Search NASA⌕ Search

SEARCH · Search NASA

Results for “Work Domain Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,230 records · Page 69

TH-C-204-01: Vision for Medical Physics and Status of Current Initiatives

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-02: Improving Manuscript Quality Via Structured Reviews, Enhanced Scientific Category Taxonomy, and Outreach

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-03: Writing Good Scientific Papers and Responding to Critiques

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Laboratory-Scale Coal-Derived Graphene Process (Final Report)

The Energy & Environmental Research Center (EERC) conducted a laboratory-scale coal-derived graphene (CDG) project focused on developing a technological process for making graphene from four U.S. domestic coal or coal wastes, including lignite from North Dakota, subbituminous coal from Wyoming, bituminous coal from Utah, and anthracite from Pennsylvania. The project was divided into two performance or budget periods (BPs), with BP1 comprising the up-front laboratory experiments to make graphene materials from coal beginning on May 1, 2020, to April 30, 2022. BP2 was conducted from May 1, 2022, to April 30, 2023, and was focused on analyzing the CDG process economic feasibility and the technical gaps for technological scale-up and commercialization. During this project, a few different coal-derived high-value products have been demonstrated, including graphite, graphene oxide (GO), reduced graphene oxide (rGO), and graphene quantum dots (GQDs). A new graphite microstructure was discovered and named “croissant graphite” because of the exterior morphological and textural resemblance to croissant food items sold in commercial groceries stores. The new graphite structure and the associated preparation from coal or coal waste feedstocks has been the subject of a U.S. patent application. The systematic experimental processes involving coal cleaning, upgrading, and conversion to high-value carbon products culminated into a developed upgraded coal-to-products (UCP) technology that is being pursued for potential fast-track commercialization, if funding is available. It is envisioned that commercialization of the UCP technology would increase consumption of U.S. domestic coals or coal wastes to make environmentally sustainable high-value products for the electronics industry, high-energy-storage applications, and clean energy technologies such as electric vehicle (EV) lithium-ion batteries (LIBs), for which graphite has become a critical mineral commodity. Croissant graphite microstructures, when observed by field emission scanning electron microscopy (FESEM), display wavy surface morphology and often grow from a base that is made of graphitized particles with honeycomb-like layers, which are believed to be graphene layers. While more studies are needed to fully ascertain the mechanisms of the croissant graphite microstructure formation, it is postulated that their growth may begin from curling of the graphene sheets into ribbon-like structures, and continuous growth and densification of the ribbon-like structures forms croissant microstructures. Additional studies are ongoing to evaluate the electrochemical performance of croissant graphite for LIB applications and to determine the experimental conditions necessary to tune on/off croissant formation so that it can be either optimized or suppressed depending on performance evaluation results. In addition to the discovery of croissant graphite, the graphitization process from the four coal ranks in general was successful. X-ray diffraction (XRD) analysis showed that the degree of graphitization (DoG) ranged from 12% to 80% in an early sample set, and further optimization on lignite coal produces a DoG of about 92%, which was spectacular to see as lignite is the lowest-rank coal. Thus, it is expected that the graphitization performance for higher-rank coals will be similar or better when optimized as well. The coal-derived graphite was used to make GO and rGO. Analytical characterization, e.g., by methods such as Raman spectroscopy, XRD, Fourier transform infrared (FTIR) spectroscopy and FESEM, showed that the sequence of converting the coal to graphite, exfoliating it to GO, and then chemically reducing the GO to rGO was successful. Although coal naturally contains aromatic compounds and some relatively small-sized condensed aromatic units, it does not contain graphene sheets. In the UCP process, the aromatic domains in the coals, particularly low-rank coals, are concentrated and condensed further into graphene sheets, which are ordered into a 3D stack during graphitization. The synthesized graphite is then unpacked by methods such as exfoliation to various graphene products. GQDs were synthesized from all four coal types, and their optical properties were demonstrated to be tunable by the coal precursor preprocessing treatments. In all four coal types, enhanced optical properties were observed for the produced GDQs with incremental improvements made to the coal precursors. GQDs produced from raw coal samples displayed lower ultraviolet–visible (UV–Vis) spectroscopy absorbance intensity compared to those obtained from cleaned and upgraded coal residues. The photoluminescence (PL) intensities also varied with pretreatment conditions and with the concentration of GQDs in aqueous solutions. GQDs obtained from anthracite show longer emission wavelengths and can be excited by visible light as opposed to GQDs derived from the other coal ranks. UV fluorescence 3D maps and spectra revealed that the emission wavelength at which the GQDs solutions display the highest intensity was slightly redshifted based on the coal precursor pretreatments. In low-rank coal (lignite and subbituminous) samples, two clusters were observed in the maps for GQDs, which may suggest that there are potentially two types of fluorophores in solution or two main size populations. The ability to tune the properties of GQDs based on processing methods can be exploited to make GQDs for various optical display or optoelectronics applications. The results also highlight the importance of removing coal-borne impurities to improve the quality of the coal precursor for preparation of graphene products. Coal and/or coal wastes preprocessing methods were developed and applied to clean and upgrade the coal precursors prior to graphitization and subsequent conversion to graphene products. The preprocessing methods involve high specific-gravity separations, mineral acid cleaning (no hydrofluoric acid), and subsequent upgrading by reducing the coal-borne heteroatom (nitrogen, sulfur, and oxygen) content using proprietary chemical agents. Analytical characterization revealed that the preprocessing steps were successful, with ash reductions that range from 38% to 80% and residual ash content that was below the 5 wt% initial target. Based on proximate and ultimate analysis, the heteroatom reduction reactions produced upgraded coal residues with the oxygen content reduced by 8% to 24%, with additional reductions in the nitrogen and sulfur contents. An initial assessment of the waste streams from the UCP process shows very small to negligible environmental impact due to CO 2 , NO x , and SO x because most process steps are performed under inert atmosphere with argon. Consequently, reactive oxygen environments that tend to create these species are avoided. The inorganic and potentially hazardous species are released into aqueous waste streams that are easy to handle for proper disposal. The liquid waste streams were found to contain low-level concentrations of rare-earth elements (REEs), which could be concentrated and recovered as value-added by-products. Additionally, the volatile and gaseous fractions from carbonization and heat treatment contain useful organic compounds that can also be recovered as potential valuable by-products. Thus, the UCP technology is considered an environmentally sustainable and promising emerging technology for making high-value products from coal and coal wastes, with potential additional value-added by-products. Analysis of potential markets for the coal-derived carbon products shows a strong demand in both niche market sectors and across a wide variety of other industrial sectors. Graphite is currently considered a critical mineral commodity that has a large and growing demand in the LIB industry for EV applications. Based on data from Fortune Business Insights (2022) and Marketwatch (2023) reports, the average global graphite market is projected to reach about 33 billion by 2028, growing at a compound annual growth rate (CAGR) of about 7%, with much of this growth expected to be in the LIB industry. GO and rGO have strong market potentials in various application areas, such as coatings for anticorrosion, anti-icing, and antimicrobial protection, thermal barriers, wear resistance, sensors, additive manufacturing such as 3D inks, and others. GQDs are the emerging key player in the bioimaging, photovoltaics, and light-emitting diodes (LEDs) applications, with the potential to replace traditional semiconductor quantum dots (SQDs), which are based on metallic systems that are more toxic and more expensive. Biomedical applications of GQDs are becoming more attractive because of low to no toxicity and extremely low cost compared to SQDs. The major challenges for scale-up and commercialization of coal-derived carbon products such as graphene vary from the inherent attributes of graphene itself to reluctance to accept graphene in new manufacturing processes because of the uncertainty of the unknown. The 2D nature of graphene materials with a thickness of one atom presents significant challenges to proper handling/processing, and process scale-up becomes difficult because it requires high-end, expensive equipment, even for routine handling and analysis for quality assurance and control. Pristine graphene can also be extremely difficult to work into other matrices, thus hindering downstream processibility, especially at large scale. Currently, the cost of graphene and graphene products is still high and presents an economic risk that tends to slow down investment in scaling up emerging technologies. The lack of a standard for graphene materials for quality assurance and quality control poses a great challenge not only for the markets but also for commercialization efforts. A first-look economic feasibility analysis of the UCP technology provided valuable information that suggests the UCP process would be feasible, especially when it is scaled to a pilot scale and could be more competitive at the full scale. Graphitization was found to be the most energy-consuming and most capital-intensive step in the overall process. In small laboratory- and bench-scale experiments, labor is a significant contributor to the total process costs. Although these energy, capital, and labor constraints contribute to a higher selling price for the product, a preliminary economic model suggests that the process would be feasible at large scale when the process is fully integrated, optimized, and automated.

01 COAL, LIGNITE, AND PEAT↗

Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers

This is the final scientific report for the award DE-FE0023305, entitled “Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers.” The work has been divided into six tasks. In Task 2, we characterized rock properties, which are important when developing a quantitative approach for understanding and predicting geomechanical effects on large-scale CO 2 injection and long-term storage in the subsurface. Rock properties of interest for this characterization include porosity, permeability, elastic constants, strength, and heat capacity. We measured rock properties for three different rock types: concrete, sandstone and shale. These properties were obtained from the acoustic measurement, permeability and porosity measurement, Brazilian test, the uniaxial compressive test, and heat capacity measurement. Then, using the Brazilian technique to fracture samples, we measured their permeability under brine injection for varying effective stresses, followed by similar measurements of permeability under sc-CO 2 injection. Permeability to brine and sc-CO 2 decreased as the effective stress increased. The apparent permeability to sc-CO 2 was an order of magnitude less than that for brine, a consequence of CO 2 being the non-wetting fluid. In Task 3, we developed understandings and correlations for CO 2 injection pressure induced fracturing. We initially fractured four eight inch cubes of concrete with brine to establish a standard test procedure. Then, additional concrete samples were fractured using brine. Confining stresses were exerted on the samples and brine was injected at a constant rate into a borehole that was previously drilled into the concrete cube. The borehole pressure was measured and fracture initiation was identified as a peak in the pressure profile. That was followed by fracture propagation, which was identified as a plateau in the pressure profile, and finally the fracture reached the sample surface. The sample surfaces were photographed before and after fracturing, which enabled determination of where the fracture reached the sample surface. Afterwards, aqueous food dye solution was injected into the fractured concrete samples to color the fracture planes. The borehole was filled with food dye solution in advance, a gas pulse was transmitted to the borehole, and the borehole was then shut in to allow the food dye to be driven into existing fractures. Then, the concrete samples were broken down by high-pressure gas injection to reveal the geometry and morphology of the hydraulic fractures. In addition, acoustic measurements were conducted on multiple locations on each face of the concrete samples before and after injection for comparison. This comparison was used to confirm changes in the internal structure of the concrete sample, namely the formation of fractures. There were six concrete samples fractured with brine. Afterwards, concrete samples were fracture using sc-CO 2 . The main change in experimental procedure was the inclusion of temperature control, since in the field, we mostly encounter temperature and pressure conditions above the supercritical point of CO 2 . The concrete samples were pre-heated in an oven to elevate their temperature, and thermal tape was used to heat the CO 2 to a temperature above its supercritical temperature. Two concrete samples were fractured using liquid CO 2 , four concrete samples were fractured using gaseous CO 2 , and twenty two concrete samples were fractured using sc-CO 2 . For the concrete samples fractured using sc-CO 2 , three had pre-existing hydraulic fractures on the surface near the wellbore, and two were water saturated (as opposed to containing only air). Two concrete samples were composite samples, with a high permeability ball in the center, in order to represent CO 2 injection into a high permeability zone surrounded by a low permeability sealing formation. Later, we fractured five shale samples, obtained from the Niobrara shale outcrop, with sc-CO 2 . The injection rate was constant, confining stresses were applied, the shale samples were pre-heated in an oven to the desired temperature, and the sample was then fractured. An analysis of the failure type was done for many of the concrete samples, based on the predicted break down pressure for tensile and shear failure, and it was found that most samples fractured due to shear failure. Also, the presence of induced fractures has little to no effect on the fracture initiation pressure, but significantly changes the fracture morphology. The CO 2 fracturing in water saturated samples behaved much similar to brine induced fracturing. There was a significant difference of breakdown pressure for injection of CO 2 and brine, where the breakdown pressure for CO 2 induced fracturing is generally around the minimum horizontal stress and that for brine is much higher. Finally, the fracture orientation for most samples with large confining stress differential was perpendicular to the minimum horizontal stress. When the stress differential, especially the difference between the two directions with the smallest stresses was small, the fracture orientation was determined not only by the minimum stress direction, but also the magnitude of the confining stress, the tensile strength of the rock, and the breakdown pressure. In Task 4, we modified our coupled flow-geomechanical models to model fracture growth and propagation in storage formations and caprocks. These flow-geomechanical models are TOUGH2-CSM and TOUGH2-FLAC. The TOUGH2-CSM fluid and heat flow formulation is based on the TOUGH2 formulation of mass and energy conservation equations that govern fluid and heat flow in general multiphase, multicomponent, multi-porosity systems. The TOUGH2-CSM simplified geomechanical formulation is based on the linear theory of elasticity applied to multi-porosity non-isothermal (thermo-multi-poroelastic) media. We previously derived, from the fundamental relations of the linear theory of elasticity, an equation relating mean stress, pore pressures, temperatures, and body force (the Mean Stress equation) that we added to the TOUGH2-CSM fluid and heat flow equations. We extended the TOUGH2-CSM simplified geomechanical formulation to calculate the entire stress tensor by deriving equations for stress tensor components from derivatives of the Cartesian thermo-multi-poroelastic Navier equation components. In addition, we derived equations for stress tensor components in rz-coordinates. We solved these geomechanical equations using the integral finite difference method. This method utilizes momentum fluxes obtained by “factoring” a divergence operator out of each geomechanical equation. In Task 5, we did a literature survey to determine suitable correlations for fracture initiation, growth, and propagation. After surveying numerous papers, we modified TOUGH2-CSM to model stress dependent fracture initiation and growth using the Mohr-Coulomb criterion for shear failure in faults and caprock and the condition of negative minimum effective stress for tensile failure. Tensile failure results in a fracture whose width depends on the difference between fracture pressure and minimum stress and whose propagation is based on the difference between the stress intensity factor at the fracture tip and the rock toughness. The TOUGH-FLAC model is based on the FLAC3D ubiquitous joint model, extended for the modeling of permeability changes induced by changes in effective normal stress across fractures as well permeability changes caused by shearing along fractures. In Task 6, we validated our coupled flow-geomechanical models using analytical solutions and problems from the literature. We validated the TOUGH2-CSM modifications using analytical solutions to the displacement from a uniform load on a semi-infinite elastic medium and the two-dimensional Mandel-Cryer effect. Those were followed by a sample problem to test our stress tensor calculations, which was for injection into a single-phase reservoir with constant properties. Comparisons of our simulator to published results were done on for the depletion of a single-phase reservoir with stress dependent porosity, two examples from the In Salah gas project, an axisymmetric baserock–reservoir–caprock system with a normal faulting stress regime that had thermally induced shear stresses, simulations of CO 2 leakage through caprock in a two-dimensional reservoir in Cartesian coordinates, and predictions of caprock failure from CO 2 injection into an axisymmetric reservoir. Finally, we simulated CO 2 injection pressure-induced fracturing from one of our laboratory studies, Sample 39, and obtained a fracture profile. We also validated the TOUGH2-FLAC model for fluid driven fracture growth against solutions based on the KGD model and a case with an inclined fracture that was loaded from the boundaries to achieve wing-crack propagation. The strain softening tensile behavior and softening of modulus considering a simple damage approach was verified by a simulation representing hydraulic fracturing stress measurement around a vertical well. Finally, the model was validated against deep fracture zone opening and surface uplift at In Salah with inverses analysis used to improve the match of simulation with field data. In Task 7, we developed a scheme based on inverse modeling that can be used to identify caprock leakage. Injection of fluid into a reservoir results in a time varying pressure profile that depends on the properties of the rock and the fluid. The presence of significant caprock leakage would effect this pressure profile and we used inverse modeling, namely the Levenberg-Marquardt method, to determine the leakage location from the pressure profile. A two-dimensional and a three-dimensional example based on published data were presented. The published simulation was run and its results were considered as “field” data. In the two-dimensional example, a simulation of CO 2 injection into a two-dimensional aquifer-caprock system, the caprock had a vertical fault through which leakage could occur. The location of this leakage was obtained from our inverse modeling scheme. In the three-dimensional example, the simulation domain had four geological layers, one of which was the injection zone that contained a horizontal injection well. We simulated fractures as high permeability gridblocks, introduced a fracture that spanned the caprock depth, and ran a simulation to obtain “field” data. Then, using our inverse modeling scheme, we obtained the location of that fracture.

58 GEOSCIENCES↗