Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Descriptor: High Temporal Resolution Meteorological Data at Oak Ridge Reservation (ORR-HiResMet)

Access to continuous, quality assessed meteorological data is critical for understanding the climatology and atmospheric dynamics of a region. Research facilities like Oak Ridge National Laboratory (ORNL) rely on such data to assess site-specific climatology, model potential emissions, establish safety baselines, and prepare for emergency scenarios. To meet these needs, on-site towers at ORNL collect meteorological data at 15-minute and hourly intervals. However, data measurements from meteorological towers are affected by sensor sensitivity, degradation, lightning strikes, power fluctuations, glitching, and sensor failures, all of which can affect data quality. To address these challenges, we conducted a comprehensive quality assessment and processing of five years of meteorological data collected from ORNL at 15-minute intervals, including measurements of temperature, pressure, humidity, wind, and solar radiation. The time series of each variable was pre-processed and gap-filled using established meteorological data collection and cleaning techniques, i.e., the time series were subjected to structural standardization, data integrity testing, automated and manual outlier detection, and gap-filling. The data product and highly generalizable processing workflow developed in Python Jupyter notebooks are publicly accessible online. As a key contribution of this study, the evaluated 5-year data will be used to train atmospheric dispersion models that simulate dispersion dynamics across the complex ridge-and-valley topography of the Oak Ridge Reservation in East Tennessee.

Steckler, Morgan R. [Oak Ridge National Laboratory↗

A Step Towards Machine Learning-based Coherent Generator Grouping for Emergency Control Applications in Modern Power Grid

A dynamic neural network (NN) based multi-class classifier is proposed for improving online prediction of coherent generator groups (CGGs), following the occurrences of various contingencies in the power grid. This is motivated by the increasing availability of the measurements from phasor measurement units (PMUs) and the number of grouping schemes is limited. The proposed method consists of three steps. First, by performing offline simulations, a library of system dynamic responses characterized by post-contingency rotor angles and speeds of individual generators is obtained. To generate sufficient data, up to N-2 contingencies and the uncertain parameters associated with the power grid including type and location of disturbance and fault clearing times are modeled. Secondly, the training data-set is produced by generating labels for individual contingencies using a hierarchical clustering method based on rotor angle and speed data. Lastly, the dynamic NN models are trained for online applications such as emergency controls and controlled islanding. The proposed method is tested on the standard 16-generator 68-bus system to demonstrate its performance. Furthermore, the impact of the sample data lengths on the CGG numbers is evaluated. It is interesting to observe that the time domain stability behaviors can be determined by examining the changes in the CGG numbers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC

This paper presents a high-frequency modular medium-voltage AC (4160 VAC or 13.8 kVAC) to low-voltage DC (400 VDC) system that is scalable in order to be used for different scale microgrids. A 15 kW, 500 kHz DC/DC converter is demonstrated as the most important stage of the system overall, which can be scalable to a 225 kW 4160 VAC to 400 VDC system. Motivation of a CLLC resonant converter and its design parameters determination is carefully illustrated. The high-frequency transformer is the key element for the DC/DC converter. Then, the paper focuses on high-frequency transformer design to realize high-voltage insulation, high efficiency, and high density at the same time. Based on a split winding UU core transformer structure, transformer insulation materials and dimension parameters are determined referring to the IEEE insulation standard. The transformer magnetic loss model is reviewed based on which loss design tradeoff is carefully analyzed. Different working frequency impact on transformer design over three different core materials is also presented. Finally, a 500 kHz transformer prototype has been developed and demonstrated with the IEEE standard required insulation tests. A whole CLLC resonant converter is also present with experiments results. Here, the converter holds outstanding 98% efficiency and 2.9 kW/L power density.

42 ENGINEERING↗

The liquidus temperature of nuclear waste glasses: an international Round-Robin Study

Ten institutions from five countries participated in a Round Robin study to contribute to the Precision and Bias section of an American Society for Testing and Materials standard procedure that Pacific Northwest National Laboratory (PNNL) is developing for measuring the liquidus temperature (TL) of radioactive and simulated waste glasses. In this study, three separate TL measurement methods were a gradient temperature (GT) method, a uniform temperature (UT) method, and a crystal fraction extrapolation (CF) method. Three different glasses were measured with a combination of these three methods. The TL values reported by different institutions are generally consistent and vary within a narrow range. The precision of a TL measurement was evaluated as ±10°C regardless of the method used for making the measurement. The Round Robin glasses were all previously studied at PNNL and included ARG-1 (Glass A), Zr-9 (Glass B), and AmCm2-19 (Glass C), with measured TL values spanning the temperature range ~960-1240°C. The three methods discussed here in more detail are the GT, UT, and CF methods. A best-case precision for TL has been obtained from the data, even though the data were not acquired for all three glasses using all three methods from each participating organization.

ASTM↗

Sulphate resistance of low‐clinker engineered cementitious composites examined by MicroXRF imaging

Abstract Engineered cementitious composites (ECC) are a class of high‐performing fibre‐reinforced cementitious materials recognised for their increased ductility and durability compared to conventional cement‐based materials, owing to their autogenously controlled tight crack widths, even when subjected to high strains. To reduce ECC's environmental impact, this research examines the use of a low‐clinker binder − limestone‐calcined clay cement (LC3) − as an alternative to portland cement (PC), along with fly ash to further reduce the clinker proportion and the embodied CO 2 of the formulations. In conventional concrete, LC3 hydrates to a denser microstructure resulting from the synergistic reaction between limestone and calcined clay. At the lower water contents typical of ECC and with the presence of fly ash, the influence of the binder composition on the microstructure is difficult to anticipate. To examine the influence of these compositional variables on microstructure, permeability and durability, the sulphate resistance of LC3‐based ECC is explored. Specifically, the ECC‐LC3 blends are designed with high clinker replacement rate of 75% by mass of binder and contain either conventional fly ash or reclaimed fly ash at 50% by mass of binder. Expansion of ECC‐LC3 samples subjected to standard sodium sulphate test conditions was measured up to 12 months and the depth of penetration of sulphates into the ECC‐LC3 of varying compositions was quantified using micro‐X‐Ray Fluorescence (microXRF) imaging and modelling. The expansion results show that the ECC‐LC3 formulations performed better than the PC samples and can provide adequate resistance to external sulphate attack, even when reclaimed fly ashes are used in place of the conventional ash. In addition, the shallow penetration of sulphate into these cementitious composites demonstrates the low diffusion coefficients values that were determined using the quantitative data from MicroXRF imaging.

Microscopy↗

A material interface transition algorithm for multiphase flow

Volume tracking method, also referred to as the volume-of-fluid (VOF) method introduces 'numerical surface tension' that breaks a filament into a series of droplets whenever the filament is under-resolved. Adaptive mesh refinement can help avoid under-resolution, but a fully-developed flow will still generate filaments that cannot be resolved without enormous computational cost. We propose a complementary new approach that consists of transitioning to a continuous interface representation (i.e. without interface reconstruction) in regions of under-resolved interfacial curvature where volume tracking has become erroneous. The price of the continuous interface treatment is a small amount of numerica'l mass diffusion, even if the physical interface is immiscible. However, we have found that for certain measures, the overall accuracy is greatly improved by using our transitioning algorithm. The algorithm is developed in the context of the single fluid formulation of the incompressible Navier-Stokes equations. Numerical standard vortices advection test cases and Rayleigh-Taylor instability computations are presented to illustrate the transition algorithm potential.

42 ENGINEERING↗

SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.

61 RADIATION PROTECTION AND DOSIMETRY↗

The P2 experiment: A future high-precision measurement of the weak mixing angle at low momentum transfer

Here we describe the research and development work for the P 2 experiment which aims for a high precision determination of the weak mixing angle sin 2 θ W to a precision of 0.15% at a four-momentum transfer of 4.5×10 –3 GeV 2 . This accuracy, comparable to existing measurements at the Z pole, allows for a sensitive test of the Standard Model up to a mass scale of 50 TeV, extendable to 60 TeV. The weak mixing angle is connected to the weak charge of the proton which will be extracted from a measurement of the parity violating cross section asymmetry –39.94×10 –9 in elastic electron-proton scattering. A total accuracy of 0.57×10 –9 is achievable in a measurement time of 11000 h using a 150μA polarized electron beam impinging on a 60 cm liquid hydrogen target. The P 2 asymmetry is smaller than any asymmetry measured so far in electron scattering with an unprecedented goal for the accuracy. The use of a solenoid spectrometer with 100% Φ-acceptance as well as an atomic hydrogen trap polarimeter are new features, which have never before been used in parity-violation experiments. In order to collect the enormous statistics required for this measurement, the new Mainz Energy-Recovering Superconducting Accelerator (MESA) is under construction. Plans for the associated beam control system and the polarimetry are described in this article as well. A liquid hydrogen high-power target with an extremely low noise level of 10 ppm needs to be designed and constructed. We report in addition on the conceptual design of the P 2 spectrometer, its Cherenkov detectors, the integrating read-out electronics as well as the ultra-thin, fast tracking detectors. The physics program of the MESA facility comprises indirect, high precision search for physics beyond the Standard Model, measurement of the neutron distribution in nuclear physics, single-spin asymmetries, and a possible future extension to the measurement of hadronic parity violation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QCD precision measurements and structure function extraction at a high statistics, high energy neutrino scattering experiment: NuSOnG.

We extend the physics case for a new high-energy, ultra-high statistics neutrino scattering experiment, NuSOnG (Neutrino Scattering On Glass) to address a variety of issues including precision QCD measurements, extraction of structure functions, and the derived Parton Distribution Functions (PDF's). This experiment uses a Tevatron-based neutrino beam to obtain a sample of Deep Inelastic Scattering (DIS) events which is over two orders of magnitude larger than past samples. We outline an innovative method for fitting the structure functions using a parametrized energy shift which yields reduced systematic uncertainties. High statistics measurements, in combination with improved systematics, will enable NuSOnG to perform discerning tests of fundamental Standard Model parameters as we search for deviations which may hint of 'Beyond the Standard Model' physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stability of Atomically Dispersed Fe–N–C ORR Catalyst in Polymer Electrolyte Fuel Cell Environment

We have investigated the durability of a platinum group metal (PGM-)free Fe–N–C catalyst in which the Fe sites are atomically dispersed (AD), and found it to be quite stable in standard accelerated stress test (AST) cycles normally used for low-PGM catalysts: a square wave with 0.6 V lower potential limit (LPL)—0.95 V upper potential limit (UPL) with 3-s holds at UPL and LPL in H 2 /N 2 , at 1.5 atm, 80 °C and 100% RH. Considering the metrics normally employed to characterize the durability of the low-PGM catalysts after 30,000 AST cycles, this PGM-free catalyst lost <50% catalyst activity, <50% H 2 /air performance at 0.8 V, and 40 mV at 1.5 A cm -2 . However, it is less stable in H 2 /air, losing ~50% catalyst activity after just 7.5 h of polarization measurements (load cycles). In combined cycles, the majority of the loss in catalyst activity occurred during the load cycles in H 2 /air rather than AST cycles in H 2 /N 2 . We have concluded that, unlike low-PGM catalysts that lose electrochemically active surface area (ECSA) through potential cycling-induced processes, (AD)Fe–N–C catalysts degrade by processes associated with the presence of oxygen.

25 ENERGY STORAGE↗

Baselining Activity and Stability of ORR Catalysts and Electrodes for Proton Exchange Membrane Fuel Cells for Heavy-Duty Applications

Activity and stability of electrodes with Pt and PtCo alloy catalysts supported on high surface area carbon, hereafter to as a-Pt/C and d-PtCo/C, were evaluated for heavy-duty applications. Both catalysts had nearly identical Pt loading (50-wt% Pt on carbon and 0.25 mg Pt cm −2 ) and had undergone thermal treatment to stabilize them by growing the average particle size to 4–5 nm. Both were subjected to 90,000 (90 k) standard accelerated stress tests (AST) cycles consisting of 0.6–0.95 V square wave potentials, 3-s hold at upper and lower potential limits in H 2 /N 2 at 1.5 atm, 80 °C and 100% RH. Test protocols were developed to monitor the performance losses and characterize them in terms of activity for the oxygen reduction reaction (ORR), oxygen transport in the electrode and proton transport in the membrane and cathode catalyst layer. Despite the nearly double initial ORR activity, the PtCo/C electrode degraded faster due to the leaching of Co from the catalyst that had started even before the imposition of the AST potential cycles. Commensurate with Co leaching, Co poisoning of ionomer is responsible for the inferior performance of d-PtCo/C electrode at high current densities both before and after AST.

30 DIRECT ENERGY CONVERSION↗

Universal Automated Refrigerator Door Opener

This creation is used for standard energy performance tests of household and commercial refrigerators and other refrigeration equipment. It automates the door opening at a preset duration and velocity specified by the test procedure.

Wang, Duo↗

Web-Based Reanalysis Intercomparison Tools (WRIT) for Analysis and Comparison of Reanalyses and Other Datasets

While atmospheric reanalysis datasets are widely used in climate science, many technical issues hinder comparing them to each other and to observations. The reanalysis fields are stored in diverse file architectures, data formats, and resolutions. Their metadata, such as variable name and units, can also differ. Individual users have to download the fields, convert them to a common format, store them locally, change variable names, regrid if needed, and convert units. Even if a dataset can be read via the Open-Source Project for a Network Data Access Protocol (commonly known as OPeNDAP) or a similar protocol, most of this work is still needed. All of these tasks take time, effort, and money. Our group at the Cooperative Institute for Research in the Environmental Sciences at the University of Colorado and affiliated colleagues at the NOAA's Earth System Research Laboratory Physical Sciences Division have expertise both in making reanalysis datasets available and in creating web-based climate analysis tools that have been widely used throughout the meteorological community. To overcome some of the obstacles in reanalysis intercomparison, we have created a set of web-based Reanalysis Intercomparison Tools (WRIT) at www.esrl.noaa.gov/psd/data/writ/. WRIT allows users to easily plot and compare reanalysis datasets, and to test hypotheses. For standard pressure-level and surface variables there are tools to plot trajectories, monthly mean maps and vertical cross sections, and monthly mean time series. Some observational datasets are also included. Users can refine date, statistics, and plotting options. WRIT also facilitates the mission of the Reanalyses.org website as a convenient toolkit for studying the reanalysis datasets.

54 ENVIRONMENTAL SCIENCES↗

Surface reflectance degradation by microbial communities

Building envelope, such as a roof, is the interface between a building structure and the environment. Understanding of the physics of microbial interactions with the building envelope is limited. In addition to the natural weathering, microorganisms and airborne particulate matter that attach to a cool roof tend to reduce the roof reflectance over time, compromising the energy efficiency advantages of the reflective coating designs. We applied microbial ecology analysis to identify the natural communities present on the exposed coatings and investigated the reduction kinetics of the surface reflectance upon the introduction of a defined mixture of both photoautotrophic and heterotrophic microorganisms representing the natural communities. The result are (1) reflectance degradation by microbial communities follows a first-order kinetic relationship and (2) more than 50% of degradation from the initial reflectance value can be caused by microbial species alone in much less time than 3 years required by the current standard ENERGY STAR® test methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Many but not all deep neural network audio models capture brain responses and exhibit correspondence between model stages and brain regions

Models that predict brain responses to stimuli provide one measure of understanding of a sensory system and have many potential applications in science and engineering. Deep artificial neural networks have emerged as the leading such predictive models of the visual system but are less explored in audition. Prior work provided examples of audio-trained neural networks that produced good predictions of auditory cortical fMRI responses and exhibited correspondence between model stages and brain regions, but left it unclear whether these results generalize to other neural network models and, thus, how to further improve models in this domain. We evaluated model-brain correspondence for publicly available audio neural network models along with in-house models trained on 4 different tasks. Most tested models outpredicted standard spectromporal filter-bank models of auditory cortex and exhibited systematic model-brain correspondence: Middle stages best predicted primary auditory cortex, while deep stages best predicted non-primary cortex. However, some state-of-the-art models produced substantially worse brain predictions. Models trained to recognize speech in background noise produced better brain predictions than models trained to recognize speech in quiet, potentially because hearing in noise imposes constraints on biological auditory representations. The training task influenced the prediction quality for specific cortical tuning properties, with best overall predictions resulting from models trained on multiple tasks. The results generally support the promise of deep neural networks as models of audition, though they also indicate that current models do not explain auditory cortical responses in their entirety.

59 BASIC BIOLOGICAL SCIENCES↗

The Jefferson Lab 12 GeV program on nucleon structure

This slide-show presents the experiments planned at JLab with their 12 GeV upgrade. Experiments reported address: the use of hadron spectra as probes of QCD; the transverse structure of hadrons; the longitudinal structure of hadrons; the 3-dimensional structure of hadrons; hadrons and cold nuclear matter; and low-energy tests of the Standard Model and fundamental symmetries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the anomalous spin precession frequency $\omega_a$ in the Muon g - 2 experiment at Fermilab

The muon magnetic anomaly aµ = (gµ - 2)/2 is a low-energy observable,which can be both measured and computed to high precision, making ita sensitive test of the Standard Model (SM). In April 2021, the E989 Collaborationat Fermilab National Accelerator Laboratory (FNAL) published the first resultbased on the first year of data taking (Run-1), and in August 2023 a new resultwas published based on two more years of data taking (Run-2 and Run-3). Thenew result was in agreement with the first one and with the previous experimentat Brookhaven National Laboratory (BNL), and the combination of these resultsbrought the uncertainty on the experimental measurement of aµ to the unprecedentedvalue of 0.19 parts per million (ppm). This paper will present details aboutthe improvements and upgrades since the 2021 result, and it will describe the finalstatistical and systematic sources of uncertainty on .a in the 2023 result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗