Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Heuristic Evaluation Methods Applied to a Predictive Maintenance Chatbot

The need for an accessible iterative approach for evaluating prospective artificial intelligence (AI)/ML based technologies in the nuclear industry is needed, given the nature of algorithms and rapid advancements. This paper explores existing heuristic design principles for user-centered design and evaluates them based on their relevancy and usefulness for evaluating AI/ ML based technologies. Researchers at the Idaho National Laboratory (INL) have developed a machine learning software application called VIsualization for PrEdictive maintenance Recommendation (VIPER), which is used to help users understand and engage with the tool to learn more about work orders, data used, predictive maintenance, and machine learning (ML) algorithms. Early user research studies used to access VIPER?s technology readiness level have occurred; however, there is room for further improvement of the software through heuristic evaluations along with other methods and user testing. This work describes the applicability of heuristic evaluation methods and cognitive walkthroughs to help ensure human readiness for prospective AI/ ML based applications, using VIPER as a candidate use case. This work supports industry in ensuring that prospective AI/ML based technologies are usable and useful for plant personnel at nuclear power plants, ultimately leading to their safe, reliable, and efficient use. PowerPoint for conference that was reviewed in PRS and LRS PRS/CON-25-05379 and INL/CON-25-82946

99 - GENERAL AND MISCELLANEOUS↗

APPLICATION OF NEURAL NETWORK ALGORITHMS FOR BPM LINEARIZATION

Stripline BPM sensors contain inherent non-linearities, as a result of field distortions from the pickup elements. Many methods have been devised to facilitate corrections, often employing polynomial fitting. The cost of computation makes real-time correction difficult, particulalry when integer math is utilized. The application of neural-network technology, particularly the multi-layer perceptron algorithm, is proposed as an efficient alternative for electrode linearization. A process of supervised learning is initially used to determine the weighting coefficients, which are subsequently applied to the incoming electrode data. A non-linear layer, known as an activation layer, is responsible for the removal of saturation effects. Implementation of a perceptron in an FPGA-based software-defined radio (SDR) is presented, along with performance comparisons. In addition, efficient calculation of the sigmoidal activation function via the CORDIC algorithm is presented.

43 PARTICLE ACCELERATORS↗

TU-E-BRB-01: Overview of DIR Advantages/Challenges and Workflow

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-02: DIR QA Options and Research Development

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-03: Overview of Proposed TG-132 Recommendations

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

A comparison of TPS and different measurement techniques in small-field electron beams

In recent years, small-field electron beams have been used for the treatment of superficial lesions, which requires small circular fields. However, when using very small electron fields, some significant dosimetric problems may occur. In this study, dose distributions and outputs of circular fields with dimensions of 5 cm and smaller, for nominal energies of 6, 9, and 15 MeV from the Siemens ONCOR Linac, were measured and compared with data from a treatment planning system using the pencil-beam algorithm in electron beam calculations. All dose distribution measurements were performed using the Gafchromic EBT film; these measurements were compared with data that were obtained from the Computerized Medical Systems (CMS) XiO treatment planning system (TPS), using the gamma-index method in the PTW VeriSoft software program. Output measurements were performed using the Gafchromic EBT film, an Advanced Markus ion chamber, and thermoluminescent dosimetry (TLD). Although the pencil-beam algorithm is used to model electron beams in many clinics, there is no substantial amount of detailed information in the literature about its use. As the field size decreased, the point of maximum dose moved closer to the surface. Output factors were consistent; differences from the values obtained from the TPS were, at maximum, 42% for 6 and 15 MeV and 32% for 9 MeV. When the dose distributions from the TPS were compared with the measurements from the Gafchromic EBT films, it was observed that the results were consistent for 2-cm diameter and larger fields, but the outputs for fields of 1-cm diameter and smaller were not consistent. In CMS XiO TPS, calculated using the pencil-beam algorithm, the dose distributions of electron treatment fields that were created with circular cutout of a 1-cm diameter were not appropriate for patient treatment and the pencil-beam algorithm is not convenient for monitor unit (MU) calculations in electron dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

IPC-Fusion (Infrastructure Perception and Control (IPC): Multisensor Data Fusion Software) [SWR-25-153]

As part of the National Laboratory of the Rockies' (NLR’s) Infrastructure Perception and Control Laboratory, the IPC-Fusion toolkit provides a probabilistic, scalable, multi-sensor fusion framework that integrates (late-stage fusion) heterogeneous object detection data from traffic sensors to enable robust, real-time tracking of roadway occupants. The algorithmic design of the toolkit is motivated by the need for creating a digital twin of traffic at the edge in a scalable and affordable manner. The software operates by combining object-level measurements (such as position and velocity) from a suite of sensors (such as radar, lidar, camera) using Kalman filtering and probabilistic data association techniques to overcome individual sensor limitations and achieve superior tracking performance in complex traffic zones. The framework addresses key challenges including heterogeneous measurement uncertainties, asynchronous data streams, varying spatiotemporal data resolutions, robust data association, and adaptive object lifecycle management. Validated on real-world traffic intersection data including vehicles and pedestrians, IPC-Fusion demonstrates enhanced tracking reliability across scenarios involving occlusions, sensor failures, and varying traffic densities, supporting the broader IPC initiative's goal of transforming transportation infrastructure through advanced perception capabilities for intelligent transportation systems, traffic safety applications, and autonomous vehicle support.

Sandhu, Rimple [National Laboratory of the Rockies↗

Pre-commercial Demonstration of Direct Non-iterative State Estimator for Operational Use of Synchrophasor Management Systems

The objective of this project was to demonstrate functionality and performance of a Direct Non-iterative State Estimator (DNSE) integrated with NYPA’s Energy Management System (EMS) and with enhanced Real Time Dynamics Monitoring System (RTDMS) synchrophasor platform from Electric Power Group (EPG). DNSE is designed to overcome a major obstacle to operational use of Synchro-Phasor Management Systems (SPMS) by providing to synchrophasor management systems (SPMS) applications a consistent and a complete synchrophasor data foundation in the same way that a traditional EMS State Estimator (SE) provides to EMS applications. Specifically, DNSE is designed to use synchrophasor measurements collected by a central PDC, Supervisory Control and Data Acquisition (SCADA) measurements, and Energy Management System (EMS) network model, to obtain the complete state of the utility’s operating model at rates that are close to the synchrophasor data rates. In this way, the system is comprehensive in that it does not only cover the part of the network that is “visible” via synchrophasors, but also the part that is only “visible” through the SCADA measurements. Visualization needs associated with the use of DNSE results are fulfilled through suitably enhanced Real Time Dynamics Monitoring System (RTDMS), with the enhancements implemented by EPG. This project had the following goals in mind: To advance the deployment of commercial grade DNSE software application that relies on synchrophasor and SCADA data ; Apply DNSE at other utilities, to address a generic and fundamental need for “clean” operational data for synchrophasor applications; Provide means for “live” estimated data access by control system operators; Enhance potential for situational awareness through full system operational model coverage; Sub-second execution rate of the Direct Non-iterative State Estimator, eventually at a near-phasor data rate execution speed, i.e. < 0.1 sec. Anticipated benefits from this projects are: Enhanced reliability and improvements in the economic efficiency of bulk power system planning and operations; Providing “clean” data to other synchrophasor applications; Enhancement of situational awareness by providing the full operational model updated at near synchrophasor rate; A production-grade software tool that incorporate synchrophasor and SCADA data; Provides a basis for development of next generation monitoring and control applications, based on both SCADA and PMU data. Quanta Technology (QT) team worked in collaboration with Electric Power Group (EPG) whose team has enhanced its commercial Real Time Dynamics Monitoring System (RTDMS) to accommodate the requirements posed by DNSE application. EPG also provided its ePDC and Model-less Data Conditioning (PDVC) software for integration with DNSE+. QT developed the system requirements for DNSE; developed system architecture and defined interfaces between internal DNSE components. The core DNSE algorithm with all surrounding interfaces was named DNSE+. Since the DNSE development was done in a simulated system environment, QT used its PMU simulator that was enhanced during this project for development and factory acceptance testing (FAT). SCADA data in this stage was simulated by commercial PSS/e software. The output of DNSE are estimates of System states in C37.118-2 format, sent to RTDMS for further processing and display. As the number of these states is large, it was necessary to expand the C37.111-2 standard to accommodate large data sets. This enhancement was implemented in RTDMS. The demonstration of pre-production DNSE technology was done at NYPA using streaming field data from NYPA PMUs and from its RTUs through their SCADA system. NYPA provided ICCP interface as well as Common Information Model (CIM). The relevance of the DNSE+ application is that it provides state estimation of the power system based on hybrid set of data, consisting of both available PMU data and SCADA measurements. As this is a direct, non-iterative method of calculation of the system states, if does not suffer from convergence issues which is potential problem for conventional state estimators. Also, it can take any available PMU measurements, so it does not need to have a high percentage of PMU coverage needed in the case of Linear State Estimator. As the DNSE calculates synchrophasors of the system states (both phase and absolute value) as sub-second rate, this application can provide a basis for development of next generation of applications based both on SCADA and PMU data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parallel octree-based hexahedral mesh generation for eulerian to lagrangian conversion.

Computational simulation must often be performed on domains where materials are represented as scalar quantities or volume fractions at cell centers of an octree-based grid. Common examples include bio-medical, geotechnical or shock physics calculations where interface boundaries are represented only as discrete statistical approximations. In this work, we introduce new methods for generating Lagrangian computational meshes from Eulerian-based data. We focus specifically on shock physics problems that are relevant to ASC codes such as CTH and Alegra. New procedures for generating all-hexahedral finite element meshes from volume fraction data are introduced. A new primal-contouring approach is introduced for defining a geometric domain. New methods for refinement, node smoothing, resolving non-manifold conditions and defining geometry are also introduced as well as an extension of the algorithm to handle tetrahedral meshes. We also describe new scalable MPI-based implementations of these procedures. We describe a new software module, Sculptor, which has been developed for use as an embedded component of CTH. We also describe its interface and its use within the mesh generation code, CUBIT. Several examples are shown to illustrate the capabilities of Sculptor.

99 GENERAL AND MISCELLANEOUS↗

LOGAN: High-Performance X-Drop Pairwise Alignment on GPU (LOGAN) v1.0

Pairwise sequence alignment is one of the most computationally intensive kernels in genomic data analysis, accounting for more than 90% of the run time for key bioinformatics applications. This method is particularly expensive for third-generation sequences due to the high computational expense of analyzing these long read lengths (1Kb-1Mb). Given the quadratic overhead of exact pairwise algorithms such as Smith-Waterman, for long alignments, the community primarily relies on approximate algorithms that search only for high-quality alignments and stop early when one is not found. In this work, we present the first GPU optimization of the popular X-drop alignment algorithm, named LOGAN. Results show that our high-performance multi-GPU LOGAN implementation achieves up to 181.6 GCUPS and speed-ups up to 6.6x and 30.7x using 1 and 6 NVIDIA Tesla V100, respectively, over the state-of-the-art software running on two IBM Power9 processors using 168 threads, with equivalent accuracy. We also demonstrate a 2.3x LOGAN speed-up versus ksw2, a state-of-art vectorized algorithm for sequence alignment implemented in minimap2. To highlight the impact of our work on a real-world application, we couple the LOGAN aligner with a many-to-many long-read alignment software called BELLA, and demonstrate that our implementation improves the overall BELLA runtime by up to 10.6x. Finally, we adapt the Roofline model for our optimized kernel and demonstrate that our implementation is near-optimal on the NVIDIA Tesla V100s.

Guidi, Giulia↗

ATHENA, ARTEMIS, HEPHAESTUS: data analysis for X-ray absorption spectropscopy using IFEFFIT

A software package for the analysis of X-ray absorption spectroscopy (XAS) data is presented. This package is based on the IFEFFIT library of numerical and XAS algorithms and is written in the Perl programming language using the Perl/Tk graphics toolkit. The programs described here are: (i) ATHENA, a program for XAS data processing, (ii) ARTEMIS, a program for EXAFS data analysis using theoretical standards from FEFF and (iii) HEPHAESTUS, a collection of beamline utilities based on tables of atomic absorption data. These programs enable high-quality data analysis that is accessible to novices while still powerful enough to meet the demands of an expert practitioner. The programs run on all major computer platforms and are freely available under the terms of a free software license.

43 PARTICLE ACCELERATORS↗

PSpecteR: A User-Friendly and Interactive Application for Visualizing Top-Down and Bottom-Up Proteomics Data in R

Visual examination of mass spectrometry data is necessary to assess data quality and to facilitate data exploration. Graphics provide the means to evaluate spectral properties, test alternative peptide/protein sequence matches, prepare annotated spectra for publication, and fine-tune parameters during wet lab procedures. Visual inspection of MS data is hindered by proprietary proteomics visualization software designed for particular workflows and academic software that lack visualization tools. We built PSpecteR, an open-source and interactive R Shiny web application to address these issues, with support for several steps of proteomics data processing, including: reading various mass spectrometry files, running open-source database search tools, labelling spectra with fragmentation patterns, testing post-translational modifications, plotting where identified fragments map to reference sequences, and visualizing algorithmic output and metadata. All figures, tables, and spectra are exportable within one easy-to-use graphical user interface. Our current software provides a flexible and modern R framework to support fast implementation of additional features. The open source code is readily available (https://github.com/EMSL-Computing/PSpecteR), and a PSpecteR Docker container (https://hub.docker.com/r/emslcomputing) is available for easy local installation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Modeling and Analysis Methods for an On-line Enrichment Monitor

The International Atomic Energy Agency (IAEA) has developed an On-Line Enrichment Monitor (OLEM) as one possible component in a new generation of safeguards measures for uranium enrichment plants. The OLEM measures 235U emissions from the UF6 gas flowing through a unit header pipe using NaI(Tl) spectrometers, and corrects for gas density changes using pressure and temperature sensors in order to determine the enrichment of the gas as a function of time. In parallel with the OLEM instrument development, a Virtual OLEM (VOLEM) software tool has been developed that is capable of producing synthetic gamma-ray, pressure, and temperature data representative of a wide range of enrichment plant operating conditions. VOLEM complements instrument development activities and allows the study of OLEM for scenarios that will be difficult or impossible to evaluate empirically. Uses of VOLEM include: investigation of hardware design options; inter-comparison of candidate gamma-ray spectral analysis and enrichment estimation algorithms; uncertainty budget analysis and performance prediction for typical and atypical operational scenarios; and testing of the OLEM data acquisition, analysis and reporting software. This paper describes the technical foundations of VOLEM and illustrates how it can be used. An overview of the nominal instrument design and deployment scenario for OLEM is provided, with emphasis on the key online-assay measurement challenge: accurately determining the portion of the total 235U signal that comes from a background that includes solid uranium deposits on the piping walls. Monte Carlo modeling tools, data analysis algorithms and uncertainty quantification methods are described. VOLEM is then used to quantitatively explore the uncertainty budgets and predicted instrument performance for a plausible range of typical plant operating parameters, and one set of candidate analysis algorithms. Additionally, a series of VOLEM case studies illustrates how an online enrichment monitor might respond in scenarios expected to be atypical, for example weak pressure transients or significant changes in background levels.

Smith, Leon E.↗

Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum improvement of the NCC value by 100% and of the RMSD value by 81%. The corresponding maximum improvements for the registration-based approach were 20% and 40%. In phases with very rapid motion the registration-based algorithm obtained better image quality, while the image quality of the MAM algorithm was superior in phases with less motion. The image quality improvement of the MAM optimization was visually confirmed for the different clinical cases. Conclusions: The proposed method allows a software-based best-phase image quality improvement in coronary CT angiography. A short scan data interval at the target heart phase is sufficient, no additional scan data in other cardiac phases are required. The algorithm is therefore directly applicable to any standard cardiac CT acquisition protocol.

60 APPLIED LIFE SCIENCES↗

Companion Assisted Software Based Remote Attestation in SCADA Networks

Critical infrastructure such as power generation and water distribution systems have become a priority target in cyber warfare because of their recent computerization and introduction to the internet. As a result, Supervisory Control and Data Acquisition (SCADA) system security has become a hot topic in academic and industrial research. Among these topics, Remote Attestation is a security method intended to detect the presence of fileless malware in remote devices as they continue to operate. This allows for the detection of malware in the absence of long-term storage artifacts before symptoms of compromise begin to appear. In general, a trusted device (the verifier) makes a request for evidence of innocence from the untrusted device (the prover). In software-based schemes, the verifier can then measure the delay between its request and the prover’s response. If this delay is greater than the known computational time of the evidence gathering algorithm performed by the prover, then evidence may have been forged. Multi-hop networks often introduce too much network jitter to allow accurate measurement of prover response time, which limits the effectiveness of software based Remote Attestation in a real-world setting. In this work, we introduce a companion device that the verifier can trust to perform a subset of attestation, thereby removing any network jitter. This device is a Field Programmable Gate Array (FPGA) that is physically connected to the prover. We provide a communication protocol between the verifier, prover, and companion. To evaluate our scheme, we simulate it in a common SCADA network environment under normal and heavy traffic loads. Our simulations are performed in the discrete event network simulator NS-3, and we perform statistical analysis over our results to show that our scheme allows for tight timing constraints to be placed on the prover such that the verifier can more easily determine the validity of the evidence that it receives.

Johnson, William A.↗

Visualization and Data Analysis at the Exascale

The scope of our working group is scientific visualization and data analysis. Scientific visualization refers to the process of transforming scientific simulation and experimental data into images to facilitate visual understanding. Data analysis refers to the process of transforming data into an information-rich form via mathematical or computational algorithms to promote better understanding. We share scope on data management with the Storage group. Data management refers to the process of tracking, organizing and enhancing the use of scientific data. The purpose of our work is to enable scientific discovery and understanding. Visualization and data analysis has a broad scope as an integral part of scientific simulations and experiments, it is also a distinct separate service for scientific discovery and documentation purposes. Our scope includes an exascale software and hardware infrastructure that effectively supports visualization and data analysis.

ALGORITHMS↗

Multiyear Plan for Validation of EnergyPlus Multi-Zone HVAC System Modeling using ORNL's Flexible Research Platform

This document describes the Oak Ridge National Laboratory (ORNL) multiyear experimental plan for validation and uncertainty characterization of whole-building energy simulation for a multi-zone research facility using a traditional rooftop unit (RTU) as a baseline heating, ventilating, and air conditioning (HVAC) system. The project’s overarching objective is to increase the accuracy of energy simulation tools by enabling empirical validation of key inputs and algorithms. Doing so is required to inform the design of increasingly integrated building systems and to enable accountability for performance gaps between design and operation of a building. The project will produce documented data sets that can be used to validate key functionality in different energy simulation tools and to identify errors and inadequate assumptions in simulation engines so that developers can correct them. ASHRAE Standard 140, Method of Test for the Evaluation of Building Energy Analysis Computer Programs (ASHRAE 2004), currently consists primarily of tests to compare different simulation programs with one another. This project will generate sets of measured data to enable empirical validation, incorporate these test data sets in an extended version of Standard 140, and apply these tests to the Department of Energy’s (DOE) EnergyPlus software (EnergyPlus 2016) to initiate the correction of any significant deficiencies. The fitness-for-purpose of the key algorithms in EnergyPlus will be established and demonstrated, and vendors of other simulation programs will be able to demonstrate the validity of their products. The data set will be equally applicable to validation of other simulation engines as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of BWR OPRM plant data and detection algorithms with DSSPP

All U.S. BWRs are required to have licensed stability solutions that satisfy General Design Criteria (GDC) 10 and 12 of 10 CFR 50 Appendix A. Implemented solutions are either detect and suppress or preventive in nature. Detection and suppression of power oscillations is accomplished by specialized hardware and software such as the Oscillation Power Range Monitor (OPRM) utilized in Option III and Detect and Suppress Solution - Confirmation Density (DSS-CD) stability Long-Term Solutions (LTSs). The detection algorithms are designed to recognize a Thermal-Hydraulic Instability (THI) event and initiate control rod insertion before the power oscillations increase much higher above the noise level that may threaten the fuel integrity. Option III is the most widely used long-term stability solution in the US and has more than 200 reactor years of operational history. DSS-CD represents an evolutionary step from the stability LTS Option III and its licensed domain envelopes the Maximum Extended Load Line Limit Analysis Plus (MELLLA +) domain. In order to enhance the capability to investigate the sensitivity of key parameters of stability detection algorithms, GEH has developed a new engineering analysis code, namely DSSPP (Detect and Suppress Solution Post Processor), which is introduced in this paper. The DSSPP analysis tool represents a major advancement in the method for diagnosing the design of stability detection algorithms that enables designers to perform parametric studies of the key parameters relevant for THI events and to fine tune these system parameters such that a potential spurious scram might be avoided. Demonstrations of DSSPPs application are also presented in this paper utilizing actual plant THI data. A BWR/6 plant had a plant transient that included unplanned recirculation pump transfer from fast to slow speed resulting in about 100% to {approx}40% rated power decrease and about 99% to {approx}30% rated core flow decrease. As the feedwater temperature is reduced to equilibrium conditions, the power increased from about {approx}40% to about {approx}60% with little change inflow. A THI event developed and subsequently, an OPRM initiated scram occurred with Option III. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗