Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Design of a subcritical multiplying low-enriched uranium externally driven neutron assembly at the Los Alamos neutron science center

The Sandia Pulsed Reactor (SPR) has had a long history of supplying short intense neutron bursts to test the survivability of critical weapons components. The most recent version, SPR III, was resurrected in 2005 in support of critical survivability testing for W-76 Life Extension Program and other testing for the Qualification Alternatives to SPR program. SPR has now been decommissioned. The SPR had a cylindrical shape, with an internal cylindrical cavity where samples were placed for testing. The approximate dimensions of the cavity were 16.5 cm radius, and 38.1 cm high. The uniformity of the fluence over the entire volume was {+-} 25%. The nominal fluence was 5.4 {center_dot} 10{sup 14} n/cm{sup 2}, 1 MeV Si equivalent (Si equivalent implies that the neutron spectrum, at energies other than 1 MeV, is weighted by its relative damage potential in silicon), with a pulse duration of 55 microseconds, FWHM. We propose a new facility as a replacement to the SPR pulsed neutron capabilities, utilizing the proton linear accelerator at the Los Alamos Neutron Science Center (LANSCE). Currently, LANSCE provides neutron beams generated by the 800 MeV proton beam, over 13 decades of energy, to five different facilities. LANSCE is in the process of being refurbished; the refurbishment project (LANSCE-R) is funded and due to be completed by 2014. In parallel to the refurbishment, the experimental user program will continue and provide 3000 hours of beam per year. LANSCE is also considering upgrade options in the framework of MaRIE (Materials and Radiation Interactions in Extreme). MaRIE is planned to be the new signature facility for Los Alamos for the foreseeable future. Hence, they expect LANSCE to continue to operate and provide beams for decades t come. They propose to use the 800 MeV proton beam, extracted from the Proton Storage Ring (PSR), to initiate a neutron pulse in a sub-critical multiplying assembly, fabricated from Low-Enriched Uranium (LEU). The reason for using LEU (rather than highly-enriched uranium) is that it is not considered an attractive material that requires a significant investment in security and materials protection.

43 PARTICLE ACCELERATORS↗

R and D energy recovery LINAC at Brookhaven National Laboratory

Collider Accelerator Department at BNL is in the final stages of developing the 20-MeV R and D energy recovery linac with super-conducting 2.5 MeV RF gun and single-mode super-conducting 5-cell RF linac. This unique facility aims to address many outstanding questions relevant for high current (up to 0.5 A of average current), high brightness energy-recovery linacs with novel ZigZag-type merger. Recent development in the R and D ERL plans include gun and 5-cell cavity (G5) test and possibility of using R and D ERL for proof-of-principle test of Coherent Electron Cooling at RHIC.

43 PARTICLE ACCELERATORS↗

Fabrication of First 4-m Coils for the LARP MQXFA Quadrupole and Assembly in Mirror Structure

The US LHC Accelerator Research Program is constructing prototype interaction region quadrupoles as part of the US in-kind contribution to the Hi-Lumi LHC project. The low-beta MQXFA Q1/Q3 coils have a 4-m length and a 150 mm bore. The design is first validated on short, one meter models (MQXFS) developed as part of the longstanding Nb3Sn quadrupole R&D by LARP in collaboration with CERN. In parallel, facilities and tooling are being developed and refined at BNL, LBNL, and FNAL to enable long coil production, assembly, and cold testing. Long length scale-up is based on the experience from the LARP 90 mm aperture (TQ-LQ) and 120 mm aperture (HQ and Long HQ) programs. A 4-m long MQXF practice coil was fabricated, water jet cut and analyzed to verify procedures, parts, and tooling. In parallel, the first complete prototype coil (QXFP01a) was fabricated and assembled in a long magnetic mirror, MQXFPM1, to provide early feedback on coil design and fabrication following the successful experience of previous LARP mirror tests.

43 PARTICLE ACCELERATORS↗

Target development using the method of High-Intensity Vibrational Powder Plating (HIVIPP) at the Center for Accelerator Target Science (CATS) at Argonne National Laboratory (ANL)

One of the primary goals of the Center for Accelerator Target Science (CATS) is to provide targets and foils in support of the ATLAS User Facility and the Low-Energy community at large. While a wide array of target production techniques are available at CATS, new methods that must be explored invariably arise. One such technique, the High-Intensity Vibrational Powder Plating (HIVIPP), was first reported in 1997 by Isao Sugai. It was developed to produce targets and stripper foils that were difficult to make by standard methods. At Argonne National Laboratory (ANL), we have successfully constructed and tested a simple system for this purpose. We have produced targets of carbon and titanium on various metal backings using the HIVIPP method. We are currently in the exciting phase of exploring the production of other elements, including isotopically enriched and radioactive material. This work is in progress and will be further detailed with specific examples.

47 OTHER INSTRUMENTATION↗

Commissioning the Front End Test Stand High Performance H{sup -} Ion Source at RAL

The RAL Front End Test Stand (FETS) is being constructed to demonstrate a chopped H- beam of up to 60 mA at 3 MeV with 50 p.p.s. and sufficiently high beam quality for future high-power proton accelerators (HPPA). High power proton accelerators with beam powers in the several megawatt range have many applications including drivers for spallation neutron sources, neutrino factories, waste transmuters and tritium production facilities. The aim of the FETS project is to demonstrate that chopped low energy beams of high quality can be produced and is intended to allow generic experiments exploring a variety of operational conditions. This paper details the first stage of construction- the installation and commissioning of the ion source. Initial performance figures are reported.

43 PARTICLE ACCELERATORS↗

Chiral vortaic effect and neutron asymmetries in heavy-ion collisions

We study the possibility of testing experimentally signatures of P-odd effects related to the vorticity of the medium. The chiral vortaic effect is generalized to the case of conserved charges different from the electric one. In the case of baryonic charge and chemical potential, such an effect should manifest itself in neutron asymmetries measured by the Multipurpose Detector at the Nuclotron-Based Ion Collider Facility accelerator complex. The required accuracy may be achieved in a few months of accelerator running. We also discuss polarization of the hyperons and P-odd correlations of particle momenta (handedness) as probes of vorticity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam Dynamics Studies at the PIP-II Injector Test Facility

A series of beam dynamic studies were performed in 2020-2021 at the PIP-II Injector Test Facility (PIP2IT) that has been built to validate the concept of the front-end of the PIP-II linac being constructed at Fermilab. PIP2IT is comprised of a 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1- MeV CW RFQ, followed by a 10-m Medium Energy Beam Transport (MEBT), 2 cryomodules accelerating the beam to 16 MeV and a High-Energy Beam Transport (HEBT) bringing the beam to a dump. This paper presents beam dynamics - related measurements performed at PIP2IT such as the Twiss parameters with Allison scanners, beam envelopes along the injector, and transverse and longitudinal rms emittance reconstruction. These measurements are compared with predictions from the beam dynamics code Tracewin.

43 PARTICLE ACCELERATORS↗

Testing of YUH-61A helicopter transmission in NASA Lewis 2240-kW (3000-hp facility

A helicopter transmission that was being considered for the Army's Utility Tactical Transport Attack System (UTTAS) was tested in the NASA Lewis 2240-kW (3000-hp) test facility to obtain the transmission's operational data. The results will form a vibration and efficiency data base for evaluation similar-class helicopter transmissions. The transmission's mechanical efficiency was determined to be 98.7 percent at its rated power level of 2080 kW (2792 hp). At power levels up to 113 percent of rated the transmission displayed 56 percent higher vibration acceleration levels on the right input than on the left input. Both vibration signature analysis and final visual inspection indicated that the right input spiral-bevel gear had poor contact patterns. The highest vibration meter level was 52 g's rms at the accessory gear, which had free-wheeling gearsets. At 113 percent power and 100 percent rated speed the vibration meter levels generally ranged from 3 to 25 g's rms.

Mitchell, A. M.↗

Noncovalently functionalized graphitic mesoporous carbon as a stable support of Pt nanoparticles for oxygen reduction

We report a durable electrocatalyst support, highly graphitized mesoporous carbon (GMPC), for oxygen reduction in polymer electrolyte membrane (PEM) fuel cells. GMPC is prepared through graphitizing the self-assembled soft-template mesoporous carbon (MPC) under high temperature. Heat-treatment at 2800 C greatly improves the degree of graphitization while most of the mesoporous structures and the specific surface area of MPC are retained. GMPC is then noncovalently functionalized with poly(diallyldimethylammonium chloride) (PDDA) and loaded with Pt nanoparticles by reducing Pt precursor (H{sub 2}PtCl{sub 6}) in ethylene glycol. Pt nanoparticles of {approx}3.0 nm in diameter are uniformly dispersed on GMPC. Compared to Pt supported on Vulcan XC-72 carbon black (Pt/XC-72), Pt/GMPC exhibits a higher mass activity towards oxygen reduction reaction (ORR) and the mass activity retention (in percentage) is improved by a factor of {approx}2 after 44 h accelerated degradation test under the potential step (1.4-0.85 V) electrochemical stressing condition which focuses on support corrosion. The enhanced activity and durability of Pt/GMPC are attributed to the graphitic structure of GMPC which is more resistant to corrosion. These findings demonstrate that GMPC is a promising oxygen reduction electrocatalyst support for PEM fuel cells. The approach reported in this work provides a facile, eco-friendly promising strategy for synthesizing stable metal nanoparticles on hydrophobic support materials.

30 DIRECT ENERGY CONVERSION↗

ILC Reference Design Report: Accelerator Executive Summary

The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radiofrequency (SCRF) accelerating cavities. The use of the SCRF technology was recommended by the International Technology Recommendation Panel (ITRP) in August 2004 [1], and shortly thereafter endorsed by the International Committee for Future Accelerators (ICFA). In an unprecedented milestone in high-energy physics, the many institutes around the world involved in linear collider R&D united in a common effort to produce a global design for the ILC. In November 2004, the 1st International Linear Collider Workshop was held at KEK, Tsukuba, Japan. The workshop was attended by some 200 accelerator physicists from around the world, and paved the way for the 2nd ILC Workshop in August 2005, held at Snowmass, Colorado, USA, where the ILC Global Design Effort (GDE) was officially formed. The GDE membership reflects the global nature of the collaboration, with accelerator experts from all three regions (Americas, Asia and Europe). The first major goal of the GDE was to define the basic parameters and layout of the machine--the Baseline Configuration. This was achieved at the first GDE meeting held at INFN, Frascati, Italy in December 2005 with the creation of the Baseline Configuration Document (BCD). During the next 14 months, the BCD was used as the basis for the detailed design work and value estimate (as described in section 1.6) culminating in the completion of the second major milestone, the publication of the draft ILC Reference Design Report (RDR). The technical design and cost estimate for the ILC is based on two decades of world-wide Linear Collider R&D, beginning with the construction and operation of the SLAC Linear Collider (SLC). The SLC is acknowledged as a proof-of-principle machine for the linear collider concept. The ILC SCRF linac technology was pioneered by the TESLA collaboration*, culminating in a proposal for a 500 GeV center-of-mass linear collider in 2001 [2]. The concurrent (competing) design work on a normal conducting collider (NLC with X-band [3] and GLC with X- or C-Band [4]), has advanced the design concepts for the ILC injectors, Damping Rings (DR) and Beam Delivery System (BDS), as well as addressing overall operations, machine protection and availability issues. The X- and C-band R&D has led to concepts for the RF power source that may eventually produce either cost and/or performance benefits. Finally, the European XFEL [5] to be constructed at DESY, Hamburg, Germany, will make use of the TESLA linac technology, and represents a significant on-going R&D effort which remains of great benefit for the ILC. The current ILC baseline assumes an accelerating gradient of 31.5 MV/m to achieve a centre-of-mass energy of 500 GeV. The high luminosity requires the use of high power and small emittance beams. The choice of 1.3 GHz SCRF is well suited to the requirements, primarily because the very low power loss in the SCRF cavity walls allows the use of long RF pulses, relaxing the requirements on the peak-power generation, and ultimately leading to high wall-plug to beam transfer efficiency. The primary cost drivers are the SCRF Main Linac technology and the Conventional Facilities (including civil engineering). The choice of gradient is a key cost and performance parameter, since it dictates the length of the linacs, while the cavity quality factor (Q{sub 0}) relates to the required cryogenic cooling power. The achievement of 31.5 MV/m as the baseline average operational accelerating gradient--requiring a minimum performance of 35 MV/m during cavity mass-production acceptance testing--represents the primary challenge to the global ILC R&D With the completion of the RDR, the GDE will shortly begin an engineering design study, closely coupled with a prioritized R&D program. The goal is to produce an Engineering Design Report (EDR) demonstrating readiness for construction by 2010, followed by start of construction in 2012. A seven-year construction phase is currently assumed, allowing operations to begin in 2019. This is consistent with a technically driven schedule for this international project.

43 PARTICLE ACCELERATORS↗

Full-Scale Vessel Testing of the Standard High-Solids Vessel for the Hanford Waste Treatment Plant Pretreatment Facility - 17282

Concerns over the mixing performance of the planned pulse-jet mixed (PJM) vessels for high solids applications in the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment (PT) Facility, led to the development of a standard high-solids vessel (SHSV) design and full-scale vessel testing. The SHSV is intended as a potential replacement for several high-level waste feed receipt and lag storage vessels, ultrafiltration feed preparation vessels, and plant wash vessels. The SHSV design concept uses multiple smaller vessels (60 500 to 79 500 liters nominal batch size) to replace larger vessels, providing redundancy, improved mixing (PJM design and spargers), monitoring (multi-level bubblers), reduced material at risk, and improved structural features. The SHSV also requires qualification of a single vessel design for high solids Newtonian and non-Newtonian slurry processing, rather than earlier multiple vessel designs. Qualification of the SHSV design for mixing will be achieved through full-scale vessel testing (FSVT) with a prototypic SHSV under a set of most adverse design conditions in conjunction with additional engineering analyses. An Integrated Technical Team consisting of the U.S. Department of Energy (DOE), Bechtel National, Inc. (BNI), and independent experts was established to accelerate and provide oversight and direction to the test program and SHSV qualification. This paper will present an overview of the SHSV, full-scale vessel test and qualification program, and the management program to achieve closure of technical issues associated with PJM vessel mixing and control systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Principle and Uncertainty Quantification of an Experiment Designed to Infer Actinide Neutron Capture Cross-Sections

An integral reactor physics experiment devoted to infer higher actinide (Am, Cm, Bk, Cf) neutron cross sections will take place in the US. This report presents the principle of the planned experiment as well as a first exercise aiming at quantifying the uncertainties related to the inferred quantities. It has been funded in part by the DOE Office of Science in the framework of the Recovery Act and has been given the name MANTRA for Measurement of Actinides Neutron TRAnsmutation. The principle is to irradiate different pure actinide samples in a test reactor like INL’s Advanced Test Reactor, and, after a given time, determine the amount of the different transmutation products. The precise characterization of the nuclide densities before and after neutron irradiation allows the energy integrated neutron cross-sections to be inferred since the relation between the two are the well-known neutron-induced transmutation equations. This approach has been used in the past and the principal novelty of this experiment is that the atom densities of the different transmutation products will be determined with the Accelerator Mass Spectroscopy (AMS) facility located at ANL. While AMS facilities traditionally have been limited to the assay of low-to-medium atomic mass materials, i.e., A < 100, there has been recent progress in extending AMS to heavier isotopes – even to A > 200. The detection limit of AMS being orders of magnitude lower than that of standard mass spectroscopy techniques, more transmutation products could be measured and, potentially, more cross-sections could be inferred from the irradiation of a single sample. Furthermore, measurements will be carried out at the INL using more standard methods in order to have another set of totally uncorrelated information.

74 ATOMIC AND MOLECULAR PHYSICS↗

9975 SHIPPING PACKAGE LIFE EXTENSION SURVEILLANCE PROGRAM RESULTS SUMMARY

Results from the 9975 Surveillance Program at the Savannah River Site (SRS) are summarized for justification to extend the life of the 9975 packages currently stored in the K-Area Materials Storage (KAMS) facility from 10 years to 15 years. This justification is established with the stipulation that surveillance activities will continue throughout this extended time to ensure the continued integrity of the 9975 materials of construction and to further understand the currently identified degradation mechanisms. The current 10 year storage life was developed prior to storage. A subsequent report was later used to extend the qualification of the 9975 shipping packages for 2 years for shipping plus 10 years for storage. However the qualification for the storage period was provided by the monitoring requirements of the Storage and Surveillance Program. This report summarizes efforts to determine a new safe storage limit for the 9975 shipping package based on the surveillance data collected since 2005 when the surveillance program began. KAMS is a zero-release facility that depends upon containment by the 9975 to meet design basis storage requirements. Therefore, to confirm the continued integrity of the 9975 packages while stored in KAMS, a 9975 Storage and Surveillance Program was implemented alongside the DOE required Integrated Surveillance Program (ISP) for 3013 plutonium-bearing containers. The 9975 Storage and Surveillance Program performs field surveillance as well as accelerated aging tests to ensure any degradation due to aging, to the extent that could affect packaging performance, is detected in advance of such degradation occurring in the field. The Program has demonstrated that the 9975 package has a robust design that can perform under a variety of conditions. As such the primary emphasis of the on-going 9975 Surveillance Program is an aging study of the 9975 Viton(reg.sign) GLT containment vessel O-rings and the Celotex(reg.sign) fiberboard thermal insulation at bounding conditions of radiation and elevated temperatures. Other materials of construction, however, are also discussed.

42 ENGINEERING↗

APEX: A Prime EXperiment at Jefferson Lab

APEX is an experiment at Thomas Jefferson National Accelerator Facility (JLab) in Virginia, USA, that searches for a new gauge boson ($A^\prime$) with sub-GeV mass and coupling to ordinary matter of $g^\prime \sim (10^{-6} - 10^{-2}) e$. Electrons impinge upon a fixed target of high-Z material. An $A^\prime$ is produced via a process analogous to photon bremsstrahlung, decaying to an $e^+ e^-$ pair. A test run was held in July of 2010, covering $m_{A^\prime}$ = 175 to 250 MeV and couplings $g^\prime/e \; \textgreater \; 10^{-3}$. A full run is approved and will cover $m_{A^\prime} \sim$ 65 to 525 MeV and $g^\prime/e \; \textgreater \; 2.3 \times10^{-4}$.

Beacham, James↗

International Linear Collider Accelerator Physics R&D

ILC work at Illinois has concentrated primarily on technical issues relating to the design of the accelerator. Because many of the problems to be resolved require a working knowledge of classical mechanics and electrodynamics, most of our research projects lend themselves well to the participation of undergraduate research assistants. The undergraduates in the group are scientists, not technicians, and find solutions to problems that, for example, have stumped PhD-level staff elsewhere. The ILC Reference Design Report calls for 6.7 km circumference damping rings (which prepare the beams for focusing) using “conventional” stripline kickers driven by fast HV pulsers. Our primary goal was to determine the suitability of the 16 MeV electron beam in the AØ region at Fermilab for precision kicker studies.We found that the low beam energy and lack of redundancy in the beam position monitor system complicated the analysis of our data. In spite of these issues we concluded that the precision we could obtain was adequate to measure the performance and stability of a production module of an ILC kicker, namely 0.5%. We concluded that the kicker was stable to an accuracy of ~2.0% and that we could measure this precision to an accuracy of ~0.5%. As a result, a low energy beam like that at AØ could be used as a rapid-turnaround facility for testing ILC production kicker modules. The ILC timing precision for arrival of bunches at the collision point is required to be 0.1 picosecond or better. We studied the bunch-to-bunch timing accuracy of a “phase detector” installed in AØ in order to determine its suitability as an ILC bunch timing device. A phase detector is an RF structure excited by the passage of a bunch. Its signal is fed through a 1240 MHz high-Q resonant circuit and then down-mixed with the AØ 1300 MHz accelerator RF. We used a kind of autocorrelation technique to compare the phase detector signal with a reference signal obtained from the phase detector’s response to an event at the beginning of the run. We determined that the device installed in our beam, which was instrumented with an 8-bit 500 MHz ADC, could measure the beam timing to an accuracy of 0.4 picoseconds. Simulations of the device showed that an increase in ADC clock rate to 2 GHz would improve measurement precision by the required factor of four. As a result, we felt that a device of this sort, assuming matters concerning dynamic range and long-term stability can be addressed successfully, would work at the ILC. Cost effective operation of the ILC will demand highly reliable, fault tolerant and adaptive solutions for both hardware and software. The large numbers of subsystems and large multipliers associated with the modules in those subsystems will cause even a strong level of unit reliability to become an unacceptable level of system availability. An evaluation effort is underway to evaluate standards associated with high availability, and to guide ILC development with standard practices and well-supported commercial solutions. One area of evaluation involves the Advanced Telecom Computing Architecture (ATCA) hardware and software. We worked with an ATCA crate, processor monitors, and a small amount of ATCA circuit boards in order to develop a backplane “spy” board that would let us watch the ATCA backplane communications and pursue development of an inexpensive processor monitor that could be used as a physics-driven component of the crate-level controls system. We made good progress, and felt that we had determined a productive direction to extend this work. We felt that we had learned enough to begin designing a workable processor monitor chip if there were to be sufficient interest in ATCA shown by the ILC community. Fault recognition is a challenging issue in the crafting a high reliability controls system. With tens of thousands of independent processors running hundreds of thousands of critical processes, how can the system identify that a problem has arisen and determine the appropriate steps to take to correct, or compensate, for the failure? One possible solution might come through the use of the OpenClovis supervisory system, which runs on Linux processors and allows a select set of processors to monitor the behavior of individual processes and processors in a large, distributed controls network. We found that OpenClovis exhibited an irritating amount of sensitivity to the exact version of the Linux kernel running on the processors, and that it was poorly equipped to help us sort through problems that arose through conflicts so deep in the operating systems of the processors. But once this issue was addressed, we found that it performed as expected, recognizing crashes and process (and processor) failures.

43 PARTICLE ACCELERATORS↗

Accelerated radiation tolerance testing of Ti-based MAX phases

MAX phases have recently attracted significant attention for potential nuclear applications due to their novel properties such as unique hexagonal-compact nanolayered crystal structure, high-machinability due to lower hardness levels compared to conventional ceramics, and high-chemical inertness. In order for MAX phases to be used in nuclear reactors, two aspects deserve detailed investigations: (i) their phase stability at high-temperatures and (ii) microstructural defect formation and recovery induced by energetic particle irradiation. To date, degradation mechanisms of MAX phases at high-temperatures and following irradiation are largely unexplored fields of research. This work focuses on the evaluation of two Ti-based MAX phases – Ti 2 AlC and Ti 3 SiC 2 – within the context of extreme environments. To accomplish this, a one-of-a-kind comparison between neutron irradiations, performed over a decade of research at the High Flux Isotope Reactor (HFIR), and heavy-ion irradiations, carried out in situ in a Transmission Electron Microscope (TEM) at the MIAMI-2 facility, has been conducted. The results show Ti-based MAX phases are prone to accelerated decomposition under the conditions investigated. This questions the hypothesis that MAX phases exhibit high phase stability, especially when used in future nuclear energy systems where energetic particle irradiation is a dominating degradation mechanism.

36 MATERIALS SCIENCE↗

UltraSciencenet: High- Performance Network Research Test-Bed

The high-performance networking requirements for next generation large-scale applications belong to two broad classes: (a) high bandwidths, typically multiples of 10Gbps, to support bulk data transfers, and (b) stable bandwidths, typically at much lower bandwidths, to support computational steering, remote visualization, and remote control of instrumentation. Current Internet technologies, however, are severely limited in meeting these demands because such bulk bandwidths are available only in the backbone, and stable control channels are hard to realize over shared connections. The UltraScience Net (USN) facilitates the development of such technologies by providing dynamic, cross-country dedicated 10Gbps channels for large data transfers, and 150 Mbps channels for interactive and control operations. Contributions of the USN project are two-fold: (a) Infrastructure Technologies for Network Experimental Facility: USN developed and/or demonstrated a number of infrastructure technologies needed for a national-scale network experimental facility. Compared to Internet, USN's data-plane is different in that it can be partitioned into isolated layer-1 or layer-2 connections, and its control-plane is different in the ability of users and applications to setup and tear down channels as needed. Its design required several new components including a Virtual Private Network infrastructure, a bandwidth and channel scheduler, and a dynamic signaling daemon. The control-plane employs a centralized scheduler to compute the channel allocations and a signaling daemon to generate configuration signals to switches. In a nutshell, USN demonstrated the ability to build and operate a stable national-scale switched network. (b) Structured Network Research Experiments: A number of network research experiments have been conducted on USN that cannot be easily supported over existing network facilities, including test-beds and production networks. It settled an open matter by demonstrating that the performance of switched connections and Multiple Protocol Label Switching tunnels over routed networks are comparable. Furthermore, such connections can be easily peered, and the performance of the resultant hybrid connections is still comparable to the constituent pure connections. USN experiments demonstrated that Infiniband transport can be effectively extended to wide-area connections of thousands of miles, which opens up new opportunities for efficient bulk data transport. USN provided dedicated connections to Cray X1 supercomputer and helped diagnose TCP performance problems which might have been otherwise incorrectly attributed to traffic on shared connections. USN contributed to the development of transport methods for dedicated connections to other traffic. Recently, experiments were conducted to assess the performance of application acceleration devices that employ flow optimization and data compression methods to improve TCP performance.

99 GENERAL AND MISCELLANEOUS↗

Aging Infrastructure: Application of System Health Monitoring at the Defense Waste Processing Facility - 16069

The disposition of high level waste (HLW) into borosilicate glass canistered waste forms began at SRS in 1996. Since that time, the Defense Waste Processing Facility (DWPF) has produced nearly four thousand HLW canisters. The DWPF is now approaching 20 years of radioactive service and 25 years of operation since the commencement of nonradioactive testing in 1990. Many facility systems are challenged by equipment or component obsolescence, which places a premium on proper work planning, engineering, and maintenance resource allocation to ensure facility reliability. To this end, Savannah River Remediation (SRR) implements programs and procedures for performance monitoring of structures, systems, and components (SSCs) within all of its processing facilities. As these programs have matured, they have helped to identify vulnerabilities within facility systems and provided a framework for ranking system assets to ensure correct priority is established and maintained. This paper provides an overview of how SRR structures and implements system performance monitoring with specific focus on the recent replacement of the DWPF Safety Grade Purge Flowmeters. This case study will discuss: 1) How the performance monitoring process identified an availability risk due to the minimal vendor support for the in-use flow transmitters, 2) The design changes developed as part of the project to transition to a different measurement technology, which includes operational lessons learned from the original installation, 3) The execution of the replacement effort, which was complicated by the fact that the purge system is a Vital Safety System (VSS) and not easily taken out of service for extended maintenance, and 4) The need to consider future maintainability, particularly given that continued acceleration in technical innovation will likely increase the frequency of equipment obsolescence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗