Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Uncertainty Quantification of Calculated Temperatures for the AGR 5/6/7 Experiment

This report documents the quantification of uncertainty of the calculated temperature data for the Advanced Gas Reactor (AGR) 5/6/7 fuel irradiation experiment conducted in the Advanced Test Reactor at Idaho National Laboratory in support of the Advanced Reactor Technologies? research and development program. Recognizing uncertainties inherent in physics and thermal simulations of the AGR 5/6/7 capsules, the results of the numerical simulations are used in combination with statistical analysis methods to improve qualification of measured data. The calculated fuel temperatures for AGR tests are also used for validation of the fission product transport and fuel performance simulation models. These crucial roles of the calculated fuel temperatures in ensuring achievement of the AGR experimental program objectives require accurate determination of the model temperature uncertainties. This report covers temperature uncertainty results for each of the five AGR 5/6/7 capsules. To quantify the uncertainty of calculated temperatures determined using the ABAQUS finite element heat transfer code, this study identifies and analyzes model parameters of potential importance to the calculated temperatures of fuel compacts and thermocouples. The selection of input parameters for uncertainty quantification is based on the ranking of their influences upon temperature predictions. Thus, selected input parameters include those with high sensitivity and those with the largest uncertainty. Propagation of model parameter uncertainty and sensitivity is then used to quantify the overall uncertainty of calculated temperatures. Measurement uncertainty, analysis of modeling assumptions, and expert judgment are used as the basis to quantify the uncertainty range for selected input parameters. The input uncertainties are dynamic, accounting for the effect of unplanned events and changes in thermal properties of capsule components over extended exposure to high temperatures and fast neutron irradiation. The sensitivity analysis performed in this work went beyond the traditional local sensitivity. Using experimental design, analysis of pairwise interactions of model parameters was performed to establish sufficiency of the time dependent first order (linear) expansion terms in constructing the temperature response surface. To achieve completeness, uncertainty propagation made use of pairwise noise correlations of model parameters. Furthermore, using an interpolation scheme over the input parameter domain, the analysis obtains time dependent sensitivity over the test campaign duration. This allows computation of uncertainty for the calculated fuel temperatures and the calculated graphite temperatures at thermocouple locations during the entire irradiation period.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of the Preliminary Optical ICHMI Design Study: A Preliminary Engineering Design Study for a Standpipe Viewport

This summary report examines an in-vessel optical access concept intended to support standoff optical instrumentation, control and human-machine interface (ICHMI) systems for future advanced small modular reactor (AdvSMR) applications. Optical-based measurement and sensing systems for AdvSMR applications have several key benefits over traditional instrumentation and control systems used to monitor reactor process parameters, such as temperature, flow rate, pressure, and coolant chemistry (Anheier et al. 2013). Direct and continuous visualization of the in-vessel components can be maintained using external cameras. Many optical sensing techniques can be performed remotely using open optical beam path configurations. Not only are in-vessel cables eliminated by these configurations, but also sensitive optical monitoring components (e.g., electronics, lasers, detectors, and cameras) can be placed outside the reactor vessel in the instrument vault, containment building, or other locations where temperatures and radiation levels are much lower. However, the extreme AdvSMR environment present challenges for optical access designs and optical materials. Optical access is not provided in any commercial nuclear power plant or featured in any reactor design, although successful implementation of optical access has been demonstrated in test reactors (Arkani and Gharib 2009). This report outlines the key engineering considerations for an AdvSMR optical access concept. Strict American Society of Mechanical Engineers (ASME) construction codes must be followed for any U.S. nuclear facility component (ASME 2013); however, the scope of this study is to evaluate the preliminary engineering issues for this concept, rather than developing a nuclear-qualified design. In addition, this study does not consider accident design requirements. In-vessel optical access using a standpipe viewport concept serves as a test case to explore the engineering challenges and performance requirements for sodium fast reactor (SFR) and high-temperature gas reactor (HTGR) AdvSMR applications. The expected environmental conditions for deployment are reviewed for both AdvSMR designs. Optical and mechanical materials that maximize component lifetime are evaluated for the standpipe viewport design under these conditions. Optical components and opto-mechanical designs that provide robust optical-to-metal seals and stress-free optical component mounting are identified, and then key performance specifications are developed for a sapphire optical viewport concept. Design strategies are examined that protect the internal optical surfaces from liquid-coolant condensation and impurity deposits. Finally, a conceptual standpipe viewport design that is suggestive of how this concept could be assembled using standard nuclear-qualified pipe components, is presented.

42 ENGINEERING↗

Coupled Thermal-Hydraulic and Fuel Performance Simulations of the TWIST LOCA Commissioning Test Series in TREAT

As the nuclear industry is looking to increase light water reactor (LWR) burnup limits, Idaho National Laboratory has developed an experiment vehicle for the Transient Reactor Test Facility (TREAT) to support high burnup fuel safety testing. One of the main purposes of this vehicle, known as the Transient Water Irradiation System for TREAT (TWIST), is to perform in-pile loss-of-coolant accident (LOCA) experiments on high burnup LWR fuel to investigate phenomena termed fuel fragmentation, relocation, and dispersal (FFRD). Prior to performing experiments on high burnup fuel specimens, a commissioning test series will be performed. The main purpose of the Loss-of-Coolant-Commissioning (LOC-C) test series is to qualify the TWIST device and validate the power coupling between TREAT and the TWIST fuel rod as well as validation of the thermal-hydraulic and fuel performance simulation predictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compaction in optical fibres and fibre Bragg gratings under nuclear reactor high neutron and gamma fluence

In the framework of the development by CEA and SCK.CEN of a Fabry Perot Sensor (FPS) able to measure dimensional changes in Material Testing Reactor (MTR), the first goal of the SAKE 1 (Smirnof extention - Additional Key-tests on Elongation of glass fibres) irradiation was to measure the linear compaction of single mode fibres under high fast neutron fluence. Indeed, the compaction of the fibre which forms one side of the Fabry Perot cavity, may in particular cause a noticeable measurement error. An accurate quantification of this effect is then required to predict the radiation-induced drift and optimize the sensor design. To achieve this, an innovative approach was used. Approximately seventy uncoated fibre tips (length: 30 to 50 mm) have been prepared from several different fibre samples and were installed in the SCK.CEN BR2 reactor (Mol Belgium). After 22 days of irradiation a total fast (E > 1 MeV) fluence of 3 to 5x10{sup 19} n{sub fast}/cm{sup 2}, depending on the sample location, was accumulated. The temperature during irradiation was 291 deg. C, which is not far from the condition of the intended FPS use. A precise measurement of each fibre tip length was made before the irradiation and compared to the post irradiation measurement highlighting a decrease of the fibres' length corresponding to about 0.25% of linear compaction. The amplitude of the changes is independent of the capsule, which could mean that the compaction effect saturates even at the lowest considered fluence. In the prospect of performing distributed temperature measurement in MTR, several fibre Bragg gratings written using a femtosecond laser have been also irradiated. All the gratings were written in radiation hardened fibres, and underwent an additional treatment with a procedure enhancing their resistance to ionizing radiations. A special mounting made it possible to test the reflection and the transmission of the gratings on fibre samples cut down to 30 to 50 mm. The comparison of measurements made before and after the irradiation, at the same temperature, allowed us to measure the loss in reflectivity as well as the Bragg wavelength drift. The results are quite promising for some of the investigated gratings. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-Destructive Postirradiation Examination of the AFC-4C Capsule/Rodlet 5 Experiment

The AFC-4C irradiation test was irradiated at the Idaho National Laboratory Advanced Test Reactor to investigate several different fast reactor fuels that could be used to facilitate ultra-high burnup applications in sodium fast reactors. Several different alloys, fuel geometries, bonding materials, and coating/barrier were tested in ferritic-martensitic HT-9 cladding. The AFC-4C capsule 5 was removed from the reactor at around 8.7 at %HM burnup to begin postirradiation examination. This report presents and discusses the non-destructive PIE results of the AFC-4C-capsule / rodlet 5, a U-10Zr solid fuel, sodium bonded with HT9 with internal Cr-coating, and its performance is evaluated against the historical fuel performance of previously irradiated fuel from literature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of the TREAT Conversion Conceptual Design and Fuel Qualification Plan

The U.S. Department of Energy (DOE) is preparing to re establish the capability to conduct transient testing of nuclear fuels at the Idaho National Laboratory (INL) Transient Reactor Test (TREAT) facility. The original TREAT core went critical in February 1959 and operated for more than 6,000 reactor startups before plant operations were suspended in 1994. DOE is now planning to restart the reactor using the plant's original high-enriched uranium (HEU) fuel. At the same time, the National Nuclear Security Administration (NNSA) Office of Material Management and Minimization Reactor Conversion Program is supporting analyses and fuel fabrication studies that will allow for reactor conversion to low-enriched uranium (LEU) fuel (i.e., fuel with less than 20% by weight 235U content) after plant restart. The TREAT Conversion Program's objectives are to perform the design work necessary to generate an LEU replacement core, to restore the capability to fabricate TREAT fuel element assemblies, and to implement the physical and operational changes required to convert the TREAT facility to use LEU fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Further Development of Crack Growth Detection Techniques for US Test and Research Reactors

One of the key issues facing Light Water Reactors (LWRs) in extending lifetimes beyond 60 years is characterizing the combined effect of irradiation and water chemistry on material degradation and failure. Irradiation Assisted Stress Corrosion Cracking (IASCC), in which a crack propagates in a susceptible material under stress in an aggressive environment, is a mechanism of particular concern. Full understanding of IASCC depends on real time crack growth data acquired under relevant irradiation conditions. Techniques to measure crack growth in actively loaded samples under irradiation have been developed outside the US - at the Halden Boiling Water Reactor, for example. Several types of IASCC tests have also been deployed at the MITR, including passively loaded crack growth measurements and actively loaded slow strain rate tests. However, there is not currently a facility available in the US to measure crack growth on actively loaded, pre-cracked specimens in LWR irradiation environments. A joint program between the Idaho National Laboratory (INL) and the Massachusetts Institute of Technology (MIT) Nuclear Reactor Laboratory (NRL) is currently underway to develop and demonstrate such a capability for US test and research reactors. Based on the Halden design, the samples will be loaded using miniature high pressure bellows and a compact loading mechanism, with crack length measured in real time using the switched Direct Current Potential Drop (DCPD) method. The basic design and initial mechanical testing of the load system and implementation of the DCPD method have been previously reported. This paper presents the results of initial autoclave testing at INL and the adaptation of the design for use in the high pressure, high temperature water loop at the MITR 6 MW research reactor, where an initial demonstration is planned in mid-2015. Materials considerations for the high pressure bellows are addressed. Design modifications to the loading mechanism required by the size constraints of the MITR water loop are described. The safety case for operation of the high pressure gas-driven bellows mechanism is also presented. Key issues are the design and response of systems to limit gas flow in the event of a high pressure gas leak in the in-core autoclave. Integrity of the autoclave must be maintained and reactivity effects due to voiding of the loop coolant must be shown to be within the reactor technical specifications. The technical development of the crack growth monitor for application in the INL Advanced Test Reactor or the MITR can act as a template for adaptation of this technology in other reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In-Pile Fuel Rod Deformation Measurements Using Miniaturized LVDT Technology

Different types of materials are being considered for fuel, cladding, and structures in existing and advanced nuclear reactors. These materials can undergo significant dimensional changes during irradiation. Currently in the US, such changes are measured with the ‘cook and look’ method (i.e. repeatedly irradiating a specimen for a specified period of time, and then removing it from the reactor for evaluation) – which leads to costly and time consuming experiments. In addition, such techniques provide limited data, and handling may disturb the phenomena of interest. Therefore, in-pile detection of geometric changes is needed to understand real-time behavior during irradiation testing of fuels and materials in high flux US Material and Test Reactors (MTRs). The developmental results of an advanced Linear Variable Differential Transformer (LVDT)-based test rig capable of detecting real-time changes in diameter or length of fuel rods or other material samples during irradiation in US MTRs are presented. The LVDT is being developed at the Idaho National Laboratory (INL), and will provide experimenters with the capability to measure dimensional changes associated with fuel and clad swelling, pellet-clad interaction, and crud buildup. The LVDT design utilizes the MTR’s loop pressure to drive the test specimen at a constant rate. This leads to a simplified construction which only requires three pressure boundary penetrations. Further, the LVDT pressure boundary is a leak tight hydraulic ram capable of actuating under low differential pressure (e.g. 1 psid), and is able to survive the high irradiation tests at Pressurized Water Reactor (PWR) conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancement of Functional Expansion Tallies Capabilities in Serpent 2

The need for accident tolerant fuels (ATFs) became self-evident after the series of unfortunate nuclear events at Fukushima Daiichi in 2011. Restarting the Transient Reactor Test Facility (TREAT) at INL is one component in this concerted effort to establish the ATF development and testing program under the United States Department of Energy. Prior to the closure of TREAT in 1994, each experiment required multiple low-power calibration tests before and after each run. Since then, computing advancements have set computer-based modeling and simulation (M and S) as the preferred calibration method. The anticipated savings are both temporal and monetary. MAMMOTH, a collection of M and S tools built from the finite element-based MOOSE Framework, has been established to support the designed experiments intended for TREAT. This collection of tools includes: 1) Rattlesnake, a striking diffusion-based neutronics code, 2) BISON, an advanced materials and fuels performance code, and 3) RELAP-7, a powerful thermal-hydraulics solver. Each is capable of independently performing its function accurately and effectively; unified, they create a powerful multiphysics reactor core M and S application. One unfortunate weakness in this configuration lies in the unique geometry and design of TREAT's core. Although simple to model, this poses a challenge to the diffusion solver in Rattlesnake. One alternative is to replace Rattlesnake with Serpent, a fully-fledged Monte Carlo (MC) neutronics code. Coincidentally, Rattlesnake calculations are frequently validated against Serpent simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radial Deconsolidation and Leach-Burn-Leach of AGR-3/4 Compact 1-4 and 10-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined in one test train for irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011 and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both focused on obtaining data on fission product transport to support the improvement of modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and postirradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite (Petti et al. 2005). These two goals were combined in the AGR-3/4 irradiation, which consisted of twelve independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. There were two capsule types: a standard capsule and a “fuel body”, in which the outer graphite ring included a floor and cap that fully enclosed the fuel (Stempien et al. 2018a). The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to provide data on fission product transport and release from matrix and graphite at accident temperatures (Demkowicz 2017).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Fission Accelerated Steady State Test (FAST) -- A Revised Capsule Design for the Accelerated Testing of Advanced Reactor Fuels

In an effort to improve the development and testing of novel nuclear fuels, a detailed evaluation on reducing the size of fuel specimens for irradiation has been performed. Theoretically speaking, reducing the fuels diameter and incorporating an inner capsule while maintaining the original outside diameter of the experiment significantly reduces the experiment’s sensitivity to fabrication tolerances and drastically reduces the time necessary to reach a desired fuel burnup; both of which improve the cost and schedule associated with the fuel testing. Simulations of this reduced diameter, double encapsulated concept have been performed using Abaqus, MCNP, and ORIGEN. The results of the Abaqus simulations are beyond the scope of this summary and will not be presented herein. For results of these Abaqus simulations, see Beausoleil [2]. The models were tested using various parameters and design deviations which were then compared to the original Advanced Fuels Campaign (AFC) designs. The results of these simulations confirmed that the introduction of a second capsule coupled to a reduction in the fuel pin diameter significantly reduces the experiment’s sensitivity to fabrication tolerances and reduces the time to reach a desired burnup by nearly an order of magnitude. The original AFC design requires approximately 11.7 years to reach 30 Atom % Heavy Metal (at% HM) burnup. A burnup of 30 at% HM can be reached in approximately 2.5 to 3.5 years (irradiation position dependent) with a fuel diameter ½ (~0.097 in. diameter) that of the original AFC design. An added benefit to the fuel pin diameter reduction is that more specimens can be irradiated in any given cycle. Essentially, significantly more specimens can be tested and incur more burnup over a given operating cycle relative to the AFC design. This allows the development of a large test matrix of samples with rapid throughput in ATR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NucMesh: nuclear reactor geometry creation and mesh generation module in NEMoSys

NucMesh is a parameterized geometry and mesh generator for nuclear reactors developed within the Nuclear Energy Modeling System NEMoSys at Illinois Rocstar. NEMoSys is a platform developed for mesh generation, adaptive refinement, and solution verification. NucMesh is implemented to be generalized and extensible with a robust computer aided design engine and multiple mesh generation algorithms for unstructured triangular, quad-dominant, and structured quadrilateral meshing. In this paper, we present the geometric and meshing features of NucMesh. Geometrically objects are constructed bottom-to-top and overlaps are addressed automatically. A sophisticated object tracking algorithm prevents data from being lost for segmented objects. We discuss the primitive objects of circle and polygons that constitute the module and show how they are used with example inputs. Arrays of primitives and arrays of arrays are utilized to build large assemblies of objects. The concept of saved objects is discussed to demonstrate how repetitive objects can be reused easily and augmented in place. Three dimensional meshes can be obtained through mesh extrusion where all materials and side sets are extended to three dimensions. We show that side sets can be defined nearly anywhere within the geometry and can then be applied to the mesh. Finally, example reactor meshes are demonstrated for the Idaho National Laboratory Advanced Test Reactor and Los Alamos National Lab Empire reactor, both of which use control drums that NucMesh handles easily. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantity of 135I Released from the AGR 5/6/7 Experiment

A series of four Advanced Reactor Technologies (ART) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2020, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each Advanced Gas Reactor (AGR) experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135mXe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135I. About 2.5 hours after irradiation (ten 15.3 minute 135mXe half lives) the directly produced 135mXe has decayed and only the longer lived 135I remains as a source. Decay systematics dictate that 135mXe will be in secular equilibrium with its 135I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135I released from the fuel particles by measurement of the 135mXe at the FPM following reactor shutdown. In this paper, the 135I released will be reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Power transient analyses of experimental in-reflector devices during safety shutdown in Jules Horowitz Reactor (JHR)

The Jules Horowitz Reactor (JHR) is designed to be a 100 MW material testing reactor (MTR) and it is expected to become the reference facility in the framework of European nuclear research activity. As the core neutron spectrum is quite fast, several experimental devices concerning fuel studies have been conceived to be placed in the reflector in order to exploit a proper thermal neutron flux irradiation. Since the core power is relatively high, the neutronic coupling between the reactor core and the reflector devices has to be taken into account for different rod insertions. In fact the thermal power produced within the fuel samples is considerable. Heat removal during shutdown is a main topic in nuclear safety and it is worth to analyse thermal power transients in fuel samples as well. Here a thermal hydraulic model for JHR core is proposed aiming at a simple and representative description as far as reactivity feedbacks are concerned. Then it is coupled with a neutronic pointwise kinetics analysis by means of the DULCINEE code to compute core power transient calculations. Moreover, some reflector-core coupling evaluations are performed through Monte Carlo method using the TRIPOLI 4.7 code. The JHR equilibrium cycle is considered with respect to four fuel compositions namely Beginning of Cycle (BOC), Xenon Saturation Point (XSP), Middle of Cycle (MOC) and End of Cycle (EOC). Then thermal power transients in the experimental reflector devices are evaluated during safety shutdowns and they are verified for all these cycle steps. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Automatic Reactor Control System (ARCS) Upgrade, version 2.0 for TREAT

The Transient REActor Test Facility (TREAT) recently underwent an upgraded to the Automatic Reactor Control System (ARCS). The purpose of the upgrade was to institute a new software architecture that is better suited for the programming environment, patched software bugs and applied two new segments for reactor control. This paper will focus on the new segments for reactor control. The two new control segments added to ARCS are called Generic Power and Generic Rods. The original version of ARCS provided only two power related functions, namely periods and ramps, that had to be spliced together to generate any power shape. The Generic Power segment allows the user to input data points to define the function and then the algorithm does its best to create the desired shape. The original ARCS program utilized two direct rod commands (i.e. open loop control), these were a rod stop and clip. A Generic Rod segment extends the ability of the computer to directly command any rod position. The functionality of these new segments was proven during the TREAT outage in 2024.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Radial Deconsolidation and Leach-Burn-Leach of AGR-3/4 Compacts 8-4 and 7-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined into one test train for irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011, and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both to be focused on obtaining fission product transport data to support improvements in modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and postirradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite (Petti et al. 2005). These goals were combined in the AGR-3/4 irradiation experiment, which consisted of twelve independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. There were two capsule types: a standard capsule and a fuel body, in which the outer graphite ring included a floor and cap to fully enclose the fuel (Stempien et al. 2018a). The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to obtain data on fission product transport and release from matrix and graphite at accident temperatures (Demkowicz 2017).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Production of Sn-117m in the BR2 and HFIR Research Reactors

The BR2 reactor is a 100 MW{sub th} high-flux 'materials testing reactor', which produces a wide range of radioisotopes for various applications in nuclear medicine and industry. Tin-117m ({sup 117m}Sn), a promising radionuclide for therapeutic applications, and its production have been validated in the BR2 reactor. In contrast to therapeutic beta emitters, {sup 117m}Sn decays via isomeric transition with the emission of monoenergetic conversion electrons which are effective for metastatic bone pain palliation and radiosynovectomy with lesser damage to the bone marrow and the healthy tissues. Furthermore, the emitted gamma photons are ideal for imaging and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Printed Strain Gauges for High Temperature Applications (>300°C)

The real-time understanding of strain and deformation of materials provides prognostic health monitoring of components of current operational reactors and valuable data that shortens the timeline for the development of new nuclear-relevant materials in test reactor experiments. This report discusses the current development and testing of additively manufactured strain gauges. This has potential to improve the sensor design and manufacturing techniques to meet the requirements of the current and advanced nuclear reactors (i.e., in terms of environment conditions, sample geometry, and materials compatibility). The developmental additively manufactured strain gauges are exposed to separate effects testing (i.e., mechanical strain, high temperature) to determine environmental factors that affect the strain gauge. In addition, sensor qualification methodologies are further developed for determining the reliability and robustness at the interface of the AM strain gauge materials.

36 MATERIALS SCIENCE↗