Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

SU-E-I-65: The Joint Commission's Requirements for Annual Diagnostic Physics Testing of Nuclear Medicine Equipment, and a Clinically Relevant Methodology for Testing Low-Contrast Resolution

Purpose: To introduce the Joint Commission's requirements for annual diagnostic physics testing of all nuclear medicine equipment, effective 7/1/2014, and to highlight an acceptable methodology for testing lowcontrast resolution of the nuclear medicine imaging system. Methods: The Joint Commission's required diagnostic physics evaluations are to be conducted for all of the image types produced clinically by each scanner. Other accrediting bodies, such as the ACR and the IAC, have similar imaging metrics, but do not emphasize testing low-contrast resolution as it relates clinically. The proposed method for testing low contrast resolution introduces quantitative metrics that are clinically relevant. The acquisition protocol and calculation of contrast levels will utilize a modified version of the protocol defined in AAPM Report #52. Results: Using the Rose criterion for lesion detection with a SNRpixel = 4.335 and a CNRlesion = 4, the minimum contrast levels for 25.4 mm and 31.8 mm cold spheres were calculated to be 0.317 and 0.283, respectively. These contrast levels are the minimum threshold that must be attained to guard against false positive lesion detection. Conclusion: Low contrast resolution, or detectability, can be properly tested in a manner that is clinically relevant by measuring the contrast level of cold spheres within a Jaszczak phantom using pixel values within ROI's placed in the background and cold sphere regions. The measured contrast levels are then compared to a minimum threshold calculated using the Rose criterion and a CNRlesion = 4. The measured contrast levels must either meet or exceed this minimum threshold to prove acceptable lesion detectability. This research and development activity was performed by the authors while employed at West Physics Consulting, LLC. It is presented with the consent of West Physics, which has authorized the dissemination of the information and/or techniques described in the work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-18A-09: Exam and Patient Parameters Affecting the DNA Damage Response Following CT Studies

Purpose: To identify exam and patient parameters affecting the biological response to CT studies using in vivo and ex vivo blood samples. Methods: Blood samples were collected under IRB approval from 16 patients undergoing clinically-indicated CT exams. Blood was procured prior to, immediately after and 30minutes following irradiation. A sample of preexam blood was placed on the patient within the exam region for ex vivo analysis. Whole blood samples were fixed immediately following collection and stained for γH2AX to assess DNA damage response (DDR). Median fluorescence of treated samples was compared to non-irradiated control samples for each patient. Patients were characterized by observed biological kinetic response: (a) fast — phosphorylation increased by 2minutes and fell by 30minutes, (b) slow — phosphorylation continued to increase to 30minutes and (c) none — little change was observed or irradiated samples fell below controls. Total dose values were normalized to exam time for an averaged dose-rate in dose/sec for each exam. Relationships between patient biological responses and patient and exam parameters were investigated. Results: A clearer dose response at 30minutes is observed for young patients (<61yoa; R2>0.5) compared to old patients (>61yoa; R{sup 2}<0.11). Fast responding patients were significantly younger than slow responding patients (p<0.05). Unlike in vivo samples, age did not significantly affect the patient response ex vivo. Additionally, fast responding patients received exams with significantly smaller dose-rate than slow responding patients (p<0.05). Conclusion: Age is a significant factor in the biological response suggesting that DDR may be more rapid in a younger population and slower as the population ages. Lack of an agerelated response ex vivo suggests a systemic response to radiation not present when irradiated outside the body. Dose-rate affects the biological response suggesting that patient response may be related to scan timing and dose delivery within an exam protocol. All authors receive(d) funding from a Master Research Agreement from Siemens Healthcare with UCLA Radiological Sciences.

60 APPLIED LIFE SCIENCES↗

Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330M+, manufactured by Quanterra, a division of Kinemetrics Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, input impedance, power consumption, self noise, dynamic range, system noise, relative transfer function, analog bandwidth, modified noise power ratio, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Q330M+ provides six channels of 24 bit digitization, all of which may be transmitted utilizing CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Cu-64 labeled EGF for In Vivo PET Imaging of EGFR Expression

In this project we proposed to establish feasibility of the development of targeted tracers for radionuclide imaging of epidermal growth factor receptors (EGFR) in cancer patients. The significance and impact of the proposed radiotracers are determined by the crucial role that EGFR plays in many cancers and by the rapid entrance of EGFR-inhibiting drugs into clinic. Clinical experience, however, revealed that only 10-25% of patients that are defined as EGFR-positive by immunohistochemical analysis respond to EGFR-directed therapeutics and there is poor correlation between EGFR immunohistochemistry and treatment. Therefore, for more efficacious use of EGFR-targeting therapeutics, there is a need for information about EGFR activity in patients. We hypothesized that radionuclide imaging of functionally active EGFR will provide such information and would allow for 1) rational patient stratification, 2) rapid monitoring of responses to therapy, and 3) development of personalized treatment regimens. We hypothesized that tracers based epidermal growth factor (EGF), a natural EGFR ligand, as a targeting vector would be particularly advantageous. First, only functionally active and therefore critical for disease progression EGFRs will bind and internalize an EGF-based tracer. Second, continuous internalization of EGF-based tracers by recyclable EGFR would lead to intracellular accumulation of radionuclide and improved signal-to-background ratio. Third, small size of EGF relative to antibodies would facilitate tumor penetration with vastly better non-specific soft tissue and blood clearance rates. Fourth, as a human protein, EGF is not expected to be immunogenic. Finally, at the beginning of this project, we have already engineered and expressed functionally active EGF with an N-terminal Cys-tag for site-specific conjugation of various payloads, including radionuclide chelators. In the Phase I of this project, in collaboration with Dr. Blankenberg’s group at Stanford University, 1. To synthesize and validate in vitro EGF-PEG-DOTA conjugate. The key accomplishment in this part of the project is synthesis of functionally active EGF-PEG-DOTA, construction, expression, and purification of functionally active Cys-tagged dimeric EGF (dEGF) and synthesis of corresponding dEGF-PEG-DOTA, development of protocols for radiolabeling EGF-PEG-DOTA and dEGF-PEG-DOTA with 64Cu. 2. To establish clearance, biodistribution, and stability of EGF-based PET 64Cu radiotracer. These characteristics are established for both EGF-PEG-DOTA/64Cu and dEGF-PEG-DOTA/64Cu and found to be comparable with reported data on 64Cu-radiolabeled antibodies. 3. To evaluate PET tumor imaging with EGF-based 64Cu radiotracer in mouse tumor models. Tumor imaging was evaluated in orthotopic human MDA231luc breast carcinoma model in SCID mice. Tracers accumulated in tumor area, allowing for detection of as small as few millimeter tumors. The Technical Objectives of the projects are accomplished and the results are published in Bioconjugate Chem. 20, 742, 2009.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Centralized and Decentralized Distributed Energy Resource Access Control Implementation Considerations.

A global transition to power grids with high penetrations of renewable energy generation is being driven in part by rapid installations of distributed energy resources (DER). New DER equipment includes standardized IEEE 1547-2018 communication interfaces and proprietary communications capabilities. Interoperable DER provides new monitoring and control capabilities. The existence of multiple entities with different roles and responsibilities within the DER ecosystem makes the Access Control (AC) mechanism necessary. In this paper, we introduce and compare two novel architectures, which provide a Role-Based Access Control (RBAC) service to the DER ecosystem’s entities. Selecting an appropriate RBAC technology is important for the RBAC administrator and users who request DER access authorization. The first architecture is centralized, based on the OpenLDAP, an open source implementation of the Lightweight Directory Access Protocol (LDAP). The second approach is decentralized, based on a private Ethereum blockchain test network, where the RBAC model is stored and efficiently retrieved via the utilization of a single Smart Contract. We have implemented two end-to-end Proofs-of-Concept (PoC), respectively, to offer the RBAC service to the DER entities as web applications. Finally, an evaluation of the two approaches is presented, highlighting the key speed, cost, usability, and security features.

42 ENGINEERING↗

Developing Load Cell Monitoring on the Mock UF 6 Feed and Withdrawal System

A proof-of-concept load cell monitoring system has been developed for the Mock Feed and Withdrawal (F&W) System at Oak Ridge National Laboratory (ORNL). This system leverages industry-standard commercial off-the-shelf (COTS) hardware and software in a modular and scalable design. The Mock F&W System was designed to simulate operations at a uranium hexafluoride (UF 6 ) gas centrifuge enrichment plant F&W area. It provides a test bed for process-monitoring technologies. Water, used as a surrogate for UF 6 , is pumped from three feed tanks, through a process surge tank, and is then cut between two tails tanks and three product tanks. The weight of the each tank is continuously monitored using a load cell monitoring system. In addition to the F&W stations, large and small accountancy stations are monitored. The Mock F&W System allows ORNL to test and evaluate capabilities of industry-standard process monitoring hardware and software. A variety of commonly used weighing indicators are connected to the load cells to monitor the weight at each station. These weighing indicators are representative of the types likely found in operating facilities. A data center modeled after those currently used for international safeguards was installed to collect and manage the weight data. This data center provides a robust and flexible test bed for testing and developing software solutions. COTS software packages that leverage industry-standard communication protocols provide a data flow architecture that is modular, interoperable, and scalable. One software package provides communication drivers to collect the raw weight data from the weighing indicators. A data historian is used to store the raw data. Custom in-house algorithms have been developed using MATLAB to analyze the raw historical data and to automatically identify process information. This information includes the number of cycles completed and the mass of material transferred from stations to the process. The process information identified by the analysis is stored in a Microsoft SQL Server database. Visualization concepts have been developed that display the analyzed process information alongside visually compelling plots and animations of the raw data. The load cell monitoring system developed on the Mock F&W System was designed as a proof of concept that could be scaled to a field trial at an operating facility. This system, built with industry standard hardware and software, has allowed ORNL to develop capabilities that provide confidence in the ability to leverage existing operator load cell monitoring equipment with minimal impact on operations. The international safeguards community is evaluating the use of load cell monitoring as an additional safeguards measure; this system demonstrates a practical solution to collect, store, analyze, and visualize load cell weight data.

commercial off the shelf↗

Pre-Viking Swedish Hillfort Glass: A Prospective Long-Term Alteration Analogue for Vitrified Nuclear Waste

Examining ancient anthropogenic glasses altered in natural environments over hundreds of years can inform and verify models for predicting long-term rates of glass corrosion. Understanding corrosion mechanisms is critical for modeling the performance of nuclear waste glasses that are required to retain radionuclides for >1000 years, and will be disposed in shallow subsurface environments. Two types of ancient Swedish hillfort glasses — one clear, iron-poor glass, and one dark, iron-rich glass — have been characterized to evaluate their use as long-term alteration analogues for vitrified nuclear waste disposed under near-surface conditions. These glasses are of interest to the nuclear waste glass community as they have comparable elemental compositions to glasses under development for disposal of nuclear waste at the Hanford Site, USA. They are also of historical importance to Sweden; thus, an analysis protocol, focusing on non-destructive to semi-destructive analyses, has been developed to maintain the historical integrity of the samples. X-ray computed tomography, micro X-ray diffraction, micro X-ray fluorescence, and electron microscopy data are presented for both vitreous and mineralogical components of the hillfort samples. The internal microstructure and elemental distribution of the glasses, including the presence of crystalline inclusions, are discussed in the context of ancient glassmaking technology.

Weaver, Jamie L.↗

SU-E-T-87: A TG-100 Approach for Quality Improvement of Associated Dosimetry Equipment

Purpose: Dosimetry protocols devote so much time to the discussion of ionization chamber choice, use and performance that is easy to forget about the importance of the associated dosimetry equipment (ADE) in radiation dosimetry - barometer, thermometer, electrometer, phantoms, triaxial cables, etc. Improper use and inaccuracy of these devices may significantly affect the accuracy of radiation dosimetry. The purpose of this study is to evaluate the risk factors in the monthly output dosimetry procedure and recommend corrective actions using a TG-100 approach. Methods: A failure mode and effects analysis (FMEA) of the monthly linac output check procedure was performed to determine which steps and failure modes carried the greatest risk. In addition, a fault tree analysis (FTA) was performed to expand the initial list of failure modes making sure that none were overlooked. After determining the failure modes with the highest risk priority numbers (RPNs), 11 physicists were asked to score corrective actions based on their ease of implementation and potential impact. The results were aggregated into an impact map to determine the implementable corrective actions. Results: Three of the top five failure modes were related to the thermometer and barometer. The two highest RPN-ranked failure modes were related to barometric pressure inaccuracy due to their high lack-of-detectability scores. Six corrective actions were proposed to address barometric pressure inaccuracy, and the survey results found the following two corrective actions to be implementable: 1) send the barometer for recalibration at a calibration laboratory and 2) check the barometer accuracy against the local airport and correct for elevation. Conclusion: An FMEA on monthly output measurements displayed the importance of ADE for accurate radiation dosimetry. When brainstorming for corrective actions, an impact map is helpful for visualizing the overall impact versus the ease of implementation.

07 ISOTOPE AND RADIATION SOURCES↗

Emergency Voltage Regulation in Power Systems via Ripple-Type Control: Preprint

With increasing penetration of volatile renewable generation and cyber-physical disruptions, ensuring safe operation of bulk power systems has become unprecedentedly challenging. Since communication and computational costs restrict centralized system dispatch to be called upon every few minutes; and purely local schemes are shown to be insufficient, distributed controls have been advocated for handling unanticipated system conditions in real time. However, the applicability of distributed control schemes is fundamentally limited by their need for widespread communication and model cognizance. In this con-text, we put forth a hybrid low-communication saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a ‘hotline’ communication network. Under this protocol, when agents observe a constraint violation based on local measurements, they respond locally until their control resources saturate, in which case they send a beacon for assistance to peer agents. The scheme ensures that minor violations are efficiently mitigated via fast local controls, while severe violations may be handled by a collaboration of a relatively small set of agents. We evaluate the performance of this scheme via extensive numerical tests on the IEEE 14-bus test feeder, where agents act upon noisy measurements under diverse scenarios of random load variations and severe low/high voltage events.

distributed control↗

Sensitivity Tests of Aluminum Precipitate Preparation Methods on Head Loss through Debris Beds on a Sump Screen

During a Loss-of-Coolant Accident (LOCA) in Pressurized Water Reactors (PWRs), buffered borated water as a coolant from the Refueling Water Storage Tank (RWST) will be injected into the primary loop to cool down the core depending on the break size. For long-term cooling, the coolant will be collected in the containment sump. Then, the Emergency Core Cooling System (ECCS) will pump the coolant through the sump strainers into the reactor. During this phase, buffered borated water produces chemical precipitate by reacting with the structural materials in the containment. Chemical effects evaluated as part of Generic Safety Issue 191 (GSI-191) resolution studies are broadly defined as any chemically induced phenomenon that affects ECCS performance. Initial chemical effects studies jointly sponsored by the Nuclear Regulatory Commission (NRC) and Industry collaborators led to a Westinghouse Owners Group (WOG) study that provided bases for deterministic quantification of chemical effects. The WCAP-16530-NP developed protocols to produce Aluminum Oxyhydroxide (AlOOH), Calcium Phosphate, and Sodium Aluminum Silicate (SAS). The surrogate generation protocol used the metal salt (aluminum nitrate and calcium acetate) unlike post-LOCA accident scenarios where metals leach into a buffered borated solution. Bahn et al. demonstrated that the WCAP-16530-NP SAS precipitate did not produce as much head loss as the WCAP-16530-NP AlOOH precipitate, thus, the present study focused on the effect of AlOOH precipitate on head loss through a fibrous debris bed. In the past, most of the tests were conducted in high approach velocity conditions, approximately 0.03 m/s. After modifications of sump strainer size in PWRs, the approach velocity to the sump strainer was reduced by an order of magnitude, approximately 0.001 ∼ 0.003 m/s. Howe et al. and Kim et al. conducted several head loss tests at the approach velocity of 0.003 m/s. In the present study, an approach velocity of 0.0006 m/s was selected for an extremely slow power plant condition. A PCI strainer design was used as previous head loss tests and debris bypass tests conducted by Lee et al. Three different chemical precipitate preparation methods were used in this study. The additional head loss of the debris bed caused by those chemical precipitates was investigated. The debris bed was produced with NUKON{sup R} fiberglass thermal insulator and additional particulates including dirt, Tin powder, acrylic powder, and Calcium silicate (CalSil). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems

Purpose: Knowledge of the complete axial dose profile f(z), including its long scatter tails, provides the most complete (and flexible) description of the accumulated dose in CT scanning. The CTDI paradigm (including CTDI{sub vol}) requires shift-invariance along z (identical dose profiles spaced at equal intervals), and is therefore inapplicable to many of the new and complex shift-variant scan protocols, e.g., high dose perfusion studies using variable (or zero) pitch. In this work, a convolution-based beam model developed by Dixon et al.[Med. Phys. 32, 3712-3728, (2005)] updated with a scatter LSF kernel (or DSF) derived from a Monte Carlo simulation by Boone [Med. Phys. 36, 4547-4554 (2009)] is used to create an analytical equation for the axial dose profile f(z) in a cylindrical phantom. Using f(z), equations are derived which provide the analytical description of conventional (axial and helical) dose, demonstrating its physical underpinnings; and likewise for the peak axial dose f(0) appropriate to stationary phantom cone beam CT, (SCBCT). The methodology can also be applied to dose calculations in shift-variant scan protocols. This paper is an extension of our recent work Dixon and Boone [Med. Phys. 37, 2703-2718 (2010)], which dealt only with the properties of the peak dose f(0), its relationship to CTDI, and its appropriateness to SCBCT. Methods: The experimental beam profile data f(z) of Mori et al.[Med. Phys. 32, 1061-1069 (2005)] from a 256 channel prototype cone beam scanner for beam widths (apertures) ranging from a = 28 to 138 mm are used to corroborate the theoretical axial profiles in a 32 cm PMMA body phantom. Results: The theoretical functions f(z) closely-matched the central axis experimental profile data{sup 11} for all apertures (a = 28 -138 mm). Integration of f(z) likewise yields analytical equations for all the (CTDI-based) dosimetric quantities of conventional CT (including CTDI{sub L} itself) in addition to the peak dose f(0) relevant to SCBCT (allowing direct cross-comparison between CT scan modes and mathematical proofs of several hypotheses of practical utility in CT dosimetry). A fast, analytical dose simulator{sup 6} is also demonstrated--successfully matching complex dose distributions measured using OSL and film dosimetry. Conclusions: The model described allows one to obtain analytical functions describing both the primary and scatter components of the axial dose profile. This model (using no empirical functions or adjustable fit parameters) provides a good match to the experimental data, as well as a complete analytical description of dose for both conventional (axial and helical) CT and cone beam CT. An efficient method whereby the complete data set for both modalities can be obtained from a single measurement of either CTDI{sub 100} or f(0) is illustrated. This method is also flexible--allowing calculation of heretofore unattainable doses for recently-introduced shift-variant protocols [e.g., variable pitch (irregular scan spacing), variable aperture, shuttle mode acquisition, and mA modulation schemes].

61 RADIATION PROTECTION AND DOSIMETRY↗

Oak Ridge National Laboratory Evaluation of Stream-Trained Models in Practice

The goal of this integration is to replicate the results from the original paper Autonomous Utility Pole Identification on different camera hardware and integrate the model into a live video stream provided by the unmanned aerial system (UAS) itself while in operation. This involves retraining the original model and validating its efficacy on multiple camera modules to select the most effective device for installation. Moreover, this integration requires writing software to handle the reception of a real-time streaming protocol stream from the UAS and run each frame through the model while allowing a user to monitor the camera feed.

97 MATHEMATICS AND COMPUTING↗

Perioperative Gemcitabine + Erlotinib Plus Pancreaticoduodenectomy for Resectable Pancreatic Adenocarcinoma: ACOSOG Z5041 (Alliance) Phase II Trial

Background: There is considerable interest in a neoadjuvant approach for resectable pancreatic ductal adenocarcinoma (PDAC). This study evaluated perioperative gemcitabine + erlotinib (G+E) for resectable PDAC. Methods: A multicenter, cooperative group, single-arm, phase II trial was conducted between April 2009 and November 2013 (ACOSOG Z5041). Patients with biopsy-confirmed PDAC in the pancreatic head without evidence of involvement of major mesenteric vessels (resectable) were eligible. Patients (n = 123) received an 8-week cycle of G+E before and after surgery. The primary endpoint was 2-year overall survival (OS), and secondary endpoints included toxicity, response, resection rate, and time to progression. Resectability was assessed retrospectively by central review. The study closed early due to slow accrual, and no formal hypothesis testing was performed. Results: Overall, 114 patients were eligible, consented, and initiated protocol treatment. By central radiologic review, 97 (85%) of the 114 patients met the protocol-defined resectability criteria. Grade 3+ toxicity was reported in 60% and 79% of patients during the neoadjuvant phase and overall, respectively. Twenty-two of 114 (19%) patients did not proceed to surgery; 83 patients (73%) were successfully resected. R0 and R1 margins were obtained in 67 (81%) and 16 (19%) resected patients, respectively, and 54 patients completed postoperative G+E (65%). The 2-year OS rate for the entire cohort (n = 114) was 40% (95% confidence interval [CI] 31–50), with a median OS of 21.3 months (95% CI 17.2–25.9). The 2-year OS rate for resected patients (n = 83) was 52% (95% CI 41–63), with a median OS of 25.4 months (95% CI 21.8–29.6). Conclusions: For resectable PDAC, perioperative G+E is feasible. Further evaluation of neoadjuvant strategies in resectable PDAC is warranted with more active systemic regimens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Separation of thorium, uranium, and rare earths from a strip solution generated from coarse coal refuse

This work systematically evaluated the separation performance of thorium, uranium, and rare earths when coal and coal byproduct were utilized as a non-traditional feedstock for rare earth production. A synthetic solution was prepared following the elemental composition of a strip solution generated from coarse coal refuse and used throughout the study. Various separation techniques including selective precipitation, solvent extraction, and a modified experimental protocol incorporating the two were applied to extract rare earths while minimizing the non-selective recovery of thorium and uranium into the product stream. Test results indicate that selective precipitation was effective for the removal of thorium at a pH value approaching 5 while solvent extraction preferentially removed uranium from rare earths. Therefore, a modified experimental protocol consisting of both selective precipitation and solvent extraction was subsequently developed and implemented. The findings following the modified experimental protocol indicate that extractant concentration, solvent extraction feed pH, and organic to aqueous (O/A) ratio all played a significant role in the removal of uranium. Among all the tests conducted, the best separation performance was achieved using a one-stage precipitation at a pH value of 4.8, 50 v% TBP, solvent extraction feed pH of 3.5, and an O/A ratio of 3, which corresponded to an overall rare earth, thorium, and uranium recovery of 79.6%, 0%, and 3.1%, respectively.

01 COAL, LIGNITE, AND PEAT↗

Potential environmental effects of deepwater floating offshore wind energy facilities

Over the last few decades, the offshore wind energy industry has expanded its scope from turbines mounted on fixed platforms driven into the seafloor and standing in less than 50 meters of water, to floating turbines moored in 120 meters of water, to prospecting the development of floating turbines moored in ~1000 meters of water. Since there are few prototype turbines and mooring systems of these deepwater, floating offshore wind energy facilities (OWFs) currently deployed, their effects on the marine environment are largely unknown. Using the available scientific literature concerning appropriate analogs, this study provides the first synthesis of the potential environmental effects of deepwater, floating OWFs during operation, as well as potential mitigation measures to some of the risks. Potential effects we identify and evaluate include changes to atmospheric and oceanic dynamics, electromagnetic fields, habitat alterations, noise, structural impediments, and changes to water quality that could affect a variety of marine species across trophic levels. Our synthesis suggests that many of these potential effects could be mitigated to pose a low risk to the marine environment if developers adopt appropriate mitigation strategies and best-practice protocols. This review takes the necessary first steps in summarizing the available information on the potential environmental effects of deepwater, floating OWFs and can serve as a valuable reference document for marine scientists and engineers, the energy industry, permitting agencies and regulators of the energy industry, project developers, and concerned stakeholders such as coastal residents, conservationists, and fisheries.

Farr, Hayley K.↗

Equilibration and analysis of first-principles molecular dynamics simulations of water

First-principles molecular dynamics (FPMD) simulations based on density functional theory are becoming increasingly popular for the description of liquids. In view of the high computational cost of these simulations, the choice of an appropriate equilibration protocol is critical. In this study, we assess two methods of estimation of equilibration times using a large dataset of first-principles molecular dynamics simulations of water. The Gelman-Rubin potential scale reduction factor [A. Gelman and D. B. Rubin, Stat. Sci. 7, 457 (1992)] and the marginal standard error rule heuristic proposed by White [Simulation 69, 323 (1997)] are evaluated on a set of 32 independent 64-molecule simulations of 58 ps each, amounting to a combined cumulative time of 1.85 ns. The availability of multiple independent simulations also allows for an estimation of the variance of averaged quantities, both within MD runs and between runs. We analyze atomic trajectories, focusing on correlations of the Kohn-Sham energy, pair correlation functions, number of hydrogen bonds, and diffusion coefficient. The observed variability across samples provides a measure of the uncertainty associated with these quantities, thus facilitating meaningful comparisons of different approximations used in the simulations. We find that the computed diffusion coefficient and average number of hydrogen bonds are affected by a significant uncertainty in spite of the large size of the dataset used. Lastly, a comparison with classical simulations using the TIP4P/2005 model confirms that the variability of the diffusivity is also observed after long equilibration times. Complete atomic trajectories and simulation output files are available online for further analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ProvLight: Efficient Workflow Provenance Capture on the Edge-to-Cloud Continuum

Modern scientific workflows require hybrid infrastructures combining numerous decentralized resources on the IoT/Edge interconnected to Cloud/HPC systems (aka the Computing Continuum) to enable their optimized execution. Understanding and optimizing the performance of such complex Edge-to-Cloud workflows is challenging. Capturing the provenance of key performance indicators, with their related data and processes, may assist in understanding and optimizing workflow executions. However, the capture overhead can be prohibitive, particularly in resource-constrained devices, such as the ones on the IoT/Edge.To address this challenge, based on a performance analysis of existing systems, we propose ProvLight, a tool to enable efficient provenance capture on the IoT/Edge. We leverage simplified data models, data compression and grouping, and lightweight transmission protocols to reduce overheads. We further integrate ProvLight into the E2Clab framework to enable workflow provenance capture across the Edge-to-Cloud Continuum. This integration makes E2Clab a promising platform for the performance optimization of applications through reproducible experiments.We validate ProvLight at a large scale with synthetic workloads on 64 real-life IoT/Edge devices in the FIT IoT LAB testbed. Evaluations show that ProvLight outperforms state-of-the-art systems like ProvLake and DfAnalyzer in resource-constrained devices. ProvLight is 26—37x faster to capture and transmit provenance data; uses 5—7x less CPU; 2x less memory; transmits 2x less data; and consumes 2—2.5x less energy. ProvLight [1] and E2Clab [2] are available as open-source tools.

Rosendo, Daniel↗