Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

University of California, San Diego (UCSD) Sky Imager Cloud Position Study Field Campaign Report

During the University of California, San Diego (UCSD) Sky Imager Cloud Position Study, two University of California, San Diego Sky Imagers (USI) (Figure 1) were deployed the U.S. Department of Energy(DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains SGP) research facility. The UCSD Sky Imagers were placed 1.7 km apart to allow for stereographic determination of the cloud height for clouds over approximately 1.5 km. Images with a 180-degree field of view were captured from both systems during daylight hours every 30 seconds beginning on March 11, 2013 and ending on November 4, 2013. The spatial resolution of the images was 1,748 × 1,748, and the intensity resolution was 16 bits using a high-dynamic-range capture process. The cameras use a fisheye lens, so the images are distorted following an equisolid angle projection.

58 GEOSCIENCES↗

USGS VDP Infrasound Sensor Evaluation

Sandia National Laboratories has tested and evaluated two infrasound sensors, the model VDP100 and VDP250, built in-house at the USGS Cascades Volcano Observatory. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, self-noise, dynamic range and nominal transfer function. Notable features of the VDP sensors include novel and durable construction and compact size.

47 OTHER INSTRUMENTATION↗

Raman Lidar MERGE Value-Added Product

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility Raman lidars (RLs) are semi-autonomous, land-based, laser remote sensing systems that provide height- and time-resolved measurements of water vapor mixing ratio, temperature, aerosol backscatter, extinction, and linear depolarization ratio from about 200 m to greater than 10 km AGL. These systems transmit at a wavelength of 355 nm with 300 mJ, ~5 ns pulses, and a pulse repetition frequency of 30 Hz. The receiver incorporates nine detection channels, including two water vapor channels at 408 nm, two nitrogen channels at 387 nm, three elastic channels, and two rotational Raman channels for temperature profiling at 354 and 353 nm. Figure 1 illustrates the layout of the ARM RL receiver system. Backscattered light from the atmosphere enters the telescope and is directed into the receiver system (i.e., aft optics). This signal is then split between a narrow-field-of-view radiometer (NFOV) path (blue) and a wide-field-of-view zenith radiometer (WFOV) path (red). The WFOV (2 mrad) path contains three channels (water vapor, nitrogen, and unpolarized elastic), and the NFOV (0.3 mrad) path contains six channels (water vapor, nitrogen, parallel and perpendicular elastic, and two rotational Raman). All nine detection channels use Electron Tubes 9954B photomultiplier tubes (PMTs). The signals from each of the nine PMTs are acquired using transient data recorders from Licel GbR (Berlin, Germany). The Licel data recorders provide simultaneous measurements of both analog photomultiplier current and photon counts at height resolution of 7.5 m and a time resolution of 10 s. The analog signal provides good linearity in the strong signal regime, but poor sensitivity at low signal levels. Conversely, the photo counting signal provides good sensitivity in the weak signal regime, but is strongly nonlinear at higher signal levels. The advantage in recording both signals is that they can be combined (or merged) into a single signal with improved dynamic range. The process of combining the analog and photon counting data has become known as “gluing” (Whiteman et al., 2006).

47 OTHER INSTRUMENTATION↗

CEA SMAD 2016 Digitizer Evaluation.

Sandia National Laboratories has tested and evaluated an updated SMAD digitizer, developed by the French Alternative Energies and Atomic Energy Commission (CEA). The SMAD digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The SMAD digitizers have been updated since their last evaluation by Sandia to improve their performance when recording at a sample rate of 20 Hz for infrasound applications and 100 Hz for hydro-acoustic seismic stations. This evaluation focuses primarily on the 20 Hz and 100 Hz sample rates. The SMAD digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test- Ban-Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Two Guralp Preamplifiers for GS13 Seismometer Application.

Sandia National Laboratories has tested and evaluated a new preamplifier, the Guralp Preamplifier for GS13, manufactured by Guralp. These preamplifiers are used to interface between Guralp digitizers and Geotech GS13 Seismometers. The purpose of the preamplifier evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Guralp GS13 Preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Nanometrics T120PH Seismometer Evaluation

Sandia National Laboratories has tested and evaluated three seismometers, the Trillium 120PH, manufactured by Nanometrics. These seismometers measure broadband ground velocity using a UVW configuration with feedback control in a mechanically levelled borehole package. The purpose of the seismometer evaluation was to determine a measured sensitivity, response, self- noise, dynamic range, and self-calibration ability. The Nanometrics Trillium 120PH seismometers are being evaluated for the U.S. Air Force as part of their Next Generation Qualification effort.

47 OTHER INSTRUMENTATION↗

Quantum Control of Spins in Diamond for Nanoscale Magnetic Sensing and Imaging

Our research activities during the grant period focused on the challenges of highly accurate and precise magnetometry and magnetic imaging using quantum spins inside diamond. Our work has resulted in 6 papers published in peer-reviewed journals, with two more currently under consideration by referees. We showed that through the use of novel phase estimation algorithms inspired by quantum information science we can carry out accurate and high dynamic range DC magnetometry as well as lock-in detection of oscillating (AC) magnetic fields. We investigated the geometric phase as a route to higher precision quantum information and magnetic sensing applications, and probed the experimental limits to the fidelity of such geometric phase gates. We also demonstrated that there is a spin dependent signal in the charge state flipping of the NV defect center in diamond, which could potentialy be useful for higher fidelity spin readout at room temperature. Some of these projects have now led to further investigation in our lab on multi-photon spectroscopy (manuscript in preparation), and plasmonic guiding of light in metal nanowires (manuscript available on arxiv). In addition, several invited talks were given by the PI, and conference presentations were given by the graduate students and postdocs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Next Generation Qualification: Kinemetrics STS-5A Seismometer Evaluation

Sandia National Laboratories has tested and evaluated two seismometers, the STS-5A, manufactured by Kinemetrics. These seismometers measure three axes of broadband ground velocity using a UVW configuration with feedback control in a mechanically levelled borehole package. The purpose of the seismometer evaluation was to determine a measured sensitivity, response, self-noise, dynamic range, and self-calibration ability. The Kinemetrics STS-5A seismometers are being evaluated for the U.S. Air Force as part of their Next Generation Qualification effort.

47 OTHER INSTRUMENTATION↗

Miniature CCD X-Ray Imaging Camera Technology Final Report CRADA No. TC-773-94

The goal of the project was to develop a compact, large active area, high spatial resolution, high dynamic range, charge-coupled device (CCD) camera to replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating X-rays. The camera head and controller needed to be capable of operation within a vacuum environment and small enough to be fielded within the small vacuum target chambers at LLNL.

42 ENGINEERING↗

Notes on the design of experiments and beam diagnostics with synchrotron light detected by a gated photomultiplier for the Fermilab superconducting electron linac and for the Integrable Optics Test Accelerator (IOTA)

We outline the design of beam experiments for the electron linac at the Fermilab Accelerator Science and Technology (FAST) facility and for the Integrable Optics Test Accelerator (IOTA), based on synchrotron light emitted by the electrons in bend dipoles, detected with gated microchannel-plate photomultipliers (MCP-PMTs). The system can be used both for beam diagnostics (e.g., beam intensity with full dynamic range, turn-by-turn beam vibrations, etc.) and for scientific experiments, such as the direct observation of the time structure of the radiation emitted by single electrons in a storage ring. The similarity between photon pulses and spectrum at the downstream end of the electron linac and in the IOTA ring allows one to test the apparatus during commissioning of the linac.

43 PARTICLE ACCELERATORS↗

2017 Guralp Affinity Digitizer Evaluation.

Sandia National Laboratories has tested and evaluated two Guralp Affinity digitizers. The Affinity digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self- noise, dynamic range, system noise, response, passband, and timing. The Affinity digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Chaparral Model 60 Infrasound Sensor Evaluation.

Sandia National Laboratories has tested and evaluated an infrasound sensor, the Model 60 manufactured by Chaparral Physics, a Division of Geophysical Institute of the University of Alaska, Fairbanks. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, dynamic range, and seismic sensitivity. The Model 60 infrasound sensor is a new sensor developed by Chaparral Physics intended to be a small, rugged sensor used in more flexible application conditions.

47 OTHER INSTRUMENTATION↗

DITAC FASPAX / ASIC Development [Slides]

FASPAX is an integrating detector with wide dynamic range and high burst frame rate. The detector uses in-pixel analog storage to acquire a burst of images at frame rates of up to 13 MHz, with further provision for user-defined timing schemes. The detector allows the synchrotron light source time-resolved community to access the machine's designed temporal resolution for particular fill patterns.

43 PARTICLE ACCELERATORS↗

Next Generation Qualification: Guralp Systems Affinity Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems Ltd. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Affinity digitizer is Guralp's latest release in their digitizer product line. The Affinity is available with either 4 or 8 channels at 24 bit resolution. In addition to the 24 bit channels, 16 multiplexed low resolution channels are provided. Other features include the means to accept multiple types of timing sources (e.g. GPS, NTP and PTP) and a web page interface for command and control of the unit.

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Quanterra Q330HR Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330HR, manufactured by Quanterra. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Q330HR is Quanterra’s improved Q330 datalogger with a 26 bits of resolution on channels 1-3 and a 24 bits of resolution on channels 4-6 (26 bit is optional). The Quanterra Q330HR is being evaluated for potential use U.S. Air Force seismic monitoring systems as part of their Next Generation Qualification effort.

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Nanometrics Centaur Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Centaur, manufactured by Nanometrics. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Centaur digitizer is Nanometrics’ replacement for their Taurus digitizer and marks Nanometrics first 6 channel, 24 bit resolution system. Other improvements include LED status indicators on the top of the unit, providing basic status of the core systems of a seismic station (e.g. timing, sensor SOH, storage, etc), an optional wifi system allowing password protected access to the unit and a web interface for monitoring and configuration of the unit. The Nanometrics Centaur is being evaluated for potential use U.S. Air Force seismic monitoring systems as part of their Next Generation Qualification effort.

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Geotech Instruments SMART24B Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a digitizer, the SMART24B, manufactured by Geotech Instruments, LLC. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The SMART24B is Geotech's datalogger intended for borehole deployment in their digitizer product line. The SMART24B is available with either 3 or 6 channels at 24 bit resolution. The digitizer is to be deployed in boreholes, therefore are a minimum number of connections required on the digitizer case as datalogger utilizes a distribution panel, mounted up-hole, serving to breakout power, GPS, serial communications and ethernet connections.

47 OTHER INSTRUMENTATION↗

A review of various methods of detecting and measuring beam halos

Halos in high energy particle beams require constant monitoring to minimise beam losses and damage to accelerator components. Four methods of measuring halos are described: wire scanner, laser wire scanner, diamond detector and halo masking monitors. Details of their effectiveness’ from tests at various accelerators are used to evaluate how useful they are. It is found that methods making use of wire and laser wire scanners are unable to achieve a high enough dynamic range to measure the outer halo, where the intensity of particles is very low. Diamond detectors can be used to determine the presence of a halo, but are unable to reconstruct their shape. The halo masking method, which makes use of a digital micromirror device to block out high intensity light, produces very good results, but it is possible that light is scattered inside the phosphor screen used to produce an image from the beam, skewing the measurements.

43 PARTICLE ACCELERATORS↗