Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Embedding of Fiber Optic Sensors in Stainless Steel for Sensing in Harsh Environments

Structural health monitoring is critical for components working in harsh environments to assess their safety and integrity. This can be realized with advanced sensors, such as fiber optic sensors, embedded in these components. Recent studies have used ultrasonic consolidation (UC) and laser-based additive manufacturing (AM) techniques to embed fiber optic sensors in metals. However, sensor embedding using these techniques has been challenging, with gaps and voids around the embedded fiber. Successful embedding of fiber optic sensors requires good contact between the fiber and the matrix to eliminate potential gas/liquid leaks in critical systems such as in nuclear and aerospace services. Defect-free fiber/matrix bond is also essential for accurate measurement of parameters of interest, such as temperature and strain. This study developed a novel fiber embedding technique based on electric field-assisted sintering (EFAS). Sapphire optical fibers with diameters of 125 µm and 250 µm were embedded in stainless steel (SS) 316L using EFAS. The embedding was completed by sintering SS 316L powders at a pressure of 50MPa, hold time of 5 min, and temperatures of 1000°C, 1100°C, and 1200°C. Joule heating mechanism during EFAS enabled rapid sintering of the SS 316L powder with resulting sample densities over 99%. Microscopy analysis performed on the cross-sections revealed a defect-free bond between the embedded fiber and SS 316L. The good integrity of the embedded fiber was evidenced by optical transmittance measurement. Optical attenuation of the fiber before and after embedment was examined in the near-infrared region. Scanning electron microscopy was employed to investigate the grain morphology of SS 316L near the embedded fiber. Hardness distribution in the sintered part was also investigated to study the effect of the embedded fiber on the mechanical properties of the as-fabricated component. The results indicated that EFAS was able to embed fiber in SS with good fiber functionality and part quality.

36 - MATERIALS SCIENCE↗

Multi-Wavelength Based Optical Density Sensor for Autonomous Monitoring of Microalgae

A multi-wavelength based optical density sensor unit was designed, developed, and evaluated to monitor microalgae growth in real time. The system consisted of five main components including (1) laser diode modules as light sources (2) photodiodes as detectors, (3) driver circuit, (4) flow cell and (5) sensor housing temperature controller. The sensor unit was designed to be integrated into any microalgae culture system for both real time and non-real time optical density measurements and algae growth monitoring applications. It was shown that the sensor unit was capable of monitoring the dynamics and physiological changes of the microalgae culture in real-time. Algae biomass concentration was accurately estimated with optical density measurements at 650, 685 and 780 nm wavelengths used by the sensor unit. The sensor unit was able to monitor cell concentration as high as 1.05 g L -1 (1.51x10 8 cells mL -1 ) during the culture growth without any sample preparation for the measurements. Since high cell concentrations do not need to be diluted using the sensor unit, the system has the potential to be used in industrial microalgae cultivation systems for real time monitoring and control applications that can lead to improved resource use efficiency.

09 BIOMASS FUELS↗

A miniature 48-channel pressure sensor module capable of in situ calibration

A new high data rate pressure sensor module with in situ calibration capability has been developed by the Langley Research Center to help reduce energy consumption in wind-tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. This module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by sensors. The small size of the sensor module will allow mounting within many wind-tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

Electronically scanned pressure sensor module with in SITU calibration capability

This high data rate pressure sensor module helps reduce energy consumption in wind tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. The module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by the sensors. The small size of the sensor module will allow mounting within many wind tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

Magnetic Field Response Measurement Acquisition System

Magnetic field response sensors designed as passive inductor- capacit or circuits produce magnetic field responses whose harmonic frequenci es correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induc tion. A radio frequency antenna produces the time varying magnetic fi eld used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for disce rning changes in sensor's response frequency, resistance and amplitud e is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminat ing the need to have a data acquisition channel dedicated to each se nsor. The method does not require the sensors to be in proximity to a ny form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

Woodward, Stanley E.↗

On requirements for a satellite mission to measure tropical rainfall

Tropical rainfall data are crucial in determining the role of tropical latent heating in driving the circulation of the global atmosphere. Also, the data are particularly important for testing the realism of climate models, and their ability to simulate and predict climate accurately on the seasonal time scale. Other scientific issues such as the effects of El Nino on climate could be addressed with a reliable, extended time series of tropical rainfall observations. A passive microwave sensor is planned to provide information on the integrated column precipitation content, its areal distribution, and its intensity. An active microwave sensor (radar) will define the layer depth of the precipitation and provide information about the intensity of rain reaching the surface, the key to determining the latent heat input to the atmosphere. A visible/infrared sensor will provide very high resolution information on cloud coverage, type, and top temperatures and also serve as the link between these data and the long and virtually continuous coverage by the geosynchronous meteorological satellites. The unique combination of sensor wavelengths, coverages, and resolving capabilities together with the low-altitude, non-Sun synchronous orbit provide a sampling capability that should yield monthly precipitation amounts to a reasonable accuracy over a 500- by 500-km grid.

Thiele, Otto W.↗

Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction

Purpose: In image-guided surgery (IGS) intraoperative image acquisition of tissue shape, motion, and morphology is one of the main challenges. Recently, time-of-flight (ToF) cameras have emerged as a new means for fast range image acquisition that can be used for multimodal registration of the patient anatomy during surgery. The major drawbacks of ToF cameras are systematic errors in the image acquisition technique that compromise the quality of the measured range images. In this paper, we propose a calibration concept that, for the first time, accounts for all known systematic errors affecting the quality of ToF range images. Laboratory and in vitro experiments assess its performance in the context of IGS.Methods: For calibration the camera-related error sources depending on the sensor, the sensor temperature and the set integration time are corrected first, followed by the scene-specific errors, which are modeled as function of the measured distance, the amplitude and the radial distance to the principal point of the camera. Accounting for the high accuracy demands in IGS, we use a custom-made calibration device to provide reference distance data, the cameras are calibrated too. To evaluate the mitigation of the error, the remaining residual error after ToF depth calibration was compared with that arising from using the manufacturer routines for several state-of-the-art ToF cameras. The accuracy of reconstructed ToF surfaces was investigated after multimodal registration with computed tomography (CT) data of liver models by assessment of the target registration error (TRE) of markers introduced in the livers.Results: For the inspected distance range of up to 2 m, our calibration approach yielded a mean residual error to reference data ranging from 1.5 ± 4.3 mm for the best camera to 7.2 ± 11.0 mm. When compared to the data obtained from the manufacturer routines, the residual error was reduced by at least 78% from worst calibration result to most accurate manufacturer data. After registration of the CT data with the ToF data, the mean TRE ranged from 3.7 ± 2.1 mm for point-based and 5.7 ± 1.9 mm for surface-based registration for the best camera to 6.2 ± 3.4 and 11.1 ± 2.8 mm, respectively. Compared to data provided by the manufacturer, the mean TRE decreased by 8%–60% for point-based and by 18%–74% for surface-based registration.Conclusions: Using the proposed calibration approach improved the measurement accuracy of all investigated ToF cameras. Although evaluated in the context of intraoperative image acquisition, the proposed calibration procedure can easily be applied to other medical applications using ToF cameras, such as patient positioning or respiratory motion tracking in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical fiber evanescent wave adsorption sensors for high-temperature gas sensing in advanced coal-fired power plants

Modern advanced energy systems such as coal-fired power plants, gasifiers, or similar infrastructure present some of the most challenging harsh environments for sensors. The power industry would benefit from new, ultra-high temperature devices capable of surviving in hot and corrosive environments for embedded sensing at the highest value locations. For these applications, we are currently exploring optical fiber evanescent wave absorption spectroscopy (EWAS) based sensors consisting of high temperature core materials integrated with novel high temperature gas sensitive cladding materials. Mathematical simulations can be used to assist in sensor development efforts, and we describe a simulation code that assumes a single thick cladding layer with gas sensitive optical constants. Recent work has demonstrated that Au nanoparticle-incorporated metal oxides show a potentially useful response for high temperature optical gas sensing applications through the sensitivity of the localized surface plasmon resonance absorption peak to ambient atmospheric conditions. Hence, the simulation code has been applied to understand how such a response can be exploited in an optical fiber based EWAS sensor configuration. We demonstrate that interrogation can be used to optimize the sensing response in such materials.

01 COAL, LIGNITE, AND PEAT↗

Two-level Clustering-based Target Detection Through Sensor Deployment and Data Fusion

Target detection is one fundamental problem in many sensor network-based applications, which is typically tackled in two separate stages for sensor deployment and data fusion. We propose an integrated solution, referred to as 2C-SSEM,which combines 2-level clustering-based sensor deployment and source strength estimate map-based data fusion for the detection of a single static or moving target. 2C-SSEM conducts the first level of clustering to determine a sensor deployment scheme and the second level of clustering to divide the deployed sensors into several subsets. For each sensor, the source strength is estimated at each grid point of the entire region based on a signal attenuation model, and for each subset of sensors, the target location is estimated using a distribution map-based statistical analysis method. A final detection decision is made by thresholding the clustering degree of the target location estimates computed by all subsets of sensors. Compared with traditional grid-based target detection methods, 2C-SSEM significantly reduces the computation complexity and improves the detection performance through an integrated optimization strategy. Extensive simulation results show the performance superiority of the proposed solution over several well-known methods for target detection.

Rao, Nageswara↗

Room Temperature Carbon Nanotube Based Sensor for Carbon Monoxide Detection

Sulfonated single-walled carbon nanotubes have been used in an integrated electrode structure forthe detection of carbon monoxide. The sensor responds to 0.5 ppm of CO in air at room temperature. All eightsensors with this material in a 32-sensor array showed good repeatability and reproducibility, with response andrecovery times of about 10 s. Pristine nanotubes generally do not respond to carbon monoxide and the resultshere confirm sulfonated nanotubes to be a potential candidate for the construction of an electronic nose thatrequires at least a few materials for the selective detection of CO.

Nanomaterial functionalization↗

Semiconductor-compatible topological digital alloys

Recently, GeSn alloys have attracted much interest for direct-gap infrared photonics and as potential topological materials which are compatible with the semiconductor industry. However, for photonics, the high-Sn content required leads to low detectivity, associated with poor material quality, and the (>35 %) Sn required for topological properties have been out of reach experimentally. Here, we demonstrate that by patterning the Sn distribution within Ge, the electronic properties have a far greater tunability than is possible with the random alloy. For the GeSn δ-digital alloy (DA) formed by confining Sn atoms in atomic layer(s) along the [111] direction of Ge, we show that ∼ 10 % Sn can lead to a triple-point semimetal. These findings are understood in terms of Sn ordering causing spatial separation of Sn and Ge band edges, leading to band inversion. This mechanism can also lead to a weak topological insulator, Weyl semimetal, and enables tunable direct bandgaps down to 2 meV, covering the entire infrared range. This DA induced topological properties are also identified in compound semiconductors, such as InAs 1-x Sb x , showing the general applicability of the DA design for realizing topological properties on conventional semiconductor platforms. Furthermore, our findings not only point to a new class of currently unexplored topological systems accessible by epitaxy, but also establish the promise of low-Sn GeSn DAs for application as infrared laser diodes and photodetectors in Si photonic integrated circuits and infrared image sensors.

3D topological semimetal↗

Self-powered ocean buoy using a disk-type triboelectric nanogenerator with a mechanical frequency regulator

Triboelectric nanogenerator (TENG) systems have been demonstrated to generate power with high density. However, the electrical output power obtained from wave energy harvesting using TENG systems is typically limited to several milliwatts. To address this limitation and support various ocean buoy systems, an efficient method to scale-up TENG systems is required. In this paper, we present a self-powered ocean buoy (SPOB) incorporating a disk-type, soft-contact, mechanical frequency regulator TENG (DSMFR-TENG). The mechanical frequency regulator (MFR) enables the conversion of low-frequency wave energy to high-speed mechanical rotation, facilitating high power generation with the disk-type TENG. Here, the SPOB was tested in a wave tank, reaching a peak power output of 470 mW and an average power output of 130 mW after the MFR released the rotational energy. To further enhance the functionality of the buoy, the DSMFR-TENG and a microcontroller, temperature sensor, and acoustic transmitter were integrated with the SPOB. The acoustic transmitter successfully transmitted signals 7, 23, and 30 times over a one-minute period at wave frequencies of 0.33 Hz, 0.5 Hz, and 1 Hz, respectively, thereby demonstrating the power supply capability of the TENG system for ocean buoys.

42 ENGINEERING↗

3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature

Real-time detection of basic physiological parameters such as blood pressure and heart rate is an important target in wearable smart devices for healthcare. Among these, the core body temperature is one of the most important basic medical indicators of fever, insomnia, fatigue, metabolic functionality, and depression. However, traditional wearable temperature sensors are based upon the measurement of skin temperature, which can vary dramatically from the true core body temperature. Here, we demonstrate a three-dimensional (3D) printed wearable "earable" smart device that is designed to be worn on the ear to track core body temperature from the tympanic membrane (i.e., ear drum) based on an infrared sensor. The device is fully integrated with data processing circuits and a wireless module for standalone functionality. Using this smart earable device, we demonstrate that the core body temperature can be accurately monitored regardless of the environment and activity of the user. In addition, a microphone and actuator are also integrated so that the device can also function as a bone conduction hearing aid. Using 3D printing as the fabrication method enables the device to be customized for the wearer for more personalized healthcare. This smart device provides an important advance in realizing personalized health care by enabling real-time monitoring of one of the most important medical parameters, core body temperature, employed in preliminary medical screening tests.

47 OTHER INSTRUMENTATION↗

Waterproof AlInGaP optoelectronics on stretchable substrates with applications in biomedicine and robotics

Inorganic light-emitting diodes and photodetectors represent important, established technologies for solid-state lighting, digital imaging and many other applications. Eliminating mechanical and geometrical design constraints imposed by the supporting semiconductor wafers can enable alternative uses in areas such as biomedicine and robotics. Here we describe systems that consist of arrays of interconnected, ultrathin inorganic light-emitting diodes and photodetectors configured in mechanically optimized layouts on unusual substrates. Light-emitting sutures, implantable sheets and illuminated plasmonic crystals that are compatible with complete immersion in biofluids illustrate the suitability of these technologies for use in biomedicine. Waterproof optical-proximity-sensor tapes capable of conformal integration on curved surfaces of gloves and thin, refractive-index monitors wrapped on tubing for intravenous delivery systems demonstrate possibilities in robotics and clinical medicine. Furthermore, these and related systems may create important, unconventional opportunities for optoelectronic devices.

36 MATERIALS SCIENCE↗

Simultaneous electrical recording of cardiac electrophysiology and contraction on chip

Prevailing commercialized cardiac platforms for in vitro drug development utilize planar microelectrode arrays to map action potentials, or impedance sensing to record contraction in real time, but cannot record both functions on the same chip with high spatial resolution. We report a novel cardiac platform that can record cardiac tissue adhesion, electrophysiology, and contractility on the same chip. The platform integrates two independent yet interpenetrating sensor arrays: a microelectrode array for field potential readouts and an interdigitated electrode array for impedance readouts. Together, these arrays provide real-time, non-invasive data acquisition of both cardiac electrophysiology and contractility under physiological conditions and under drug stimuli. Furthermore, we cultured human induced pluripotent stem cell-derived cardiomyocytes as a model system, and used to validate the platform with an excitation–contraction decoupling chemical. Preliminary data using the platform to investigate the effect of the drug norepinephrine are combined with computational efforts. Finally, this platform provides a quantitative and predictive assay system that can potentially be used for comprehensive assessment of cardiac toxicity earlier in the drug discovery process.

59 BASIC BIOLOGICAL SCIENCES↗

Upconversion luminescence, ferroelectrics and piezoelectrics of Er Doped SrBi{sub 4}Ti{sub 4}O{sub 15}

Er{sup 3+} doped SrBi{sub 4}Ti{sub 4}O{sub 15} (SBT) bismuth layered-structure ferroelectric ceramics were synthesized by the traditional solid-state method, and their upconversion photoluminescent (UC) properties were investigated as a function of Er{sup 3+} concentration and incident pump power. Green (555 nm) and red (670 nm) emission bands were obtained under 980 nm excitation at room temperature, which corresponded to the radiative transitions from {sup 4}S{sub 3/2}, and {sup 4}F{sub 9/2} to {sup 4}I{sub 15/2}, respectively. The emission color of the samples could be changed with moderating the doping concentrations. The dependence of UC intensity on pumping power indicated a two-photon emission process. Studies on dielectric properties indicated that the introduction of Er increased the ferroelectric-paraelectric phase transition temperature (Tc) of SBT, thus making this ceramic suitable for piezoelectric sensor applications at higher temperatures. Piezoelectric measurement showed that the doped SBT had a relative higher piezoelectric constant d{sub 33} compared with the non-doped ceramics. The thermal annealing behaviors of the doped sample revealed a stable piezoelectric property. The doped SBT showed bright UC emission while simultaneously having increased Tc and d{sub 33}. As a multifunctional material, Er doped SBT ferroelectric oxide showed great potential in application of sensor, future optical-electro integration and coupling devices.

36 MATERIALS SCIENCE↗

Fabrication and characterization of p-channel Si double quantum dots

Lithographically defined p-channel Si single hole transistors (SHTs) and double quantum dot (DQD) devices are fabricated and characterized. Coulomb oscillations are clearly evident at a temperature of 4.2 K. The charging energy and the diameter of the SHT are estimated from the Coulomb diamonds. Honeycomb-like charge stability diagrams are observed from measurements of the DQD devices. Single hole transitions through the DQD are detected using an integrated SHT as a charge sensor, and a few-hole regime of the DQD is observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Incubating advances in integrated photonics with emerging sensing and computational capabilities

As photonic technologies grow in multidimensional aspects, integrated photonics holds a unique position and continuously presents enormous possibilities for research communities. Applications include data centers, environmental monitoring, medical diagnosis, and highly compact communication components, with further possibilities continuously growing. Herein, we review state-of-the-art integrated photonic on-chip sensors that operate in the visible to mid-infrared wavelength region on various material platforms. Among the different materials, architectures, and technologies leading the way for on-chip sensors, we discuss the optical sensing principles that are commonly applied to biochemical and gas sensing. Our focus is on passive optical waveguides, including dispersion-engineered metamaterial-based structures, which are essential for enhancing the interaction between light and analytes in chip-scale sensors. We harness a diverse array of cutting-edge sensing technologies, heralding a revolutionary on-chip sensing paradigm. Our arsenal includes refractive-index-based sensing, plasmonics, and spectroscopy, which forge an unparalleled foundation for innovation and precision. Furthermore, we include a brief discussion of recent trends and computational concepts, incorporating Artificial Intelligence & Machine Learning (AI/ML) and deep learning approaches over the past few years to improve the qualitative and quantitative analysis of sensor measurements.

Jain, Sourabh (ORCID:0000000279923275)↗