes realistic CAV data from a platooning experiment conducted for Cooperative Automated Research Mobility Applications (CARMAs). The experiment findings indicate that the proposed LAGMM approach enhances detection accuracy by 3% and precision by 6.4% compared to the existing state-of-the-art methods, suggesting a significant improvement in the field.

33 ADVANCED PROPULSION SYSTEMS↗

MIL-C-38999 electrical connector applicability tests for on-orbit EVA satellite servicing

MIL-C-38999 electrical connectors were tested for their applicability to the on-orbit EVA satellite servicing environment. The investigation provided a methodical approach to the evaluation of the human-machine interface of these connectors. The physical characteristics of thirty-five MIL-C-38999 connectors were tested in two simulated space environments, the NASA Johnson Space Center Weightless Environment Training Facility and an evacuated glovebox which incorporated the Extravehicular Maneuvering Unit series 3000 gloves. Physical characteristics of the connectors were documented, including operating torque and work profiles. STS crewmembers tested a select group of connectors in two WETF test and subjectively ranked the G&H PMM Wing-Tab connectors as most applicable to the on-orbit servicing environment. WETF performance times indicated that the G&H PMM Wing-Tab connector had the fastest operating time. The evacuated glovebox participants ranked the G&H 64600 Wing-Tab and the G&H PMM Wing-Tab connectors as those most applicable to the on-orbit servicing environment. During the evacuated glovebox tests, the G&H 64600 Wing-Tab connector had the fastest operating time.

Griffin, Thomas J.↗

A Flexible Power Method for Solving Infinite Dimensional Tensor Eigenvalue Problems

We propose a flexible power method for computing the leftmost, i.e., algebraically smallest, eigenvalue of an infinite dimensional tensor eigenvalue problem, $H x = \lambda x$, where the infinite dimensional symmetric matrix $H$ exhibits a translational invariant structure. We assume the smallest eigenvalue of $H$ is simple and apply a power iteration of $e^{-H}$ with the eigenvector represented in a compact way as a translational invariant infinite Tensor Ring (iTR). Hence, the infinite dimensional eigenvector can be represented by a finite number of iTR cores of finite rank. In order to implement this power iteration, we use a small parameter $t$ so that the infinite matrix-vector operation $e^{-Ht}x$ can efficiently be approximated by the Lie product formula, also known as Suzuki--Trotter splitting, and we employ a low rank approximation through a truncated singular value decomposition on the iTR cores in order to keep the cost of subsequent power iterations bounded. We also use an efficient way for computing the iTR Rayleigh quotient and introduce a finite size iTR residual which is used to monitor the convergence of the Rayleigh quotient and to modify the timestep $t$. In this paper, we discuss 2 different implementations of the flexible power algorithm and illustrate the automatic timestep adaption approach for several numerical examples.

Beeumen, Roel Van↗

SU-F-BRD-06: Robust Dose Calculation in Intensity Modulated Proton Therapy

Purpose: Commissioning data for intensity modulated proton therapy (IMPT) must be post-processed by fits to ad-hoc functions to derive the dose calculation kernel parameters in a treatment planning system (TPS). Whether from experimental measurement or Monte Carlo simulation, the limited and noisy nature of such data makes this task very challenging. We present a method to improve the modeling of the lateral dose distribution of clinical energy proton beams in water to commission an in-house IMPT dose calculation engine. Methods: A linear sum of three Gaussian distribution functions was fitted to the lateral dose data in logarithmic scale. Starting values of fitting solutions were determined from the Generalized Highland Approximation. We exhaustively optimized the combinations of data weights with upper bounds of the fitting solutions to minimize confidence intervals of the fitting solutions while maintaining the coefficient of determination (R{sup 2}). Results: Across all energies, average confidence bounds improved 72.88% [Max: 88.28%, Min: 55.05%] for small angle coulomb scattering, 114.25% [409.13%, 66.72%,] for nuclear scattering, and 68.66% [141.09%, 33.27%] for large angle coulomb scattering, while the coefficients of determination of the fits (R{sup 2}) remained comparable. On average R {sup 2} only changed 0.18% and were very close to 1 (approx. 0.999). Wilcoxon signed rank tests comparing unweighted/unbounded fits with weighted/bounded fits averaged 0.0146 (Max: 0.177, Min: 7.05×10−{sup 7}) for small angle Coulomb, 0.0903 (0.945, 7.05×10−{sup 7}) for nuclear, and 0.254 (0.871, 1.86×10−{sup 6}) for large angle Coulomb scattering. This allows rejection of the null hypothesis for small angle Coulomb scattering at the 0.015 level and nuclear interaction at the 0.1 level. Conclusion: Optimal weights assigned to IMPT lateral dose data minimized fitting to stochastic noise in the tail region. Optimizing the upper bounds of fitting parameters improved the robustness of fitting solutions. Both led to a more physically meaningful dose calculation kernel for the TPS. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.

60 APPLIED LIFE SCIENCES↗

Latent map Gaussian processes for mixed variable metamodeling

Gaussian processes (GPs) are ubiquitously used in sciences and engineering as metamodels. Standard GPs, however, can only handle numerical or quantitative variables. Here we introduce latent map Gaussian processes (LMGPs) that inherit the attractive properties of GPs and are also applicable to mixed data which have both quantitative and qualitative inputs. The core idea behind LMGPs is to learn a continuous, low-dimensional latent space or manifold which encodes all qualitative inputs. To learn this manifold, we first assign a unique prior vector representation to each combination of qualitative inputs. We then use a low-rank linear map to project these priors on a manifold that characterizes the posterior representations. As the posteriors are quantitative, they can be directly used in any standard correlation function such as the Gaussian or Matern. Hence, the optimal map and the corresponding manifold, along with other hyperparameters of the correlation function, can be systematically learned via maximum likelihood estimation. Through a wide range of analytic and real-world examples, we demonstrate the advantages of LMGPs over state-of-the-art methods in terms of accuracy and versatility. In particular, we show that LMGPs can handle variable-length inputs, have an explainable neural network interpretation, and provide insights into how qualitative inputs affect the response or interact with each other. We also employ LMGPs in Bayesian optimization and illustrate that they can discover optimal compound compositions more efficiently than conventional methods that convert compositions to qualitative variables via manual featurization.

42 ENGINEERING↗

Favorable Prognosis in Patients With High-Grade Glioma With Radiation Necrosis: The University of Colorado Reoperation Series

Purpose: To analyze the pathology, outcomes, and prognostic factors in patients with high-grade glioma undergoing reoperation after radiotherapy (RT). Methods and Materials: Fifty-one patients with World Health Organization Grade 3-4 glioma underwent reoperation after prior RT. The median dose of prior RT was 60 Gy, and 84% received chemotherapy as part of their initial treatment. Estimation of the percentage of necrosis and recurrent tumor in each reoperation specimen was performed. Pathology was classified as RT necrosis if {>=}80% of the specimen was necrotic and as tumor recurrence if {>=}20% was tumor. Predictors of survival were analyzed using log-rank comparisons and Cox proportional hazards regression. Results: The median interval between the completion of RT and reoperation was 6.7 months (range, 1-59 months). Pathologic analysis showed RT necrosis in 27% and recurrence in 73% of cases. Thirteen patients required a reoperation for uncontrolled symptoms. Among them, 1 patient (8%) had pathology showing RT necrosis, and 12 (92%) had tumor recurrence. Median survival after reoperation was longer for patients with RT necrosis (21.8 months vs. 7.0 months, p = 0.047). In 7 patients with Grade 4 tumors treated with temozolomide-based chemoradiation with RT necrosis, median survival from diagnosis and reoperation were 30.2 months and 21.8 months, respectively. Conclusions: Patients with RT necrosis at reoperation have improved survival compared with patients with tumor recurrence. Future efforts to intensify local therapy and increase local tumor control in patients with high-grade glioma seem warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation-Aided Robust Decentralized Dynamic State Estimation of Power Systems with Unknown Control Inputs

This paper proposes a correlation-aided robust adaptive unscented Kalman filter for power system decentralized dynamic state estimation with unknown inputs, termed as robust AUKF-UI. The temporal and spatial correlations among the unknown inputs are used to derive a vector auto-regressive (VAR) model in an adaptive manner. This VAR model is further integrated together with state transition and measurement models for joint state and unknown inputs estimation. This allows taking into account the implicit cross-correlations between the states and the unknown inputs. As a result, the rank requirement for unknown input vector estimation is relaxed and the local generator frequency measurement is not required. The temporal correlations of time series innovation vectors, predicted state and input vectors are also leveraged by the robust AUKFUI to detect, identify and process bad data. Without these correlations, it is very challenging to address bad data with unknown inputs. Simulation results carried out on the IEEE 39-bus system demonstrate that the proposed robust AUKF-UI achieves much better results than other methods in the presence of low measurement redundancy, strong nonlinearity, and bad data.

Zhao, Junbo↗

Flexible radioluminescence imaging for FDG-guided surgery

Purpose: Flexible radioluminescence imaging (Flex-RLI) is an optical method for imaging {sup 18}F-fluorodeoxyglucose (FDG)-avid tumors. The authors hypothesize that a gadolinium oxysulfide: terbium (GOS:Tb) flexible scintillator, which loosely conforms to the body contour, can enhance tumor signal-to-background ratio (SBR) compared with RLI, which utilizes a flat scintillator. The purpose of this paper is to characterize flex-RLI with respect to alternative modalities including RLI, beta-RLI (RLI with gamma rejection), and Cerenkov luminescence imaging (CLI). Methods: The photon sensitivity, spatial resolution, and signal linearity of flex-RLI were characterized with in vitro phantoms. In vivo experiments utilizing 13 nude mice inoculated with the head and neck (UMSCC1-Luc) cell line were then conducted in accordance with the institutional Administrative Panel on Laboratory Animal Care. After intravenous injection of {sup 18}F-FDG, the tumor SBR values for flex-RLI were compared to those for RLI, beta-RLI, and CLI using the Wilcoxon signed rank test. Results: With respect to photon sensitivity, RLI, beta-RLI, and flex-RLI produced 1216.2, 407.0, and 98.6 times more radiance per second than CLI. Respective full-width half maximum values across a 0.5 mm capillary tube were 6.9, 6.4, 2.2, and 1.5 mm, respectively. Flex-RLI demonstrated a near perfect correlation with {sup 18}F activity (r = 0.99). Signal uniformity for flex-RLI improved after more aggressive homogenization of the GOS powder with the silicone elastomer during formulation. In vivo, the SBR value for flex-RLI (median 1.29; interquartile range 1.18–1.36) was statistically greater than that for RLI (1.08; 1.02–1.14; p < 0.01) by 26%. However, there was no statistically significant difference in SBR values between flex-RLI and beta-RLI (p = 0.92). Furthermore, there was no statistically significant difference in SBR values between flex-RLI and CLI (p = 0.11) in a more limited dataset. Conclusions: Flex-RLI provides high quality images with SBRs comparable to those from CLI and beta-RLI in a single 10 s acquisition.

60 APPLIED LIFE SCIENCES↗

Low energy isomers of (H{sub 2}O){sub 25} from a hierarchical method based on Monte Carlo temperature basin paving and molecular tailoring approaches benchmarked by MP2 calculations

We report new global minimum candidate structures for the (H{sub 2}O){sub 25} cluster that are lower in energy than the ones reported previously and correspond to hydrogen bonded networks with 42 hydrogen bonds and an interior, fully coordinated water molecule. These were obtained as a result of a hierarchical approach based on initial Monte Carlo Temperature Basin Paving sampling of the cluster's Potential Energy Surface with the Effective Fragment Potential, subsequent geometry optimization using the Molecular Tailoring Approach with the fragments treated at the second order Møller-Plesset (MP2) perturbation (MTA-MP2) and final refinement of the entire cluster at the MP2 level of theory. The MTA-MP2 optimized cluster geometries, constructed from the fragments, were found to be within <0.5 kcal/mol from the minimum geometries obtained from the MP2 optimization of the entire (H{sub 2}O){sub 25} cluster. In addition, the grafting of the MTA-MP2 energies yields electronic energies that are within <0.3 kcal/mol from the MP2 energies of the entire cluster while preserving their energy rank order. Finally, the MTA-MP2 approach was found to reproduce the MP2 harmonic vibrational frequencies, constructed from the fragments, quite accurately when compared to the MP2 ones of the entire cluster in both the HOH bending and the OH stretching regions of the spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Giant Wilson loops and AdS 2 /dCFT 1

The 1/2-BPS Wilson loop in N = 4 supersymmetric Yang-Mills theory is an important and well-studied example of conformal defect. In particular, much work has been done for the correlation functions of operator insertions on the Wilson loop in the fundamental representation. In this paper, we extend such analyses to Wilson loops in the large-rank symmetric and antisymmetric representations, which correspond to probe D3 and D5 branes with AdS 2 × S 2 and AdS 2 × S 4 worldvolume geometries, ending at the AdS 5 boundary along a one-dimensional contour. We first compute the correlation functions of protected scalar insertions from supersymmetric localization, and obtain a representation in terms of multiple integrals that are similar to the eigenvalue integrals of the random matrix, but with important differences. Using ideas from the Fermi Gas formalism and the Clustering method, we evaluate their large N limit exactly as a function of the ’t Hooft coupling. The results are given by simple integrals of polynomials that resemble the Q-functions of the Quantum Spectral Curve, with integration measures depending on the number of insertions. Next, we study the correlation functions of fluctuations on the probe D3 and D5 branes in AdS. We compute a selection of three- and four-point functions from perturbation theory on the D-branes, and show that they agree with the results of localization when restricted to supersymmetric kinematics. We also explain how the difference of the internal geometries of the D3 and D5 branes manifests itself in the localization computation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Basic Fibroblast Growth Factor-2/beta3 Integrin Expression Profile: Signature of Local Progression After Chemoradiotherapy for Patients With Locally Advanced Non-Small-Cell Lung Cancer

Purpose: No biologic signature of chemoradiotherapy sensitivity has been reported for patients with locally advanced non-small-cell lung cancer (NSCLC). We have previously demonstrated that basic fibroblast growth factor (FGF-2) and alphavbeta3 integrin pathways control tumor radioresistance. We investigated whether the expression of the proteins involved in these pathways might be associated with the response to treatment and, therefore, the clinical outcome. Methods and Materials: FGF-2, beta3 integrin, angiopoietin-2, and syndecan-1 expression was studied using immunohistochemistry performed on biopsies obtained, before any treatment, from 65 patients exclusively treated with chemoradiotherapy for locally advanced NSCLC. The response to treatment was evaluated according to the Response Evaluation Criteria in Solid Tumors criteria using computed tomography at least 6 weeks after the end of the chemoradiotherapy. Local progression-free survival, metastasis-free survival, and disease-free survival were studied using the log-rank test and Cox proportional hazard analysis. Results: Among this NSCLC biopsy population, 43.7% overexpressed beta3 integrin (beta3{sup +}), 43% FGF-2 (FGF-2{sup +}), 41.5% syndecan-1, and 59.4% angiopoietin-2. Our results showed a strong association between FGF-2 and beta3 integrin expression (p = .001). The adjusted hazard ratio of local recurrence for FGF-2{sup +}/beta3{sup +} tumors compared with FGF-2{sup -}/beta3{sup -} tumors was 6.1 (95% confidence interval, 2.6-14.6, p = .005). However, the risk of local recurrence was not increased when tumors overexpressed beta3 integrin or FGF-2 alone. Moreover, the co-expression of these two proteins was marginally associated with the response to chemoradiotherapy and metastasis-free survival. Conclusion: The results of this study have identified the combined profile FGF-2/beta3 integrin expression as a signature of local control in patients treated with chemoradiotherapy for locally advanced NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure to Adhere to Protocol Specified Radiation Therapy Guidelines Was Associated With Decreased Survival in RTOG 9704-A Phase III Trial of Adjuvant Chemotherapy and Chemoradiotherapy for Patients With Resected Adenocarcinoma of the Pancreas

Purpose: In Radiation Therapy Oncology Group 9704, as previously published, patients with resected pancreatic adenocarcinoma received continuous infusion 5-FU and concurrent radiotherapy (5FU-RT). 5FU-RT treatment was preceded and followed by randomly assigned chemotherapy, either 5-FU or gemcitabine. This analysis explored whether failure to adhere to specified RT guidelines influenced survival and/or toxicity. Methods and Materials: RT requirements were protocol specified. Adherence was scored as per protocol (PP) or less than per protocol (<PP). Scoring occurred after therapy but before trial analysis and without knowledge of individual patient treatment outcomes. Scoring was done for all tumor locations and for the subset of pancreatic head location. Results: RT was scored for 416 patients: 216 PP and 200 <PP. For all pancreatic sites (head, body/tail) median survival (MS) for PP vs. <PP was 1.74 vs. 1.46 years (log-rank p = 0.0077). In multivariate analysis, PP vs. <PP score correlated more strongly with MS than assigned treatment arm (p = 0.014, p = NS, respectively); for patients with pancreatic head tumors, both PP score and gemcitabine treatment correlated with improved MS (p = 0.016, p = 0.043, respectively). For all tumor locations, PP score was associated with decreased risk of failure (p = 0.016) and, for gemcitabine patients, a trend toward reduced Grade 4/5 nonhematologic toxicity (p = 0.065). Conclusions: This is the first Phase III, multicenter, adjuvant protocol for pancreatic adenocarcinoma to evaluate the impact of adherence to specified RT protocol guidelines on protocol outcomes. Failure to adhere to specified RT guidelines was associated with reduced survival and, for patients receiving gemcitabine, trend toward increased nonhematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Report of a Prospective Dosimetric and Clinical Feasibility Trial Demonstrates the Potential of Protons to Increase the Therapeutic Ratio in Breast Cancer Compared With Photons

Purpose: To compare dosimetric endpoints between proton therapy (PT) and conventional radiation and determine the feasibility of PT for regional nodal irradiation (RNI) in women with breast cancer. Methods and Materials: From 2012 to 2014, 18 women (stage IIA-IIIB) requiring RNI prospectively enrolled on a pilot study. Median age was 51.8 years (range, 42-73 years). The cohort included breast-conserving therapy (BCT) and mastectomy patients and right- and left-sided cancers. Treatment targets and organs at risk were delineated on computed tomography scans, and PT and conventional plans were developed. Toxicity was prospectively recorded using Common Terminology Criteria for Adverse Events version 4.0. A Wilcoxon signed-rank sum test compared the dose-volume parameters. The primary endpoint was a reduction in cardiac V5. Results: Median follow-up was 20 months (range, 2-31 months). For all patients, the PT plan better met the dosimetric goals and was used for treatment. Proton therapy alone was used for 10 patients (9 postmastectomy, 1 after BCT) and combined proton–photon in 8 (6 BCT, 2 postmastectomy with immediate expander reconstruction). Proton therapy improved coverage of level 2 axilla (P=.0005). Adequate coverage of internal mammary nodes was consistently achieved with PT (median D95, 50.3 Gy; range, 46.6-52.1 Gy) but not with conventional radiation therapy (median D95, 48.2 Gy; range, 40.8-55 Gy; P=.0005). Median cardiac V5 was 0.6% with PT and 16.3% with conventional radiation (P<.0001). Median ipsilateral lung V5 and V20 were improved with PT (median V5 35.3% vs 60.5% [P<.0001]; and median V20, 21.6% vs 35.5% [P<.0001]). Grade 3 dermatitis developed in 4 patients (22%), which was the only grade 3 toxicity. No grade 4+ toxicities developed. Conclusion: Proton therapy for RNI after mastectomy or BCT significantly improves cardiac dose, especially for left-sided patients, and lung V5 and V20 in all patients without excessive acute toxicity. Proton therapy simultaneously improves target coverage for the internal mammary nodes and level 2 axilla, which may positively impact long-term survival in breast cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Morphometric Comparison of Clavicle Outlines from 3D Bone Scans and 2D Chest Radiographs: A Short-listing Tool to Assist Radiographic Identification of Human Skeletons

This paper describes a computerized clavicle identification system, primarily designed to resolve the identities of unaccounted for US soldiers who fought in the Korean War. Elliptical Fourier analysis is used to quantify the clavicle outline shape from skeletons and postero-anterior antemortem chest radiographs to rank individuals in terms of metric distance. Similar to leading fingerprint identification systems, shortlists of the top matching candidates are extracted for subsequent human visual assessment. Two independent tests of the computerized system using 17 field-recovered skeletons and 409 chest radiographs demonstrate that true positive matches are captured within the top 5% of the sample 75% of the time. These results are outstanding given the eroded state of some field-recovered skeletons and the faintness of the 1950’s photoflurographs. These methods enhance the capability to resolve several hundred cold cases for which little circumstantial information exists and current DNA and dental record technologies cannot be applied.

computer assisted↗

Quality-of-Life Assessment After Palliative Interventions to Manage Malignant Ureteral Obstruction

Purpose:: Malignancies may cause urinary tract obstruction, which is often relieved with placement of a percutaneous nephrostomy tube, an internal double J nephro-ureteric stent (double J), or an internal external nephroureteral stent (NUS). We evaluated the affect of these palliative interventions on quality of life (QoL) using previously validated surveys. Methods:: Forty-six patients with malignancy related ureteral obstruction received nephrostomy tubes (n = 16), double J stents (n = 15), or NUS (n = 15) as determined by a multidisciplinary team. QoL surveys were administered at 7, 30, and 90 days after the palliative procedure to evaluate symptoms and physical, social, functional, and emotional well-being. Number of related procedures, fluoroscopy time, and complications were documented. Kruskal–Wallis and Friedman’s test were used to compare patients at 7, 30, and 90 days. Spearman’s rank correlation coefficient was used to assess correlations between clinical outcomes/symptoms and QoL. Results:: Responses to QoL surveys were not significantly different for patients receiving nephrostomies, double J stents, or NUS at 7, 30, or 90 days. At 30 and 90 days there were significantly higher reported urinary symptoms and pain in those receiving double J stents compared with nephrostomies (P = 0.0035 and P = 0.0189, respectively). Significantly greater fluoroscopy time was needed for double J stent–related procedures (P = 0.0054). Nephrostomy tubes were associated with more frequent minor complications requiring additional changes. Conclusion:: QoL was not significantly different. However, a greater incidence of pain in those receiving double J stents and more frequent tube changes in those with nephrostomy tubes should be considered when choosing palliative approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison Between Low-Dose-Rate Brachytherapy With or Without Androgen Deprivation, External Beam Radiation Therapy With or Without Androgen Deprivation, and Radical Prostatectomy With or Without Adjuvant or Salvage Radiation Therapy for High-Risk Prostate Cancer

Purpose: We compare the efficacy and toxicity among the 3 major modalities available used to treat high-risk prostate cancer (HRCaP). Methods and Materials: From 1996 to 2012, 2557 HRCaP patients were treated: 734 received external beam radiation therapy (EBRT) with or without androgen deprivation therapy (ADT), 515 received low-dose-rate prostate brachytherapy (LDR) with or without ADT, and 1308 received radical prostatectomy (RP) with or without EBRT. Biochemical relapse-free survival (bRFS), clinical relapse-free survival (cRFS), and prostate cancer–specific mortality (PCSM) were assessed. Toxicity was assessed using the Common Terminology Criteria for Adverse Events, version 4.03. The log-rank test compared bRFS and cRFS among the modalities, and Cox regression identified factors associated with bRFS and cRFS. Gray's test compared differences in late toxicity and PSCM among the modalities. Competing risk regression identified factors associated with PCSM. Results: The median follow-up time and age were 63.5 months and 65 years, respectively. The bRFS at 5 and 10 years, respectively, was 74% and 53% for EBRT, 74% and 52% for LDR, and 65% and 47% for RP (P=.0001). The cRFS at 5 and 10 years, respectively, was 85% and 73% for EBRT, 90% and 76% for LDR, and 89% and 75% for RP (P=.121). The PCSM at 5 and 10 years, respectively, was 5.3% and 11.2% for EBRT, 3.2% and 3.6% for LDR, and 2.8% and 6.8% for RP (P=.0004). The 10-year cumulative incidence of ≥grade 3 genitourinary toxicity was 8.1% for EBRT, 7.2% for LDR, and 16.4% for RP (P<.0001). The 10-year cumulative incidence of ≥grade 3 gastrointestinal toxicity was 4.6% for EBRT, 1.1% for LDR, and 1.0% for RP (P<.0001). Conclusion: HRCaP treated with EBRT, LDR, or RP yields efficacy showing better bRFS for LDR and EBRT relative to RP, equivalence for cRFS, and a PCSM advantage of LDR and RP over EBRT. The toxicity is lowest for LDR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient Measurement-Driven Eigenenergy Estimation with Classical Shadows

Quantum algorithms exploiting real-time evolution under a target Hamiltonian have demonstrated remarkable efficiency in extracting key spectral information. However, the broader potential of these methods, particularly beyond ground-state calculations, is underexplored. In this work, we introduce the framework of multiobservable dynamic mode decomposition (MODMD), which combines the observable dynamic mode decomposition (DMD), a measurement-driven eigensolver tailored for near-term implementation, with classical shadow tomography. MODMD leverages random scrambling in the classical shadow technique to construct, with exponentially reduced resource requirements, a signal subspace that encodes rich spectral information. Notably, we replace typical Hadamard-test circuits with a protocol designed to predict low-rank observables, thereby broadening the use of classical shadow tomography for predicting many low-rank observables. We establish theoretical guarantees on the spectral approximation from MODMD, taking into account distinct sources of error. In the ideal case, we prove that the spectral error scales as exp (−Δ⁢𝐸⁢𝑡 max ), where Δ⁢𝐸 is the Hamiltonian spectral gap and 𝑡 max is the maximal simulation time. This analysis provides a rigorous justification of the rapid convergence observed across simulations. To demonstrate the utility of our framework, we consider its application to fundamental tasks, such as determining the low-lying, i.e., ground or excited, energies of representative many-body systems. Our work paves the path for efficient designs of measurement-driven algorithms on near-term and early fault-tolerant quantum devices.

quantum algorithms & computation↗