Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

HAWAII QUASAR AND T DWARF SURVEY. I. METHOD AND DISCOVERY OF FAINT FIELD ULTRACOOL DWARFS ,

The Hawaii Quasar and T dwarf survey (HQT Survey) is a wide-field, red optical survey carried out with the Suprime-Cam mosaic CCD camera on the 8.2 m Subaru telescope. The HQT survey is designed to search for low-luminosity (M{sub AB1450} < -23) quasars at high redshift (z>5.7) as well as T dwarfs, both of which are selected by their very red I - z' colors. We use an optical narrowband filter NB816 to break a well-known I - z' color degeneracy between high-z quasars and foreground M and L dwarfs, which are more numerous than quasars. This paper is the first in a series of papers from the HQT survey and we report on the discovery of six faint (19 {<=} J {<=} 20) ultracool dwarfs found over a {approx}9.3 deg{sup 2} area with a limiting magnitude of z'{sub AB} {<=} 23.3. These dwarfs were confirmed by near-IR imaging and/or spectroscopy conducted at various facilities on Mauna Kea. With estimated distances of 60-170 pc, these are among the most distant spectroscopically confirmed field brown dwarfs to date. Limits on the proper motions of these ultracool dwarfs suggest that they are old members of the Galactic disk, though future follow-up observations are necessary to minimize errors. Our finding rate of ultracool dwarfs is within model predictions of Liu et al. However, the large brightening amplitude ({approx}1 mag) previously reported for the L/T transition objects appears to overpredict the numbers. We also examine how the survey field latitude affects the survey sensitivity to the vertical scale height of ultracool dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRE-16: VMAT Commissioning and Quality Assurance (QA) of An Elekta Synergy-STM Linac Using ICOM Test HarnessTM

Purpose: To establish a set of tests based on the iCOM software that can be used to commission and perform periodic QA of VMAT delivery on the Elekta Synergy-S, commonly known as the Beam Modulator (BM). Methods: iCOM is used to create and deliver customized treatment fields to characterize the system in terms of 1) MLC positioning accuracy under static and dynamic delivery with full gantry rotation, 2) MLC positioning with known errors, 3) Maximum dose rate, 4) Maximum MLC speed, 5) Maximum gantry speed, 6) Synchronization: gantry speed versus dose rate, and 7) Synchronization: MLC speed versus dose rate. The resulting images were captured on the iView GT and exported in DICOM format to Dosimetry Check™ system for visual and quantitative analysis. For the initial commissioning phase, the system tests described should be supplemented with extensive patient QAs covering all clinically relevant treatment sites. Results: The system performance test suite showed that on our Synergy-S, MLC positioning was accurate under both static and dynamic deliveries. Intentional errors of 1 mm were also easily identified on both static and dynamic picket fence tests. Maximum dose rate was verified with stop watch to be consistently between 475-480 MU/min. Maximum gantry speed and MLC speed were 5.5 degree/s and 2.5 cm/s respectively. After accounting for beam flatness, both synchronization tests, gantry versus dose rate and MLC speed versus dose rate, were successful as the fields were uniform across the strips and there were no obvious cold/hot spots. Conclusion: VMAT commissioning and quality assurance should include machine characterization tests in addition to patient QAs. Elekta iCOM is a valuable tool for the design of customized VMAT field with specific MU, MLC leaf positions, dose rate, and indirect control of MLC and gantry speed at each of its control points.

07 ISOTOPE AND RADIATION SOURCES↗

Distributed Workflows for Modeling Experimental Data

Modeling helps explain the fundamental physics hidden behind experimental data. In the case of material modeling, running one simulation rarely results in output that reproduces the experimental data. Often one or more of the force field parameters are not precisely known and must be optimized for the output to match that of the experiment. Since the simulations require high performance computing (HPC) resources and there are usually many simulations to run, a workflow is very useful to prevent errors and assure that the simulations are identical except for the parameters that need to be varied. These workflows are usually distributed because the simulations require HPC, but the optimization and steps to compare the simulation results and experimental data are done on a local workstation. We will present results from force field refinement of data collected at the Spallation Neutron Source using Kepler, Pegasus, and Beam workflows and discuss what we have learned from using these workflows.

Lynch, Vickie E.↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking

Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID image acquisition at the frame rate of at least 4.29 Hz is recommended. Motion blurring in the images with frame rates below 4.29 Hz can significantly reduce the accuracy of autotracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modelling Curvilinear Beamline Effects on Beam- and Spin-Dynamics in the Fermilab Muon g-2 Storage Ring.

A model of the Fermilab Muon g-2 Experiment storage ring is developed with the BMAD simulation library for beam- and spin-dynamics studies. Particular focus is given to the electrostatic quadrupoles, the plates of which follow the curvature of the particle design trajectory of the magnetically uniform storage ring. To model these, standard electric multipoles and a novel method based on cylindrical harmonics are investigated and found to accurately match the electric field maps produced for the bulk and fringe regions of the curved quadrupoles respectively, despite these methods being specifically for straight beamlines. The toroidal multipole description is then developed, to include curvature and longitudinal field variations (to model the fringe field regions). Various combinations of the different descriptions (including use of the field maps) are used for the bulk and fringe fields of the quadrupoles, and the toroidal multipoles are found to provide the best agreement with the measured tunes of the storage ring. Two integrators are also developed, based on the method of Wu, Forest and Robin. The first of these describes motion in a uniform magnetic dipole field with arbitrary electric field, and produces results comparable to those of the adaptive-step fourth-order Runge–Kutta integrator implemented in BMAD, suitable for tracking over thousands of turns. The second is a generalisation of the first to arbitrary magnetic vector potentials superimposed on that of the uniform dipole, with arbitrary electric fields, and was also found to agree with the Runge–Kutta integrator. Simulations of antimuon storage for 2000 turns of the storage ring were performed, where losses were studied along with the evolution of beam polarisation. The storage losses, important for reducing the systematic error in the measurement of the muon g-2, were found to be largely due to collimator shape. The correlation between momentum and spin precession frequency reflect the effects expected from the electric field correction in the T-BMT equation, on the order of 10 -6 . Particle injection was also studied, for various injection angles, quadrupole strengths and strengths of injection kick, and in the cases where experimental data was provided, the model was found to be consistent with the experiment.

43 PARTICLE ACCELERATORS↗

Rigorous constraints on three-nucleon forces in chiral effective field theory from fast and accurate calculations of few-body observables

We explore the constraints on the three-nucleon force (3NF) of chiral effective field theory (χ EFT) that are provided by bound-state observables in the A = 3 and A = 4 sectors. Our statistically rigorous analysis incorporates experimental error, computational method uncertainty, and the uncertainty due to truncation of the χ EFT expansion at next-to-next-to-leading order. A consistent solution for the 3 H binding energy, the 4 He binding energy and radius, and the 3 H β-decay rate can only be obtained if χ EFT truncation errors are included in the analysis. Here, the β-decay rate is the only one of these that yields a nondegenerate constraint on the 3NF low-energy constants, which makes it crucial for the parameter estimation. We use eigenvector continuation for fast and accurate emulation of no-core shell model calculations of the few-nucleon observables. This facilitates sampling of the posterior probability distribution, allowing us to also determine the distributions of the parameters that quantify the truncation error. We find a χ EFT expansion parameter of Q = 0.33 ± 0.06 for these observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Taylor approximation variance reduction for approximation errors in PDE-constrained Bayesian inverse problems

In numerous applications, surrogate models are used as a replacement for accurate parameter-to-observable mappings when solving large-scale inverse problems governed by partial differential equations (PDEs). The surrogate model may be a computationally cheaper alternative to the accurate parameter-to-observable mappings and/or may ignore additional unknowns or sources of uncertainty. The Bayesian approximation error (BAE) approach provides a means to account for the induced uncertainties and approximation errors, i.e. the errors between the accurate parameter-to-observable mapping and the surrogate. The statistics of these errors are, however, in general unknown a priori, and are thus calculated using Monte Carlo sampling. Although the sampling is typically carried out offline, i.e. before considering the data, the process can still represent a computational bottleneck. In this work, we develop a scalable computational approach for reducing the costs associated with the sampling stage of the BAE approach. Specifically, we consider the Taylor expansion of the accurate and surrogate forward models with respect to the uncertain parameter fields either as a control variate for variance reduction or as a means to directly and efficiently approximate the mean and covariance of the approximation errors. We propose efficient methods for evaluating the expressions for the mean and covariance of the Taylor approximations based on linear(-ized) PDE solves. Furthermore, the proposed approach is independent of the dimension of the uncertain parameter, depending instead on the intrinsic dimension of the data, ensuring scalability to high-dimensional problems. The potential benefits of the proposed approach are demonstrated for two high-dimensional inverse problems governed by PDE examples, namely for the estimation of a distributed Robin boundary coefficient in a linear diffusion problem, and for a coefficient estimation problem governed by a nonlinear diffusion problem.

Bayesian approximation error↗

Corrected loop vertex expansion for Φ{sub 2}{sup 4} theory

This paper is an extended erratum to Rivasseau and Wang [J. Math. Phys. 53, 042302 (2012); e-print http://arxiv.org/abs/1104.3443 [math-ph]], in which the classic construction and Borel summability of the ϕ{sub 2}{sup 4} Euclidean quantum field theory was revisited combining a multi-scale analysis with the constructive method called Loop Vertex Expansion (LVE). Unfortunately we discovered an important error in the method of Rivasseau and Wang [J. Math. Phys. 53, 042302 (2012); e-print http://arxiv.org/abs/1104.3443 [math-ph]]. We explain the mistake, and provide a new, correct construction of the ϕ{sub 2}{sup 4} theory according to the LVE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking

Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the accuracy of auto-tracking. This work is supported in part by the Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Virtual sensing of wind turbine hub loads and drivetrain fatigue damage, Virtuelle Sensoren für die Messung von Hauptwellenlasten und Ermüdungsschäden im Antriebstrang von Windenergieanlagen

Abstract: This paper presents a Digital Twin for virtual sensing of wind turbine aerodynamic hub loads, as well as monitoring the accumulated fatigue damage and remaining useful life in drivetrain bearings based on measurements of the Supervisory Control and Data Acquisition (SCADA) and the drivetrain condition monitoring system (CMS). The aerodynamic load estimation is realized with data-driven regression models, while the estimation of local bearing loads and damage is conducted with physics-based, analytical models. Field measurements of the DOE 1.5 research turbine are used for model training and validation. The results show low errors of 6.4% and 1.1% in the predicted damage at the main and the generator side high-speed bearing respectively. Zusammenfassung: In diesem Aufsatz wird ein digitaler Zwilling für Windenergieanlagen vorgestellt, welcher die virtuelle Erfassung der Hauptwellenlasten und die Zustandsüberwachung von Ermüdungschäden und der verbleibende Nutzungsdauer der Antriebsstranglager ermöglicht. Der digital Zwilling nutzt Messdaten des Supervisory Control and Data Acquisition (SCADA) Systems und des Zustandsüberwachungssystems des Antriebsstranges (CMS). Die Berechnung der Hauptwellenlasten ist mit datenbasierten Regressionsmodellen umgesetzt, während die Berechnung der Lagerkräfte und der Ermüdungsschaden mit physikbasierten Modelle durchgeführt wird. Für die Modellentwicklung und -validierung werden Feldmessdaten der DOE 1.5MW Turbine eingesetzt. Die Abweichungen in den Ermüdungsschäden am Hauptwellenlager und am Generatorwellenlager betragen lediglich 6,4% beziehungsweise 1,1%.

17 WIND ENERGY↗

A second-order 3D electromagnetics algorithm for curved interfaces between anisotropic dielectrics on a Yee mesh

A new frequency-domain electromagnetics algorithm is developed for simulating curved interfaces between anisotropic dielectrics embedded in a Yee mesh with second-order error in resonant frequencies. The algorithm is systematically derived using the finite integration formulation of Maxwell's equations on the Yee mesh. Second-order convergence of the error in resonant frequencies is achieved by guaranteeing first-order error on dielectric boundaries and second-order error in bulk (possibly anisotropic) regions. Convergence studies, conducted for an analytically solvable problem and for a photonic crystal of ellipsoids with anisotropic dielectric constant, both show second-order convergence of frequency error; the convergence is sufficiently smooth that Richardson extrapolation yields roughly third-order convergence. The convergence of electric fields near the dielectric interface for the analytic problem is also presented.

97 MATHEMATICS AND COMPUTING↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

Alignment of a vector magnetometer to an optical prism

A method for alignment of a vector magnetometer to a rigidly attached prism is presented. This enables optical comparison of the magnetometer axes to physical surfaces in the apparatus, and thus an absolute determination of the magnetic field direction in space. This is in contrast with more common techniques, which focus on precise determination of the relative angles between magnetometer axes, and so are more suited to measuring differences in the direction of magnetic fields. Here we demonstrate precision better than 500 μrad on a fluxgate magnetometer, which also gives the coil orthogonality errors to a similar precision. As a result, the relative sensitivity of the three axes is also determined, with a precision of about 5 ×10 –4 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEW INSIGHTS ON THE GALACTIC BULGE INITIAL MASS FUNCTION

We have derived the Galactic bulge initial mass function (IMF) of the Sagittarius Window Eclipsing Extrasolar Planet Search field in the mass range 0.15 < M/M{sub ⊙} 1.0, using deep photometry collected with the Advanced Camera for Surveys on the Hubble Space Telescope. Observations at several epochs, spread over 9 years, allowed us to separate the disk and bulge stars down to very faint magnitudes, F814W ≈ 26 mag, with a proper-motion accuracy better than 0.5 mas yr{sup −1} (20 km s{sup −1}). This allowed us to determine the IMF of the pure bulge component uncontaminated by disk stars for this low-reddening field in the Sagittarius window. In deriving the mass function, we took into account the presence of unresolved binaries, errors in photometry, distance modulus and reddening, as well as the metallicity dispersion and the uncertainties caused by adopting different theoretical color–temperature relations. We found that the Galactic bulge IMF can be fitted with two power laws with a break at M∼ 0.56 M{sub ⊙}, the slope being steeper (α=−2.41±0.50) for the higher masses, and shallower (α=−1.25±0.20) for the lower masses. In the high-mass range, our derived mass function agrees well with the mass function derived for other regions of the bulge. In the low-mass range however, our mass function is slightly shallower, which suggests that separating the disk and bulge components is particularly important in the low-mass range. The slope of the bulge mass function is also similar to the slope of the mass function derived for the disk in the high-mass regime, but the bulge mass function is slightly steeper in the low-mass regime. We used our new mass function to derive stellar mass-to-light values for the Galactic bulge and we obtained 2.1 < M/L{sub F814W} < 2.4 and 3.1 < M/L{sub F606W} < 3.6 according to different assumptions on the slope of the IMF for masses larger than 1M{sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining inflation with future galaxy redshift surveys

With future galaxy surveys, a huge number of Fourier modes of the distribution of the large scale structures in the Universe will become available. These modes are complementary to those of the CMB and can be used to set constraints on models of the early universe, such as inflation. Using a MCMC analysis, we compare the power of the CMB with that of the combination of CMB and galaxy survey data, to constrain the power spectrum of primordial fluctuations generated during inflation. We base our analysis on the Planck satellite and a spectroscopic redshift survey with configuration parameters close to those of the Euclid mission as examples. We first consider models of slow-roll inflation, and show that the inclusion of large scale structure data improves the constraints by nearly halving the error bars on the scalar spectral index and its running. If we attempt to reconstruct the inflationary single-field potential, a similar conclusion can be reached on the parameters characterizing the potential. We then study models with features in the power spectrum. In particular, we consider ringing features produced by a break in the potential and oscillations such as in axion monodromy. Adding large scale structures improves the constraints on features by more than a factor of two. In axion monodromy we show that there are oscillations with small amplitude and frequency in momentum space that are undetected by CMB alone but can be measured by including galaxy surveys in the analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-117: Verification Method for the Detection Accuracy of Automatic Winston Lutz Test

Purpose: Winston Lutz test (WLT) has been a standard QA procedure performed prior to SRS treatment, to verify the mechanical iso-center setup accuracy upon different Gantry/Couch movements. Several detection algorithms exist,for analyzing the ball-radiation field alignment automatically. However, the accuracy of these algorithms have not been fully addressed. Here, we reveal the possible errors arise from each step in WLT, and verify the software detection accuracy with the Rectilinear Phantom Pointer (RLPP), a tool commonly used for aligning treatment plan coordinate with mechanical iso-center. Methods: WLT was performed with the radio-opaque ball mounted on a MIS and irradiated onto EDR2 films. The films were scanned and processed with an in-house Matlab program for automatic iso-center detection. Tests were also performed to identify the errors arise from setup, film development and scanning process. The radioopaque ball was then mounted onto the RLPP, and offset laterally and longitudinally in 7 known positions ( 0, ±0.2, ±0.5, ±0.8 mm) manually for irradiations. The gantry and couch was set to zero degree for all irradiation. The same scanned images were processed repeatedly to check the repeatability of the software. Results: Miminal discrepancies (mean=0.05mm) were detected with 2 films overlapped and irradiated but developed separately. This reveals the error arise from film processor and scanner alone. Maximum setup errors were found to be around 0.2mm, by analyzing data collected from 10 irradiations over 2 months. For the known shift introduced using the RLPP, the results agree with the manual offset, and fit linearly (R{sup 2}>0.99) when plotted relative to the first ball with zero shift. Conclusion: We systematically reveal the possible errors arise from each step in WLT, and introduce a simple method to verify the detection accuracy of our in-house software using a clinically available tool.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-11: Volumetric Modulated Arc Therapy for Total Body Irradiation

Purpose: To develop a modern, patient-comfortable total body irradiation (TBI) technique suitable for standard-sized linac vaults. Methods: An indexed rotatable immobilization system (IRIS) was developed to make possible total-body CT imaging and radiation delivery on conventional couches. Treatment consists of multi-isocentric volumetric modulated arc therapy (VMAT) to the upper body and parallel-opposed fields to the lower body. Each isocenter is indexed to the couch and includes a 180° IRIS rotation between the upper and lower body fields. VMAT fields are optimized to satisfy lung dose objectives while achieving a uniform therapeutic dose to the torso. End-to-end tests with a rando phantom were used to verify dosimetric characteristics. Treatment plan robustness regarding setup uncertainty was assessed by simulating global and regional isocenter setup shifts on patient data sets. Dosimetric comparisons were made with conventional extended distance, standing TBI (cTBI) plans using a Monte Carlo-based calculation. Treatment efficiency was assessed for eight courses of patient treatment. Results: The IRIS system is level and orthogonal to the scanned CT image plane, with lateral shifts <2mm following rotation. End-to-end tests showed surface doses within ±10% of the prescription dose, field junction doses within ±15% of prescription dose. Plan robustness tests showed <15% changes in dose with global setup errors up to 5mm in each direction. Local 5mm relative setup errors in the chest resulted in < 5% dose changes. Local 5mm shift errors in the pelvic and upper leg junction resulted in <10% dose changes while a 10mm shift error causes dose changes up to 25%. Dosimetric comparison with cTBI showed VMAT-TBI has advantages in preserving chest wall dose with flexibility in leveraging the PTV-body and PTV-lung dose. Conclusion: VMAT-TBI with the IRIS system was shown clinically feasible as a cost-effective approach to TBI for standard-sized linac vaults.

60 APPLIED LIFE SCIENCES↗