Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

TU-AB-BRA-12: Quality Assurance of An Integrated Magnetic Resonance Image Guided Adaptive Radiotherapy Machine Using Cherenkov Imaging

Purpose: To investigate the viability of using Cherenkov imaging as a fast and robust method for quality assurance tests in the presence of a magnetic field, where other instruments can be limited. Methods: Water tank measurements were acquired from a clinically utilized adaptive magnetic resonance image guided radiation therapy (MR-IGRT) machine with three multileaf-collimator equipped 60Co sources. Cherenkov imaging used an intensified charge coupled device (ICCD) camera placed 3.5m from the treatment isocenter, looking down the bore of the 0.35T MRI into a water tank. Images were post-processed to make quantitative comparison between Cherenkov light intensity with both film and treatment planning system predictions, in terms of percent depth dose curves as well as lateral beam profile measurements. A TG-119 commissioning test plan (C4: C-Shape) was imaged in real-time at 6.33 frames per second to investigate the temporal and spatial resolution of the Cherenkov imaging technique. Results: A .33mm/pixel Cherenkov image resolution was achieved across 1024×1024 pixels in this setup. Analysis of the Cherenkov image of a 10.5×10.5cm treatment beam in the water tank successfully measured the beam width at the depth of maximum dose within 1.2% of the film measurement at the same point. The percent depth dose curve for the same beam was on average within 2% of ionization chamber measurements for corresponding depths between 3–100mm. Cherenkov video of the TG-119 test plan provided qualitative agreement with the treatment planning system dose predictions, and a novel temporal verification of the treatment. Conclusions: Cherenkov imaging was successfully used to make QA measurements of percent depth dose curves and cross beam profiles of MRI-IGRT radiotherapy machines after only several seconds of beam-on time and data capture; both curves were extracted from the same data set. Video-rate imaging of a dynamic treatment plan provided new information regarding temporal dose deposition. This study has been funded by NIH grants R21EB17559 and R01CA109558, as well as Norris Cotton Cancer Center Pilot funding.

60 APPLIED LIFE SCIENCES↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle{sup 3}), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA verification.

07 ISOTOPE AND RADIATION SOURCES↗

SECONDARY ECLIPSE PHOTOMETRY OF THE EXOPLANET WASP-5b WITH WARM SPITZER

We present secondary eclipse photometry of the extrasolar planet WASP-5b taken in the 3.6 and 4.5 {mu}m bands with the Spitzer Space Telescope's Infrared Array Camera as part of the extended warm mission. By estimating the depth of the secondary eclipse in these two bands we can place constraints on the planet's atmospheric pressure-temperature profile and chemistry. We measure secondary eclipse depths of 0.197% {+-} 0.028% and 0.237% {+-} 0.024% in the 3.6 {mu}m and 4.5 {mu}m bands, respectively. For the case of a solar-composition atmosphere and chemistry in local thermal equilibrium, our observations are best matched by models showing a hot dayside and, depending on our choice of model, a weak thermal inversion or no inversion at all. We measure a mean offset from the predicted center of eclipse of 3.7 {+-} 1.8 minutes, corresponding to ecos {omega} = 0.0025 {+-} 0.0012 and consistent with a circular orbit. We conclude that the planet's orbit is unlikely to have been perturbed by interactions with another body in the system as claimed by Fukui et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of insertion loss, laser profile and inhomogeneity of dots distribution on properties of all-optical modulator based on GaN/AlN quantum dots

This paper reports the effects of insertion loss, laser profile and inhomogeneity of dots distribution on properties of an all-optical modulator based on spherical quantum dot. The aim of this paper is to give a quantitative description for the variation of main properties of an all-optical quantum dot modulator such as, absorption, transmission and modulation depth regard to insertion loss, laser profile and inhomogeneity of dots. To realize these points, first, we extract the field distribution in optical fiber and channel waveguide (modulator) which are defined by their structure characteristics and boundary conditions. Using the electric field equations, input coupling efficiency and insertion loss and also role of laser profile are observable. Finally we investigate the effect of size distribution and inhomogeneity of quantum dots on the modulator performance. In this structure we used electromagnetically induced transparency (EIT) in GaN/AlN structure, associated with inter-sublevel transitions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Meteorology and Snow Data Set From Adjacent Forested and Meadow Sites at Crested Butte, CO, USA

We present meteorology and snow observation data collected at sites in the southwestern Colorado Rocky Mountains (USA) over three consecutive water years with different amounts of snow water equivalent (SWE) accumulation: A year with above average SWE (2019), a year with average SWE (2020), and a year with below average SWE (2021). This data set is distinguished by its emphasis on paired open-forest sites in a continental snow climate. Approximately once a month during February–May, we collected data from 15 to 20 snow pits and took 8 to 19 snow depth transects. Our sampling sites were in open and adjacent forested areas at 3,100 m and in a lower elevation aspen (3,035 m) and higher elevation conifer stand (3,395 m). In total, we recorded 270 individual snow pit density and temperature profiles and over 4,000 snow depth measurements. These data are complimented by continuous meteorological measurements from two weather stations: One in the open and one in the adjacent forest. Meteorology data—including incoming shortwave and longwave radiation, outgoing shortwave radiation, relative humidity, wind speed, snow depth, and air and infrared surface temperature—were quality controlled and the forcing data were gap-filled. These data are available to download from Bonner, Smyth, et al. at three levels of processing, including a level with downscaled, adjusted precipitation based on data assimilation using observed snow depth and a process-based snow model. We demonstrate the utility of these data with a modeling experiment that explores open-forest differences and identifies opportunities for improvements in model representation.

54 ENVIRONMENTAL SCIENCES↗

Water foraging with dynamic roots in E3SM; The role of roots in terrestrial ecosystem memory on intermediate timescales (Final Technical Report)

Terrestrial ecosystems can show sustained responses to stress events that may last for years after the initial perturbation. This phenomenon is referred to as legacy or memory and it emerges from a set of ecosystem processes that are poorly captured by Earth System and Land Surface Models. Consequently, these models struggle to predict the impact that extreme climate events have on surface energy, carbon and hydrological exchange once a stressor such as drought has relaxed or in response to repeated exposure to stress. In this project, we set out to test how the addition of dynamic root profiles in land surface models impact the capacity for Earth System Models, such as the Department of Energy’s E3SM, to capture realistic legacy effects. Observations have shown that vegetation shifts their root profiles during stress events to forage for water and these altered root profiles may take years to relax back to the initial state. We hypothesized that the alteration of the belowground root structures may be a source of terrestrial ecosystem legacy that is missing from models. To test this idea we undertook three core activities. (1) We developed a global-scale analysis of the impact of dynamic roots on ecosystem legacy building from a recently developed dynamic root module. (2) We developed new root dynamics in the DOE’s Energy Land Model (ELM) that allowed not only root profiles to shift their profile but also simultaneously alter carbon allocation to fine root pools. We then tested the impact of these new dynamics with intensive sensitivity analysis at four long-term AmeriFlux sites. (3) We undertook detailed isotopic analysis of tree rings from these AmeriFlux sites to assess ecophysiological and ecohydrological legacy to stress events that can be used to benchmark the sensitivity experiments with ELM. From these core activities, we report the following key findings. Firstly, on a global scale, the addition of dynamic roots led to chronically water-stressed ecosystems recovering faster to climate stress while wetter ecosystem showed enhanced legacy. This is because across ecosystems, stress events were almost universally associated with water shortages that led to the development of deeper root profiles. These deeper root profiles proved beneficial for recovery from drought stress. While the root dynamics did not universally improve the modeled representation of legacy it showed complex transient dynamics that emerge from the addition of dynamic roots. Secondly, the sensitivity analysis illustrated long term shifts in rooting depths away from the prescribed default profile suggesting that initializing of root profiles could benefit from spin-up simulations that converge on locally optimized root profiles. In addition, by enabling dynamic allocation some of the sites predicted unrealistically low allocation to roots (and high allocation to leaves). While these changes did not dramatically alter modeled gross primary productivity, they illustrated that without more sophisticated root processes in models, there is little penalty to dramatically disinvest in roots. Thirdly, the isotopic analysis of tree rings showed highly distinct legacy responses across species and sites. For example, T. canadensis showed reduced transpiration the year after stress events illustrated by sustained elevated $\delta^{18}$O. In contrast, A saccharum displayed elevated $\delta^{13}$C associated with reduced stomatal conductance in response to the previous years’ stress event. These geochemical signatures of legacy were present despite tree growth returning to normal the year after the stress. The results show the importance of species-level dynamics in legacy that are absent in modeling that assumes common traits within plant functional types. In summary, the work here established new avenues to explore root dynamics in models while illustrating how additional root processes are needed before dynamic carbon allocation can be implemented. Lastly, this project provided mentorship to a postdoctoral fellow, training for an early career scientist and multiple undergraduate students recruited from a minority serving institution.

54 ENVIRONMENTAL SCIENCES↗

Aerobic respiration controls on shale weathering, Geochimica et Cosmochimica Acta, 2023: Dataset

This data package was generated in order to support the development of a deep-time weathering model and to assess the coupling between shale weathering and aerobic respiration in the paper “Aerobic respiration controls on shale weathering” by Stolze et al., Geochimica et Cosmochimica Acta (2023). The package contains two csv files providing the average CO2(g) concentration profiles [ppm] and mineral concentration profiles [wt%], respectively. The CO2(g) concentration profiles were measured in the vicinity of the monitoring well PLM2 between January 2018 and April 2019. The gas samples were collected in the unsaturated zone to a depth of 1.52 m. The mineral concentration profiles were determined by X-Ray diffraction (XRD). The XRD measurements were performed on sub-core samples collected in the monitoring well PLM3 down to a depth of 7.01 m. The dataset additionally includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.Update on 2024-05-28: Revised versions of the CSV data files (CO2_data_GCA_Stolze_et_al_2023.csv and XRD_data_GCA_Stolze_et_al_2023.csv) were made to apply ESS-DIVE's CSV reporting format guidelines. Updated versions of the File Level Metadata (v2_20240528_flmd.csv) and Data Dictionary (v2_20240528_dd.csv) files were updated to reflect the changes made to the CSV files.

54 ENVIRONMENTAL SCIENCES↗

SU-G-TeP1-04: Deriving Spot Shape Criteria for Proton Pencil Beam Scanning

Purpose: The shape of a single beam in proton PBS influences the resulting dose distribution. Spot profiles are modelled as two-dimensional Gaussian (single/ double) distributions in treatment planning systems (TPS). Impact of slight deviations from an ideal Gaussian on resulting dose distributions is typically assumed to be small due to alleviation by multiple Coulomb scattering (MCS) in tissue and superposition of many spots. Quantitative limits are however not clear per se. Methods: A set of 1250 deliberately deformed profiles with sigma=4 mm for a Gaussian fit were constructed. Profiles and fit were normalized to the same area, resembling output calibration in the TPS. Depth-dependent MCS was considered. The deviation between deformed and ideal profiles was characterized by root-mean-squared deviation (RMSD), skewness/ kurtosis (SK) and full-width at different percentage of maximum (FWxM). The profiles were convolved with different fluence patterns (regular/ random) resulting in hypothetical dose distributions. The resulting deviations were analyzed by applying a gamma-test. Results were compared to measured spot profiles. Results: A clear correlation between pass-rate and profile metrics could be determined. The largest impact occurred for a regular fluence-pattern with increasing distance between single spots, followed by a random distribution of spot weights. The results are strongly dependent on gamma-analysis dose and distance levels. Pass-rates of >95% at 2%/2 mm and 40 mm depth (=70 MeV) could only be achieved for RMSD<10%, deviation in FWxM at 20% and root of quadratic sum of SK <0.8. As expected the results improve for larger depths. The trends were well resembled for measured spot profiles. Conclusion: All measured profiles from ProBeam sites passed the criteria. Given the fact, that beam-line tuning can result shape distortions, the derived criteria represent a useful QA tool for commissioning and design of future beam-line optics.

07 ISOTOPE AND RADIATION SOURCES↗

Depth-resolved sagebrush root metabolomics, rhizosphere microbial communities, and geochemistry at the East River Watershed

This data set consists of results from soil nutrient profile, untargeted metabolomics, mass spec imaging, and amplicon sequencing. Data for soil nutrient profile includes common cations (Ca, Mg, Na, and K etc.) extracted from 3 digesting steps – ammonia acetate (for exchangeable cations), nitric acid (for acid dissolved fraction), and hydrofluoric acid/perchloric acid (HF/HClO4) for whole soil digestion. It also includes concentration of organic carbon, inorganic nitrogen (ammonia and nitrate) and phosphorus (Bray-1 P and nitric acid extract), and total nitrogen and phosphorus. Data for untargeted metabolomics includes metabolomic profile for root exudate/tissues and soil extracts from depths at surface soil to saprolite, that were measured using gas chromatography – mass spectrometry (GC-MS), and liquid chromatography – tandem mass spectrometry (LC-MS/MS). Data for mass spec imaging includes spatial distribution of metabolites that were detected and annotated with Fourier transformation ion cyclotron resonance mass spectrometer (FTICR-MS). Data for amplicon sequencing includes the base paired 16S and ITS ribosomal RNA sequences from Miseq Illumina sequencing. All samples were collected from 2 sampling campaign October 2022 and June 2023. Collectively, these datasets enable a mechanistic evaluation of how nutrient acquisition, especially nitrogen and phosphorus, differs between shallow roots operating in soil and deep roots functioning within the fractured bedrock zone. All files are provided as comma-separated values (CSV) fies (.csv) and (GZIP) file (.gz). The compressed .gz FASTQ files can be read directly in R using the dada2 package as part of the amplicon sequence analysis workflow. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. This research was performed on a project award 60563 (https://dx.doi.org/10.46936/expl.proj.2022.60563/60008727) from the Environmental Molecular Sciences Laboratory, a DOE Office of Science User Facility sponsored by the Biological and Environmental Research program under Contract No. DE-AC05-76RL01830.

EARTH SCIENCE > AGRICULTURE > SOILS > CARBON↗

WE-EF-303-07: Imaging of Prompt Gamma Rays Emitted During Delivery of Clinical Proton Beams with a Compton Camera: Feasibility Studies for Range Verification

Purpose: Evaluation of a prototype Compton camera (CC) for imaging prompt gamma rays (PG) emitted during clinical proton beam irradiation for in vivo beam range verification. Methods: We irradiated a water phantom with 114 MeV and 150 MeV proton pencil beams at clinical beam currents ranging from 1 nA up to 5 nA. The CC was placed 15 cm from the beam central axis and PGs from 0.2 MeV up to 6.5 MeV were measured during irradiation. From the measured data, 2-dimensional (2D) PG images were reconstructed. One-dimensional (1D) profiles from the PG images were compared to measured depth dose curves. Results: The CC was able to measure PG emission during delivery of both a single 150 MeV pencil beam and a 5 cm x 5 cm mono-energetic layer of 114 MeV pencil beams. From the 2D images, a strong correlation was seen between the depth of the distal falloff of PG emission and the Bragg peak (BP). 1D profiles extracted from the PG images show that the distal 60% falloff of the PG emission lined up well with the distal 90% of the BP. Shifts as small as 3 mm in the beam range could be detected on both the 2D PG images and 1D profiles with an uncertainty of 1.5 mm. With the current CC prototype, a minimum dose delivery of 400 cGy was required to produce usable PG images. Conclusions: It was possible to measure and image PG emission with our prototype CC during proton beam delivery and to detect shifts in the BP range in the images. Therefore prompt gamma imaging with a CC for the purpose of in vivo range verification is feasible. However, for the studied system improvements in detector efficiency and reconstruction algorithms are necessary to make it clinically viable.

60 APPLIED LIFE SCIENCES↗

Aerosol Direct Radiative Effects at the ARM SGP and TWP Sites: Clear Skies

The clear-sky aerosol direct radiative effect (DRE) was estimated at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) and Tropical Western Pacific (TWP) sites. The NASA Langley Fu-Liou radiation model was used with observed inputs including aerosol vertical extinction profile from the Raman lidar; spectral aerosol optical depth (AOD), single-scattering albedo and asymmetry factor from Aerosol Robotic Network; temperature and water vapor profiles from radiosondes; and surface shortwave (SW) spectral albedo from radiometers. A radiative closure experiment was conducted for clear-sky conditions. The mean differences of modeled and observed surface downwelling SW total fluxes were 1 W m-2 at SGP and 2 W m -2 at TWP, which are within observational uncertainty. At SGP, the estimated annual mean clear-sky aerosol DRE is -3.00 W m -2 at the top of atmosphere (TOA) and -6.85 W m -2 at the surface. The strongest aerosol DRE of -4.81 (-10.77) W m -2 at the TOA (surface) are in the summer when AODs are largest. The weakest aerosol DRE of -.28 (-2.77) W m -2 at the TOA (surface) are in November–January when AODs and single-scattering albedos are lowest. At TWP, the annual mean clear-sky DRE is -2.82 W m-2 at the TOA and -10.34 W m -2 at the surface. The strongest aerosol DRE of -5.95 (-22.20) W m -2 at the TOA (surface) are in November (October) due to the biomass burning season’s peak. The weakest aerosol DRE of -0.96 (-4.16) W m -2 at the TOA (surface) are in March (April) when AODs are smallest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring toroidal anvil profiles for larger sample volumes above 4 Mbar

Abstract With the advent of toroidal and double-stage diamond anvil cells (DACs), pressures between 4 and 10 Mbar can be achieved under static compression, however, the ability to explore diverse sample assemblies is limited on these micron-scale anvils. Adapting the toroidal DAC to support larger sample volumes offers expanded capabilities in physics, chemistry, and planetary science: including, characterizing materials in soft pressure media to multi-megabar pressures, synthesizing novel phases, and probing planetary assemblages at the interior pressures and temperatures of super-Earths and sub-Neptunes. Here we have continued the exploration of larger toroidal DAC profiles by iteratively testing various torus and shoulder depths with central culet diameters in the 30–50 µm range. We present a 30 µm culet profile that reached a maximum pressure of 414(1) GPa based on a Pt scale. The 300 K equations of state fit to our P–V data collected on gold and rhenium are compatible with extrapolated hydrostatic equations of state within 1% up to 4 Mbar. This work validates the performance of these large-culet toroidal anvils to > 4 Mbar and provides a promising foundation to develop toroidal DACs for diverse sample loading and laser heating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SECONDARY ECLIPSE PHOTOMETRY OF WASP-4b WITH WARM SPITZER

We present photometry of the giant extrasolar planet WASP-4b at 3.6 and 4.5 {mu}m taken with the Infrared Array Camera on board the Spitzer Space Telescope as part of Spitzer's extended warm mission. We find secondary eclipse depths of 0.319% {+-} 0.031% and 0.343% {+-} 0.027% for the 3.6 and 4.5 {mu}m bands, respectively, and show model emission spectra and pressure-temperature profiles for the planetary atmosphere. These eclipse depths are well fit by model emission spectra with water and other molecules in absorption, similar to those used for TrES-3 and HD 189733b. Depending on our choice of model, these results indicate that this planet has either a weak dayside temperature inversion or no inversion at all. The absence of a strong thermal inversion on this highly irradiated planet is contrary to the idea that highly irradiated planets are expected to have inversions, perhaps due the presence of an unknown absorber in the upper atmosphere. This result might be explained by the modestly enhanced activity level of WASP-4b's G7V host star, which could increase the amount of UV flux received by the planet, therefore reducing the abundance of the unknown stratospheric absorber in the planetary atmosphere as suggested in Knutson et al. We also find no evidence for an offset in the timing of the secondary eclipse and place a 2{sigma} upper limit on |ecos {omega}| of 0.0024, which constrains the range of tidal heating models that could explain this planet's inflated radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster - 17: Characterization and correction of radiation induced background in scanning water tanks

Purpose: To characterize and correct for radiation-induced background (RIB) observed in the signals from a class of scanning water tanks. Methods: A method was developed to isolate the RIB through detector measurements in the background-free linac console area. Variation of the RIB against a large number of parameters was characterized, and its impact on basic clinical data for photon and electron beams was quantified. Different methods to minimize and/or correct for the RIB were proposed and evaluated. Results: The RIB is due to the presence of the electrometer and connection box in a low background radiation field (by design). The absolute RIB current with a biased detector is up to 2 pA, independent of the detector size, which is 0.6% and 1.5% of the central axis reference signal for a standard and a mini scanning chamber, respectively. The RIB monotonically increases with field size, is three times smaller for detectors that do not require a bias (e.g., diodes), is up to 80% larger for positive (versus negative) polarity, decreases with increasing photon energy, exhibits a single curve versus dose rate at the electrometer location, and is negligible for electron beams. Data after the proposed field-size correction method agree with point measurements from an independent system to within a few tenth of a percent for output factor, head scatter, depth dose at depth, and out-of-field profile dose. Manufacturer recommendations for electrometer placement are insufficient and sometimes incorrect. Conclusions: RIB in scanning water tanks can have a non-negligible effect on dosimetric data.

60 APPLIED LIFE SCIENCES↗

DISTORTED CYCLOTRON LINE PROFILE IN CEP X-4 AS OBSERVED BY NuSTAR

We present spectral analysis of Nuclear Spectroscopic Telescope Array and Swift observations of Cep X-4 during its outburst in 2014. We observed the source once during the peak of the outburst and once during the decay, finding good agreement in the spectral shape between the observations. We describe the continuum using a power law with a Fermi–Dirac cutoff at high energies. Cep X-4 has a very strong cyclotron resonant scattering feature (CRSF) around 30 keV. A simple absorption-like line with a Gaussian optical depth or a pseudo-Lorentzian profile both fail to describe the shape of the CRSF accurately, leaving significant deviations at the red side of the line. We characterize this asymmetry with a second absorption feature around 19 keV. The line energy of the CRSF, which is not influenced by the addition of this feature, shows a small but significant positive luminosity dependence. With luminosities between (1–6) × 10{sup 36} erg s{sup −1}, Cep X-4 is below the theoretical limit where such a correlation is expected. This behavior is similar to Vela X-1 and we discuss parallels between the two systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Fine Root and Soil Organic Carbon Depth Distributions are Inversely Related Across Fertility and Rainfall Gradients in Lowland Tropical Forests

Humid tropical forests contain some of the largest soil organic carbon (SOC) stocks on Earth. Much of this SOC is in subsoil, yet variation in the distribution of SOC through the soil profile remains poorly characterized across tropical forests. We used a correlative approach to quantify relationships among depth distributions of SOC, fine root biomass, nutrients and texture to 1 m depths across 43 lowland tropical forests in Panama. The sites span rainfall and soil fertility gradients, and these are largely uncorrelated for these sites. We used fitted b parameters to characterize depth distributions, where b is a numerical index based on an asymptotic relationship, such that larger b values indicate greater concentrations of root biomass or SOC at depth in the profile. Root b values ranged from 0.82 to 0.95 and were best predicted by soil pH and extractable potassium (K) stocks. For example, the three most acidic (pH < 4) and Kpoor (< 20 g K m -2 ) soils contained 76 ± 5% of fine root biomass from 0 to 10 cm depth, while the three least acidic (pH > 6.0) and most K-rich (> 50 g K m -2 ) soils contained only 41 ± 9% of fine root biomass at this depth. Root b and SOC b values were inversely related, such that a large fine root biomass in surface soils corresponded to large SOC stocks in subsoils (50–100 cm). SOC b values were best predicted by soil pH and base cation stocks, with the three most base-poor soils containing 34 ± 8% of SOC from 50 to 100 cm depth, and the three most base-rich soils containing just 9 ± 2% of SOC at this depth. Nutrient depth distributions were not related to Root b or SOC b values. Here, these data show that large surface root biomass stocks are associated with large subsoil C stocks in strongly weathered tropical soils. Further studies are required to evaluate why this occurs, and whether changes in surface root biomass, as may occur with global change, could in turn influence SOC storage in tropical forest subsoils.

54 ENVIRONMENTAL SCIENCES↗

An inductively heated hot cavity catcher laser ion source

An inductively heated hot cavity catcher has been constructed for the production of low-energy ion beams of exotic, neutron-deficient Ag isotopes. A proof-of-principle experiment has been realized by implanting primary {sup 107}Ag{sup 21+} ions from a heavy-ion cyclotron into a graphite catcher. A variable-thickness nickel foil was used to degrade the energy of the primary beam in order to mimic the implantation depth expected from the heavy-ion fusion-evaporation recoils of N = Z {sup 94}Ag. Following implantation, the silver atoms diffused out of the graphite and effused into the catcher cavity and transfer tube, where they were resonantly laser ionized using a three-step excitation and ionization scheme. Following mass separation, the ions were identified by scanning the frequency of the first resonant excitation step while recording the ion count rate. Ion release time profiles were measured for different implantation depths and cavity temperatures with the mean delay time varying from 10 to 600 ms. In addition, the diffusion coefficients for silver in graphite were measured for temperatures of 1470 K, 1630 K, and 1720 K, from which an activation energy of 3.2 ± 0.3 eV could be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗