Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Three dimensional radioisotope battery and methods of making the same

According to one embodiment, a product includes an array of three dimensional structures, where each of the three dimensional structure includes a semiconductor material; a cavity region between each of the three dimensional structures; and a first material in contact with at least one surface of each of the three dimensional structures, where the first material is configured to provide high energy particle and/or ray emissions.

07 ISOTOPE AND RADIATION SOURCES↗

XFEL SASE pulses can enhance time-dependent observables

Abstract X-ray free electron lasers (XFELs) have emerged as powerful sources of short and intense x-ray pulses. We propose a simple and robust procedure which takes advantage of the inherent stochasticity of self-amplified stimulated emission (SASE) pulses to enhance the time-resolution and signal strength of the recorded data. Notably, the proposed method is able to enhance the average signal without knowledge of the signal strength of individual shots. Simple metrics for the probe pulses are introduced, such as an effective pulse duration applicable to SASE pulses characterised in the time domain using e.g. an X-band transverse cavity. The approach is evaluated using simulated and real pulse data in the context of ultrafast electron dynamics in a molecule. Utilising H 2 as a model system, we demonstrate the efficacy of the method theoretically, successfully enhancing the predicted nonresonant ultrafast x-ray scattering signal associated with electron dynamics. The method presented is broadly applicable and offers a general strategy for enhancing time-dependent observables at XFELs.

data analysis↗

Solutal separation in a binary nanofluid due to thermodiffusion

Transport phenomena in porous media have received considerable attention due to an increasing interest in geothermal processes, chemical catalytic reactors, waste storage (especially geological or ocean storage of carbon dioxide), etc. Among others, oil industry has shown an increasing interest in studying diffusion phenomenon. Nanofluid is a term used to describe the suspension of low concentration of metallic and non-metallic nanoparticles in a base fluid. The size of a nanoparticle ranges from 10 to 100nm, and the conventional fluids used are water, ethylene glycol (C{sub 2}H{sub 6}O{sub 2}) or engine oil. Various studies have proven that nanoparticles improve the heat transfer of a base fluid. However, using various nanofluids it has been shown that the results could vary depending on different initial concentrations. The main objective of this paper is to study the diffusion and the thermodiffusion effect in a nanofluid for different fluid/porous media configurations. In this configuration, a liquid layer surrounds a porous layer. The full Brinkman equation coupled with the heat and mass transfer equations have been solved numerically for the porous layer using the finite element technique. The full Navier stokes equation coupled with heat and mass transfer equations have been solved for the liquid layer using the finite element method. A constraint between the liquid and porous layer has been applied to ensure heat flow and mass transfer continuity is maintained. A square cavity filled with hydrocarbon nanofluid of a mixture of fullerene-toluene with varying concentration of fullerene has been subject to different heating conditions. The entire cavity has been considered to be fully wetted with nanofluid. Results have confirmed that in the presence of a nanofluid a heat transfer enhancement is present up to certain initial concentration of the fullerene. The heat convection coefficient has been found to be 16% higher when a nanofluid is used as the working fluid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical cutting of irradiated reactor internal components

Mechanical cutting methods to volume reduce and package reactor internal components are now a viable solution for stakeholders challenged with the retirement of first generation nuclear facilities. The recent completion of the removal of the Reactor Vessel Internals (RVI) from within the Sacramento Municipal Utility District's (SMUD) Rancho Seco Nuclear Power Plant demonstrates that unlike previous methods, inclusive of plasma arc and abrasive water-jet cutting, mechanical cutting minimizes exposure to workers, costly water cleanup, and excessive secondary waste generation. Reactor internal components were segmented, packaged, and removed from the reactor building for shipment or storage, allowing the reactor cavity to be drained and follow-on reactor segmentation activities to proceed in the dry state. Area exposure rates at the work positions during the segmentation process were generally 1 mR per hr. Radiological exposure documented for the underwater segmentation processes totaled 13 person rem. The reactor internals weighing 343,000 pounds were segmented into over 200 pieces for maximum shipping package efficiency and produced 5,600 lb of stainless steel chips and shavings which were packaged in void spaces of existing disposal containers, therefore creating no additional disposal volume. Because no secondary waste was driven into suspension in the reactor cavity water, the water was free released after one pass through a charcoal bed and ion exchange filter system. Mechanical cutting techniques are capable of underwater segmentation of highly radioactive components on a large scale. This method minimized radiological exposure and costly water cleanup while creating no secondary waste.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Operation conditions for a picosecond laser with an aberration thermal lens under longitudinal pulsed diode pumping

The dependence of the repetition frequency range that provides stable operation of a picosecond laser with longitudinal pulsed diode pumping on the parameters of the laser cavity and the thermal lens induced in the active element is analysed. The results of calculating the radius of the lower cavity mode as a function of pump beam average power and diameter are reported. Based on the measurements by the probe-beam method, the adequacy of the presented model of aberration thermal lens is demonstrated for the cases of uniformly doped Nd:YAG and composite YAG/Nd:YAG active elements upon tuning the pump pulse repetition frequency within the range of 0 - 1 kHz. The ways for implementing stable generation of millijoule pulses in a specified repetition frequency range are discussed. (control of laser radiation parameters)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Insights from the APOKASC determination of the evolutionary state of red-giant stars by consolidation of different methods

ABSTRACT The internal working of low-mass stars is of great significance to both the study of stellar structure and the history of the Milky Way. Asteroseismology has the power to directly sense the internal structure of stars and allows for the determination of the evolutionary state – i.e. has helium burning commenced or is the energy generated only by the fusion in the hydrogen-burning shell? We use observational data from red-giant stars in a combination (known as APOKASC) of asteroseismology (from the Kepler mission) and spectroscopy (from SDSS/APOGEE). The new feature of the analysis is that the APOKASC evolutionary state determination is based on the comparison of diverse approaches to the investigation of the frequency-power spectrum. The high level of agreement between the methods is a strong validation of the approaches. Stars for which there is not a consensus view are readily identified. The comparison also facilitates the identification of unusual stars including those that show evidence for very strong coupling between p and g cavities. The comparison between the classification based on the spectroscopic data and asteroseismic data have led to a new value for the statistical uncertainty in APOGEE temperatures. These consensus evolutionary states will be used as an input for methods that derive masses and ages for these stars based on comparison of observables with stellar evolutionary models (‘grid-based modelling’) and as a training set for machine-learning and other data-driven methods of evolutionary state determination.

Elsworth, Yvonne↗

Computational Analysis of Interactions of the Oral Microbiota

The human oral microbiome is a complex site containing many hundreds of species with the community response of this microbiome having a large effect on human health. The complexity of this site has spoken to the need for applying –omics techniques to better understand which microbial species are present, their contribution to the microbiome and how this may change as a function of disease. The kinds of datasets that emerge from these –omics studies require computational analysis to gain robust results. New research has also been focused on applying these methods to build computational networks and models that better describe the myriad of interactions between microbial species of the oral cavity and how this changes as a result of infection. In this work, I describe the state of the field at this point, what kinds of computational networks have been inferred and what they show. I also describe where the field is heading in the next few years and how more in depth –omics analysis can lead to more detailed models of interactions at this site and improve human health.

-omics↗

A Phase 2 Trial of Stereotactic Radiosurgery Boost After Surgical Resection for Brain Metastases

Purpose: To evaluate local control after surgical resection and postoperative stereotactic radiosurgery (SRS) for brain metastases. Methods and Materials: A total of 49 patients (50 lesions) were enrolled and available for analysis. Eligibility criteria included histologically confirmed malignancy with 1 or 2 intraparenchymal brain metastases, age ≥18 years, and Karnofsky performance status (KPS) ≥70. A Cox proportional hazard regression model was used to test for significant associations between clinical factors and overall survival (OS). Competing risks regression models, as well as cumulative incidence functions, were fit using the method of Fine and Gray to assess the association between clinical factors and both local failure (LF; recurrence within surgical cavity or SRS target), and regional failure (RF; intracranial metastasis outside of treated volume). Results: The median follow-up was 12.0 months (range, 1.0-94.1 months). After surgical resection, 39 patients with 40 lesions were treated a median of 31 days (range, 7-56 days) later with SRS to the surgical bed to a median dose of 1800 cGy (range, 1500-2200 cGy). Of the 50 lesions, 15 (30%) demonstrated LF after surgery. The cumulative LF and RF rates were 22% and 44% at 12 months. Patients who went on to receive SRS had a significantly lower incidence of LF (P=.008). Other factors associated with improved local control include non-small cell lung cancer histology (P=.048), tumor diameter <3 cm (P=.010), and deep parenchymal tumors (P=.036). Large tumors (≥3 cm) with superficial dural/pial involvement showed the highest risk for LF (53.3% at 12 months). Large superficial lesions treated with SRS had a 54.5% LF. Infratentorial lesions were associated with a higher risk of developing RF compared to supratentorial lesions (P<.001). Conclusions: Postoperative SRS is associated with high rates of local control, especially for deep brain metastases <3 cm. Tumors ≥3 cm with superficial dural/pial involvement demonstrate the highest risk of LF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operation and Optimization of Microwave-Heated Continuous-Flow Microfluidics

Microwave (MW) technology can be powerful for electrification and process intensification but limited fundamental understanding of scalability and design principles hinders its effective use. In this work, we build a continuous-flow microreactor inside a commercial single-mode MW applicator and the corresponding computational fluid dynamics model to simulate the temperature profile. The model is in good agreement with experiments for various microreactor dimensions and operating conditions. The model indicates that MW heating is greatly influenced by reactor geometry as well as the operating parameters. We observe a strong correlation between parameters and develop a gradient boost regression tree model to predict the outlet temperature accurately. This model is then applied to optimize the dimensions and operating conditions to maximize the outlet temperature and energy efficiency, resulting in a Pareto optimal. We demonstrate computationally and experimentally that it is possible to surpass the Pareto optimal and achieve an energy efficiency of ~90% or greater at temperatures relevant for liquid-phase chemistry via salting of the solvent. The present methodology can be applied to other complex MW reactors. Lastly, the combined numerical and experimental approach provides insights into and a framework for scale-up and optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Copper dimer interactions on a thermomechanical superfluid {sup 4}He fountain

Laser induced fluorescence imaging and frequency domain excitation spectroscopy of the copper dimer (B{sup 1}Σ{sub g}{sup +}←X{sup 1}Σ{sub u}{sup +}) in thermomechanical helium fountain at 1.7 K are demonstrated. The dimers penetrate into the fountain provided that their average propagation velocity is ca. 15 m/s. This energy threshold is interpreted in terms of an imperfect fountain liquid-gas interface, which acts as a trap for low velocity dimers. Orsay-Trento density functional theory calculations for superfluid {sup 4}He are used to characterize the dynamics of the dimer solvation process into the fountain. The dimers first accelerate towards the fountain surface and once the surface layer is crossed, they penetrate into the liquid and further slow down to Landau critical velocity by creating a vortex ring. Theoretical lineshape calculations support the assignment of the experimentally observed bands to Cu{sub 2} solvated in the bulk liquid. The vibronic progressions are decomposed of a zero-phonon line and two types of phonon bands, which correlate with solvent cavity interface compression (t < 200 fs) and expansion (200 < t < 500 fs) driven by the electronic excitation. The presented experimental method allows to perform molecular spectroscopy in bulk superfluid helium where the temperature and pressure can be varied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mathematical modelling of dispersion-managed thulium/holmium fibre lasers

The mathematical model of a dispersion-managed thulium/holmium fibre laser is described; the results of numerical calculations and their comparison with the experimental data are presented. Qualitative agreement of the results of the mathematical modelling with those of the experiment is obtained. Using the methods of mathematical modelling, the variation in the characteristics of the optical pulses due to the change in the average cavity dispersion is analysed. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum gates on asynchronous atomic excitations

A method for realising a universal system of quantum gates based on asynchronous excitations of two-level atoms in optical cavities is proposed. The entangling operator of the CSign type is implemented without beam splitters, approximately, using the incommensurability of the Rabi oscillation periods in a cavity with single and double excitations. (quantum technology)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

POLARIMETRIC IMAGING OF LARGE CAVITY STRUCTURES IN THE PRE-TRANSITIONAL PROTOPLANETARY DISK AROUND PDS 70: OBSERVATIONS OF THE DISK

We present high-resolution H-band polarized intensity (FWHM = 0.''1: 14 AU) and L'-band imaging data (FWHM = 0.''11: 15 AU) of the circumstellar disk around the weak-lined T Tauri star PDS 70 in Centaurus at a radial distance of 28 AU (0.''2) up to 210 AU (1.''5). In both images, a giant inner gap is clearly resolved for the first time, and the radius of the gap is {approx}70 AU. Our data show that the geometric center of the disk shifts by {approx}6 AU toward the minor axis. We confirm that the brown dwarf companion candidate to the north of PDS 70 is a background star based on its proper motion. As a result of spectral energy distribution fitting by Monte Carlo radiative transfer modeling, we infer the existence of an optically thick inner disk at a few AU. Combining our observations and modeling, we classify the disk of PDS 70 as a pre-transitional disk. Furthermore, based on the analysis of L'-band imaging data, we put an upper limit of {approx}30 to {approx}50 M{sub J} on the mass of companions within the gap. Taking into account the presence of the large and sharp gap, we suggest that the gap could be formed by dynamical interactions of sub-stellar companions or multiple unseen giant planets in the gap.

79 ASTRONOMY AND ASTROPHYSICS↗

CATALYST AMMONIA STORAGE MEASUREMENTS USING RADIO FREQUENCY SENSING

Motivated by increasingly strict NO x limits, engine manufactures have adopted selective catalytic reduction (SCR) technology to reduce engine-out NO x below mandated levels. In the SCR process, nitrogen oxides (NO x ) react with ammonia (NH 3 ) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NO x and/or NH 3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF) -based method to directly monitor the ammonia storage state of the SCR catalyst. This approach utilizes the SCR catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH 3 ) were evaluated over a wide frequency range as well as temperature and exhaust conditions. The RF response to NH 3 storage, desorption, and oxidation on the SCR was observed to be well-correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10 % of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NO x conversion and decrease urea consumption.

Aguilar, Jonathan↗

WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia

Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.

60 APPLIED LIFE SCIENCES↗

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes in MRI- and CT-planned treatments were, respectively, −0.761 mm in the y-direction and 0.428 mm in the x-direction, well within safe limits. Conclusions: The highly accurate dose delivery was possible because the Gamma Knife, MRI scanner, and other equipment performed within tight limits and scans were acquired using the thinnest slices and smallest pixel sizes available. Had the individual devices performed only near the limits of their specifications, the cumulative error could have left parts of the trigeminal nerve undertreated. The presented end-to-end test gives assurance that patients had received the expected high quality treatment. End-to-end tests should become part of clinical practice.

60 APPLIED LIFE SCIENCES↗

SU-E-T-617: Plan Quality Estimation of Intensity-Modulated Radiotherapy Cases for Lung Cancer

Purpose: To estimate the planning quality of intensity-modulated radiotherapy in lung cancer cases and to provide preliminary data for the development of a planning quality assurance algorithm. Methods: 42 IMRT plans previously used in cases of solitary lung cancers were collected. Organs in or near the thoracic cavity, such as lung (ipsilateral, contralateral), heart, liver, esophagus, cord and bronchus were considered as organs at risk (OARs) in this study. The coverage index (CVI), conformity index (CI), homogeneity index (HI), volume, irregularity (standard deviation of center-surface distance) were used to compare PTV dose characteristics. The effective uniform dose (EUD), V10Gy, and V20Gy of the OARs were used to compare OAR dose characteristics. Results: Average CVI, CI, HI values were 0.9, 0.8, 0.1, respectively. CVI and CI had narrow Gaussian distribution curves without a singular value, but one case had a relatively high (0.25) HI because of location and irregular shape (Irregularity of 18.5 when average was 12.5) of PTV. EUDs tended to decrease as OAR-PTV distance increased and OAR-PTV overlap volume decreased. Conclusion: This work indicates the potential for significant plan quality deviation of similar lung cancer cases. Considering that this study were from a single department, differences in the treatment results for a given patient would be much more pronounced if multiple departments (and therefore more planners) were involved. Therefore, further examination of QA protocols is needed to reduce deviations in radiation treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantum theory of an optical maser. VI - Transient behavior.

The transient behavior of a laser is discussed using the quantum theory as did Scully and Lamb. The formal solution of the density-matrix equation is expressed in terms of exponentially decaying eigenmodes. Some of the lower decay constants are obtained numerically. The equations for the moments of the density matrix are then derived and solved by a truncation method. The equations of motion are integrated numerically for the case where the average number of photons in a laser cavity has the realistically large value 1.3 x 100,000. An alternative Fokker-Planck-equation approach is discussed.

Wang, Y. K.↗