Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rate capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Delta: Data Reduction for Integrated Application Workflows

Integrated Application Workflows (IAWs) run multiple simulation workflow components concurrently on an HPC resource connecting these components using compute area resources and compensating for any performance or data processing rate mismatches. These IAWs require high frequency and high volume data transfers between compute nodes and staging area nodes during the lifetime of a large parallel computation. The available network band-width between the two areas may not be enough to efficiently support the data movement. As the processing power available to compute resources increases, the requirements for this data transfer will become more difficult to satisfy and perhaps will not be satisfiable at all since network capabilities are not expanding at a comparable rate. Furthermore, energy consumption in HPC environments is expected to grow by an order of magnitude as exascale systems become a reality. The energy cost of moving large amounts of data frequently will contribute to this issue. It is necessary to reduce the volume of data without reducing the quality of data when it is being processed and analyzed. Delta resolves the issue by addressing the lifetime data transfer operations. Delta removes subsequent identical copies of already transmitted data during transfers and restores those copies once the data has reached the destination. Delta is able to identify duplicated information and determine the most space efficient way to represent it. Initial tests show about 50% reduction in data movement while maintaining the same data quality and transmission frequency.

97 MATHEMATICS AND COMPUTING↗

TH-EF-BRB-07: Novel Hardware and Software Platform for Intermediate Energy 4π Radiotherapy

Purpose: To develop a robust and efficient platform for the optimization and robotic delivery of highly noncoplanar intensity modulated radiotherapy, which enables significant reduction of normal tissue toxicity and escalation of tumor dose. Methods: An innovative high-output compact 3 MV linac was designed for mounting onto a commercial robotic system in order to access the entire 4π beam solution space without moving the patient couch. The use of intermediate energy X-rays for radiotherapy was evaluated in comparison to clinical plans delivered using 6 MV X-rays and a state-of-the-art delivery system. Monte Carlo simulations of a 3 MV percent depth dose curve were performed for intermediate energy dose calculation. The beam model was used to create a convolution/superposition-based dose calculation engine for 3MV X-rays. The 4π greedy column generation algorithm was used for optimized beam selection and fluence map optimization. Results: A detailed design of the first 3 MV linac capable of producing a competitively high dose rate of >800 cGy/min at 100 cm was completed and verified through extensive simulation. The complete linac head including a multileaf collimator can access most of the 4π solution space including the posterior orientations without changing the couch height. When compared to 6 MV clinical plans, the proposed 3 MV 4π plans demonstrated significantly better dose compactness and normal tissue sparing in brain, prostate, and partial breast treatment plans. Conclusion: We demonstrate the design of a highly versatile radiotherapy machine to natively deliver non-coplanar 4π radiotherapy without the need to move the patient during treatment. This novel platform is efficient and capable of providing dosimetry that is 30–50% more compact than existing therapy platforms. The new system is projected to be cost effective due to improved treatment time and automation. NIH R43CA183390, NIH R01CA188300.

60 APPLIED LIFE SCIENCES↗

Ultra-scale vehicle tracking in low spatial-resolution and low frame-rate overhead video

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery either in real-time or quickly on-demand is very desirable. With this ability we can begin to answer a number of interesting questions such as, what are normal traffic patterns in a particular region or where did that truck come from? There are many challenges associated with processing this type of data, some of which we will address in the paper. Wide-field image sequences are very large with many thousands of pixels on a side and are characterized by lower resolutions (e.g. worse than 0.5 meters/pixel) and lower frame rates (e.g. a few Hz or less). The objects in the scenery can vary in size, density, and contrast with respect to the background. At the same time the background scenery provides a number of clutter sources both man-made and natural. We describe our current implementation of an ultrascale capable multiple-vehicle tracking algorithm for overhead persistent surveillance imagery as well as discuss the tracking and timing performance of the currently implemented algorithm which is aimed at utilizing grayscale electrooptical image sequences alone for the track segment generation.

42 ENGINEERING↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

Designing Electrolytes With Controlled Solvation Structure for Fast‐Charging Lithium‐Ion Batteries

Recharging battery-powered electric vehicles (EVs) in a similar timeframe as those used for refueling gas-powered internal combustion vehicles is highly desirable for rapid penetration of the EV market. It is well known that the electrolyte in a battery plays a critical role in fast-charging capability of the battery because it determines the rate of ion transport together with its derived electrode/electrolyte interphases on both cathode and anode of the battery. In this study, the effects of contents of salt, coordinating solvent, and noncoordinating diluent on salt dissociation degree and electrolyte ionic conductivity are investigated, and a controlled solvation structure electrolyte is developed to improve the lithium ion mobility and conductivity in the electrolyte and to enhance the kinetics and stability of the electrode/electrolyte interphases in the battery. This electrolyte enables fast-charging capability of high energy density lithium-ion batteries (LIBs) at up to 5 C rate (12-min charging), which significantly outperforms the state-of-the-art electrolyte. The controlled solvation structure sheds light on the future electrolyte design for fast-charging LIBs.

25 ENERGY STORAGE↗

Record High Ramping Rates in HTS Based Superconducting Accelerator Magnet

Here we report results of experimental test of the High Temperature Superconductor (HTS) based fast-cycling prototype accelerator magnet capable to operate up to about 300 T/s field ramping rate with some 0.5 T B-field in the magnet gap. The measured upper limit for the cryogenic cooling power required to support magnet conductor operation at high ramping rates indicates great potential for such type of magnets in rapid cycling synchrotrons for neutrino research or acceleration of very short-lived muons. The test magnet design, construction and supporting cryogenic and power systems are briefly described. The magnet's power test results are discussed in terms of a possible upgrade of this magnet design to 2 T B-field, a maximum feasible with super-ferric magnet.

43 PARTICLE ACCELERATORS↗

7 Innovations in high-rate composite manufacturing: integrating additive manufacturing with compression molding process

Advanced composites play a pivotal role in modern engineering, offering exceptional strength-to-weight ratios and tailored properties, essential for various industries. High-rate composite manufacturing techniques have rapid production capabilities, which are essential for meeting the demands of industries requiring cost-saving, efficiency, and quick turnaround times. This chapter explores the Additive Manufacturing- Compression Molding (AM-CM) system developed by Oak Ridge National Laboratory (ORNL) for advanced composites manufacturing. The AM-CM system integrates additive manufacturing with compression molding, facilitating the production of polymer composite parts with superior mechanical properties and meticulously controlled microstructures. This innovative system not only ensures precise material deposition but also operates as a fast composite manufacturing process, enhancing productivity and performance, which are needed attributes across industrial applications. Through comprehensive mechanical testing and microstructural analysis, AM-CM promotes remarkable fiber alignment and reduced porosity in composite parts compared to alternative thermoplastic high-rate composite manufacturing methods. Furthermore, AM-CM enables overmolding reinforcement using continuous carbon fiber and supports selective reinforcement through customizable toolpaths. It also facilitates the production of hybrid materials to achieve tailored mechanical properties. Future advancements in AM-CM technology aim to enhance process efficiency, broaden material versatility, and improve part performance. This involves exploring novel materials, advancing process monitoring, implementing automation technologies, and integrating artificial intelligence (AI) and machine learning (ML) for predictive modeling and real-time optimization in composite manufacturing. These developments will establish the AM-CM system as a transformative technology in composite manufacturing, driving innovation across industries.

Hassen, Ahmed [ORNL] (ORCID:0000000328521222)↗

Insights into Constraining Rate Coefficients in Fuel Oxidation Mechanisms Using Genetic Algorithm Optimization

Accurate fuel oxidation mechanisms can enable predictive capabilities that aid in advancing combustion technologies. High-level computational kinetics can yield reasonable rate coefficients with uncertainties, in some cases, below a factor of 2. Computed rate coefficients can be constrained further by optimizing against experimental data. Here, we explore the application of genetic algorithm (GA) optimization to constrain computed rate coefficients in complex fuel oxidation mechanisms in conjunction with temperature-dependent species mole fractions from jet-stirred reactor (JSR) measurements. Cyclohexane is a model candidate for understanding the reactivity of cyclic fuels. In this work, we optimize the rate coefficients of the most recent literature cyclohexane mechanism, which incorporates theoretically computed rate coefficients for the reaction networks stemming from the first and second O 2 addition pathways, against the experimental results of two separate literature JSR studies. Optimization consistency is evaluated by carrying out three GA optimizations: fitting to the temperature-dependent species mole fractions in each JSR experiment separately and simultaneously fitting the species mole fractions in both experiments. Local sensitivity analyses are used to identify five influential low-temperature oxidation reactions for optimization. Although the three optimizations do not yield identical rate coefficients, the direction of change in all five rate coefficients is consistent among the three optimizations. Performance of the models from the three optimizations is assessed against literature ignition delay times with differences in the level of agreement observed among the different optimizations. In conclusion, comparisons are made with our recent optimization work of a cyclopentane oxidation master-equation model against time-resolved species concentrations, and insights and improvements of the strategy for constraining rate coefficients using GA optimization are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Design, Implementation, and Evaluation of a Hybrid DS/FFH Spread-Spectrum Radio Transceiver

In recent years there has been great interest in using hybrid spread-spectrum (HSS) techniques for commercial applications, particularly in the Smart Grid, in addition to their inherent uses in military communications. This is because HSS can accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A highly useful form of this transmission technique for many types of command, control, and sensing applications is the specific code-related combination of standard direct-sequence modulation with "fast" frequency-hopping, denoted hybrid DS/FFH, wherein multiple frequency hops occur within a single data-bit time. In this paper, we present the efforts carried out at Oak Ridge National Laboratory toward exploring the design, implementation, and evaluation of a hybrid DS/FFH spread-spectrum radio transceiver using a single Field Programmable Gate Array (FPGA). The FPGA allows the various subsystems to quickly communicate with each other and thereby maintain tight synchronization. We also investigate various hopping sequences against robustness to interference and jamming. Experimental results are presented that show the receiver sensitivity, radio data-rate/bit-error evaluations, and jamming and interference rejection capabilities of the implemented hybrid DS/FFH spread-spectrum system under widely varying design parameters.

data rate↗

PTA of Infrapopliteal Arteries: Long-term Clinical Follow-up and Analysis of Factors Influencing Clinical Outcome

This study was a retrospective analysis of patients with CLI who underwent infrapopliteal percutaneous transluminal angioplasty (PTA). The main goal was to evaluate clinical and morphological factors that influence the clinical outcome of PTA in long-term follow-up. A total of 1,445 PTA procedures were performed in 1,268 patients. Main indications for PTA included gangrene, nonhealing ulcers, or rest pain. The mean number of treated arteries was 1.77 artery/limb, and the majority of lesions were type TASC D. The technical success rate of PTA was 89% of intended-to-treat arteries. The main criterion of clinical success was functional limb salvage (LS). One-year follow-up involved 1,069 limbs. Primary and secondary 1-year LS rates were 76.1 and 84.4%, respectively. The effect of clinical and morphological parameters on the 1-year LS was that the only associated disease with an adverse effect on LS rate was DM combined with dialysis. Regarding limb preprocedural status, gangrene was clearly a negative predictor. The most important factor affecting LS was the number of patent arteries post-PTA: patients with 0, 1, 2, and 3 patent arteries had 1-year primary LS rates of 56.4, 73.1, 80.4, and 83%, respectively. Long-term follow-up of LS rates demonstrated secondary LS rates of 84.4, 78.8, and 73.3% at 1, 5, and 10 years. Every effort should be made to perform PTA for as many arteries as possible, even if TASC D type, to improve clinical outcome. Our study shows that repeat PTA is capable of keeping the long-term LS rate close to 75%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of multiple coinflip devices for high-quality random sampling

Artificial intelligence, scientific computing, and probabilistic computing use random sampling to approximate solutions to various problems, with larger models requiring a substantial quantity of random numbers. To generate the required vast quantity of random numbers at high rates, we explore so-called “coinflip” devices, which are stochastic microelectronic devices ideally capable of independently generating random bits with a tunable weight at a high rate. However, coinflip devices are inherently analog and demonstrate nonidealities, like temperature dependence and drift, that can introduce determinism into the outputs. We present important considerations for building systems of multiple coinflip devices to produce high-quality bitstreams with low error and little dependency on previous bits. Using tunnel diodes as coinflip devices, we implement a control loop to adapt to temperature dependence and generate fair bitstreams with each device. While this can lead to dependencies between bits in a single bitstream, we demonstrate that combining results generated in parallel with individual tunnel diodes can produce fair and unpredictable bitstreams. The suitability of these bitstreams for use in probabilistic computing is then demonstrated through a Monte Carlo approximation of π.

Taylor, Brady Garland [Sandia National Laboratorie↗

Investigating high-energy proton-induced reactions on spherical nuclei: Implications for the preequilibrium exciton model

A number of accelerator-based isotope production facilities utilize $100-200$ MeV proton beams due to the high production rates enabled by high-intensity beam capabilities and the greater diversity of isotope production brought on by the long range of high-energy protons. However, nuclear reaction modeling at these energies can be challenging because of the interplay between different reaction modes and a lack of existing guiding cross section data. A Tri-lab collaboration has been formed between the Lawrence Berkeley, Los Alamos, and Brookhaven National Laboratories to address these complexities by characterizing charged-particle nuclear reactions relevant to the production of established and novel radioisotopes. In the inaugural collaboration experiments, stacked-targets of niobium foils were irradiated at the Brookhaven Linac Isotope Producer ($E_p=200$ MeV) and the Los Alamos Isotope Production Facility ($E_p=100$ MeV) to measure $^{93}$Nb(p,x) cross sections between $50-200$ MeV. The results were compared with literature data as well as the default calculations of the nuclear model codes TALYS, CoH, EMPIRE, and ALICE. The default code predictions largely failed to reproduce the measurements. Therefore, we developed a standardized procedure, which determines the reaction model parameters that best reproduce the most prominent reaction channels in a physically justifiable manner. Overall, the primary focus of the procedure was to determine the best parameterization for the pre-equilibrium two-component exciton model. This modeling study revealed a trend towards a relative decrease for internal transition rates at intermediate proton energies ($E_p=20-60$ MeV) in the current exciton model as compared to the default values. The results of this work are instrumental for the planning, execution, and analysis essential to isotope production.

43 PARTICLE ACCELERATORS↗

Advanced Reflector and Absorber Materials (Fact Sheet)

Fact sheet describing NREL CSP Program capabilities in the area of advanced reflector and absorber materials: evaluating performance, determining degradation rates and lifetime, and developing new coatings.

14 SOLAR ENERGY↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Final Report: Part 1. In-Place Filter Testing Instrument for Nuclear Material Containers. Part 2. Canister Filter Test Standards for Aerosol Capture Rates.

A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canister integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair) fouling of o-rings, (B) leakage through simulated cracks in o-rings, and (C) air leakage due to inadequately tightened canister lids. The Los Alamos POC instrument determined pertinent air flow and pressure quantities, and this knowledge was used to specify a customized Isaac® (Z axis, Salt Lake City, UT) leak test module. The final Los Alamos IPFT (incorporating the Isaac® leak test module) was used to repeat the tests in the Instrument Development Plan (with simulated filter clogging tests and canister leak pathway tests). The Los Alamos IPFT instrument is capable of determining filter clogging and leak rate conditions, without requiring removal of the container lid. The IPFT measures pressure decay rate from 1.7E-03 in WC/sec to 1.7E-01 in WC/sec. On the same unit scale, helium leak testing of canisters has a range from 5.7E-07 in WC/sec to 1.9E-03 in WC/sec. For a 5-quart storage canister, the IPFT measures equivalent leak flow rates from 0.03 to 3.0 cc/sec. The IPFT does not provide the same sensitivity as helium leak testing, but is able to gauge the assembled condition of as-found and in-situ canisters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shock compression of condensed matter using Eulerian multimaterial method: Applications to multidimensional shocks, deflagration, detonation, and laser ablation

The reactive flow analysis of high energy material is performed using hydro shock compression of condensed matter (SCCM) tool that is being developed for handling complex multimaterial dynamics involving energetic and inert matters. Typically, the reacting flows of high energy materials such as fires and explosions give rise to strong nonlinear shock waves and high strain rate deformation of metallic confinements at unusually high pressure and temperature. In order to address difficulties associated with analyzing such complex systems, we have developed a suite of modeling capabilities for elegantly handling large gradients and high strain rates in solids as well as reactive shock waves present in gaseous phase. Mathematical formulation of explosive dynamics involving condensed matter is explained with an emphasis on validating and application of hydro-SCCM to a series of problems of high-speed multimaterial dynamics in nature. A detailed numerical description of a level-set based reactive ghost fluid approach is reported in a separate paper.

36 MATERIALS SCIENCE↗

Oxygen generator for medical applications (USIC)

The overall Project objective is to develop a portable, non-cryogenic oxygen generator capable of supplying medical grade oxygen at sufficient flow rates to allow the field application of the Topical Hyperbaric Oxygen Therapy (THOT{reg_sign}) developed by Numotech, Inc. This project was sponsored by the U.S. Department of Energy Global Initiatives for Proliferation Prevention (GIPP) and is managed by collaboration between Sandia National Laboratories (SNL), Numotech, Inc, and LLC SPE 'Spektr-Conversion.' The project had two phases, with the objective of Phase I being to develop, build and test a laboratory prototype of the membrane-pressure swing adsorber (PSA) system producing at 15 L/min of oxygen with a minimum of 98% oxygen purity. Phase II objectives were to further refine and identify the pre-requisites needed for a commercial product and to determine the feasibility of producing 15 L/min of oxygen with a minimum oxygen purity of 99%. In Phase I, Spektr built up the necessary infrastructure to perform experimental work and proceeded to build and demonstrate a membrane-PSA laboratory prototype capable of producing 98% purity oxygen at a flow rate of 5 L/min. Spektr offered a plausible path to scale up the process for 15 L/min. Based on the success and experimental results obtained in Phase I, Spektr performed work in three areas for Phase II: construction of a 15 L/min PSA; investigation of compressor requirements for the front end of the membrane/PSA system; and performing modeling and simulation of assess the feasibility of producing oxygen with a purity greater than 99%. Spektr successfully completed all of the tasks under Phase II. A prototype 15 L/min PSA was constructed and operated. Spektr determined that no 'off the shelf' air compressors met all of the specifications required for the membrane-PSA, so a custom compressor will likely need to be built. Modeling and simulation concluded that production of oxygen with purities greater than 99% was possible using a Membrane-PSA system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗