Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

Non-visual analysis of miniaturized melt wire arrays for in-pile measurement of peak irradiation temperature

As a part of the in-pile instrumentation program, the Idaho National Laboratory (INL) has established in-house capabilities to fabricate and test new advanced manufactured printed sensors for measurement of peak temperature inside the harsh environment of a nuclear test reactor. Although nuclear test reactors may use standard methods that can provide real-time temperature information, such as thermocouples, the need for feedthroughs for real-time measurements greatly increases the cost of the experiment. Some experiments also present the problem of limited space available for instrumentation. To address this need, INL is working to improve temperature detection options for such applications. The lab is developing advanced manufactured melt wire arrays to determine peak temperatures in experiments with limited space. Furthermore, capabilities to print multiple melt wires with different melting properties on a single miniaturized unit is being established. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing.

36 MATERIALS SCIENCE↗

A surface acoustic wave hydrogen sensor with tin doped indium oxide layers for intermediate temperatures

We report high temperature surface acoustic wave (SAW) gas sensors with conducting sensing layers require tuning of the sheet conductivity for optimal response. Conducting metal oxides are attractive sensing materials for their tunable electronic properties and high thermal stability, amongst others. Here, we have investigated the application of indium oxide (IO) and indium tin oxide (ITO) films on langasite (LGS)-based SAW reflective delay line sensor devices for monitoring hydrogen at 350 °C. Specifically, we modeled the effect of the IO and ITO sensing layer thickness on the wave velocity, attenuation, and effective electromechanical coefficient. This was followed by an experimental demonstration of tuning of the ITO film sheet conductivity by controlling the dopant concentration and yielding an improvement in the sensor sensitivity. The current study provides a pathway towards the development of conductivity-based sensing layers for high temperature SAW gas sensors with improved sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Room temperature detection of NO{sub 2} using InSb nanowire

Room temperature detection of NO{sub 2} down to one part-per-million (ppm) using single crystalline n-type InSb nanowires (NWs) chemiresistive gas sensor is presented. These sensors were synthesized and fabricated by the combination of chemical vapor deposition and dielectrophoresis alignment techniques. The sensor devices showed an increase in resistance upon exposure to successive increments of NO{sub 2} concentration up to 10 ppm. The reduction in conductance of n-type InSb NWs when exposed to NO{sub 2} is made possible due to the charge transfer from the InSb NW surface to the adsorbed electron acceptor NO{sub 2} molecules. The demonstrated results suggest InSb NW as a promising candidate in sensing applications as well as being environmental friendly over existing arsenic and/or phosphorous-based III-V NW sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-temperature fiber-optic Fabry-Perot interferometric sensors

A photonic crystal fiber (PCF) based high-temperature fiber-optic sensor is proposed and experimentally demonstrated. The sensor head is a Fabry-Perot cavity manufactured with a short section of endless single-mode photonic crystal fiber (ESM PCF). The interferometric spectrum of the Fabry-Perot interferometer is collected by a charge coupled device linear array based micro spectrometer. A high-resolution demodulation algorithm is used to interrogate the peak wavelengths. Experimental results show that the temperature range of 1200 °C and the temperature resolution of 1 °C are achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless 3D Nanorod Composite Arrays based High Temperature Surface-Acoustic-Wave Sensors for Selective Gas Detection through Machine Learning Algorithms (Final Report)

This is the final scientific and technical report which summarizes the research conducted through this funded project. In this report, we first present the accomplishments of the project, major research activities and specific activities conducted, and then discuss the significant results. We also describe the opportunities for training and professional development provided to the involved students as well as the products produced. Finally, we report the impact of the research on the development of human resources and present the budgetary information.

42 ENGINEERING↗

New Sensors for In-Pile Temperature Detection at the Advanced Test Reactor National Scientific User Facility

The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. As a user facility, the ATR is supporting new users from universities, laboratories, and industry, as they conduct basic and applied nuclear research and development to advance the nation’s energy security needs. A key component of the ATR NSUF effort is to develop and evaluate new in-pile instrumentation techniques that are capable of providing measurements of key parameters during irradiation. This paper describes the strategy for determining what instrumentation is needed and the program for developing new or enhanced sensors that can address these needs. Accomplishments from this program are illustrated by describing new sensors now available and under development for in-pile detection of temperature at various irradiation locations in the ATR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Sensor Allocation for Fault Detection and Isolation

Automatic fault diagnostic schemes rely on various types of sensors (e.g., temperature, pressure, vibration, etc) to measure the system parameters. Efficacy of a diagnostic scheme is largely dependent on the amount and quality of information available from these sensors. The reliability of sensors, as well as the weight, volume, power, and cost constraints, often makes it impractical to monitor a large number of system parameters. An optimized sensor allocation that maximizes the fault diagnosibility, subject to specified weight, volume, power, and cost constraints is required. Use of optimal sensor allocation strategies during the design phase can ensure better diagnostics at a reduced cost for a system incorporating a high degree of built-in testing. In this paper, we propose an approach that employs multiple fault diagnosis (MFD) and optimization techniques for optimal sensor placement for fault detection and isolation (FDI) in complex systems. Keywords: sensor allocation, multiple fault diagnosis, Lagrangian relaxation, approximate belief revision, multidimensional knapsack problem.

Azam, Mohammad↗

SOAREX-8 Suborbital Experiments 2015 - A New Paradigm for Small Spacecraft Communication

In 2015 NASA plans to launch a payload to 280 Km altitude on a sounding rocket from the Wallops Flight Facility. This payload will contain several novel technologies that work together to demonstrate methodologies for space sample return missions and for nanosatellite communications in general. The payload will deploy and test an Exo-Brake, which slows the payload aerodynamically, providing eventual de-orbit and recovery of future ISS samples through a Small Payload Quick Return project. In addition, this flight addresses future Mars mission entry technology, space-to-space communications using the Iridium Short Messaging Service (SMS), GPS tracking, and wireless sensors using the ZigBee protocol. SOAREX-8 is being assembled and tested at Ames Research Center (ARC) and the NASA Engineering and Safety Center (NESC) is funding sensor and communications work. Open source Arduino technology and software are used for system control. The ZigBee modules used are XBee units that connect analog sensors for temperature, air pressure and acceleration measurement wirelessly to the payload telemetry system. Our team is developing methods for power distribution and module mounting, along with software for sensor integration, data assembly and downlink. We have demonstrated relaying telemetry to the ground using the Iridium satellite constellation on a previous flight, but the upcoming flight will be the first time we integrate useful flight test data from a ZigBee wireless sensor network. Wireless sensor data will measure the aerodynamic efficacy of the Exo-Brake permitting further on orbit flight tests of improved designs. The Exo-Brake is 5 sq m in area and will be stored in a container and deployed during ascent once the payload is jettisoned from the launch vehicle. We intend to further refine the hardware and continue testing on balloon launches, future sounding rocket flights and on nanosatellite missions. The use of standards-based and open source hardware/software has allowed for this project to be completed with a very modest budget and a challenging schedule. There is a wealth of hardware and software available for both the Arduino platform and the XBee, all low-cost or open-source. Along with the Exo-Brake hardware and deployment discussion, this paper will describe in detail the system architecture emphasizing the successful use of open source hardware and software to minimize effort and cost. Testing procedures, radio frequency interference (RFI) mitigation, success criteria and expected results will also be discussed. The use of Iridium short messaging capability for space-to-space links, standards-based wireless sensor networks, and other innovative communications technology are also presented.

aerobrake↗

Multiplexed Sensor for Synthesis Gas Compsition and Temperature

The overall goal of this project has been to develop a highly sensitive, multiplexed TDL-based sensor for CO{sub 2}, CO, H{sub 2}O (and temperature), CH{sub 4}, H{sub 2}S, and NH{sub 3}. Such a sensor was designed with so-called 'plug-and-play' characteristics to accommodate additional sensors, and provided in situ path-integrated measurements indicative of average concentrations at speeds suitable for direct gasifier control. The project developed the sensor and culminated in a real-world test of the underlying technology behind the sensor. During the project, new underlying measurements of spectroscopic constants for all of the gases of interest performed, in custom cells built for the project. The envisioned instrument was built from scratch from component lasers, fiber optics, amplifier blocks, detectors, etc. The sensor was tested for nearly a week in an operational power plant. The products of this research are expected to have a direct impact on gasifier technology and the production of high-quality syngas, with substantial broader application to coal and other energy systems. This report is the final technical report on project DE-FG26-04NT42172. During the project we completed all of the milestones planned in the project, with a modification of milestone (7) required due to lack of funding and personnel.

01 COAL, LIGNITE, AND PEAT↗

Differential temperature stress measurement employing array sensor with local offset

The instrument has a focal plane array of infrared sensors of the integrating type such as a multiplexed device in which a charge is built up on a capacitor which is proportional to the total number of photons which that sensor is exposed to between read-out cycles. The infrared sensors of the array are manufactured as part of an overall array which is part of a micro-electronic device. The sensor achieves greater sensitivity by applying a local offset to the output of each sensor before it is converted into a digital word. The offset which is applied to each sensor will typically be the sensor's average value so that the digital signal which is periodically read from each sensor of the array corresponds to the portion of the signal which is varying in time. With proper synchronization between the cyclical loading of the test object and the frame rate of the infrared array the output of the A/D converted signal will correspond to the stress field induced temperature variations. A digital lock-in operation may be performed on the output of each sensor in the array. This results in a test instrument which can rapidly form a precise image of the thermoelastic stresses in an object.

Lesniak, Jon R.↗

Shuttle sensors

Requirements, quantities, location, and temperature environment limitations of sensors for space shuttles

Melliff, V. C., Jr.↗

Spinoff 2010

Topics covered include: Burnishing Techniques Strengthen Hip Implants; Signal Processing Methods Monitor Cranial Pressure; Ultraviolet-Blocking Lenses Protect, Enhance Vision; Hyperspectral Systems Increase Imaging Capabilities; Programs Model the Future of Air Traffic Management; Tail Rotor Airfoils Stabilize Helicopters, Reduce Noise; Personal Aircraft Point to the Future of Transportation; Ducted Fan Designs Lead to Potential New Vehicles; Winglets Save Billions of Dollars in Fuel Costs; Sensor Systems Collect Critical Aerodynamics Data; Coatings Extend Life of Engines and Infrastructure; Radiometers Optimize Local Weather Prediction; Energy-Efficient Systems Eliminate Icing Danger for UAVs; Rocket-Powered Parachutes Rescue Entire Planes; Technologies Advance UAVs for Science, Military; Inflatable Antennas Support Emergency Communication; Smart Sensors Assess Structural Health; Hand-Held Devices Detect Explosives and Chemical Agents; Terahertz Tools Advance Imaging for Security, Industry; LED Systems Target Plant Growth; Aerogels Insulate Against Extreme Temperatures; Image Sensors Enhance Camera Technologies; Lightweight Material Patches Allow for Quick Repairs; Nanomaterials Transform Hairstyling Tools; Do-It-Yourself Additives Recharge Auto Air Conditioning; Systems Analyze Water Quality in Real Time; Compact Radiometers Expand Climate Knowledge; Energy Servers Deliver Clean, Affordable Power; Solutions Remediate Contaminated Groundwater; Bacteria Provide Cleanup of Oil Spills, Wastewater; Reflective Coatings Protect People and Animals; Innovative Techniques Simplify Vibration Analysis; Modeling Tools Predict Flow in Fluid Dynamics; Verification Tools Secure Online Shopping, Banking; Toolsets Maintain Health of Complex Systems; Framework Resources Multiply Computing Power; Tools Automate Spacecraft Testing, Operation; GPS Software Packages Deliver Positioning Solutions; Solid-State Recorders Enhance Scientific Data Collection; Computer Models Simulate Fine Particle Dispersion; Composite Sandwich Technologies Lighten Components; Cameras Reveal Elements in the Short Wave Infrared; Deformable Mirrors Correct Optical Distortions; Stitching Techniques Advance Optics Manufacturing; Compact, Robust Chips Integrate Optical Functions; Fuel Cell Stations Automate Processes, Catalyst Testing; Onboard Systems Record Unique Videos of Space Missions; Space Research Results Purify Semiconductor Materials; and Toolkits Control Motion of Complex Robotics.

Source record↗

Temperature compensated and self-calibrated current sensor using reference magnetic field

A method is described to provide temperature compensation and self-calibration of a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. A reference magnetic field generated within the current sensor housing is detected by the magnetic field sensors and is used to correct variations in the output signal due to temperature variations and aging.

47 OTHER INSTRUMENTATION↗

Error in temperature measurements due to conduction along the sensors

When a sensor is embedded in a solid body to measure its internal temperature, any conduction to or from its sensing element may cause the indicated temperature to be different from the true temperature. This paper describes an analysis of the error caused by conduction when there is an arbitrary temperature distribution in the body along the sensor. The sensor is modeled as a cylindrical fin and the appropriate conduction equation is solved. The solution gives a correction for the error which depends on such parameters as, depth of immersion, thermocouple wire and insulation properties, contact between the sensor and the body, and temperature distribution in the body. The latter may not be known, but the measured temperature distribution can be used as a first approximation. The corrected value can then be used to obtain a better estimate of the error. The results show good agreement with experimental observations.

Singh, B. S.↗

Marine Corps Base Camp Lejeune New River Estuary - Acoustic Doppler Current Profiler (ADCP) Results

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of development pressures in surrounding areas, impairments due to other anthropogenic disturbances, and increasing requirements for compliance with environmental regulations. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and to optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a minimum 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the first six years of the program (DCERP1) are presented here.The overarching objectives of DCERP are to: (1) understand the effects of military training activities, infrastructure development, and other coastal military installations; (2) develop models, tools, and indicators to evaluate ecosystem health; and (3) recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.This data package contains a zipfile of results from Acoustic Doppler Current Profilers (ADCPs) used to collect current profiles throughout the New River Estuary in 2009: Teledyne RD Instrument’s acoustic Doppler current profilers (ADCPs) were deployed throughout the NRE to understand current flows and tidal extent. (Current velocity and water level data collected by the ADCPs were also used to validate a hydrodynamic model of the NRE.) Two ADCPS were deployed by Marker 12 and the Highway 172 bridge from late-February to early-July 2009. These ADCPs were attached to steel frames that rested on the sediment surface with the ADCP looking upward to make full water column profiles of water velocity minus a 1-m blanking between the instrument and sediment surface. Also attached to the steel frames were conductivity-temperature-depth (CTD) sensors, which provided concomitant salinity, temperature, and water depth data with the ADCP current measurements. Two ADCPS were also deployed in close proximity to the AVPs in Stones and Morgan Bays from mid-July to mid-December 2009. These ADCPs were deployed flush to the estuary floor to maximize the full vertical sampling capability at these shallow stations and the AVPs collected coincidental temperature, salinity, and depth measurements. For all deployments, the ADCPs were programmed in fast ping-rate mode 12 using 20 pings per ensemble and collected profiles in 10-cm bins every 6 minutes yielding a standard deviation in velocity measurements of 1.27 cm s-1. Current velocity and water level data were analyzed to understand the tidal influence on circulation within the NRE. Harmonic analyses were performed to extract the dominant tidal constituents from the velocity and depth records using T-tide run in MATLAB (Pawlowicz et al., 2002). These measurements of tidal amplitude and phase were then used to validate the high-resolution Advanced Circulation (ADCIRC) Model of the NRE region.

54 ENVIRONMENTAL SCIENCES↗