Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Thermal Runaway Risk Evaluation of Li-Ion Cells Using a Pinch-Torsion Test

Internal short circuit (ISCr) can lead to failure of Li-ion cells and sometimes result in thermal runaway. Understanding the behavior of Li-ion cells in ISCr condition is thus critical to evaluate the safety of these energy storage devices. In the current work, a pinch-torsion test is developed to simulate ISCr in a controlled manner. It is demonstrated that the torsional component superimposed on compression loading can reduce the axial load required to induce ISCr with smaller short spot size. Using this pinch-torsion test, two commercial Li-ion pouch cells were tested under different state of charge (SOC). Based on the severity of the cell damage, a series of thermal runaway risk scores were used to rate the thermal stability of these cells. One of the cell types showed significantly increased hazard as the SOC increased while the other type exhibited relative uniform behavior among different SOC. Therefore this novel pinch-torsion test seems to be an attractive candidate for safety testing of Li-ion cells due to its abilities to consistently create small ISCr spots and to differentiate cell stability in a wide range of SOC.

internal short circuit↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrotron X-ray tests of an L-shaped laterally graded multilayer mirror for the analyzer system of the ultra-high-resolution IXS spectrometer at NSLS-II

Characterization and testing of an L-shaped laterally graded multilayer mirror are presented. This mirror is designed as a two-dimensional collimating optics for the analyzer system of the ultra-high-resolution inelastic X-ray scattering (IXS) spectrometer at National Synchrotron Light Source II (NSLS-II). The characterization includes point-to-point reflectivity measurements, lattice parameter determination and mirror metrology (figure, slope error and roughness). Here, the synchrotron X-ray test of the mirror was carried out reversely as a focusing device. The results show that the L-shaped laterally graded multilayer mirror is suitable to be used, with high efficiency, for the analyzer system of the IXS spectrometer at NSLS-II.

36 MATERIALS SCIENCE↗

Testing Fluorescence Lifetime Standards using Two-Photon Excitation and Time-Domain Instrumentation: Fluorescein, Quinine Sulfate and Green Fluorescent Protein

It is essential for everyone working with experimental science to be certain that their instruments produce reliable results, and for fluorescence lifetime experiments, information about fluorescence lifetime standards is crucial. A large part of the literature on lifetime standards dates back to the 1970s and 1980s, and the use of newer and faster measuring devices may deem these results unreliable. We have tested the three commonly used fluorophores fluorescein, quinine sulfate and green fluorescent protein for their suitability to serve as lifetime standards, especially to be used with two-photon excitation measurements in the time-domain. We measured absorption and emission spectra for the fluorophores to determine optimal wavelengths to use for excitation and detector settings. Fluorescence lifetimes were measured for different concentrations, ranging from 10{sup − 3} − 10{sup − 5} M, as well as for various solvents. Fluorescein was soluble in both ethanol, methanol and sulfuric acid, while quinine sulfate was only soluble in sulfuric acid. Green fluorescent protein was prepared in a commercial Tris-HCl, EDTA solution, and all three fluorophores produced stable lifetime results with low uncertainties. No siginificant variation with concentration was measured for any of the fluorophores, and all showed single-exponential decays. All lifetime measurements were carried out using two-photon excitation and lifetime data was obtained in the time-domain using time-correlated single-photon counting.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of Electronic Stress-Induced Changes in Multilayer MoS 2

Transition metal dichalcogenides like molybdenum disulfide (MoS 2 ) are compelling for next-generation electronic devices. In this work, we investigate the impact of electronic stress on MoS 2 to illustrate that observational and phenomenological information on multiple devices can be useful to describe changes in the device, and caution against the rationalization of paltry results as representative or correlative to device behavior. Here, we stress MoS 2 by applying a sustained 20 V DC bias to study the material’s response. Post-stress electronic characterization revealed nonuniform shifts in current–voltage (I–V) behavior alongside microscale changes. Complementary mechanical, spectroscopic, and scanning microwave impedance measurements showed that stress-induced features locally modulate stiffness, surface potential, Raman intensity, and charge carrier density. We correlated I–V behavior with morphological features (wrinkles, tears, folds, height) and device-level geometry (MoS 2 overlap with electrodes, channel area, contact length) on 50 test structures across five chips to move beyond anecdotal conclusions. We found no universal correlations before DC stress. However, device-level geometry was correlated with I–V behavior after DC stress, suggesting that electrode contacts play a more dominant role than morphology in determining performance. Delamination and thinning induced by DC stress led to localized reductions in charge carrier density within the affected regions. Further, delamination and thinning appear to map to I–V device performance in a few samples, but the correlation is lost when a larger sample size is considered. This suggests significant sample-to-sample variability in surface electronic states of the test structures. We also discuss how environmental factors introduced during fabrication may contribute to the observed heterogeneous device response. Progress will require high-resolution, multimodal analysis across many samples constructed under controlled, clean conditions. By building data sets that capture variability, we can better identify the true drivers of performance.

36 MATERIALS SCIENCE↗

Natural Gas Drilling near the Underground Nuclear Test Site of Rulison, Colorado - 19571

In 1969, the Project Rulison test was conducted in western Colorado using a nuclear device to stimulate natural gas production by fracturing low-permeability, gas-bearing rock. The presence of radionuclides (specifically tritium) in the produced gas persisted above acceptable levels, and the test was abandoned. Advances in hydrofracturing technology over the past 10-15 years have revolutionized the extraction of hydrocarbons from low-permeability formations, leading to a significant increase of drilling in the Rulison area. Drilling activity nearing the Rulison site has raised concerns that remnant radioactivity might be encountered. The site, now under the care of the US Department of Energy (DOE), is protected by a 16-hectare (40 acre) institutional control boundary (Lot 11) that prohibits drilling or extraction of materials below 1830 meters (6000 feet) within the lot boundary. Drilling within 0.8 kilometer (0.5 mile) of the site requires a hearing before the Colorado Oil and Gas Conservation Commission. DOE recommends that gas developers adopt a conservative, staged drilling approach, allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. The staged approach calls for collecting data from wells away from the site before drilling closer. For instance, the wells 1.2 kilometer (0.75 mile) west of the site did not encounter any unexpected geologic conditions and now have 8 years of production without encountering any detonation-related radionuclides. The next set of wells would be 0.8 kilometer (0.5 mile) west of the site. This sequential method drills first at locations with a low probability of encountering contamination and then moves closer. This process protects public safety while allowing the collection of additional data to confirm that contamination has not migrated beyond the 16-hectare (40-acre) institutional control boundary. The staged drilling approach was simulated with a modeling effort that estimates the current extent of contamination and the potential for production-induced contaminant migration to nearby wells. The model incorporates geologic data from nearby wells and was calibrated to production data from both the reentry well production testing (1970-1971) and the wells 1.2 kilometer (0.75 mile) from the site that began producing in 2010. The geologic data include both sand/shale distribution statistics as well as the tendency of hydrofractures to preferentially propagate east and west due to the regional stress field. The model results indicate that it is unlikely that wells near the site would ever encounter site-related radionuclides. (authors)

03 NATURAL GAS↗

An in-depth field validation of “DUSST”: A novel low-maintenance soiling measurement device

This study presents indoor and field validation results for two versions of the “DUSST” optical soiling sensor, intended to be a low-cost and low-maintenance device for measuring photovoltaic soiling losses. Indoor testing covers irradiance calibration and temperature dependencies, which are necessary to achieve high accuracy, low uncertainty field measurements. Field testing includes an array of different environments including Saudi Arabia, California, Utah, and Colorado. DUSST versions include a configuration with a 530-nm light emitting diode (LED) (discussed in previous work) and a unit with seven white LEDs and a polycarbonate collimating optic. The new design increases light intensity fivefold and demonstrates a single linear calibration coefficient is effective to measure soiling losses as high as 75%. Field data from Utah and California demonstrate that daily soiling loss measurements and soiling rate calculations closely match both reference cell and full-size module measurements of soiling losses and soiling rates. Corrective methods employed on the Utah DUSST sensor suggest that it is possible to achieve measurement errors as low as ±0.1% at two standard deviations. Field data from both Colorado and Saudi Arabia demonstrate that LED lens soiling can occur and that further design optimizations are needed. The lesson learned from all the field deployment locations suggests directions for future design improvements.

14 SOLAR ENERGY↗

Problems of Developing Solid Mineral Deposits on the Sea and Ocean Floor

Brief characteristics of the mineral raw material potential of the deep-sea deposits of ferromanganese nodules in the area of the Clarion-Clipperton Zone leased by Russia in the Pacific Ocean are presented. The creation at the Moscow Mining Institute (MGI) of the USSR’s first Scientific and Technical Problems Laboratory and the results of its work on extraction of minerals from the sea and ocean floor are reviewed. The research works carried out by MGI on underwater mining of ilmenite-rutile-zirconium sands on the Baltic Sea shelf and Iturup Island and tin under conditions of northern seas and the development of the technogenic placer of the East Siberian Sea are analyzed. The concept of using the kinetic energy of coaxially swirled fluid jets in hydrotransport-hoisting devices of vortex slurry preparation, which was tested in the Black Sea and an air-lift mud intake by mechanical and hydraulic loosening for extracting diamond-containing gravel-pebble rocks on the Namibia shelf is given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS↗

An International Round-Robin Study on Thermoelectric Module Testing and Development of Standard Power Generation Modules

An international round-robin study on thermoelectric power generation modules was conducted with nine participating laboratories. Two types of commercially available bismuth telluride modules, 30 mm × 30 mm and 40 mm × 40 mm, were used. A test protocol was followed with five temperature set points from 50°C to 150°C. Graphite sheets were used as thermal interface materials with test pressure at 100 psi (0.69 MPa). The results showed large lab-to-lab variations and the key source of uncertainty for module efficiency was identified as the heat flux measurement. In the meantime, significant uncertainty was also found in maximum electrical power (P max ) measurements. As a result of the round-robin, a “standard module” with 4 × 4 legs on a 20 mm × 20 mm platform was suggested. A skutterudite module and a half-Heusler module were produced with identical geometry and 4 mm × 4 mm × 8 mm legs. All transport properties to calculate the figure-of-merit, zT, were measured from ambient temperature to 500°C. Module performance was measured by two laboratories. Two finite-element-analysis (FEA)-based models were developed independently to simulate and predict the module performance. In conclusion, the standard modules eliminated significant test uncertainties and are aimed at assisting device design and achieving more accurate performance predictions.

Round-robin↗

Options and uncertainties in planetary defense: Impulse-dependent response and the physical properties of asteroids

In this paper we discuss that though rare, asteroid impacts are inevitable, and with the current state of technology, kinetic impactors are the preferred but not the complete solution. If the time to impact is short, or the threatening body too large, nuclear deflection serves as a final option. This work is part of an integrated study by National Aeronautics and Space Administration (NASA) and the National Nuclear Security Administration (NNSA) to better determine the relative efficacy of these complimentary approaches. In particular, we examine the important material properties that affect each approach, to improve critical characterization efforts, and reduce uncertainty in the limits of the impactor technology. Impact speeds for kinetic impactors on Near-Earth Object (NEO) intercept trajectories commonly range from 5 to 20 km/s, resulting in significant crater ejecta and a momentum enhancement above that carried by the impactor. This enhancement depends substantially on the strength and porosity of the asteroid, as well as the impact speed. Here simulations from different codes are presented, along with constraints from experimental measurements. The uncertainties due to ignorance of the strength and porosity of the impact point are significant in determining the limits of impactor sufficiency. The nuclear approach is considered within the context of current capabilities, posing no need to test, as extant and well-understood devices are sufficient for the largest known Potentially Hazardous Objects (PHOs). Results of x-ray sources with realistic spectra as well as blackbody spectra are given, along with some assessment on composition dependence.

79 ASTRONOMY AND ASTROPHYSICS↗

Quality Assurance Needs for Modern Image-Based Radiotherapy: Recommendations From 2007 Interorganizational Symposium on 'Quality Assurance of Radiation Therapy: Challenges of Advanced Technology'

This report summarizes the consensus findings and recommendations emerging from 2007 Symposium, 'Quality Assurance of Radiation Therapy: Challenges of Advanced Technology.' The Symposium was held in Dallas February 20-22, 2007. The 3-day program, which was sponsored jointly by the American Society for Therapeutic Radiology and Oncology (ASTRO), American Association of Physicists in Medicine (AAPM), and National Cancer Institute (NCI), included >40 invited speakers from the radiation oncology and industrial engineering/human factor communities and attracted nearly 350 attendees, mostly medical physicists. A summary of the major findings follows. The current process of developing consensus recommendations for prescriptive quality assurance (QA) tests remains valid for many of the devices and software systems used in modern radiotherapy (RT), although for some technologies, QA guidance is incomplete or out of date. The current approach to QA does not seem feasible for image-based planning, image-guided therapies, or computer-controlled therapy. In these areas, additional scientific investigation and innovative approaches are needed to manage risk and mitigate errors, including a better balance between mitigating the risk of catastrophic error and maintaining treatment quality, complimenting the current device-centered QA perspective by a more process-centered approach, and broadening community participation in QA guidance formulation and implementation. Industrial engineers and human factor experts can make significant contributions toward advancing a broader, more process-oriented, risk-based formulation of RT QA. Healthcare administrators need to appropriately increase personnel and ancillary equipment resources, as well as capital resources, when new advanced technology RT modalities are implemented. The pace of formalizing clinical physics training must rapidly increase to provide an adequately trained physics workforce for advanced technology RT. The specific recommendations of the Symposium included the following. First, the AAPM, in cooperation with other advisory bodies, should undertake a systematic program to update conventional QA guidance using available risk-assessment methods. Second, the AAPM advanced technology RT Task Groups should better balance clinical process vs. device operation aspects-encouraging greater levels of multidisciplinary participation such as industrial engineering consultants and use-risk assessment and process-flow techniques. Third, ASTRO should form a multidisciplinary subcommittee, consisting of physician, physicist, vendor, and industrial engineering representatives, to better address modern RT quality management and QA needs. Finally, government and private entities committed to improved healthcare quality and safety should support research directed toward addressing QA problems in image-guided therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved liquid lithium surfaces in the Lithium Tokamak Experiment-β

Advances in vacuum, surface, and lithium conditioning techniques throughout five years of continuous operations in LTX-β have produced mirror-like liquid lithium surfaces and demonstrated the feasibility of high-performance tokamak discharges fully surrounded by liquid metal without significant operational problems. Improvements in conditioning techniques and procedures, including many weeks of baking and accumulation of 70 g of Li, led to reduced residual gasses and clean Li surfaces - all while still maintaining enough operational flexibility for multiple in-vacuum diagnostic upgrades and calibrations. Coatings had a visibly clean appearance, with reflective liquid metal demonstrating good wetting and surface adhesion with films that were now macroscopically thick. Solidified Li showed large crystal grains, while surface science measurements observed reduced impurities in the lithium. Steadily improved plasma performance was achieved with liquid lithium, with discharges able to match solid Li in terms of evolution of I p and n e , including rapid density pumping indicating low recycling. There were indications of moderately increased Li impurity influx, though few significant disturbances by the large liquid surfaces on tokamak operations over hundreds of discharges. Liquid metal plasma facing components are a potential solution to the extreme heat and particle fluxes that could cause unacceptable damage to solid materials, while liquid lithium also has the potential for greatly increased confinement in the low-recycling regime. While many liquid metal approaches are possible, and numerous experiments have been conducted in test stands and small modules in fusion devices, LTX-β is the only tokamak operated while fully surrounded by liquid metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interfacial stabilization for inverted perovskite solar cells with long-term stability

Perovskite solar cells (PSCs) commonly exhibit significant performance degradation due to ion migration through the top charge transport layer and ultimately metal electrode corrosion. Here, we demonstrate an interfacial management strategy using a boron chloride subphthalocyanine (Cl 6 SubPc)/fullerene electron-transport layer, which not only passivates the interfacial defects in the perovskite, but also suppresses halide diffusion as evidenced by multiple techniques, including visual element mapping by electron energy loss spectroscopy. As a result, we obtain inverted PSCs with an efficiency of 22.0% (21.3% certified), shelf life of 7000 h, Τ 80 of 816 h under damp heat stress (compared to less than 20 h without Cl 6 SubPc), and initial performance retention of 98% after 2000 h at 80 °C in inert environment, 90% after 2034 h of illumination and maximum power point tracking in ambient for encapsulated devices and 95% after 1272 h outdoor testing ISOS-O-1. Our strategy and results pave a new way to move PSCs forward to their potential commercialization solidly.

14 SOLAR ENERGY↗

Nicotine Monitoring with a Wearable Sweat Band

The tobacco epidemic is a public health threat that has taken a heavy toll of lives around the globe each year. Smoking affects both the smokers and those who are exposed to secondhand smoke, and careful tracking of exposure can be key to mitigating the potential hazards. For smokers, the variation of chemical compositions between commercial cigarettes has led to ambiguity in estimating the health risks, both for active smokers and others involuntarily exposed to tobacco smoke and byproducts. In this regard, sweat possesses an attractive opportunity to monitor smoke exposure due to sweat's abundance in biomolecules and its great accessibility. In this paper, we present a wearable sweat band to monitor nicotine, a prominent ingredient in cigarettes, as a viable way to quantitatively assess a wearer's exposure to smoking. Both smokers and normal subjects are tested to demonstrate the use of this device for smoke-related health monitoring. Our results exhibit confirmable and elevated nicotine levels in sweat for subjects inhaling cigarette smoke. This continuous and personalized sweat sensing device is leverage to monitor smoke pollution for a potentially broad population.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Microwave Preparation of Highly Efficient Ce[superscript 3+]-Substituted Garnet Phosphors for Solid State White Lighting

Ce{sup 3+}-substituted aluminum garnet compounds of yttrium (Y{sub 3}Al{sub 5}O{sub 12}) and lutetium (Lu{sub 3}Al{sub 5}O{sub 12}) - both important compounds in the generation of (In,Ga)N-based solid state white lighting - have been prepared using a simple microwave heating technique involving the use of a microwave susceptor to provide the initial heat source. Carbon used as the susceptor additionally creates a reducing atmosphere around the sample that helps stabilize the desired luminescent compound. High quality, phase-pure materials are prepared within a fraction of the time and using a fraction of the energy required in a conventional ceramic preparation; the microwave technique allows for a reduction of about 95% in preparation time, making it possible to obtain phase pure, Ce{sup 3+}-substituted garnet compounds in under 20 min of reaction time. It is estimated that the overall reduction in energy compared with ceramic routes as practiced in the lab is close to 99%. Conventionally prepared material is compared with material prepared using microwave heating in terms of structure, morphology, and optical properties, including quantum yield and thermal quenching of luminescence. Finally, the microwave-prepared compounds have been incorporated into light-emitting diode 'caps' to test their performance characteristics in a real device, in terms of their photon efficiency and color coordinates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-term non-invasive interrogation of human dorsal root ganglion neuronal cultures on an integrated microfluidic multielectrode array platform

Scientific studies in drug development and toxicology rely heavily on animal models, which often inaccurately predict the true response for human exposure. This may lead to unanticipated adverse effects or misidentified risks that result in, for example, drug candidate elimination. The utilization of human cells and tissues for in vitro physiological platforms has become a growing area of interest to bridge this gap and to more accurately predict human responses to drugs and toxins. The effects of new drugs and toxins on the peripheral nervous system are often investigated with neurons isolated from dorsal root ganglia (DRG), typically with one-time measurement techniques such as patch clamping. Here, we report the use of our multi-electrode array (MEA) platform for long-term noninvasive assessment of human DRG cell health and function. In this study, we acquired simultaneous optical and electrophysiological measurements from primary human DRG neurons upon chemical stimulation repeatedly through day in vitro (DIV) 23. Distinct chemical signatures were noted for the cellular responses evoked by each chemical stimulus. Additionally, the cell viability and function of the human DRG neurons were consistent through DIV 23. To the best of our knowledge, this is the first report on long-term measurements of the cell health and function of human DRG neurons on a MEA platform. Future generations will include higher electrode numbers in customized arrangements as well as integration with different tissue types on a single device. This platform will provide a valuable testing tool for both rodent and human cells, enabling a more comprehensive risk assessment for drug candidates and toxicants.

59 BASIC BIOLOGICAL SCIENCES↗