Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Investigating the low-temperature impedance increase of lithium-ion cells.

Low-temperature performance loss is a significant barrier to commercialization of lithium-ion cells in hybrid electric vehicles. Increased impedance, especially at temperatures below 0 C, reduces the cell pulse power performance required for cold engine starts, quick acceleration, or regenerative braking. Here we detail electrochemical impedance spectroscopy data on binder- and carbon-free layered-oxide and spinel-oxide electrodes, obtained over the +30 to ?30 C temperature range, in coin cells containing a lithium-preloaded Li{sub 4/3}Ti{sub 5/3}O{sub 4} composite (LTOc) counter electrode and a LiPF{sub 6}-bearing ethylene carbonate/ethyl methyl carbonate electrolyte. For all electrodes studied, the impedance increased with decreasing cell temperature; the increases observed in the midfrequency arc dwarfed the increases in ohmic resistance and diffusional impedance. Our data suggest that the movement of lithium ions across the electrochemical interface on the active material may have been increasingly hindered at lower temperatures, especially below 0 C. Low-temperature performance may be improved by modifying the electrolyte-active material interface (for example, through electrolyte composition changes). Increasing surface area of active particles (for example, through nanoparticle use) can lower the initial electrode impedance and lead to lower cell impedances at -30 C.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modeling Two-Stage Bunch Compression With Wakefields: Macroscopic Properties And Microbunching Instability

In a two-stage compression and acceleration system, where each stage compresses a chirped bunch in a magnetic chicane, wakefields affect high-current bunches. The longitudinal wakes affect the macroscopic energy and current profiles of the compressed bunch and cause microbunching at short wavelengths. For macroscopic wavelengths, impedance formulas and tracking simulations show that the wakefields can be dominated by the resistive impedance of coherent edge radiation. For this case, we calculate the minimum initial bunch length that can be compressed without producing an upright tail in phase space and associated current spike. Formulas are also obtained for the jitter in the bunch arrival time downstream of the compressors that results from the bunch-to-bunch variation of current, energy, and chirp. Microbunching may occur at short wavelengths where the longitudinal space-charge wakes dominate or at longer wavelengths dominated by edge radiation. We model this range of wavelengths with frequency-dependent impedance before and after each stage of compression. The growth of current and energy modulations is described by analytic gain formulas that agree with simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microplasma source for optogalvanic spectroscopy of nanogram samples

The demand for analysis of smaller samples in isotopic ratio measurements of rare isotopes is continuously rising with the development of new applications, particularly in biomedicine. Interesting in this aspect are methods based on optogalvanic spectroscopy, which have been reported to facilitate both {sup 13}C-to-{sup 12}C and {sup 14}C-to-{sup 12}C ratio measurements with high sensitivity. These methods also facilitate analysis of very small samples, down to the microgram range, which makes them very competitive to other technologies, e.g., accelerator mass spectroscopy. However, there exists a demand for moving beyond the microgram range, especially from regenerative medicine, where samples consist of, e.g., DNA, and, hence, the total sample amount is extremely small. Making optogalvanic spectroscopy of carbon isotopes applicable to such small samples, requires miniaturization of the key component of the system, namely the plasma source, in which the sample is ionized before analysis. In this paper, a novel design of such a microplasma source based on a stripline split-ring resonator is presented and evaluated in a basic optogalvanic spectrometer. The investigations focus on the capability of the plasma source to measure the optogalvanic signal in general, and the effect of different system and device specific parameters on the amplitude and stability of the optogalvanic signal in particular. Different sources of noise and instabilities are identified, and methods of mitigating these issues are discussed. Finally, the ability of the cell to handle analysis of samples down to the nanogram range is investigated, pinpointing the great prospects of stripline split-ring resonators in optogalvanic spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of nuclear {gamma}-ray line emission in interactions of protons and {alpha} particles with N, O, Ne, and Si

{gamma}-ray production cross sections have been measured in proton irradiations of N, Ne, and Si and {alpha}-particle irradiations of N and Ne. In the same experiment we extracted also line shapes for strong {gamma}-ray lines of {sup 16}O produced in proton and {alpha}-particle irradiations of O. For the measurements gas targets were used for N, O, and Ne and a thick foil for Si. All targets were of natural isotopic composition. Beams in the energy range up to 26 MeV for protons and 39 MeV for {alpha} particles were delivered by the Institut de Physique Nucleaire-Orsay tandem accelerator. The {gamma} rays were detected with four high-purity Ge detectors in the angular range 30 deg. to 135 deg. We extracted 36 cross-section excitation functions for proton reactions and 14 for {alpha}-particle reactions. For the majority of the excitation functions no other data exist to our knowledge. Where comparison with existing data was possible, usually a very good agreement was found. It is shown that these data are very interesting for constraining nuclear reaction models. In particular, the agreement of cross section calculations in the nuclear reaction code talys with the measured data could be improved by adjusting the coupling schemes of collective levels in the target nuclei {sup 14}N, {sup 20,22}Ne, and {sup 28}Si. The importance of these results for the modeling of nuclear {gamma}-ray line emission in astrophysical sites is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic dipole excitations in nuclei: Elementary modes of nucleonic motion

The nucleus is one of the most multifaceted many-body systems in the Universe. It exhibits a multitude of responses depending on the way one ''probes'' it. With increasing technical advancements of beams at the various accelerators and of detection systems the nucleus has, over and over again, surprised us by expressing always new ways of ''organized'' structures and layers of complexity. Nuclear magnetism is one of those fascinating faces of the atomic nucleus discussed in the present review. We shall not just limit ourselves to presenting the by now large data set that has been obtained in the past two decades using various probes, electromagnetic and hadronic alike and that presents ample evidence for a low-lying orbital scissors mode around 3 MeV, albeit fragmented over an energy interval of the order of 1.5 MeV, and higher-lying spin-flip strength in the energy region 5-9 MeV in deformed nuclei nor to the presently discovered evidence for low-lying proton-neutron isovector quadrupole excitations in spherical nuclei. To the contrary, the experimental evidence is put in the perspectives of understanding the atomic nucleus and its various structures of well-organized modes of motion and thus enlarges the discussion to more general fermion and bosonic many-body systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The radioactive ion beam production systems for the SPIRAL2 project

The SPIRAL2 project, currently under construction at GANIL, will include an isotope separator on line based facility for the production and acceleration of radioactive ion beams. A superconducting linear accelerator will accelerate 5 mA deuterons up to 40 MeV and 1 mA heavy ions up to 14.5 MeV/u. These primary beams will be used to bombard both thick and thin targets. We are investigating three different techniques to produce the radioactive ion beams: (1) the neutron induced fission of uranium carbide, (2) the direct interaction of deuterons in a uranium carbide target, and (3) the interaction of a heavy ion beam with a target. All these production systems will be coupled to an ion source. Four kinds of ion sources are foreseen for the ionization of the radioactive atoms: an electron cyclotron resonance ion source, a surface ionization ion source, a forced electron beam induced arc discharge ion source, and a laser ion source depending on the characteristics of the desired radioactive ion beam in terms of intensity, efficiency, purity, etc. A presentation of the SPIRAL2 project and of the different production systems is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytical calculations of wake field generated by microwave pulses in a plasma filled waveguide for electron acceleration

Analytical expressions are obtained for the longitudinal field (wake field), density perturbation, and the potential behind microwave pulse propagating in a plasma filled rectangular waveguide with the pulse duration half of the electron plasma period. A feasibility study on wake field is carried out with rectangular pulse and its combination with Gaussian and triangular pulses under the effects of microwave pulse parameters and waveguide dimensions. It is inferred that the wake field in the waveguide cannot be attained when the length of rectangular microwave pulse is exactly equal to the plasma wavelength. A 1 ns short rectangular pulse with intensity of 250 kW/cm{sup 2} at the frequency of 5.03 GHz can excite the wake field of 1.0 MV/m in a waveguide with width of 6 cm and height of 4 cm. However, enhanced field is obtained when rectangular-triangular pulse (combination of rectangular and triangular pulses) is used. The field of wake gets weakened at higher microwave frequency and larger dimensions of the waveguide for other fixed parameters. However, a larger field is achieved when the pulse length of the microwave pulses is made shorter and/or intensity of the pulses is increased. A comparative study of the pulses shows that better results can be obtained with rectangular pulse (rectangular-Gaussian pulse: combination of rectangular and Gaussian pulses) if the microwave of shorter pulse duration (higher intensity) is available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Free (Reactionless) Torque Generation - Or Free Propulsion Concept

The basic principle in Newtonian Mechanics is based upon equal and opposite forces. Placing the vectors of velocity, acceleration, force and momentum of interacting objects along a single line satisfies the claim it is a linear or a 1-D concept. Classical Mechanics states that there are two main kinds of motion, linear and angular motion. Similarly placing the vectors of angular velocity, angular acceleration, torque and angular momentum along a line in the case of rotation in fact brings a plane 2-D interaction to the well known 1-D Newtonian concept. This adaptation transforms Classical Mechanics into a 1-D concept as well and presents a conformation that the linear concept is the only possible one. The Laws of Conservation of Momentum and Angular Momentum are results of the 1-D concept. But the world contains 3 geometrical spatial dimensions. Within the 3-D world there can exist 1-D, 2-D and 3-D kinds of interaction. The question is how to believe that the 3-D world can really be composed of a 1-D interaction or interactions made equal to the 1-D concept only? Examine a gyroscope - the only one mechanical device that is capable of performing 3-D behavior. The problem is that a gyroscope cannot perform three permanent and unidirectional torques that are fixed in space acting about perpendicular axes. This impossibility conforms to a 1-D concept. The idea is to find a solution that can be achieved for the 3-D concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Present status and plans for upgrading the Lujan neutron scattering center

The Lujan Center, part of the LANSCE accelerator complex at Los Alamos National Laboratory, operates a comprehensive neutron scattering facility for the U.S. Department of Energy that serves approximately 300 users per year. This paper will discuss the current instruments and status of the facility and also focus on the plans for a major upgrade of the Center including new instruments and enhancements to specific existing instruments. The instrument suite currently includes two reflectometers (one with full polarization), an engineering diffraction machine, a diffractometer specialized to pair-distribution analysis, 2 general purpose powder diffractometers, and 2 inelastic spectrometers. To complement these spectrometers, a full range of pressure, temperature, and magnetic field sample environments is available for users. As part of the planning for a forthcoming enhancement of Lujan Center, a series of workshops have been held over the past year to encourage user input to the design for new instruments as well as major upgrades of existing machines. Many of the planned facilities are designed to take advantage of the Lujan Center 20 Hz pulse repetition rate and cold source moderators, both of which are beneficial for high-resolution instruments using long neutron wavelengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress in obtaining an absolute calibration of a total deuterium-tritium neutron yield diagnostic based on copper activation

The 350-keV Cockroft-Walton accelerator at Sandia National laboratory's Ion Beam facility is being used to calibrate absolutely a total DT neutron yield diagnostic based on the {sup 63}Cu(n,2n){sup 62}Cu({beta}+) reaction. These investigations have led to first-order uncertainties approaching 5% or better. The experiments employ the associated-particle technique. Deuterons at 175 keV impinge a 2.6 {mu}m thick erbium tritide target producing 14.1 MeV neutrons from the T(d,n){sup 4}He reaction. The alpha particles emitted are measured at two angles relative to the beam direction and used to infer the neutron flux on a copper sample. The induced {sup 62}Cu activity is then measured and related to the neutron flux. This method is known as the F-factor technique. Description of the associated-particle method, copper sample geometries employed, and the present estimates of the uncertainties to the F-factor obtained are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Measurements of the European Muon Collaboration Effect in Very Light Nuclei

New Jefferson Lab data are presented on the nuclear dependence of the inclusive cross section from {sup 2}H, {sup 3}He, {sup 4}He, {sup 9}Be and {sup 12}C for 0.3<x<0.9, Q{sup 2}{approx_equal}3-6 GeV{sup 2}. These data represent the first measurement of the EMC effect for {sup 3}He at large x and a significant improvement for {sup 4}He. The data do not support previous A-dependent or density-dependent fits to the EMC effect and suggest that the nuclear dependence of the quark distributions may depend on the local nuclear environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Emergent Newtonian dynamics and the geometric origin of mass

We consider a set of macroscopic (classical) degrees of freedom coupled to an arbitrary many-particle Hamiltonian system, quantum or classical. These degrees of freedom can represent positions of objects in space, their angles, shape distortions, magnetization, currents and so on. Expanding their dynamics near the adiabatic limit we find the emergent Newton’s second law (force is equal to the mass times acceleration) with an extra dissipative term. In systems with broken time reversal symmetry there is an additional Coriolis type force proportional to the Berry curvature. We give the microscopic definition of the mass tensor. The mass tensor is related to the non-equal time correlation functions in equilibrium and describes the dressing of the slow degree of freedom by virtual excitations in the system. In the classical (high-temperature) limit the mass tensor is given by the product of the inverse temperature and the Fubini–Study metric tensor determining the natural distance between the eigenstates of the Hamiltonian. For free particles this result reduces to the conventional definition of mass. This finding shows that any mass, at least in the classical limit, emerges from the distortions of the Hilbert space highlighting deep connections between any motion (not necessarily in space) and geometry. We illustrate our findings with four simple examples. -- Highlights: •Derive the macroscopic Newton’s equation from the microscopic many-particle Schrödinger’s equation. •Deep connection between geometry and dynamics. •Geometrical interpretation of the mass of macroscopic object as deformation of Hilbert space. •Microscopic expression for mass and friction tensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics-constrained machine learning for electrodynamics without gauge ambiguity based on Fourier transformed Maxwell’s equations

We utilize a Fourier transformation-based representation of Maxwell’s equations to develop physics-constrained neural networks for electrodynamics without gauge ambiguity, which we label the Fourier–Helmholtz–Maxwell neural operator method. In this approach, both of Gauss’s laws and Faraday’s law are built in as hard constraints, as well as the longitudinal component of Ampère–Maxwell in Fourier space, assuming the continuity equation. An encoder–decoder network acts as a solution operator for the transverse components of the Fourier transformed vector potential, $\hat{A}_⟂(k,t)$, whose two degrees of freedom are used to predict the electromagnetic fields. This method was tested on two electron beam simulations. Among the models investigated, it was found that a U-Net architecture exhibited the best performance as it trained quicker, was more accurate and generalized better than the other architectures examined. We demonstrate that our approach is useful for solving Maxwell’s equations for the electromagnetic fields generated by intense relativistic charged particle beams and that it generalizes well to unseen test data, while being orders of magnitude quicker than conventional simulations. We show that the model can be re-trained to make highly accurate predictions in as few as 20 epochs on a previously unseen data set.

97 MATHEMATICS AND COMPUTING↗

Multinucleon transfer reactions for the {sup 28}Si+{sup 90,94}Zr systems in the region below and near the Coulomb barrier

Measurements on multinucleon transfer reactions for {sup 28}Si+{sup 90,94}Zr systems were performed at sub- and near-barrier energies. The fact that {sup 90}Zr has a closed neutron shell (N = 50) and {sup 94}Zr has four neutrons outside the closed shell, allows us to investigate the effects of shell closure and pairing correlation on multinucleon transfer mechanism. The experiment was performed with pulsed {sup 28}Si beam using the Heavy Ion Reaction Analyzer (HIRA) at Inter University Accelerator Centre (IUAC), New Delhi. Based on the Q-value considerations, it turned out that pickup channels were neutron transfer whereas stripping channels were proton transfer. For the {sup 28}Si+{sup 90}Zr system, the values of the slope parameter for two-neutron pickup turned out to be less than that for one-neutron pickup. The values of the slope parameter were almost the same for two-, three-, and four-neutron pickup channels in the case of the {sup 28}Si+{sup 94}Zr system. The transfer probabilities in the case of the {sup 28}Si+{sup 94}Zr system were much larger than those for the {sup 28}Si+{sup 90}Zr system, further supporting the fact that there is a correlation between the transfer channels and sub-barrier fusion cross-section enhancement. An odd-even staggering was observed in the extracted transfer probabilities at the barrier radius implying the role of pairing correlation in transfer reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon Activation Analysis at the Idaho Accelerator Center

Activation methods require minimal sample preparation and provide sufficiently high sensitivity for detecting the vast majority of the elements throughout the periodic table. In this paper we shall discuss photon activation analysis (PAA) at the Idaho Accelerator Center. The process of PAA begins with exposing a sample with photons in the energy range of 10 to 30 MeV. Many nuclides in the sample will become activated and, in turn, these radionuclides will decay by emitting characteristic radiation. These characteristic radiation decays are the telltale signatures for identifying elements which can then be measured with spectrometers such as a high-purity Germanium detector. PAA is not an 'absolute' method, as the samples under investigation must be irradiated along with a reference or calibrating material having a well-known elemental composition. The quantitative evaluation is performed through comparing the two resulting element spectra from the unknown sample and reference material. Besides the obvious advantage of being non-destructive, PAA has minimal contamination issues. Moreover, materials that are difficult to treat chemically, such as certain refractory metals, dusts, ashes, etc., offer no hindrance to the technique of PAA. A further advantage is that PAA is very well suited for investigated minute samples (sub-milligram dust particles) to very large ones (in the multi-kg range). PAA is a robust technique as there are no real limitations concerning the nature of material to be studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ionic wind generation by a wire-cylinder-plate corona discharge in air at atmospheric pressure

A wire-cylinder-plate electrode configuration is presented to generate ionic wind with a dc corona discharge in air at atmospheric pressure. The objective of the work is to maximize the power supplied to the flow in order to increase acceleration while avoiding breakdown. Thus, the proposed experimental setup addresses the problem of decoupling the mechanism of ion generation from that of ion acceleration. Using a wire-plate configuration as a reference, we have focused on improving the topography of the electric field to (1) separate the ionization and acceleration zones in space, and (2) guide the trajectory of charged particles as parallel to the median axis as possible. In the proposed wire-cylinder-plate setup, a dc corona discharge is generated in the space between a wire and two cylinders. The ions produced by the corona then drift past the cylinders and into a channel between two plates, where they undergo acceleration. To maximize the ionic wind it is found that the geometric configuration must be as compact as possible and that the voltage applied must be right below breakdown. Experimentally, the optimized wire-plate reference setup provides a maximum flow velocity of 8 m s{sup -1}, a flow rate per unit electrode length of 0.034 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.24 N m{sup -1}. The wire-cylinder-plate configuration provides a maximum flow velocity of 10 m s{sup -1}, a flow rate per unit electrode length of 0.041 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.35 N m{sup -1}. This 46% increase in thrust is obtained by increasing the electric power per unit electrode length by only 16% (from 175 to 210 W m{sup -1}), which confirms the gain in efficiency obtained with the decoupled system. In comparison with a simple wire-wire corona configuration, the wire-cylinder-plate configuration increases the ionic wind velocity by up to a factor of 3, and the thrust by an order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-medium {omega} mass from the {gamma}+Nb {yields} {pi}{sup 0{gamma}}+X reaction

Data on the photoproduction of {omega} mesons on nuclei have been reanalyzed in a search for in-medium modifications. The data were taken with the crystal barrel (CB)/two-arm photon spectrometer (TAPS) detector system at the ELectron Stretcher Anlage (ELSA) accelerator facility in Bonn. First results from the analysis of the data set were published by Trnka et al. [Phys. Rev. Lett. 94, 192303 (2005)], claiming a lowering of the {omega} mass in the nuclear medium by 14% at normal nuclear matter density. The extracted {omega} line shape was found to be sensitive to the background subtraction. For this reason a reanalysis of the same data set has been initiated, and a new method has been developed to reduce the background and to determine the shape and absolute magnitude of the background directly from the data. Details of the reanalysis and of the background determination are described. The {omega} signal on the Nb target, extracted in the reanalysis, does not show a deviation from the corresponding line shape on a LH{sub 2} target, measured as reference. The earlier claim of an in-medium mass shift is thus not confirmed. The sensitivity of the {omega} line shape to different in-medium modification scenarios is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗