Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser

Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies↗

Doppler Spectrometry for Ultrafast Temporal Mapping of Density Dynamics in Laser-Induced Plasmas

We present high resolution measurements of the ultrafast temporal dynamics of the critical surface in moderately overdense, hot plasma by using two-color, pump-probe Doppler spectrometry. Our measurements clearly capture the initial inward motion of the plasma inside the critical surface of the pump laser which is followed by outward expansion. The measured instantaneous velocity and acceleration profiles are very well reproduced by a hybrid simulation that uses a 1D electromagnetic particle-in-cell simulation for the initial evolution and a hydrodynamics simulation for the later times. The combination of high temporal resolution and dynamic range in our measurements clearly provides quantitative unraveling of the dynamics in this important region, enabling this as a powerful technique to obtain ultrafast snapshots of plasma density and temperature profiles for providing benchmarks for simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficacy and Delivery of Novel FAST Agents for Coronaviruses

We proposed to test and develop advanced delivery for novel agents from our collaborators Facile Accelerated Specific Therapeutics (FAST) platform to reduce coronavirus replication. Sachi Bioworks Inc., Prof. Anushree Chatterjee, and Prof. Prashant Nagpal at the University of Colorado Boulder have developed a bioinformatics and synthesis pipeline to produce sequence specific theranostic agents (agents that can be therapies and/or diagnostics) that are inherently transported into the cytoplasm of mammalian host cells and sequence-specifically interfere in nucleic acid replication. The agent comprises a small nanoparticle (2-5 nm) chosen for ideal cellular transport and/or imaging conjugated to a short, synthetic DNA analog oligomer designed for binding to one or more target viral sequences. The sequence specific binding of the FAST agent to its target prevents nucleic acid replication due to its high affinity binding. While the small nanoparticle facilitates delivery in vitro, we plan to package the FAST agents into a larger nanoparticle (80-300 nm) for future in vivo delivery applications. Our team at Sandia has expertise encapsulating biomolecules including protein, DNA, and RNA into solid lipid nanoparticles (LNP) and lipid coated mesoporous silica nanoparticles (LC-MSN) and shown successful delivery in mouse models to multiple tissues. Our team focused on formulation parameters for FAST agents into lipid nanoparticles (LNP) and lipid coated mesoporous silica nanoparticles (LC-MSN) for enhanced delivery and/or efficacy and in vivo translation. We used lipid formulas that have been shown in literature to facility in vitro and more importantly, in vivo delivery. In our work discussed below, we successfully demonstrate loading and release of FAST agents on silica core and stable LC-MSN in a reasonable size range for in vivo testing.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling the Variability of the BL Lacertae Object PKS 2155-304

The bright X-ray-selected BL Lacertae object PKS 2155-304 has been the target of two intense multi-wavelength campaigns in 1991 November and in 1994 May. Although the spectral energy distributions at both epochs were quite similar, the source exhibited two very distinct variability patterns that cannot be easily reconciled with homogeneous one-zone C7 jet models. During the first epoch the variability was almost achromatic in amplitude, with a time lag between X-rays and ultraviolet radiation (UV) of approximately three hours, while during the second epoch the variability amplitude increased as a function of wavelength with the EUV flare peaking approximately one day after the X-ray flare. We model the source using a time-dependent inhomogeneous accelerating jet model. We reproduce the general characteristics of the different variability signatures by assuming that plasma disturbances with different physical properties propagate downstream in an underlying jet characterized by the same set of physical parameters at both epochs. A time delay of approximately one day between the hardening of the UV spectral index and the UV flux present at both epochs is modeled with stochastic fluctuations in the particle acceleration manifested through small variations of the maximum energy of the injected electrons. We predict that similar time delays will be present in future observations even in the absence of strong variability event. We stress the importance of observations at neighboring frequencies as a diagnostic tool for the structure of the quiescent jet in blazars especially in the seemingly dull case in which strong variability is absent.

Georganopuolos, Markos↗

Development of an Extreme Environment Materials Research Facility at Princeton

The need for a fundamental understanding of material response to a neutron and/or high heat flux environment can yield development of improved materials and operations with existing materials. Such understanding has numerous applications in fields such as nuclear power (for the current fleet and future fission and fusion reactors), aerospace, and other research fields (e.g., high-intensity proton accelerator facilities for high energy physics research). A proposal has been advanced to develop a facility for testing various materials under extreme heat and neutron exposure conditions at Princeton. The Extreme Environment Materials Research Facility comprises an environmentally controlled chamber (48 m^3) capable of high vacuum conditions, with extreme flux beams and probe beams accessing a central, large volume target. The facility will have the capability to expose large surface areas (1 m^2) to 14 MeV neutrons at a fluence in excess of 10^13 n/s. Depending on the operating mode. Additionally beam line power on the order of 15-75 MW/m2 for durations of 1-15 seconds are planned... The multi-second duration of exposure can be repeated every 2-10 minutes for periods of 10-12 hours. The facility will be housed in the test cell that held the Tokamak Fusion Test Reactor (TFTR), which has the desired radiation and safety controls as well as the necessary loading and assembly infrastructure. The facility will allow testing of various materials to their physical limit of thermal endurance and allow for exploring the interplay between radiation-induced embrittlement, swelling and deformation of materials, and the fatigue and fracturing that occur in response to thermal shocks. The combination of high neutron energies and intense fluences will enable accelerated time scale studies. The results will make contributions for refining predictive failure modes (modeling) in extreme environments, as well as providing a technical platform for the development of new alloys, new materials, and the investigation of repair mechanisms. Effects on materials will be analyzed with in situ beam probes and instrumentation as the target is exposed to radiation, thermal fluxes and other stresses. Photon and monochromatic neutron fluxes, produced using a variable-energy (4-45 MeV) electron linac and the highly asymmetric electron-positron collisions technique used in high-energy physics research, can provide non-destructive, deep-penetrating structural analysis of materials while they are undergoing testing. The same beam lines will also be able to generate neutrons from photonuclear interactions using existing Bremsstrahlung and positrons on target quasi-monochromatic gamma rays. Other diagnostics will include infrared cameras, residual gas analyzer (RGA), and thermocouples; additional diagnostic capability will be added.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matter in Extreme Conditions Instrument - Conceptual Design Report

The SLAC National Accelerator Laboratory (SLAC), in collaboration with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) research facility. The FEL has already met its performance goals in the wavelength range 1.5 nm - 0.15 nm. This facility, the Linac Coherent Light Source (LCLS), utilizes the SLAC 2-Mile Linear Accelerator (linac) and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac is used as the source of electrons for the LCLS. The high energy electrons are transported across the SLAC Research Yard, into a tunnel which houses a long undulator. In passing through the undulator, the electrons are bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength is tunable from 1.5 nm to 0.15 nm. The LCLS includes two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing an X-ray instrument in order to exploit the unique scientific capability of LCLS by creating extreme conditions and study the behavior of plasma under those controlled conditions. This instrument will address the Office of Science, Fusion Energy Sciences, mission objective related to study of Plasma and Warm Dense Matter as described in the report titled LCLS, the First Experiments, prepared by the LCLS Scientific Advisory Committee (SAC) in September 2000. The technical objective of the LCLS Matter in Extreme Conditions (MEC) Instrument project is to design, build, and install at the LCLS an X-ray instrument that will complement the initial instrument suite included in the LCLS construction and the LUSI Major Item of Equipment (MIE) Instruments. As the science programs advance and new technological challenges appear, instrumentation must be developed and ready to conquer these new opportunities. The MEC concept has been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the MEC instrument has been identified as meeting one of the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community. The primary purpose of the MEC instrument is to create High Energy Density (HED) matter and measure its physical properties. There are three primary elements of the MEC instrument: (A) Optical laser drivers that will create HED states by irradiation in several ways and provide diagnostics capability; (B) The LCLS x-ray free electron laser, which will provide the unique capability to create, probe and selectively pump HED states; and, (C) A suite of diagnostic devices required to observe the evolution of the HED state. These elements when combined in the MEC instrument meet the 'Mission Need' as defined in CD-0. For the purposes of the description we separate the types of experiments to be performed into three categories: (1) High pressure: Here we are interested in the generation of high pressure using the optical lasers to irradiate a surface that ablates and drives a pressure wave into a sample, similar to a piston. The pressures that can be reached exceed 1 Mbar and the properties of interest are for example, the reflectivity, conductivity, opacity as well as the changes driven by the pressure wave on, e.g., condensed matter structure. These phenomena will be studied by means of diffraction measurements, measurements of the pressure wave characteristics, in situ probing by x-ray scattering of various types all time resolved. The necessary diagnostics are discussed.

43 PARTICLE ACCELERATORS↗

Generation of gamma radiation by a subterawatt ultrashort laser pulse: optimisation of preplasma and pulse duration

We report an experimental and numerical study of the acceleration of electrons in a plasma interacting with a subterawatt laser pulse (intensity of ∼3 × 10{sup 18} W cm{sup −2} at a pulse duration of 50 fs). A preplasma layer on the surface of a molybdenum target is formed by an additional laser pulse with a duration of 8 ns and an intensity of ∼2 × 10{sup 12} W cm{sup −2}. It is shown that an increase in the laser pulse duration to 1700 fs at a constant energy (and a proportional decrease in intensity) leads to an increase in the yield of bremsstrahlung γ-radiation by more than an order of magnitude when the nanosecond pulse is ahead of the femtosecond one by 15 − 25 ns. Interferometry data and results of diagnostics of optical and γ-radiation of a plasma demonstrate that the collisional ionisation of atoms by electrons oscillating in the field of such a laser pulse plays an essential role in the formation of electron density profile. The sensitivity of the described effect to the level of amplified spontaneous emission is determined, despite the nanosecond pulse impact. Numerical simulations show that at a large pulse duration, the acceleration of electrons is stipulated by the beaking of plasma waves excited during stimulated Raman scattering of laser radiation. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulations used for a validity check on the laser induced photo-detachment diagnostic method in electronegative plasmas

Laser photo-detachment is used as a method to measure or determine the negative ion density and temperature in electronegative plasmas. In essence, the method consists of producing an electropositive channel (negative ion free region) via pulsed laser photo-detachment within an electronegative plasma bulk. Electrostatic probes placed in this channel measure the change in the electron density. A second pulse might be used to track the negative ion recovery. From this, the negative ion density and temperature can be determined. We study the formation and relaxation of the electropositive channel via a two-dimensional Particle-In-Cell/Mote Carlo collision model. The simulation is mainly carried out in a Hydrogen plasma with an electronegativity of α = 1, with a parametric study for α up to 20. The temporal and spatial evolution of the plasma potential and the electron densities shows the formation of a double layer (DL) confining the photo-detached electrons within the electropositive channel. This DL evolves into two fronts that move in the opposite directions inside and outside of the laser spot region. As a consequence, within the laser spot region, the background and photo-detached electron energy distribution function relaxes/thermalizes via collisionless effects such as Fermi acceleration and Landau damping. Moreover, the simulations show that collisional effects and the DL electric field strength might play a non-negligible role in the negative ion recovery within the laser spot region, leading to a two-temperature negative ion distribution. The latter result might have important effects in the determination of the negative ion density and temperature from laser photo detachment diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delayed Gamma-ray Spectroscopy for Safeguards Applications

The delayed gamma-ray assay technique utilizes an external neutron source (D-D, D-T, or electron accelerator-driven), and high-resolution gamma-ray spectrometers to perform characterization of SNM materials behind shielding and in complex configurations such as a nuclear fuel assembly. High-energy delayed gamma-rays (2.5 MeV and above) observed following the active interrogation, provide a signature for identification of specific fissionable isotopes in a mixed sample, and determine their relative content. Potential safeguards applications of this method are: 1) characterization of fresh and spent nuclear fuel assemblies in wet or dry storage; 2) analysis of uranium enrichment in shielded or non-characterized containers or in the presence of a strong radioactive background and plutonium contamination; 3) characterization of bulk and waste and product streams at SNM processing plants. Extended applications can include warhead confirmation and warhead dismantlement confirmation in the arms control area, as well as SNM diagnostics for the emergency response needs. In FY16 and prior years, the project has demonstrated the delayed gamma-ray measurement technique as a robust SNM assay concept. A series of empirical and modeling studies were conducted to characterize its response sensitivity, develop analysis methodologies, and analyze applications. Extensive experimental tests involving weapons-grade Pu, HEU and depleted uranium samples were completed at the Idaho Accelerator Center and LLNL Dome facilities for various interrogation time regimes and effects of the neutron source parameters. A dedicated delayed gamma-ray response modeling technique was developed and its elements were benchmarked in representative experimental studies, including highresolution gamma-ray measurements of spent fuel at the CLAB facility in Sweden. The objective of the R&D effort in FY17 is to experimentally demonstrate the feasibility of the delayed gamma-ray interrogation of shielded SNM samples with portable neutron sources suitable for field applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

First beam measurements on the vessel for extraction and source plasma analyses (VESPA) at the Rutherford Appleton Laboratory (RAL)

In order to facilitate the testing of advanced H{sup −} ion sources for the ISIS and Front End Test Stand (FETS) facilities at the Rutherford Appleton Laboratory (RAL), a Vessel for Extraction and Source Plasma Analyses (VESPA) has been constructed. This will perform the first detailed plasma measurements on the ISIS Penning-type H{sup −} ion source using emission spectroscopic techniques. In addition, the 30-year-old extraction optics are re-designed from the ground up in order to fully transport the beam. Using multiple beam and plasma diagnostics devices, the ultimate aim is improve H{sup −} production efficiency and subsequent transport for either long-term ISIS user operations or high power FETS requirements. The VESPA will also accommodate and test a new scaled-up Penning H{sup −} source design. This paper details the VESPA design, construction and commissioning, as well as initial beam and spectroscopy results.

43 PARTICLE ACCELERATORS↗

NSTXU Diagnostic Disruption Dynamic Loading Represented by Response Spectra

This article presents the results of transient dynamic simulations of loads due to disruption eddy currents on the NSTXU vacuum vessel. Dynamic loading at diagnostic mounting locations is expressed as response spectra derived from the time history results of the dynamic structural simulations of a variety of disruption scenarios. The disruption simulations draw on a history of the project assessments of worst case disruptions for specific components. Major efforts to assess disruption loading have included the vacuum vessel which is the major structural support for the machine, as well as the passive plates (PPs), high harmonic fast wave (HHFW) antenna, and centerstack casing. Each one of these efforts included transient electromagnetic simulations producing time-dependent eddy current Lorentz loads (and in some cases halo loads) which then were applied to time-dependent structural dynamic analyses intended to obtain the proper dynamic amplification factors. In some instances, the EM model and structural model were identical allowing direct transfer of EM forces to the structural model. In other cases, the EM and structural model were not identical and the vector potential (VP) transfer method was used. The results files from these analyses were available (or re-run) to post process in ANSYS Classic time history postprocessor. In conclusion, the ANSYS command is used to create response spectra from time history data at desired points on the vessel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizations and Applications of the Insertion Device of the SPring-8 Diagnostics Beamline II

An insertion device (ID05) of the SPring-8 diagnostics beamline II (BL05SS) was characterized from the aspects of both the magnetic field performance and the spectral performance as a high K wiggler, which was confirmed to have the field performance with the rms phase error less than 2 degree. Meanwhile, the spectral performance of ID05 as an undulator with small K was also investigated by the energy spectrum measurements. The rms phase error less than 2degree leads us to apply the wiggler radiation on the higher harmonics to the beam diagnostics. We successfully demonstrated an application to the energy-spread diagnostics of electron beam using the 19th harmonics.

43 PARTICLE ACCELERATORS↗

Non-invasive low charge electron beam time-of-arrival diagnostic using a plasmonics-enhanced photoconductive antenna

The use of a plasmonics-enhanced photoconductive antenna (PCA) optically gated by a near infrared (NIR) pulse enables non-invasive time-of-arrival measurements of a low charge electron beam with respect to the NIR reference, achieving picosecond resolution. The measured signal values show the expected scaling with the beam charge and distance from PCA to the beam axis, as the PCA samples the electric field of the passing electron beam. We operate the device with an NIR spot size much larger than the PCA active-area, resulting in a very simple optical setup and alignment procedure, making the plasmonics-enhanced PCA a preferred alternative to more complex timing diagnostics for applications requiring non-invasive picosecond or sub-picosecond timestamping.

43 PARTICLE ACCELERATORS↗

RHIC electron lens test bench diagnostics

An Electron Lens (E-Lens) system will be installed in RHIC to increase luminosity by counteracting the head-on beam-beam interaction. The proton beam collisions at the RHIC experimental locations will introduce a tune spread due to a difference of tune shifts between small and large amplitude particles. A low energy electron beam will be used to improve luminosity and lifetime of the colliding beams by reducing the betatron tune shift and spread. In preparation for the Electron Lens installation next year, a test bench facility will be used to gain experience with many sub-systems. This paper will discuss the diagnostics related to measuring the electron beam parameters.

43 PARTICLE ACCELERATORS↗

Double layer formation in a two-region electronegative plasma

The formation of a double layer (DL) in a two-dimensional (2D) electronegative plasma with a source (heating) section connected to a larger downstream section is described. A 2D particle-in-cell (PIC) code is used to exhibit the DL, which appears near the transition between the source and downstream chambers, over a range of pressures and electronegativities. Diagnostics of the PIC code allow the calculation of various plasma parameters, not easily measured in experiments, to be compared with an analytic theory. The theory consists of a collisionless one-dimensional model of a DL connected to 2D source and downstream global models. The conditions of positive and negative ion balance upstream and downstream, and the downstream energy balance determine the DL potential, electron temperatures, and other plasma parameters. A rescaled oxygen reaction set is used both for the simulation and for the analytic comparison. The PIC simulations exhibit a Maxwellian electron distribution in the source region at temperature T{sub h}, and a bi-Maxwellian distribution downstream, with a low energy population at temperature T{sub c}<T{sub h} and with a hotter tail also having temperature T{sub h}. At the upstream DL edge, an accelerated electron component is observed. Using these results in the model, a DL is found in reasonable agreement with that obtained in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗