Neutron capture and neutron-induced fission experiments on americium isotopes with DANCE

Neutron capture cross section data on Am isotopes were measured using the Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory. The neutron capture cross section was determined for {sup 241}Am for neutron energies between thermal and 320 keV. Preliminary results were also obtained for {sup 243}Am for neutron energies between 10 eV and 250 keV. The results on concurrent neutron-induced fission and neutron-capture measurements on {sup 242m}Am will be presented where the fission events were actively triggered during the experiments. In these experiments, a Parallel-Plate Avalanche Counter (PPAC) detector that surrounds the target located in the center of the DANCE array was used as a fission-tagging detector to separate (n,{gamma}) events from (n,f) events. The first direct observation of neutron capture on {sup 242m}Am in the resonance region in between 2 and 9 eV of the neutron energy was obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Liquid-Cryogen-Free Cryostat for Ultrahigh Resolution Gamma-Ray Spectrometers

We are developing ultra-high energy resolution gamma-ray detectors based on superconducting transition edge sensors (TESs) for nuclear non-proliferation and fundamental science applications. They use bulk tin absorbers attached to molybdenum-copper multilayer TESs, and have achieved an energy resolution between 50 and 90 eV FWHM for gamma-ray energies below 122 keV. For increased user-friendliness, we have built a cryostat that attains the required detector operating temperature of 0.1 K at the push of a button without the use of cryogenic liquids. It uses a two-stage mechanical pulse tube refrigerator for precooling to {approx}3 K, and a two-stage adiabatic demagnetization refrigerator for cooling to the base temperature. The cryostat is fully automated, attains a base temperature below 30 mK without the use of cryogenic liquids, and has a hold time of {approx}2 days at 0.1 K between 1-hour demagnetization cycles. Here we discuss the performance of the cryostat for operation in a Gamma-spectrometer with 112-pixel arrays of superconducting TES detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a Plasma Panel Muon Detector

A radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays is being investigated. Emerging from this well established television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We report on the PPS development effort, including proof-of-principle results of laboratory signal observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial performance of the CUORE-0 experiment

CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130 Te. We present the first data analysis with 7.1kg • y of total TeO 2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57MeV) and in the α background-dominated region (2.70 to 3.90MeV) have been measured to be 0.071±0.011 and 0.019±0.002counts/(keV • kg • y), respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Neutrinoless Double-ß Decay in 76Ge with the Majorana Demonstrator

The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is comprised of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. Given the unprecedented energy resolution at Q of 2.5 keV FWHM and the very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, we find a lower limit on the half-life of 1:9 x 1025 yr (90% CL). This result constrains the effective Majorana neutrino mass to below 250 to 550 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4:0 +3:1(superscript) -2:5 (subscript) counts/(FWHM t yr) at 68% CL.

Aalseth, Craig E.↗

Source shape estimation for neutron imaging systems using convolutional neural networks

Neutron imaging systems are important diagnostic tools for characterizing the physics of inertial confinement fusion reactions at the National Ignition Facility (NIF). In particular, neutron images give diagnostic information on the size, symmetry, and shape of the fusion hot spot and surrounding cold fuel. Images are formed via collection of neutron flux from the source using a system of aperture arrays and scintillator-based detectors. Currently, reconstruction of fusion source geometry from the collected neutron images is accomplished by solving a computationally intensive maximum likelihood estimation problem via expectation maximization. In contrast, it is often useful to have simple representations of the overall source geometry that can be computed quickly. In this work, we develop convolutional neural networks (CNNs) to reconstruct the outer contours of simple source geometries. We compare the performance of the CNN for penumbral and pinhole data and provide experimental demonstrations of our methods on both non-noisy and noisy data.

Machine learning, neutron imaging, source reconstr↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Status and results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay [0$vββ$] of 130 Te. The detector consists of a segmented array of 988 natural TeO 2 cubic crystals arranged in a cylindrical compact structure of 19 towers. The detector construction was completed in August 2016 and data taking started in Spring 2017. Here, we present a brief description of the bolometric technique for rare events search and the CUORE detector, then we concentrate on the data analysis results. In this respect, we focus on the procedure for data processing and on the first 0$vββ$ results we obtained from a total TeO 2 exposure of 86.3 kg · yr. Next, we illustrate the main background sources and the CUORE background model, from which we obtain the most precise measurement of 130 Te 2$vββ$ half-life to date. Finally, we discuss the improvements achieved with 2018 and 2019 detector optimization campaigns and the current perspectives of our experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute energy calibration of FD by an electron linear accelerator for Telescope Array

The primary energy of the ultra-high energy cosmic rays(UHECR) are measured with the number of fluorescence photons which are detected with fluorescence detectors(FD) in the Telescope Array experiment(TA). Howevery since there is large uncertinty as 19% in the measurement of the energy scale, the most important theme is improvement of the energy calibration. The electron light source(ELS) is a small electron linear accelerator for new energy calibration. The ELS is located 100 m far from the FD station, and injects electron beam which is accelerated to 40 MeV energy into the sky. We can calibrate the FD energy scale by detection the air shower directly which is generated by the electron beam. The ELS was developed in KEK Japan, and moved to the TA site in March 2009. We started the beam operation in September 2010, in consequence we detected the air shower which was generated by electron beam in the air. The output kinetic energy of the electron beam was 41.1 MeV, we adjusted the output charge from 40 to 140 pC/pulse. We expect that we can improve the uncertinty of the energy scale to about 10% with the ELS, futhermore ELS will be a very useful apparatus for R and D of future UHECR observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shortwave Spectrometer (SWS) zenith radiance swsrad.b1 v3 and higher

Hyperspectral zenith radiances from the SWS instrument reported at 1 Hz. This data stream contains calibrated, dark-subtracted, radiances from two grating array spectrometers: a Si-detector based spectrometer denoted by SW and an InGaAs based detector denoted by LW. Spectra from both spectrometers are calibrated based on the spectral responsivity determined by reference against NIST-traceable light sources are reported independently as separate arrays having the same time record but wavelength dimension specified for each detector. Because the LW spectrometer is more susceptible to temperature-induced changes, a scale factor adjustment is applied the the LW spectra to yield agreement with the SW spectra over the wavelength range where they overlap. The final radiances incorporate QC to flag saturated values, periods where house-keeping fields fall outside acceptable bounds, and to flag pixels for which the spectral responsivity is not acceptable.

54 ENVIRONMENTAL SCIENCES↗

SPT-3G+: mapping the high-frequency cosmic microwave background using kinetic inductance detectors

We present the design and science goals of SPT-3G+, a new camera for the South Pole Telescope, which will consist of a dense array of 34100 kinetic inductance detectors measuring the cosmic microwave background (CMB) at 220, 285 and 345 GHz. The SPT-3G+ dataset will enable new constraints on the process of reionization, including measurements of the patchy kinematic Sunyaev-Zeldovich effect and improved constraints on the optical depth due to reionization. At the same time, it will serve as a pathfinder for the detection of Rayleigh scattering, which could allow future CMB surveys to constrain cosmological parameters better than from the primary CMB alone. In addition, the combined, multi-band SPT-3G and SPT-3G+ survey data, will have several synergies that enhance the original SPT-3G survey, including: extending the redshift-reach of SZ cluster surveys to z > 2; understanding the relationship between magnetic fields and star formation in our Galaxy; improved characterization of the impact of dust on inflationary B-mode searches; and characterizing astrophysical transients at the boundary between mm and sub-mm wavelengths. Finally, the modular design of the SPT-3G+ camera allows it to serve as an on-sky demonstrator for new detector technologies employing microwave readout, such as the on-chip spectrometers that we expect to deploy during the SPT-3G+ survey. In this paper, we describe the science goals of the project and the key technology developments that enable its powerful yet compact design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Informing direct neutron capture on tin isotopes near the N = 82 shell closure

Half of the elements heavier than iron are believed to be produced through the rapid neutron-capture process ($r$-process). The astrophysical environment(s) where the $r$-process occurs remains an open question, even after recent observations of neutron-star mergers and the associated kilonova. Features in the abundance pattern of $r$-process ashes may provide critical insight for distinguishing contributions from different possible sites, including neutron-star mergers and core-collapse supernovae. In particular, the largely unknown neutron-capture reaction rates on neutron-rich unstable nuclei near 132 Sn could have a significant impact on the final $r$-process abundances. To better determine these neutron-capture rates, the ($d,p$) reaction has been measured in inverse kinematics using radioactive ion beams of 126 Sn and 128 Sn and a stable beam of 124 Sn interacting with a (CD 2 )$_n$ target. An array of position-sensitive silicon strip detectors, including the Super Oak Ridge Rutgers University Barrel Array, was used to detect light reaction products. In addition to the present measurements, previous measurements of 130,132 Sn($d,p$) were reanalyzed using state-of-the-art reaction theory to extract a consistent set of spectroscopic factors for ($d,p$) reactions on even tin nuclei between the heaviest stable isotope 124 Sn and doubly magic 132 Sn. The spectroscopic information was used to calculate direct-semidirect ($n,γ$) cross sections, which will serve as important input for r-process abundance calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Dark Matter Search Using the Final SuperCDMS Soudan Dataset and the Development of a Large-Format, Highly-Multiplexed, Athermal-Phonon-Mediated Particle Detector

Over the past eighty years, numerous complementary observations of our universe have indicated that our current description of physics is far from complete. The “or- dinary matter”, such as electrons, protons, photons and neutrons, that constitutes the bulk of all human physical experiences is actually only a minority (about 16%) of the total mass of the universe. The remaining 84% is very poorly understood, but has profound effects on the dynamics and evolution of our universe. Because it does not interact with light, and is not observable in telescopes on earth, this extra mass is usually referred to as “dark matter”. Although the dark matter is poorly understood, Weakly Interacting Massive Particles (WIMPs) are a well-motivated candidate that can be directly detected via a non-gravitational interaction with nor- mal matter, potentially allowing for direct terrestrial detection and characterization of this dark matter. This dissertation is focused on this direct WIMP detect ion and will be broken into two main parts. The first part focuses on the blinded analysis of roughly three years of data collected from March 2012 to November 2015 by the SuperCDMS Soudan experiment. SuperCDMS Soudan consists of an array of 15, 0.6-kg, cryogenic, Ge iZIP particle detectors situated in a decommissioned iron mine in remote northern Minnesota. This analysis is optimized to be sensitive to theoretical WIMP masses above 10 GeV/$c^2$ . This result set the strongest limits for WIMP–germanium-nucleus interac- tions for WIMP masses greater than 12 Gev/$c^2$ and can be found here [1]. The second part focuses on the development new kind of particle detector in the style of a SuperCDMS iZIP, designed to simplify fabrication and readout, improve phonon-based position reconstruction, and help to scale to larger target arrays. These detectors replace the TES-based phonon sensors of the iZIP with Microwave Kinetic Inductance Detectors (MKIDs).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simulation study of the ability to detect power distribution perturbations in the texas A&M TRIGA reactor with self-powered neutron detectors

Given the variety of ways that nuclear reactor core power may be perturbed, reactor operators and developers are keen on understanding the accuracy and convergence time during which perturbations in reactor power distribution may be synthesized (i.e., inferred) from an array of in-core radiation detectors. A simulation study was conducted as described herein using a highly detailed model of the Texas A&M Training, Research, Isotopes, General Atomics Reactor, in which an array of self-powered neutron detectors (SPNDs) was considered for input to the power synthesis methodology. The core power synthesis is conducted using a point-based iterative method with an iterative loop built in to ensure working equation consistency. The forward problem of SPND response to simulated perturbations in reactor power was solved for Gaussian peak-type perturbations in the reactor power distribution. These perturbations varied in variance, amplitude, and core location to assess their impact on synthesis error and to determine the number of iterations required for convergence. A relation between the unique resolvability limit and perturbation width was identified such that the maximum synthesis error increased rapidly when the peak width went beneath this limit (a width approximating half the reactor’s fuel pin-to-pin pitch); this resolvability limit is specific to the SPND configuration and fuel segmentation considered herein. The synthesis error increased linearly with perturbation peak amplitude, whereas the convergence time increased nonlinearly. Perturbations located closer to the center of the core were synthesized more accurately, albeit with a higher number of required iterations. These findings provide a qualitative and quantitative understanding of the accuracy and speed at which different types of spatial power perturbations can be resolved in light-water reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The MAJORANA DEMONSTRATOR Neutrinoless Double-Beta Decay Experiment

The MAJORANA DEMONSTRATOR will search for the neutrinoless double-beta (ββ(0ν)) decay of the isotope 76 Ge with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate that the neutrino is its own antiparticle, demonstrate that lepton number is not conserved, and provide information on the absolute mass scale of the neutrino. The DEMONSTRATOR is being assembled at the 4850-foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be situated in a low-background environment and surrounded by passive and active shielding. Here we describe the science goals of the DEMONSTRATOR and the details of its design.

Abgrall, N.↗

Large scale anisotropy of UHECRs for the Telescope Array

The origin of Ultra High Energy Cosmic Rays (UHECRs) is one of the most interesting questions in astroparticle physics. Despite of the efforts by other previous measurements, there is no consensus of both of the origin and the mechanism of UHECRs generation and propagation yet. In this context, Telescope Array (TA) experiment is expected to play an important role as the largest detector in the northern hemisphere which consists of an array of surface particle detectors (SDs) and fluorescence detectors (FDs) and other important calibration devices. We searched for large scale anisotropy using SD data of TA. UHECRs are expected to be restricted in GZK horizon when the composition of UHECRs is proton, so the observed arrival directions are expected to exhibit local large scale anisotropy if UHECR sources are some astrophysical objects. We used the SD data set from 11 May 2008 to 7 September 2010 to search for large-scale anisotropy. The discrimination power between LSS and isotropy is not enough yet, but the statistics in TA is expected to discriminate between those in about 95% confidence level on average in near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗