Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Lustre on Red Sky.

The goals of Lustre on Red Sky are: (1) provide home/projects/scratch Lustre file systems; (2) adhere to the Sun HPC stack; (3) implement software RAID on Sun provided JBODs; and (4) design for easy administration. Conclusions are: (1) software RAID includes additional risks and administration vs. hardware RAID solutions; (2) limited testing of hardware in these configurations make it ill-suited for rapid deployment in a production environment; and (3) Lustre has been a shining star on this machine, Red Sky users are pleased with its performance.

99 GENERAL AND MISCELLANEOUS↗

Implementation of a pressure correction term in the CTF sub-channel code

CTF [1] is a modernized and improved version of the legacy subchannel code, COBRA-TF [2], that is being jointly developed and maintained by Oak Ridge National Laboratory (ORNL) and North Carolina State University. The code was adopted by ORNL for use in the Consortium for Advanced Simulation of Light Water Reactors (CASL) in 2012 for aiding in addressing CASL challenge problems. Since that time, activities related to CTF have included implementing software quality assurance measures, implementing new features and models, performing validation and verification testing, establishing and supporting a CTF User Group, and developing the code for use in coupled applications [3, 4, 5]. CTF is applicable to single- and two-phase flows in light water reactor geometries at normal and accident operating conditions. The two-phase flow model consists of the six-equation two-phase flow model [6] augmented by equations for the droplet field and also includes appropriate source terms. This work focuses on the numerical stability of the six-equation two-phase flow model and is part of a recent eort to improve CTF capabilities for simulating flows in boiling nuclear reactors (BWRs). As it is of common knowledge among the thermodynamic community, the six-equation two-phase flow model is not strongly hyperbolic, meaning some of its eigenvalues are either not real or not distinct [7]. In a Cauchy sense and for an initial-value problem, strong hyperbolicity was found to be equivalent to well-posedness which ensures uniqueness of the solution in the space-time used. This concept is also of importance when designing high-order numerical methods and also when implementing boundary conditions that rely on real eigenvalues such as Riemann solvers. A tremendous amount of research is available in the literature on how to hyperbolize the six-equation two-phase flow model by adding ad hoc terms to the system of equations often referred to as virtual mass or interfacial pressure correction term. From a mathematical prospective, the main idea driving this approach is to add terms to the phasic momentum equation containing first-order partial derivatives of the unknowns to modify the Jacobian matrix and thus canceling the imaginary part of the eigenvalues.For this work it was chosen to implement a interfacial pressure correction (IPC) term on the same model as what was done for the CATHARE system code [8], that allows to recover a two-pressure formulation. In the following, the six-equation two-phase flow model is recalled along with the IPC term and its influence on the eigenvalues. Then, numerical results and convergence studies are presented for a water-faucet problem [9] at a pressure of 10 bar. Finally, conclusions and future work are addressed.

Delchini, Marco↗

Implementation of a Pressure Correction Term in the CTF Subchannel Code

CTF is a modernized and improved version of the legacy subchannel code COBRA-TF, being jointly developed and maintained by Oak Ridge National Laboratory (ORNL) and North Carolina State University. The code was adopted by ORNL for use in the Consortium for Advanced Simulation of Light Water Reactors (CASL) in 2012 to help address CASL challenge problems. Since that time, activities related to CTF have included implementing software quality assurance measures, implementing new features and models, performing validation and verification testing, establishing and supporting a CTF user group, and developing the code for use in coupled applications. CTF is applicable to single- and two-phase flows in light water reactor geometries at normal and accident operating conditions. The two-phase flow model consists of the six-equation two-phase flow model augmented by equations for the droplet field, and it also includes appropriate source terms. This work focuses on the numerical stability of the six-equation two-phase flow model and is part of a recent effort to improve CTF capabilities for simulating flows in boiling water reactors (BWRs). The six-equation two-phase flow model is not strongly hyperbolic, meaning that some of its eigenvalues are either not real or not distinct. In a Cauchy sense, and for an initial-value problem, strong hyperbolicity was found to be equivalent to well-posedness, which ensures the uniqueness of the solution in the space-time used. This concept is also of importance when designing high-order numerical methods and also when implementing boundary conditions that rely on real eigenvalues such as Riemann solvers. A tremendous amount of research is available in the literature on how to hyperbolize the six-equation two-phase flow model by adding ad hoc terms to the system of equations. Such terms are often referred to as virtual mass or interfacial pressure correction terms. From a mathematical perspective, this approach adds terms to the phasic momentum equation containing first-order partial derivatives of the unknowns to modify the Jacobian matrix, thus the imaginary part of the eigenvalues. For this work, an interfacial pressure correction (IPC) term on the same model as what was used for the CATHARE system code, is implemented in CTF. This allows for recovery of a two-pressure formulation. In the following, the six-equation two-phase flow model is recalled, along with the IPC term and its influence on the eigenvalues. Then, numerical results and convergence studies are presented for a water-faucet problem at a pressure of 10 bar. Finally, conclusions and future work are addressed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Risk Informed Timelines (RIT) v.1.0

Risk Informed Timelines (RIT) is a more modern and holistic method for understanding how access delay timelines are developed and utilized in physical security system evaluations. The software utilizes Bayesian methods to combine subject matter expert judgement and small performance test datasets in a consistent and defensible way. It allows a more holistic view of delay performance that provides distributions of task times and task success probabilities to account for tasks that, if failed, would result in failure of the attack. The RIT methodology is meant to enable security risk managers to begin the transition into more comprehensive delay timeline analysis. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-8294 O

Noel, ToddG.↗

Computer program for the sensitivity calculation of a CR-39 detector in a diffusion chamber for radon measurements

Computer software for calculation of the sensitivity of a CR-39 detector closed in a diffusion chamber to radon is described in this work. The software consists of two programs, both written in the standard Fortran 90 programming language. The physical background and a numerical example are given. Presented software is intended for numerous researches in radon measurement community. Previously published computer programs TRACK-TEST.F90 and TRACK-VISION.F90 [D. Nikezic and K. N. Yu, Comput. Phys. Commun. 174, 160 (2006); D. Nikezic and K. N. Yu, Comput. Phys. Commun. 178, 591 (2008)] are used here as subroutines to calculate the track parameters and to determine whether the track is visible or not, based on the incident angle, impact energy, etching conditions, gray level, and visibility criterion. The results obtained by the software, using five different V functions, were compared with the experimental data found in the literature. Application of two functions in this software reproduced experimental data very well, while other three gave lower sensitivity than experiment.

61 RADIATION PROTECTION AND DOSIMETRY↗

METABOLIC: high-throughput profiling of microbial genomes for functional traits, metabolism, biogeochemistry, and community-scale functional networks

Background Advances in microbiome science are being driven in large part due to our ability to study and infer microbial ecology from genomes reconstructed from mixed microbial communities using metagenomics and single-cell genomics. Such omics-based techniques allow us to read genomic blueprints of microorganisms, decipher their functional capacities and activities, and reconstruct their roles in biogeochemical processes. Currently available tools for analyses of genomic data can annotate and depict metabolic functions to some extent; however, no standardized approaches are currently available for the comprehensive characterization of metabolic predictions, metabolite exchanges, microbial interactions, and microbial contributions to biogeochemical cycling. Results We present METABOLIC (METabolic And BiogeOchemistry anaLyses In miCrobes), a scalable software to advance microbial ecology and biogeochemistry studies using genomes at the resolution of individual organisms and/or microbial communities. The genome-scale workflow includes annotation of microbial genomes, motif validation of biochemically validated conserved protein residues, metabolic pathway analyses, and calculation of contributions to individual biogeochemical transformations and cycles. The community-scale workflow supplements genome-scale analyses with determination of genome abundance in the microbiome, potential microbial metabolic handoffs and metabolite exchange, reconstruction of functional networks, and determination of microbial contributions to biogeochemical cycles. METABOLIC can take input genomes from isolates, metagenome-assembled genomes, or single-cell genomes. Results are presented in the form of tables for metabolism and a variety of visualizations including biogeochemical cycling potential, representation of sequential metabolic transformations, community-scale microbial functional networks using a newly defined metric “MW-score” (metabolic weight score), and metabolic Sankey diagrams. METABOLIC takes ~ 3 h with 40 CPU threads to process ~ 100 genomes and corresponding metagenomic reads within which the most compute-demanding part of hmmsearch takes ~ 45 min, while it takes ~ 5 h to complete hmmsearch for ~ 3600 genomes. Tests of accuracy, robustness, and consistency suggest METABOLIC provides better performance compared to other software and online servers. To highlight the utility and versatility of METABOLIC, we demonstrate its capabilities on diverse metagenomic datasets from the marine subsurface, terrestrial subsurface, meadow soil, deep sea, freshwater lakes, wastewater, and the human gut. Conclusion METABOLIC enables the consistent and reproducible study of microbial community ecology and biogeochemistry using a foundation of genome-informed microbial metabolism, and will advance the integration of uncultivated organisms into metabolic and biogeochemical models. METABOLIC is written in Perl and R and is freely available under GPLv3 at https://github.com/AnantharamanLab/METABOLIC.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Miniature DC electromagnetic pumps of molten lead and sodium to support development of Gen-IV nuclear reactors

This work developed designs of submerged, dual-regions, miniature DC-EM pumps for circulating molten lead and liquid sodium at ≤500 °C without active cooling for use in ex-pile and in-pile test loops to support of materials and fuel developments for Gen-IV sodium and molten lead fast nuclear reactor. These pumps with two pumping regions are 57 mm, 66.8 mm, 95.4 mm, and 133.5 mm in diameter and have two Alnico 5 permanent magnets with Hiperco-50 pole pieces for focusing the magnetic field lines in the flow duct. The Equivalent Circuit Model (ECM) linked to the Finite Element Method Magnetics (FEMM) software in MATLAB platform calculated the pumps characteristics for a wide range of parameters. Also determined are the pumps dimensions for the highest cumulative pumping power and peak efficiency. These dimensions are the height, width, and length of the flow duct, the thickness of the Alnico magnets, the length of current electrodes, and the separation distance between the two pumping regions. For molten lead, the pumping power increases from 368 W to 728 W, and the peak efficiency from 14.7% to 31.6% with increased pump diameter from 57 mm to 133.5 mm. In conclusion, for liquid sodium, both the pumping power and peak efficiency are higher, increasing from 392 W to 767 W and from 44.3 to 51.2%, respectively, with increased pump diameter from 57 mm to 133.5 mm.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a signal conditioner for the Fermilab Magnet Test Facility

This thesis describes the design of a remotely-programmable signal conditioner for the harmonic measurement of accelerator magnets. A 10-channel signal conditioning circuit featuring bucking capabilities was designed from scratch and implemented to the level of the printed circuit board layout. Other system components were chosen from those available on the market. Software design was started with the definition of routine procedures. This thesis is part of an upgrade project for replacing obsolescent automated test equipment belonging to the Fermilab Magnet Test Facility. The design started with a given set of requirements. Using a top-down approach, all the circuits were designed and their expected performances were theoretically predicted and simulated. A limited prototyping phase followed. The printed circuit boards were laid out and routed using a CAD software and focusing the design on maximum electromagnetic interference immunity. An embedded board was selected for controlling and interfacing the signal conditioning circuitry with the instrumentation network. Basic low level routines for hardware access were defined. This work covered the entire design process of the signal conditioner, resulting in a project ready for manufacturing. The expected performances are in line with the requirements and, in the cases where this was not possible, approval of trade-offs was sought and received from the end users. Part I deals with the global structure of the signal conditioner and the subdivision in functional macro-blocks. Part II treats the hardware design phase in detail, covering the analog and digital circuits, the printed circuit layouts, the embedded controller and the power supply selection. Part III deals with the basic hardware-related routines to be implemented in the final software.

43 PARTICLE ACCELERATORS↗

Development of New Antifoam for High Level Waste Processing in DWPF

During processing in the Defense Waste Processing Facility (DWPF), the evaporation of sludge leads to large amounts of foaming. This foaming can cause a foam-over, which contaminates other parts of the facility, most importantly the condensate. Currently, the antifoam being used is not sufficient at more extreme pH values and relatively high concentrations are required to minimize foaming. This means that a foam-over is more likely in parts of the process where the pH moves away from the neutral point and antifoam is needed in large quantities to prevent such occurrences. Adding this antifoam can also double processing time. The current antifoam also degrades into flammable byproducts, which creates a hazard in the processing. There are two main ideas proposed in order to solve the problems with the current antifoam: A new antifoam; A mechanical solution (sprays, agitator, etc). The focus of this summer was to develop a new antifoam that works across a broader range of pH values, can be added in lower concentrations, and does not degrade into flammable byproducts. This solution was pursued by obtaining different superspreaders and antifoams from companies across the country in order to perform a series of tests on them; these tests include superspreader testing, Foamscan testing, boiling testing, and Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) process testing. To begin testing, four different superspreaders were tested on their ability to spread. The four superspreaders include: Y-17112, Y-17309, Antifoam 747 (the old antifoam), and Silwet L77 (the main component in Antifoam 747). These superspreaders were tested across a range of pH values and concentrations from 100 ppm to 5000 ppm. After completion of the tests, the results indicated that Y-17112 spread across a wider pH range than the others, even at lower concentrations. This is ideal for developing a new antifoam, as the pH throughout processing in DWPF varies and the lower the necessary concentration, the less antifoam that must be added per cycle. In order to test whether or not the superspreaders work as an antifoam, they have to be tested on real foam. In order to test this, a foamy simulant similar to the foaminess of the sludge in DWPF needed to be developed. This required testing many different sludges and designing our own simulant with different concentrations of insoluble solids. Eventually, a simulant similar enough to what is seen in DWPF was identified. Each superspreader will be tested on the simulant at different pH values and at different concentrations. The simulant will be allowed to foam and small amounts of the superspreader will be added while the Foamscan software tracks the height of the foam column; this allows us to know if the superspreader decreased the foam or not. Next, boiling testing in the Foamscan will be completed. This is testing identical to the Foamscan testing at room temperature, only at boiling conditions similar to DWPF. After boiling testing, the superspreader that is deemed most successful will be tested in a real, scaled-down SRAT/SME cycle. This will ensure it works with all the real chemicals that are added in DWPF and that it will remain successful in all the conditions that it may face. After the SRAT/SME testing, a decision will be made on whether or not the superspreader is successful and it may or may not be chosen as the new antifoam for DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting Instability and the Effect of Wind Loading on Single-Axis Trackers

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. In our ongoing DuraMAT project, we are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software, highlighting recent user-interface and algorithm developments, before presenting the latest outcomes from our ongoing validation campaign in which we analyze and compare with experimental data obtained from a DuraMAT 1 project. From there, we will present simulated results from a larger, multi-row array and highlight relationships between varying tracker angles and stability as measured by different experimentally validated metrics.

fluid structure interaction↗

A Simulation and Optimization Framework for Managing Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability as measured by both acceleration and deformation, focusing on the stability differences between positive and negative tilt angles.

fluid structure interaction↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-AB-204-04: Connectathons and Testing

You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standards like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Sampling Inlets for Continuous Air Monitors in Calm Air Conditions

The Canberra NetCAM (networked continuous air monitor) can be operated with a radial inlet attachment from the manufacturer. Sampled aerosol can be transported through large diameter tubing from a desired location to the NetCAM sampler. In this assessment, the effect of the addition of the radial inlet was investigated. Also, a sampling system consisting of a vertical sample tube and a 90-degree elbow (to the horizontal plane) was evaluated by empirical calculations with the DEPO software. Generalized aspiration ratio calculations were done with the empirical model from Vincent. Three different sample probe types were also experimentally tested. In summary: (1) For typical room air conditions, the addition of the Canberra inline adapter to the NetCAM has no discernible effect on system performance. This was determined by literature search with a previously published study. (2) The DEPO software (US NRC / Texas A&M University) was used to show the effect of adding a 2-meter high vertical tube and a ninety-degree tube bend to a sampling inlet. In this example, there was a total penetration of 97.7% of 10-micron diameter aerosol particles for an air flowrate of 2.0 ACFM (actual cubic feet per minute). (3) Calculations of nozzle aspiration ratio (for general, non-specific situations) were performed using the Vincent empirical model. For example, in typical room air, where the average velocity is less than 0.5 m/sec, an aerosol inlet probe has a calculated aspiration ratio (or penetration efficiency) value between 98 and 100%, depending on the angle of the probe inlet compared to the direction of the incoming air velocity vector. A table of nozzle aspiration ratios was generated for a range of different room air velocities and probe inlet angles. (4) Three different candidate probe geometries were tested, (A) a probe with a vertical entry and vertical transport tube, (B) a probe with a horizontal entry and vertical transport tube, and (C) a ‘widemouth’ probe with a vertical entry and vertical transport tube. The experimentally determined values were 98%, 102%, and 100%, respectively, for the aerosol penetration into these inlets. In conclusion, the addition of a complete sampling system with probe inlet, a short length of sampling lines and the radial inlet would still be able to deliver about 95% of the sampled aerosol from the sampling location to the Canberra NetCAM.

61 RADIATION PROTECTION AND DOSIMETRY↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Continuous Test and Transition Infrastructure for Quantum Networking for Science Complex

We propose a network architecture with a separate quantum dataplane and a conventional control plane: (a) Quantum Data Plane: The Quantum Data plane consists of links of dark fibers connecting quantum switches and repeaters, which in turn, connect to quantum computers, memory and sensors. Since the current reach is limited to local areas, it will begin as a collection of site networks at laboratories, (b) Conventional Control Plane: The Control plane provides management access to quantum devices for configuration and provisioning via control nodes with firewall and encryption capabilities. Continuous Test and Transition Infrastructure: We propose an infrastructure with a control plane connecting multiple sites via encrypted tunnels over conventional networks consisting of the following: (a) Site Quantum Networks: Individual site networks supported by their fiber plants connect laboratories that house and connect to their quantum devices for testing and interoperability.(b) Site Control Planes: Sites are connected over individual control planes with control hosts with Software Defined Networking capabilities, which can be peered with other networks via ESnet.(c) Progressive Expansion: Initially, sites will develop individual data planes with their specific quantum devices and fiber connections, and mechanisms to interface with conventional networks. They progressively expand and interconnect, under a wide-area ecosystem of peered control planes for device testing, interoperability development and roll off into production environments.

Rao, Nageswara S.↗

US Veteran Gets a Facelift

Idaho National Laboratory's Advanced Test Reactor (ATR) has received replacement instrumentation and control systems - the process distributed control system (DCS) and the console display system (CDS), which included a replacement annunciator subsystem. The new systems offer the latest software and technology advancements, ensuring the availability of the reactor for future energy research. ATR, a pressurized, light water moderated 250 MW materials test reactor, became operational in 1965. In the early 1990s, after nearly thirty years of analogue/pneumatic controls, the laboratory upgraded ATR to digital-based instrumentation and control systems. By 2007, the equipment and technology used in these digital systems were reaching the end of their lifecycle. The systems component failure rates were on a rise, while vendor support and parts availability were declining. With current projections and plans for operating ATR into 2040, modernization of the reactor's infrastructure is necessary to maintain reliability and efficiency. As a result, the Idaho National Laboratory and the U.S. Department of Energy (DOE) invested more than $13 million in a four-year project to replace ATR's instrumentation and control systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗