Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber Using Photogrammetry

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a late 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (< 0.3 deg at 90 GHz.) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformations to be resolved by the measurement system were on the order of +/- 0.030 inches (0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. A photogrammetry (PG) system was chosen to perform the measurements since it is a non-contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The PG measurements met the desired requirements, enabling the desired deformations to be measured and even resolved to an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

Hill, Michael D.↗

Numerical Model for Isothermal and Non-Isothermal Crystallization of Liquids and Glasses

A new numerical model of isothermal and non-isothermal first order phase transformations, such as the crystallization of liquids and glasses, is presented. This model computes directly the volume fraction transformed, taking into account time-dependent nucleation rates and cluster-size-dependent growth velocities. The model is applied to the crystallization of lithium disilicate glass, using the appropriate kinetic and thermodynamic parameters. The model is used (1) to determine the validity of common methods for computing the volume fraction transformed as a function of time in isothermal experiments when a time-dependent nucleation rate is expected, (2) to simulate non-isothermal differential scanning calorimetry (DSC) studies of glass devitrification as a function of scan rate, and (3) to compute the effect of preannealing on the DSC peak parameters. A novel behavior of the nucleation rate with scan rate is predicted, arising because the relaxation of the cluster distribution cannot be described by a single relaxation time. Comparisons of the calculations with experimental data on this glass demonstrate the validity of the model.

Kelton, K. F.↗

Progress Towards a Cartesian Cut-Cell Method for Viscous Compressible Flow

The proposed paper reports advances in developing a method for high Reynolds number compressible viscous flow simulations using a Cartesian cut-cell method with embedded boundaries. This preliminary work focuses on accuracy of the discretization near solid wall boundaries. A model problem is used to investigate the accuracy of various difference stencils for second derivatives and to guide development of the discretization of the viscous terms in the Navier-Stokes equations. Near walls, quadratic reconstruction in the wall-normal direction is used to mitigate mesh irregularity and yields smooth skin friction distributions along the body. Multigrid performance is demonstrated using second-order coarse grid operators combined with second-order restriction and prolongation operators. Preliminary verification and validation for the method is demonstrated using flat-plate and airfoil examples at compressible Mach numbers. Simulations of flow on laminar and turbulent flat plates show skin friction and velocity profiles compared with those from boundary-layer theory. Airfoil simulations are performed at laminar and turbulent Reynolds numbers with results compared to both other simulations and experimental data

Berger, Marsha↗

w18_empower-aids - HIV Envelope at Multiple Scales [Slides]

Being the sole viral protein entity expressed on the surface of the Human Immunodeficiency Virus (HIV) envelope, the Envelope Glycoprotein (Env) remains the only plausible immunological target. Nevertheless, extreme dynamic heterogeneity, structural complexity, and system size make the study of these glycoproteins immensely challenging. We have utilized the Institutional Computing (IC) resources to overcome some of these challenges in computational modeling of the Env glycoproteins. This integrated technique can sufficiently sample a physiologically relevant conformational space accessible to carbohydrates, in a very short time. This method has been validated by quantitatively comparing to experimental cryoEM maps of the HIV Env protein. We have employed graph theory to capture the glycan shield topological network, pinpoint potential interaction pathways, and identify concerted behavior of the glycans. Analyses of various network attributes, such as relative centrality of different glycan positions, identification of communities, and critical subnetwork features, have aided in detailed examination of the glycan shield. Starting from select structures modeled by the pipeline, we are performing large-scale atomistic MD simulations to study the temporal behavior of this system, which will help elucidate biologically relevant antibody behavior. This method can be seamlessly extended to benefit research in Zika, Ebola and other high-density glycosylated systems.

59 BASIC BIOLOGICAL SCIENCES↗

Using Temperature Sensitive Paint Technology

New facilities and test techniques afford research aerodynamicists many opportunities to investigate complex aerodynamic phenomena. For example, NASA Langley Research Center's National Transonic Facility (NTF) can hold Mach number, Reynolds number, dynamic pressure, stagnation temperature and stagnation pressure constant during testing. This is important because the wing twist associated with model construction may mask important Reynolds number effects associated with the flight vehicle. Beyond this, the NTF's ability to vary Reynolds number allows for important research into the study of boundary layer transition. The capabilities of facilities such as the NTF coupled with test techniques such as temperature sensitive paint yield data that can be applied not only to vehicle design but also to validation of computational methods. Development of Luminescent Paint Technology for acquiring pressure and temperature measurements began in the mid-1980s. While pressure sensitive luminescent paints (PSP) were being developed to acquire data for aerodynamic performance and loads, temperature sensitive luminescent paints (TSP) have been used for a much broader range of applications. For example, TSP has been used to acquire surface temperature data to determine the heating due to rotating parts in various types of mechanical systems. It has been used to determine the heating pattern(s) on circuit boards. And, it has been used in boundary layer analysis and applied to the validation of full-scale flight performance predictions. That is, data acquired on the same model can be used to develop trends from off design to full scale flight Reynolds number, e.g. to show the progression of boundary layer transition. A discussion of issues related to successfully setting-up TSP tests and using TSP systems for boundary layer studies is included in this paper, as well as results from a variety of TSP tests. TSP images included in this paper are all grey-scale so that similar to pictures from sublimating chemical tests areas of laminar flow appear "lighter," or white, and areas of turbulent flow appear "darker."

Hamner, M. P.↗

Update on the Benchmark Analysis of the Jupiter Experiments: Plutonium Moderated by Lead

The Jupiter experiment was a series of measurements in the summer of 2017 to analyze the effects of voids in lead moderated plutonium assemblies. This experiment was part of a larger campaign that took place at the National Criticality Experiments Research Center (NCERC) in collaboration with the Japan Atomic Energy Agency (JAEA) that also investigated assemblies with differing uranium enrichments. The purpose for this campaign was to provide data useful for a potential lead-bismuth cooled accelerator driven system. This data is needed due to the low number of benchmarks involving lead. Given the wide use of lead for shielding in addition to new reactor designs, there is a need for further benchmarking that this experiment could help fulfill. In addition, adding more benchmarks to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) is helpful for further validation of simulation methods used for criticality safety. This summary is an update on the current progress of this analysis, and all results shown are preliminary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of two-dimensional and three-dimensional droplet trajectory calculations in the vicinity of finite wings

Computational predictions of ice accretion on flying aircraft most commonly rely on modeling in 2D. These 2D methods treat an aircraft geometry either as wing-like with infinite span, or as an axisymmetric body. Recently, fully 3D methods have been introduced that model an aircraft's true 3D shape. Because 3D methods are more computationally expensive than 2D methods, 2D methods continue to be widely used. However, a 3D method allows investigation of whether it is valid to continue applying 2D methods to a finite wing. The extent of disagreement between LEWICE, a 2D method, and LEWICE3D, a 3D method, in calculating local collection efficiencies at the leading edge of finite wings is investigated.

Mohler, Stanley R., Jr.↗

An extended Lagrangian method

A unique formulation of describing fluid motion is presented. The method, referred to as 'extended Lagrangian method', is interesting from both theoretical and numerical points of view. The formulation offers accuracy in numerical solution by avoiding numerical diffusion resulting from mixing of fluxes in the Eulerian description. Meanwhile, it also avoids the inaccuracy incurred due to geometry and variable interpolations used by the previous Lagrangian methods. Unlike the Lagrangian method previously imposed which is valid only for supersonic flows, the present method is general and capable of treating subsonic flows as well as supersonic flows. The method proposed in this paper is robust and stable. It automatically adapts to flow features without resorting to clustering, thereby maintaining rather uniform grid spacing throughout and large time step. Moreover, the method is shown to resolve multi-dimensional discontinuities with a high level of accuracy, similar to that found in one-dimensional problems.

Liou, Meng-Sing↗

Robust Requirements Tracing via Internet Search Technology: Improving an IV and V Technique

There are three major objectives to this phase of the work. (1) Improvement of Information Retrieval (IR) methods for Independent Verification and Validation (IV&V) requirements tracing. Information Retrieval methods are typically developed for very large (order of millions - tens of millions and more documents) document collections and therefore, most successfully used methods somewhat sacrifice precision and recall in order to achieve efficiency. At the same time typical IR systems treat all user queries as independent of each other and assume that relevance of documents to queries is subjective for each user. The IV&V requirements tracing problem has a much smaller data set to operate on, even for large software development projects; the set of queries is predetermined by the high-level specification document and individual requirements considered as query input to IR methods are not necessarily independent from each other. Namely, knowledge about the links for one requirement may be helpful in determining the links of another requirement. Finally, while the final decision on the exact form of the traceability matrix still belongs to the IV&V analyst, his/her decisions are much less arbitrary than those of an Internet search engine user. All this suggests that the information available to us in the framework of the IV&V tracing problem can be successfully leveraged to enhance standard IR techniques, which in turn would lead to increased recall and precision. We developed several new methods during Phase II; (2) IV&V requirements tracing IR toolkit. Based on the methods developed in Phase I and their improvements developed in Phase II, we built a toolkit of IR methods for IV&V requirements tracing. The toolkit has been integrated, at the data level, with SAIC's SuperTracePlus (STP) tool; (3) Toolkit testing. We tested the methods included in the IV&V requirements tracing IR toolkit on a number of projects.

Hayes, Jane↗

Validation of highly reliable, real-time knowledge-based systems

Knowledge-based systems have the potential to greatly increase the capabilities of future aircraft and spacecraft and to significantly reduce support manpower needed for the space station and other space missions. However, a credible validation methodology must be developed before knowledge-based systems can be used for life- or mission-critical applications. Experience with conventional software has shown that the use of good software engineering techniques and static analysis tools can greatly reduce the time needed for testing and simulation of a system. Since exhaustive testing is infeasible, reliability must be built into the software during the design and implementation phases. Unfortunately, many of the software engineering techniques and tools used for conventional software are of little use in the development of knowledge-based systems. Therefore, research at Langley is focused on developing a set of guidelines, methods, and prototype validation tools for building highly reliable, knowledge-based systems. The use of a comprehensive methodology for building highly reliable, knowledge-based systems should significantly decrease the time needed for testing and simulation. A proven record of delivering reliable systems at the beginning of the highly visible testing and simulation phases is crucial to the acceptance of knowledge-based systems in critical applications.

Johnson, Sally C.↗

Validation Testing and Statistical Analysis of the Rotary Tumbler Fabric Abrasion Method

The Artemis space suit glove environmental protection garment (EPG) will be the first line of protection used to shield the crewmember’s hands from the environments encountered during extravehicular activity (EVA). As the Artemis missions will include more extreme environments than those experienced on the International Space Station, development, verification, and validation of gloves requires the development of new test methods. A previous paper focused on the development of a test procedure to characterize lunar EVA glove fabrics using ASTM standardized test methods and the design and validation of a new standardized test procedure for comparing abrasion resistance between fabrics using a dust and rock filled rotary tumbler. Preliminary results of testing were presented in that paper. This paper reports on the validation testing and statistical analysis of the newly developed tumbler abrasion test method.

Robert J Jones↗

Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a fall 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (approximately 0.2 degree) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformation predictions to be measured were on the order of +/- 0.030 inches (+/- 0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. The most troublesome limitation was the inability to send personnel into the chamber to perform the measurements during the test due to vacuum and the temperature extremes. The photogrammetry (PG) system was chosen to perform the measurements since it is a non- contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The measurements met the desired requirements, for the metal structures enabling the desired distortions to be measured resolving deformations an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

Hill, Michael D.↗

Spatially Resolved Raman Spectroscopy of Thin Carbon Interphase in SiC Ceramic Matrix Composites

A dedicated analysis method is presented to extract the Raman spectrum of an interphase layer thinner than the laser spot size. We focused on spatial correlations between the contrast of optical micrographs and Raman hyperspectral data to predict the constituents of the mixed spectra measured near the interphase. By employing a mapping step size of 0.1 μm, the Raman spectrum of approximately 0.3-μm-thick carbon interphase in a SiC fiber-reinforced SiC matrix composite was extracted from data acquired with a theoretical spot size of about 0.7 μm. Notably, conventional chemometrics procedures were unable to isolate the interphase signal, instead producing a spectrum representing a mixture of interphase and matrix. This study used another composite with approximately 0.9-μm-thick interphase to validate the analysis method, enabling direct measurement of the interphase spectrum. The proposed Raman analysis method has advantages in specimen volume and turnaround time compared to traditional characterization methods, such as transmission electron microscopy. In conclusion, this study also evaluates the applicability of the analysis method to different composite materials and identifies key requirements of the measurements, including the ratio of interphase thickness to spot size and the homogeneity of the surrounding matrix.

ceramic matrix composite↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT

Background: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Methods: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of {sup 99m}Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Results: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). Conclusions: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developmental Testing of Habitability and Human Factors Tools and Methods During Neemo 15

Currently, no established methods exist to collect real-time human factors and habitability data while crewmembers are living aboard the International Space Station (ISS), traveling aboard other space vehicles, or living in remote habitats. Currently, human factors and habitability data regarding space vehicles and habitats are acquired at the end of missions during postflight crew debriefs. These debriefs occur weeks or often longer after events have occurred, which forces a significant reliance on incomplete human memory, which is imperfect. Without a means to collect real-time data, small issues may have a cumulative effect and continue to cause crew frustration and inefficiencies. Without timely and appropriate reporting methodologies, issues may be repeated or lost. TOOL DEVELOPMENT AND EVALUATION: As part of a directed research project (DRP) aiming to develop and validate tools and methods for collecting near real-time human factors and habitability data, a preliminary set of tools and methods was developed. These tools and methods were evaluated during the NASA Extreme Environments Mission Operations (NEEMO) 15 mission in October 2011. Two versions of a software tool were used to collect observational data from NEEMO crewmembers that also used targeted strategies for using video cameras to collect observations. Space habitability observation reporting tool (SHORT) was created based on a tool previously developed by NASA to capture human factors and habitability issues during spaceflight. SHORT uses a web-based interface that allows users to enter a text description of any observations they wish to report and assign a priority level if changes are needed. In addition to the web-based format, a mobile Apple (iOS) format was implemented, referred to as iSHORT. iSHORT allows users to provide text, audio, photograph, and video data to report observations. iSHORT can be deployed on an iPod Touch, iPhone, or iPad; for NEEMO 15, the app was provided on an iPad2.

Thaxton, S. S.↗

Progress Towards a Cartesian Cut-Cell Method for Viscous Compressible Flow

We present preliminary development of an approach for simulating high Reynolds number steady compressible flow in two space dimensions using a Cartesian cut-cell finite volume method. We consider both laminar and turbulent flow with both low and high cell Reynolds numbers near the wall. The approach solves the full Navier-Stokes equations in all cells, and uses a wall model to address the resolution requirements near boundaries and to mitigate mesh irregularities in cut cells. We present a quadratic wall model for low cell Reynolds numbers. At high cell Reynolds numbers, the quadratic is replaced with a newly developed analytic wall model stemming from solution of a limiting form of the Spalart-Allmaras turbulence model which features a forward evaluation for flow velocity and exactly matches characteristics of the SA turbulence model in the field. We develop multigrid operators which attain convergence rates similar to inviscid multigrid. Investigations focus on preliminary verification and validation of the method. Flows over flat plates and compressible airfoils show good agreement with both theoretical results and experimental data. Mesh convergence studies on sub- and transonic airfoil flows show convergence of surface pressures with wall spacings as large as approx.0.1% chord. With the current analytic wall model, one or two additional refinements near the wall are required to obtain mesh converged values of skin friction.

Berger, Marsha↗

Hydrogen trapping and the interaction of hydrogen with metals

A method has been developed for the determination of trapped hydrogen in metal alloys, involving the determination of mobile hydrogen using the electrochemical method and the determination of total hydrogen with the fusion method, the difference in hydrogen concentrations being due to trapped hydrogen. It has been found that hydrogen enters body-centered cubic structures through the grain bodies rather than through the grain boundaries. Hydrogen also diffuses much more rapidly in body-centered cubic structures on charging than in face-centered cubic structures, the hydrogen distribution being more uniform in nature. The energy necessary to cause hydrogen embrittlement is postulated to arise from the changes in crystal lattice energies brought about through interaction of hydrogen with atoms in the metal lattice. The total energy change is more negative for body-centered cubic structures, believed to be the cause of a greater tendency toward hydrogen embrittlement. Finally, the agreement of hydrogen concentrations obtained at 25 C by the electrochemical method with those obtained by the fusion method are taken as a strong indication of the power and validity of the electrochemical method.

Danford, Merlin D.↗