A Polarimetric Approach for Constraining the Dynamic Foreground Spectrum for Cosmological Global 21 cm Measurements

The cosmological global (sky-averaged) 21 cm signal is a powerful tool to probe the evolution of the intergalactic medium in high-redshift universe (z⩽6). One of the biggest observational challenges is to remove the foreground spectrum which is at least four orders of magnitude brighter than the cosmological 21 cm emission. Conventional global 21 cm experiments rely on the spectral smoothness of the foreground synchrotron emission to separate it from the unique 21 cm spectral structures in a single total-power spectrum. However, frequency-dependent instrumental and observational effects are known to corrupt such smoothness and complicate the foreground subtraction. We introduce a polarimetric approach to measure the projection-induced polarization of the anisotropic foreground onto a stationary dual-polarized antenna. Due to Earth rotation, when pointing the antenna at a celestial pole, the revolving foreground will modulate this polarization with a unique frequency-dependent sinusoidal signature as a function of time. In our simulations, by harmonic decomposing this dynamic polarization, our technique produces two separate spectra in parallel from the same observation: (i) a total sky power consisting both the foreground and the 21 cm background and (ii) a model-independent measurement of the foreground spectrum at a harmonic consistent to twice the sky rotation rate. In the absence of any instrumental effects, by scaling and subtracting the latter from the former, we recover the injected global 21 cm model within the assumed uncertainty. We further discuss several limiting factors and potential remedies for future implementation.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining the Physical State of the Hot Gas Halos in NGC 4649 and NGC 5846

We present results of a joint Chandra/XMM-Newton analysis of the early-type galaxies NGC 4649 and NGC 5846 aimed at investigating differences between mass profiles derived from X-ray data and those from optical data, to probe the state of the hot interstellar medium (ISM) in these galaxies. If the hot ISM is at a given radius in hydrostatic equilibrium (HE), the X-ray data can be used to measure the total enclosed mass of the galaxy. Differences from optically derived mass distributions therefore yield information about departures from HE in the hot halos. The X-ray mass profiles in different angular sectors of NGC 4649 are generally smooth with no significant azimuthal asymmetries within 12 kpc. Extrapolation of these profiles beyond this scale yields results consistent with the optical estimate. However, in the central region (r<3 kpc) the X-ray data underpredict the enclosed mass, when compared with the optical mass profiles. Consistent with previous results, we estimate a nonthermal pressure component accounting for 30% of the gas pressure, likely linked to nuclear activity. In NGC 5846 the X-ray mass profiles show significant azimuthal asymmetries, especially in the NE direction. Comparison with optical mass profiles in this direction suggests significant departures from HE, consistent with bulk gas compression and decompression due to sloshing on ∼15 kpc scales; this effect disappears in the NW direction, where the emission is smooth and extended. In this sector we find consistent X-ray and optical mass profiles, suggesting that the hot halo is not responding to strong nongravitational forces.

79 ASTRONOMY AND ASTROPHYSICS↗

Lensing and the Warm-hot Intergalactic Medium

The correlation of weak lensing and Cosmic Microwave Anisotropy (CMB) data traces the pressure distribution of the hot, ionized gas and the underlying matter density field. The measured correlation is dominated by baryons residing in halos. Detecting the contribution from unbound gas by measuring the residual cross-correlation after masking all known halos requires a theoretical understanding of this correlation and its dependence with model parameters. Our model assumes that the gas in filaments is well described by a log-normal probability distribution function, with temperatures 10{sup 5–7} K and overdensities ξ ≤ 100. The lensing-Comptonization cross-correlation is dominated by gas with overdensities in the range ξ ≈ [3–33]; the signal is generated at redshifts z ≤ 1. If only 10% of the measured cross-correlation is due to unbound gas, then the most recent measurements set an upper limit of T-bar {sub e}≲10{sup 6} K on the mean temperature of the intergalactic Medium. The amplitude is proportional to the baryon fraction stored in filaments. The lensing-Comptonization power spectrum peaks at a different scale than the gas in halos, making it possible to distinguish both contributions. To trace the distribution of the low-density and low-temperature plasma on cosmological scales, the effect of halos will have to be subtracted from the data, requiring observations with larger signal-to-noise ratios than are currently available.

79 ASTRONOMY AND ASTROPHYSICS↗

The Impact of Void-finding Algorithms on Galaxy Classification

We explore how the definition of a void influences the conclusions drawn about the impact of the void environment on galactic properties using two void-finding algorithms in the Void Analysis Software Toolkit: Voronoi Voids (V 2 ), a Python implementation of ZOnes Bordering On Voidness (ZOBOV); and VoidFinder, an algorithm that grows and merges spherical void regions. Using the Sloan Digital Sky Survey Data Release 7, we find that galaxies found in VoidFinder voids tend to be bluer and fainter and to have higher (specific) star formation rates than galaxies in denser regions. Conversely, galaxies found in V 2 voids show less significant differences when compared to galaxies in denser regions, less consistent with the large-scale environmental effects on galaxy properties expected from both simulations and previous observations. These results align with previous simulation results that show V 2 -identified voids “leak” into the dense walls between voids because their boundaries extend up to the density maxima in the walls. As a result, when using ZOBOV-based void-finders, galaxies likely to be part of wall regions are instead classified as void galaxies, a misclassification that can be critical to our understanding of galaxy evolution.

cosmic web↗

Effects of the large-scale circulation on temperature and water vapor distributions in the Π Chamber

Abstract. Microphysical processes are important for the development of clouds and thus Earth's climate. For example, turbulent fluctuations in the water vapor mixing ratio, r, and temperature, T, cause fluctuations in the saturation ratio, S. Because S is the driving factor in the condensational growth of droplets, fluctuations may broaden the cloud droplet size distribution due to individual droplets experiencing different growth rates. The small-scale turbulent fluctuations in the atmosphere that are relevant to cloud droplets are difficult to quantify through field measurements. We investigate these processes in the laboratory using Michigan Tech's Π Chamber. The Π Chamber utilizes Rayleigh–Bénard convection (RBC) to create the turbulent conditions inherent in clouds. In RBC it is common for a large-scale circulation (LSC) to form. As a consequence of the LSC, the temperature field of the chamber is not spatially uniform. In this paper, we characterize the LSC in the Π Chamber and show how it affects the shape of the distributions of r, T, and S. The LSC was found to follow a single roll with an updraft and downdraft along opposing walls of the chamber. Near the updraft (downdraft), the distributions of T and r were positively (negatively) skewed. At each measuring position, S consistently had a negatively skewed distribution, with the downdraft being the most negative.

54 ENVIRONMENTAL SCIENCES↗

Wind-tunnel boundary interference for V/STOL TESTING

The wake skew angle used in applying the theory of NASA TR R-124 to data correction should be such that the angular deflection of the wake vorticity from the horizontal is one-half that calculated from momentum theory at the lifting element. This usage is in contrast to that of the original paper which used the angle of the mass flow. Because of large-scale recirculation effects, there is a finite lower limit to the test speed at which reliable and correctable data can be obtained in closed wind tunnels. Although a zero-correction wind tunnel for V/STOL testing has not yet been achieved, it is shown that the use of suitably mixed wind-tunnel boundaries can alleviate boundary effects on V/STOL data.

V/STOL AIRCRAFT↗

Development of mathematical models of environmental physiology

Selected articles concerned with mathematical or simulation models of human thermoregulation are presented. The articles presented include: (1) development and use of simulation models in medicine, (2) model of cardio-vascular adjustments during exercise, (3) effective temperature scale based on simple model of human physiological regulatory response, (4) behavioral approach to thermoregulatory set point during exercise, and (5) importance of skin temperature in sweat regulation.

Stolwijk, J. A. J.↗

Investigation of the effect of inlet turbulence length scale on fan discrete tone noise

Results of an experimental investigation at the Ames 40- by 80-Foot Wind Tunnel of fan rotor alone discrete tone noise is presented. The investigation examines rotor interaction with fan inlet turbulence. The importance of turbulence length scale is shown by comparing the fan radiated acoustic spectrum with and without modified turbulence length scales. A small-scale low pressure ratio fan was used for the experiment.

Hodder, B. K.↗

Recent advances in elastomer service-life prediction

The mechanical properties of an elastomer, including rupture and its time dependence, are defined uniquely by a tensile property surface in normalized stress-strain-time coordinates. In practice, the property surface is determined from short-time constant strain-rate uniaxial tests. By using the time reduction properties of both temperature and cross-link density, an effective time scale of over ten decades of log time can be covered. Changes in cross-link density, filler content, or swelling do not affect the limits of the property surface when plotted in logarithmic coordinates but merely shift their positions. The shape, however, may be modified in certain cases. The service life of an elastomer in the absence of aging reactions can be estimated from the property surface and expected in-use conditions such as strains (static or dynamic).

Landel, R. F.↗

Measurements of wave height statistics and radar, cross-section in a wind wave tank

There is currently wide interest among oceanographers and meteorologists in remote sensing of ocean surface characteristics. A wind wave tank developed at Langley Research Center is used to evaluate various remote sensing techniques based on electromagnetic scattering phenomena, and in the development and evaluation of theoretical scattering models. The wave tank is described, the statistics of the rough water surface are documented, and microwave radar cross-section measurement results are presented. The water surface statistics are similar in key respects to the open ocean, and the microwave scattering measurements show, qualitatively, theoretically predicted large and small scale scattering effects.

Johnson, J. W.↗

A wind tunnel technique for determining stability derivatives from cable mounted aeroelastic models

System identification techniques in common use for extracting stability derivatives from flight test data have been adapted for application to data obtained from aeroelastically-scaled flutter models flown in a wind tunnel on a cable mount system. The concept has been applied with reasonable success to data from rigid models of a Space Shuttle Orbiter and a fighter tested in the NASA Langley transonic dynamics tunnel. Further application of this technique should permit extraction of derivatives that include scaled flexibility effects, thereby obtaining additional information from the testing of expensive flutter models.

Bennett, R. M.↗

Evaluation of a low aspect ratio small axial compressor stage, volume 1

A program was conducted to evaluate the effects of scaling, tip clearance, and IGV reset on the performance of a low aspect ratio compressor stage. Stage design was obtained by scaling an existing single stage compressor by a linear factor of 0.304. The design objective was to maintain the meanline velocity field of the base machine in the smaller size. Adjustments were made to account for predicted blockage differences and to chord lengths and airfoil edge radii to obtain reasonable blade geometries. Meanline velocity diagrams of the base stage were not maintained at the scaled size. At design speed and flowrate the scaled stage achieved a pressure ratio of 1.423, adiabatic efficiency of 0.822, and surge margin of 18.5%. The corresponding performance parameters for the base stage were 1.480, 0.872, and 25.2%, respectively. The base stage demonstrated a peak efficiency at design speed of 0.872; the scaled stage achieved a level of 0.838. When the scaled stage rotor and stator tip clearances were doubled, the stage achieved a pressure ratio of 1.413, efficiency of 0.799, and surge margin of 16.0% at the design flowrate. The peak stage efficiency at design speed was 0.825 with the increased clearance. Increased prewhirl lowered the stage pressure ratio as expected. Stage efficiency was maintained with ten degrees of increased prewhirl and then decreased substantially with ten additional degrees of reset.

Sawyer, C. W., III↗

Effect of physical aging on stress relaxation of poly/methyl methacrylate/

A study was made on the stress relaxation behavior at 25 C of poly(methyl methacrylate) in uniaxial tension as a function of physical aging at both room temperature and 60 C. Test specimens were compression molded at 165 C, then quenched to room temperature and allowed to age for up to 30 days prior to testing. Stress relaxation curves measured after different aging times could be superposed to a single master curve for each aging temperature. Superposition was achieved by applying vertical and horizontal shifts. Hence, the shape of the response curves was not changed by aging. This is in accordance with observations made by Struik for tensile creep curves. Volume changes as a function of physical aging were also determined. Simple exponential relationships were observed between volume and both horizontal and vertical shifts. The horizontal shift implies a shift in the effective time scale caused by a change in free volume. The vertical shifts could be correlated with changes in Young's modulus caused by a change in density. For the range of aging studied, the response time scale varied over nearly two decades of log-time. For the same conditions modulus varied by 30 percent.

Cizmecioglu, M.↗

Axial-compressor flow distortion with water ingestion

The objective of the investigation is as follows: to establish relations between the steady state mean flow distortion generated during water ingestion into an axial-flow compressor and (a) characteristic length and time scales pertaining to (1) the centrifugal action and (2) the heat and mass transfer processes and (b) aerodynamic parameters based on blade geometry, aspect ratio and blade loading. Analytical and experimental results are presented for a small compressor to illustrate the extent of the distortion introduced as a function of (1) the operating speed and (2) the mass-based water content in the ingested mixture. Methods of scaling the effects in compressors of different sizes are discussed.

Tsuchiya, T.↗

The detection of H2 in cool carbon stars

Spectra of several carbon stars in the two micron region are examined and compared with synthetic spectra from model atmospheres. Molecular hydrogen has been directly observed in carbon stars for the first time through the quadrupole 1-0 S(1) line at 4712.9/cm. It is definitely present in several Mira variables, and is definitely not present in several irregular variables and one Mira variable. A discrepancy between the predicted and observed line depths at different temperatures is shown. Resolution of the discrepancy by change of temperature alone would require an upward revision of the present effective temperature scale by at least 600 K. Several possible resolutions of the dilemma are briefly examined.

Goebel, J. H.↗

Space shuttle orbiter reaction control subsystem flight data anomalies

Shuttle orbiter vehicle flight data obtained during operation of the reaction control subsystem (RCS) were compared with predictions derived from RCS wind tunnel test data. This paper reviews the derivation of the wind tunnel data base and discusses how it was used to predict the full-scale RCS effects. Flight and predicted data comparisons include the lateral and directional aerodynamic effects of firing the side jets, longitudinal aerodynamics for pitch jets, and lateral aerodynamics for roll jets. Flight data anomalies resulting from wind tunnel limitations in representing portions of the entry flight trajectory are presented. The cause of each data anomaly is described, as well as a requirement for additional technical analysis to establish RCS effect simulation parameters that can be used to update jet effect technology.

Stone, J. S.↗

Electrons, muons and hadrons in extensive air showers and how do they depend on nuclear interaction model, part 2

Some of the results of Monte Carlo simulations of extensive air showers for nuclear interactions models are presented. The most significant part of scaling violation effect is generated by the inclusion of rising cross-section. Among the models considered the lowest value for Eo/N(max) is obtained when rapidly rising cross-section and charge exchange are both included (model R-F01). The value is still 1.38 GeV/electron. Except at the highest energies, the sensitivity to atomic mass of the primary is greater than to specific assumptions about multiple production.

Wrotniak, J. A.↗