Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

A preliminary analysis of the data from experiment 77-13 and final report on glass fining experiments in zero gravity

Thermal fining, thermal migration of bubbles under reduced gravity conditions, and data to verify current theoretical models of bubble location and temperatures as a function of time are discussed. A sample, sodium borate glass, was tested during 5 to 6 minutes of zero gravity during rocket flight. The test cell contained a heater strip; thermocouples were in the sample. At present quantitative data are insufficient to confirm results of theoretical calculations.

Wilcox, W. R.↗

Description and discussion of the NRL TGDCC

The NRL thermal gradient diffusion cloud chamber (TGDCC) consists of two plates 7.5 cm in diameter separated by 1.25 cm and covered with saturated filter paper. The cylindrical wall separating the plates is glass. The top plate is at room temperature and the bottom plate is cooled with a thermoelectric cooler. The temperature difference is measured with several sets of thermocouples. The CCN concentration was determined from the video recording. This procedure of averaging the maximum count obtained on several successive recordings at the same supersaturation results in concentrations which are somewhat higher than concentrations calculated from an average across the plateau.

Hoppel, W. A.↗

Multi-channel temperature measurement amplification system

A number of differential outputs of thermocouples are sequentially amplified by a common amplifier. The amplified outputs are compared with a reference temperature signal in an offset correction amplifier, and a particularly poled output signal is provided when a differential output is of a discrete level compared with a reference temperature signal.

Currie, J. R.↗

Heat generation rates in lithium thionyl chloride cells

An empirical equation that is useful for good first approximation in thermal modeling is presented. Indications and measurements of electrochemical heat effects were investigated. The particular cells of interest are of the D size, with spiral wound configuration and were instrumented with a thermocouple. It is found that cathode limited cells can explode on reversal at moderate temperatures.

Frank, H.↗

Thin film temperature sensors, phase 3

A thin film thermocouple system installation suitable for engine test evaluation was designed, and an engine test plan was prepared. Film adherence, durability, accuracy, and drift characteristics were improved. Film thickness was increased to 14 microns, and drift was reduced to less than 0.02 percent of Fahrenheit temperature per hour on actual turbine blades at 1255 K.

Grant, H. P.↗

Thermal monitoring, measurement, and control system for a Volatile Condensable Materials (VCM) test apparatus

A thermal monitoring and control concept is described for a volatile condensable materials (VCM) test apparatus where electric resistance heaters are employed. The technique is computer based, but requires only proportioning ON/OFF relay control signals supplied through a programmable scanner and simple quadrac power controllers. System uniqueness is derived from automatic temperature measurements and the averaging of these measurements in discrete overlapping temperature zones. Overall control tolerance proves to be better than + or - 0.5 C from room ambient temperature to 150 C. Using precisely calibrated thermocouples, the method provides excellent temperature control of a small copper VCM heating plate at 125 + or - 0.2 C over a 24 hr test period. For purposes of unattended operation, the programmable computer/controller provides a continual data printout of system operation. Real time operator command is also provided for, as is automatic shutdown of the system and operator alarm in the event of malfunction.

Ives, R. E.↗

Use of a variable exposure photographic pyrometer to measure surface temperatures on a hemispherical-face model

The use of a photographic pyrometer for nonintrusive measurement of high temperature surfaces in a wind tunnel test is described. The advantages of the pyrometer for measuring surfaces whose unique shape makes use of thermocouples difficult are pointed out. The use of computer operated densitometers or optical processors for the data reduction is recommended.

Kantsios, A. G.↗

Low and medium heating value coal gas catalytic combustor characterization

Catalytic combustion with both low and medium heating value coal gases obtained from an operating gasifier was demonstrated. A practical operating range for efficient operation was determined, and also to identify potential problem areas were identified for consideration during stationary gas turbine engine design. The test rig consists of fuel injectors, a fuel-air premixing section, a catalytic reactor with thermocouple instrumentation and a single point, water cooled sample probe. The test rig included inlet and outlet transition pieces and was designed for installation into an existing test loop.

Schwab, J. A.↗

Comparison of forward fuselage to Space Shuttle Orbiter flight pressure data to wind tunnel and analytical results in the hypersonic Mach number range

The Space Transportation System (STS) test program is unique in that it combines flight testing with operational flights using the first operational orbital vehicle (OV-102). The Space Shuttle Orbiter was instrumented to obtain various types of flight data. The instrumentation, designated Development Flight Instrumentation (DFI) includes pressure transducers, thermocouples, calorimeters, and accelerometers. A comparison is conducted between orbiter DFI forward fuselage flight pressure data obtained from OV-102 during the STS-1 reentry, and ground facility data obtained utilizing a 0.04 scale Orbiter forebody model. The comparisons are used to validate the existing experimental data base, optimize the pressure modeling technique, and make possible the refinement of error analysis relative to both. The obtained results indicate, in general, good agreement between flight and ground-based data.

Bradley, P. F.↗

Development of advanced high-temperature heat flux sensors

Various configurations of high temperature, heat flux sensors were studied to determine their suitability for use in experimental combustor liners of advanced aircraft gas turbine engines. It was determined that embedded thermocouple sensors, laminated sensors, and Gardon gauge sensors, were the most viable candidates. Sensors of all three types were fabricated, calibrated, and endurance tested. All three types of sensors met the fabricability survivability, and accuracy requirements established for their application.

Atkinson, W. H.↗

Heat generation in aircraft tires under free rolling conditions

A method was developed for calculating the internal temperature distribution in an aircraft tire while free rolling under load. The method uses an approximate stress analysis of each point in the tire as it rolls through the contact patch, and from this stress change the mechanical work done on each volume element may be obtained and converted into a heat release rate through a knowledge of material characteristics. The tire cross-section is then considered as a body with internal heat generation, and the diffusion equation is solved numerically with appropriate boundary conditions of the wheel and runway surface. Comparison with data obtained with buried thermocouples in tires shows good agreement.

Clark, S. K.↗

The measurement of the ground wind structure at Wallops Island

The mean and turbulence characteristics of the surface wind measured near the Atlantic coast were measured. The experimental data were acquired from a 76 meter tall instrumented micrometeorological tower. Mean wind and turbulence measurements were made with two types of instrumentation consisting of cup vane and temperature probes, primarily used for mean profile measurements of velocity and temperature respectively. The second system, a hot film and thermocouple system, was used for measurement of turbulence variances and covariances and spectra. The cup vane system was used to acquire data from all wind directions, while the hot film system was primarily used for turbulence measurements from the two prevailing wind directions, south and northwest. The micrometeorological tower is a self standing nonguyed tower with five working platforms at 15.2m (50 ft.) intervals, with cup vane and aspirated temperature probes mounted at each platform.

Tielman, H. W.↗

Development of a rotary instrumentation system, phase 2

A rotary instrumentation system which consists of ruggedized miniature telemetry transmitters installed on the rotating shaft of a gas turbine engine to telemeter the outputs of sensors (strain gages, thermocouples, etc.) on rotating engine components was designed. A small prototype system, which demonstrates the capabilities of performing in the intended environment and demonstrates that the system is expandable to handle about 100 data channels was developed.

Adler, A.↗

Heat generation in aircraft tires

A method was developed for calculating the internal temperature distribution in an aircraft tire while free rolling under load. The method uses an approximate stress analysis of each point in the tire as it rolls through the contact patch, and from this stress change the mechanical work done on each volume element may be obtained and converted into a heat release rate through a knowledge of material characteristics. The tire cross-section is then considered as a body with internal heat generation, and the diffusion equation is solved numerically with appropriate boundary conditions of the wheel and runway surface. Comparison with data obtained with buried thermocouples in tires shows good agreement.

Clark, S. K.↗

Stagnation region gas film cooling: Effects of dimensionless coolant temperature

An experimental investigation was conducted to mode the film cooling performance for a turbine vane leading edge using the stagnation region of a cylinder in cross flow. Experiments were conducted with a single row of spanwise angled (25 deg) coolant holes for a range of the coolant blowing ratio and dimensionless coolant temperature with free stream-to-wall temperature ratio approximately 1.7 and Re sub D = 90000. the cylindrical test surface was instrumented with miniature heat flux gages and wall thermocouples to determine the percentage reduction in the Stanton number as a function of the distance downstream from injection (x/d sub 0) and the location between adjacent holes (z/S). Data from local heat flux measurements are presented for injection from a single row located at 5 deg, 22.9 deg, 40.8 deg, from stagnation using a hole spacing ratio of S/d = 5. The film coolant was injected with T sub c T sub w with a dimensionless coolant temperature in the range 1.18 or equal to theta sub c or equal to 1.56. The data for local Stanton Number Reduction (SNR) showed a significant increase in SNR as theta sub c was increased above 1.0.

Bonnice, M. A.↗

Joining lead wires to thin platinum alloy films

A two step process of joining a lead wire to .000002 m thick platinum alloy film which rests upon an equally thin alumina insulating layer which is adhered to a metal substrate is described. Typically the platinum alloy film forms part of a thermocouple for measuring the surface temperature of a gas turbine airfoil. In the first step the lead wire is deformed 30 to 60% at room temperature while the characteristic one million ohm resistance of the alumina insulating layer is monitored for degradation. In the second step the cold pressed assembly is heated at 865 to 1025 C for 4 to 75 hr in air. During the heating step any degradation of insulating layer resistance may be reversed, provided the resistance was not decreased below 100 ohm in the cold pressing.

Przybyszewski, J. S.↗

J series thruster thermal test results

Test experience with J series ion thrusters have indicated that the present thruster design may result in excessive temperatures in areas which utilize organic materials such as wire insulation, with the resultant outgassing and potential contamination of insulating materials. Further, it appears that thermal data obtained with earlier thruster designs, such as the 700 series thruster, may not be directly applicable to the J series design. Two J series thrusters were fitted with thermocouples and critical temperatures measured for a variety of configurations and operating parameters. Completely enclosing the thruster to reduce facility contamination significantly increased temperatures prompting the selection of a compromise geometry for life testing. The operating parameter having the largest effect on temperatures was discharge power, while beam power affected little else than extraction system temperatures. Several off-normal operating modes were also investigated. Data believed to be sufficient to effectively modify existing thermal models were obtained from the tests.

Bechtel, R. T.↗

An experimental heat-transfer investigation of an advanced winged entry vehicle at Mach 10

Heat-transfer measurements have been made at Mach 10 in air on an instrumented 0.006-scale model of an advanced winged entry vehicle. Data were obtained at 83 thermocouple stations which include locations on the lower and upper surface centerlines, spanwise positions along the lower and upper surfaces of the wing, the lower surface of the body flap, and radial locations on the fuselage. Data were obtained for angles of attack ranging from 0 to 45 deg, sideslip angles of + or - 2 deg, Reynolds numbers of 0.5, 1.0 and 2.0 million per foot, and body-flap deflections of 0, 10, and 20 deg. The data generally indicate increased windward heating and decreased leeside heating with increased angle of attack, significantly increased body-flap heating with deflection angle, and minor variations in heating with sideslip, increasing in magnitude with angle of attack. Windward centerline data are shown to be in fair agreement with results of predictions based on an approximate engineering method.

Wurster, K. E.↗