Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Oxygen Reduction on Platinum-Nickel and Platinum-Cobalt Alloy Based Catalysts for High Temperature Proton Exchange Membrane Fuel Cells

Catalyst layers, with commercial PtNi/TKK (TECNiE52; platinum 46.5 wt%), PtCo/TKK (TEC36E52; platinum 45.8 wt%) catalysts, and an in-house catalyst PtNi-NC (platinum 38.4 wt%), synthesised using acoustic mixer and a tube furnace, are prepared using three different ionomers: 20 wt% Nafion®, 60 wt% polytetrafluoroethylene (PTFE), and an in-house 5 wt% ionomer (‘Ionomer X’). These inks are bar-coated onto carbon paper gas diffusion layers (GDLs), which are cut into 3 cm × 5 cm pieces. The coated layers are tested for oxygen reduction in a commercial gas diffusion electrode (GDE) test cell, FlexCell® (Gaskatel GmbH, Germany), using 85 wt% phosphoric acid at both room temperature and at 155°C. This study evaluates the polynorbornene (PNB)-based in-house ionomer performance as binder and in-house catalyst oxygen reduction reaction (ORR) activity in comparison to commercial products. The catalyst layers are characterised using X-ray diffraction (XRD) analysis, X-ray photoelectron spectroscopy (XPS), and high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM). Among the catalyst layers prepared with PTFE ionomer and tested at 155°C, the in-house catalyst demonstrates the highest ORR activity. Ionomer X proves to be a good candidate to be used as a per- and polyfluoroalkyl-free binder for high-temperature (HT) proton exchange membrane fuel cell (PEMFC) applications.

85 wt% phosphoric acid↗

Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Dual-RF Phase Control for Adiabatic Energy Ramping in the EIC Rapid Cycling Synchrotron

The Electron-Ion Collider (EIC) Rapid Cycling Synchrotron (RCS) accelerates electrons from 750 MeV to 10 GeV over approximately 64.7 ms. While the baseline design simultaneously ramps both RF voltage and phase, this study evaluates an alternative where RF cavities are divided into two groups, each operating at a fixed 6.5 MV, with the effective voltage synthesized through phase control. In the symmetric scheme (Option A), both groups vary symmetrically about the synchronous phase to provide exact matching of energy gain and synchrotron tune throughout the ramp. Conversely, the asymmetric scheme (Option B) pins one group at the final operating phase while the other varies to supply the required energy gain. The feasibility of Option B is determined by the adiabaticity of the resulting synchrotron tune evolution, with ramp profiles, phase trajectories, and adiabaticity metrics analyzed for both implementations.

Gamage, B. [Thomas Jefferson National Accelerator ↗

Subsoil Potassium in Central Iowa Soils: Status and Future Challenges

A reevaluation of plant-available K within central Iowa soils is needed, especially if crop residues are harvested for animal feed or cellulosic feedstock. This study evaluated plant-available K concentrations to depths of 120 cm (n = 2433) within soil profiles at 10 experimental sites. Data from 0- to 5-, 5- to 15-, 0- to 15-, 15- to 30-, 30- to 60-, 60- to 90-, and 90- to 120-cm depths were compiled and evaluated. Based on over 400 samples collected from each depth increment below 15 cm, a reference value of 100 mg kg –1 appears common for central Iowa subsoils. Sixty-four percent of all samples had soil-test K levels below the 120 mg kg –1 threshold for very low nutrient status for crop production in Iowa. Only 28% of surface soil samples (<15-cm depth) were considered to have at least optimum nutrient status with concentrations greater than 160 mg kg –1 . As K is not an environmentally sensitive nutrient, its management in central Iowa soils has generally been neglected in recent years, particularly when compared with N and P management initiatives. Building awareness of soil K profile concentrations, rather than focusing only on surface concentrations, will be necessary to meet nutrient requirements for 21st century agricultural production.

54 ENVIRONMENTAL SCIENCES↗

Energycane ( Saccharum spp. × Saccharum spontaneum L.) Biomass Production, Reproduction, and Weed Risk Assessment Scoring in the Humid Tropics and Subtropics

There is growing interest in biofuel production, and energycane ( Saccharum spp. × S. spontaneum L.) has been proposed as an important biofuel and biomass crop. However, little is known about the growth and ecology of this new crop, especially in the tropics. The present study evaluated the performance of 14 energycane clones, elephantgrass ( Pennisetum purpureum Schumach.), and two sugarcane ( S. officinarum L.) varieties in the humid tropics of Costa Rica, and eight energycane clones in the subtropics of Florida. In the tropics, energycane's growth and biomass production were highly variable when comparing clones. However, the best performing clones US85‐1006, US88‐1006, and US78‐1014 produced almost twice the dry biomass (>64 Mg ha −1 ) compared with sugarcane varieties Pindar and Q‐132 (21–39 Mg ha −1 ). In the subtropics, energycane fresh (52–79 Mg ha −1 ) and dry (20–30 Mg ha −1 ) weights were less than half of those in the tropics. Energycane clones flowered in both environments, but pollen viability was three to four times higher (>40%) in the tropics than in the subtropics, although viable seeds were found only in the tropics. Weed risk assessment (WRA) scores were higher in the tropics than in the subtropics and varied among clones. The results confirmed that energycane is a promising feedstock for biomass production and could play an important role as a bioenergy crop when grown in the tropics and subtropics, but due to genotype × environment interactions, the tradeoff between biomass production and weedy and invasive risk must be assessed for each individual clone and environment.

Leon, Ramon G.↗

Biochar Produced from Anaerobically Digested Fiber Reduces Phosphorus in Dairy Lagoons

This study evaluated the use of biochar produced from anaerobic digester dairy fiber (ADF) to sequester phosphorus (P) from dairy lagoons. The ADF was collected from a plugged flow digester, air-dried to <8% water content, and pelletized. Biochar was produced by slow pyrolysis in a barrel retort. The potential of biochar to reduce P in the anaerobic digester effluent (ADE) was assessed in small-scale filter systems through which the effluent was circulated. Biochar sequestered an average of 381 mg L -1 P from the ADE, and 4 g L -1 ADF was captured as a coating on the biochar. There was an increase of total (1.9 g kg -1 ), Olsen (763 mg kg -1 ), and water-extractable P (914 mg kg -1 ) bound to the biochar after 15 d of filtration. This accounted for a recovery of 32% of the P in the ADE. The recovered P on the biochar was analyzed using 31 P nuclear magnetic resonance for P speciation, which confirmed the recovery of inorganic orthophosphate after liquid extraction of the biochar and the presence of inextractable Ca-P in the solid state. The inorganic phosphate was sequestered on the biochar through physical and weak chemical bonding. Finally, results indicate that biochar could be a beneficial component to P reduction in the dairy system.

Environmental Molecular Sciences Laboratory↗

Factorial experiment to identify two-way interactions between temperature, harvesting period, hydraulic retention time, and light intensity that influence the biomass productivity and phosphorus removal efficiency of a microalgae–bacteria biofilm

Rotating algae biofilm reactors (RABRs) can reduce energy requirements for wastewater reclamation but require further optimization for implementation at water resource recovery facilities (WRRF). Optimizing RABR operation is challenging because conditions at WRRF change frequently, and disregarding interaction terms related to these changes can produce incorrect conclusions about RABR behavior. This study evaluated the two-way interaction and main effects of four factors on the biomass productivity and phosphorus removal efficiency of a microalgae-bacteria biofilm grown in municipal anaerobic digester centrate, with factor levels and operating conditions selected to mimic a pilot RABR at a WRRF in Utah. Two-way interactions harvesting period*light intensity (LI), harvesting period*temperature, and LI*hydraulic retention time (HRT) had significant effects on biomass productivity: at high temperature and low LI, highest biomass productivity was achieved with a 14-day harvesting period, but at medium temperature and high LI, highest biomass productivity was achieved with a 7-day harvesting period. At high HRT, highest biomass productivity occurred at low LI, but at low HRT, highest biomass productivity occurred at high LI. Phosphorus removal was strongly influenced by LI and occurred most rapidly during the first 2 days HRT, which suggests precipitation contributed significantly to phosphorus removal. These observations provide insight for further RABR optimization.

09 BIOMASS FUELS↗

Magnetic fly-ash geopolymer for heavy metal removal in aqueous solutions

Novel magnetic geopolymers were manufactured by synthesizing magnetic Fe 3 O 4 particles on the surface of prepared geopolymer (Method 1) or by incorporating pre-synthesized magnetic Fe 3 O 4 particles into the geopolymer during the manufacture of the geopolymer (Method 2). This study evaluated the effect of the incorporated magnetic Fe 3 O 4 on the geopolymer magnetic, physical, and adsorption properties and its separation in aqueous solutions. Based on several preliminary measurements on the synthesized magnetic geopolymers, Method 2 was found to be a better method for producing magnetic geopolymer. Magnetic geopolymer synthesized by Method 2 exhibited ferromagnetic properties comparable to that of magnetic Fe 3 O 4 , with a saturation magnetization of 8 emu·g −1 and an intrinsic coercivity of 265 Oe. The magnetic geopolymer was efficiently separated from an aqueous solution within 2 min using a 0.48-T magnetic field. In addition, the magnetic geopolymer has a maximum copper adsorption capacity of 111.1 mg·g −1 , which was similar to the non-magnetic reference geopolymer indicating that the addition of magnetic Fe 3 O 4 did not compromise the geopolymer adsorption capacity. The magnetic geopolymer is a promising material with good adsorption and separation properties that can be used for heavy metals removal and recovery in wastewater and metals separation in industrial processes.

fly ash↗

Small Aperture BPM to Quadrupole Assembly Tolerance Study

The LCLS injector and linac systems utilize a series of quadrupole magnets with a beam position monitor (BPM) captured in the magnet pole tips. The BPM measures the electron beam position by comparing the electrical signal from 4 electrodes and interpolating beam position from these signals. The manufacturing tolerances of the magnet and BPM are critical in determining the mechanical precision of the electrodes relative to the nominal electron beam Z-axis. This study evaluates the statistical uncertainty of the electrodes center axis relative to the nominal electron beam axis.

43 PARTICLE ACCELERATORS↗

Comparison of Alternatives to the 2004 Vacuum Vessel Heat Transfer System

A study comparing different alternatives for the Vacuum Vessel Primary Heat Transfer System has been completed. Three alternatives were proposed in a Project Change Request (PCR-190) by relocating the heat exchangers (HXs) from the roof of the Tokamak building to inside the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The study evaluated the three alternatives and recommended modifications to one of them to arrive at a preferred configuration that included relocating the HXs inside the Tokamak building but outside the VVPSS tank as well as including a small safety-rated pump and HX in parallel to the main circulation pump and HX. The Vacuum Vessel (VV) Primary Heat Transfer System (PHTS) removes heat generated in the VV during normal operation (10 MW, pulsed power) as well as the decay heat from the VV itself and from the structures/components attached to the VV (first wall, blanket, and divertor {approx}0.48 MW peak). Therefore, the VV PHTS has two safety functions: (1) contain contaminated cooling water (similar to the other PHTSs) and (2) provide passive cooling during an accident event. The 2004 design of the VV PHTS consists of two independent loops, each loop cooling half of the 18 VV segments with a nominal flow of 475 kg/s of water at about 1.1 MPa and 100 C. The total flow for both loops is 950 kg/s. Both loops are required to remove the heat load during normal plasma operation. During accident conditions, only one loop is needed to remove by natural convection (no pump needed) the decay heat of the complete VV and attached components. The heat is transferred to heat exchanger (HXs) located on top of the roof, outside the Tokamak building. These HXs are air-to-water (A/W) HXs. Three alternatives have been proposed for this cooling system. For a detailed discussion of these alternatives, please refer to Project Change Request, PCR-190 (Ref. 1). A brief introduction is given here. Alternative 1 includes only one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump. In addition, this alternative has two natural circulation safety loops. Both the safety and main loops supply water to the bottom of the VV with six branch lines and collect the heated water at the top of the vessel through six branches. The distribution headers are located in the lower pipe chase and the collection headers in the upper pipe chase. Each of these loops (one main and two emergency) has a HX mounted in the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The main HX is cooled using either Component Cooling Water System (CCWS) or Chilled Water System (CHWS) water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 1 taken from PCR-190. Alternative 2 is exactly the same as Alternative 1 except that there is only one emergency loop and one emergency HX. See Fig. 2 taken from PCR-190. Alternative 3 also has one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump and one natural circulation safety loop. In this case, both the safety and main loops supply water to the top of the VV with three branch lines and collect the heated water at the top of the vessel through three branches. Here, the distribution header is located in the upper pipe chase as is the collection header. As before, each of these loops has a HX mounted in the VVPSS tank. The main HX is cooled using either CCWS or CHWS water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 3 taken from PCR-190. The preferred configuration is developed by selecting specific attributes of the other configurations analyzed and the logic for selecting this configuration is discussed at the end of the document. It is a modification of Alternative 2 that eliminates the separate safety loop, but incorporates a small safety rated HX and pump in parallel with the main HX and pump. It uses 18 inlet and 18 outlet branches (as did the 2004 design) and locates the HXs outside of the VVPSS tank. Tables 1 and 2 examine alternatives to the 2004 VV heat transfer system design that were proposed in PCR-190, as well as the preferred option.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of Rhodium-Based Catalysts for Mixed Alcohol Synthesis -- 2009 Progress Report

Pacific Northwest National Laboratory (PNNL) has been conducting research for the United States Department of Energy, Energy Efficiency Renewable Energy, Biomass Program to investigate the feasibility of producing mixed alcohols from biomass-derived synthesis gas (syngas). This research has involved the screening of potential catalysts, and optimization of the more promising ones, using laboratory scale reactors. During 2009, the main goal of the testing program focused on optimizing selected supported catalysts containing rhodium (Rh) and manganese (Mn). Optimization involved examining different total concentrations and atomic ratios of Rh and Mn as well as that of the more promising promoters (Ir and Li) identified in the earlier screening studies. Evaluation of catalyst performance focused on attaining improvements with respect to the space-time-yield and converted carbon selectivity to C2+ oxygenates, with additional consideration given to the fraction of the oxygenates that were C2+ alcohols.

09 BIOMASS FUELS↗

ANALYTICAL NEUTRONIC STUDIES CORRELATING FAST NEUTRON FLUENCE TO MATERIAL DAMAGE IN CARBON, SILICON, AND SILICON CARBIDE

This study evaluates how fast neutron fluence >0.1 MeV correlates to material damage (i.e., the total fluence spectrum folded with the respective material’s displacements-per- atom [dpa] damage response function) for the specific material fluence spectra encountered in Next Generation Nuclear Plant (NGNP) service and the irradiation tests conducted in material test reactors (MTRs) for the fuel materials addressed in the white paper. It also reports how the evaluated correlations of >0.1 MeV fluence to material damage vary between the different spectral conditions encountered in material service versus testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Efficient Upscaling Methodology for Predicting Thermal Conductivity of Nuclear Waste forms

This study evaluated different upscaling methods to predict thermal conductivity in loaded nuclear waste form, a heterogeneous material system. The efficiency and accuracy of these methods were compared. Thermal conductivity in loaded nuclear waste form is an important property specific to scientific researchers, in waste form Integrated performance and safety code (IPSC). The effective thermal conductivity obtained from microstructure information and local thermal conductivity of different components is critical in predicting the life and performance of waste form during storage. How the heat generated during storage is directly related to thermal conductivity, which in turn determining the mechanical deformation behavior, corrosion resistance and aging performance. Several methods, including the Taylor model, Sachs model, self-consistent model, and statistical upscaling models were developed and implemented. Due to the absence of experimental data, prediction results from finite element method (FEM) were used as reference to determine the accuracy of different upscaling models. Micrographs from different loading of nuclear waste were used in the prediction of thermal conductivity. Prediction results demonstrated that in term of efficiency, boundary models (Taylor and Sachs model) are better than self consistent model, statistical upscaling method and FEM. Balancing the computation resource and accuracy, statistical upscaling is a computational efficient method in predicting effective thermal conductivity for nuclear waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Geospatially Modeled Fire Behavior and Potential Application to Fire and Fuels Management for the Savannah River Site

This study evaluates modeled fire behavior for the Savannah River Site in the Atlantic Coastal Plain of the southeastern U.S. using three data sources: FCCS, LANDFIRE, and SWRA. The Fuel Characteristic Classification System (FCCS) was used to build fuelbeds from intensive field sampling of 629 plots. Custom fire behavior fuel models were derived from these fuelbeds. LANDFIRE developed surface fire behavior fuel models and canopy attributes for the U.S. using satellite imagery informed by field data. The Southern Wildfire Risk Assessment (SWRA) developed surface fire behavior fuel models and canopy cover for the southeastern U.S. using satellite imagery.

60 APPLIED LIFE SCIENCES↗

Thermal Screening Of Residues From Acidification And Copper-Catalyzed Peroxide Oxidation Of Tank 48H Simulant

This study evaluated the residues generated from copper-catalyzed peroxide oxidation (CCPO) of Tank 48H simulant. The first step of the CCPO calls for pH adjustment of the simulant, and early testing used either 15wt% or 50wt % nitric acid to reach a slurry pH of between 12 and 5. Residues obtained by ambient temperature pH adjustment with 50wt % nitric acid followed by oxidation with 50 wt % hydrogen peroxide at 35, 50, and 65°C (from a recently conducted Copper Catalyzed Peroxide Oxidation or CCPO) were also analyzed. Slurry samples at pH 7 or lower especially made from adding nitric acid at the process equivalent of one gallon per minute had the largest enthalpy of decomposition. The thermogravimetric characteristics of some samples from the CCPO test generated at pH 9 or lower exhibited rapid weight loss. Taken together, residues generated at pH 9 or lower may be classified as energetic upon decomposition in confined spaces or under adiabatic conditions. Therefore, additional testing is recommended with larger (up to 50mL) samples in an adiabatic calorimeter. To minimize risk of formation of energetic byproducts, an intermediate slurry pH of 9 or greater is recommended following the acidification step in the CCPO and prior to start of peroxide addition. In practice, process temperature needs to reach 150°C or greater to decompose residues obtained a pH 9 or lower which is unlikely. Oxidation temperature had no significant effect on the thermal characteristics of the final residues generated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Collaborative Research: Towards Advanced Understanding and Predictive Capability of Climate Change in the Arctic Using a High-Resolution Regional Arctic Climate System Model

The motivation for this project was to advance the science of climate change and prediction in the Arctic region. Its primary goals were to (i) develop a state-of-the-art Regional Arctic Climate system Model (RACM) including high-resolution atmosphere, land, ocean, sea ice and land hydrology components and (ii) to perform extended numerical experiments using high performance computers to minimize uncertainties and fundamentally improve current predictions of climate change in the northern polar regions. These goals were realized first through evaluation studies of climate system components via one-way coupling experiments. Simulations were then used to examine the effects of advancements in climate component systems on their representation of main physics, time-mean fields and to understand variability signals at scales over many years. As such this research directly addressed some of the major science objectives of the BER Climate Change Research Division (CCRD) regarding the advancement of long-term climate prediction.

54 ENVIRONMENTAL SCIENCES↗

Energy Savings for Occupancy-Based Control (OBC) of Variable-Air-Volume (VAV) Systems

Terminal boxes usually serve a single building zone, controlling the air-flow rate to the zone and reheating the air when it is too cool. Each terminal box has a minimum air-flow rate that ensures the ventilation requirements of the occupants of the zone served are met. This minimum air-flow rate is maintained at a constant value based on the design occupancy of the zone, which often corresponds to the maximum occupancy, because measurements of actual occupancy are not currently used to adjust the flow rate. Therefore, the minimum flow rate must meet the ventilation needs of the fully occupied zone. The total flow rate may be higher than the minimum to provide adequate cooling or heating, but the minimum for ventilation should always be met. In practice, control system integrators and installers often set the cooling minimum air-flow rate for ventilation to between 30% and 50% of the maximum air-flow rate of the terminal box. Building occupancy, however, varies dynamically. Conference rooms, cafeterias, auditoriums, and other assembly spaces are often unoccupied for significant periods of time. Office occupancy varies during the course of a work day, from day to day, and over the longer term because of attendance of meetings elsewhere, business travel, changing room functions, and variations in staffing. The resulting over-ventilation, during times when the space has less than maximum occupancy or is unoccupied, wastes significant fan energy and causes discomfort for occupants in some spaces (e.g., conference rooms) from overcooling or overheating, especially in interior zones that do not have reheat in the terminal boxes. Common occupancy sensors, which measure whether occupants are present or not, are commonly used for lighting control in conference rooms and other spaces with variable occupancy. They could be used to enable a terminal box to be switched to an occupied standby mode in which the air-flow rate is set to zero when no occupants are in the zone the box serves. If advanced occupancy sensors, which count the actual number of occupants in a room, were used to control terminal boxes, the minimum air-flow rate set point for the terminal box could be reset dynamically based on the actual occupancy sensed. This study evaluates the savings potential from use of occupancy-based control (OBC) of terminal boxes for large office buildings with variable-air-volume (VAV) heating, ventilating and air-conditioning (HVAC) systems using both common occupancy sensors and advanced occupancy sensors.

Zhang, Jian↗

Self-decomposable Fibrous Bridging Additives for Temporary Cementitious Fracture Sealers in EGS Wells

This study evaluates compatibility of a self-degradable temporary fracture sealer with the drilling mud and plugging and self-degrading performance of different fibers to be used in combination with the sealer. The sodium silicate-activated slag/Class C fly ash (SSASC) cementitious sealer must plug fractures at 85oC to allow continuous well drilling and it must degrade and leave the fractures open for water at later times when exposed to temperatures above 200oC. The sealer showed good compatibility with the mud. Even the blend of 80/20 vol.% of sealer/mud reached a compressive strength of more than 2000 psi set as one of the material criteria, mostly due to the additional activation of the slag and Class C fly ash by the alkaline ingredient present in the drilling fluid. In contrast, the drilling fluid was detrimental to the compressive strength development in conventional Class G well cement, so that it failed to meet this criterion. Among several organic fibers tested both polyvinyl alcohol (PVA)-and nylon-based fibers showed adequate plugging of the sealer in slot nozzles of 1-in. wide x 6-in. long x 0.08 in. and 0.24 in. high under pressures up to 700 psi. PVA fibers displayed better compressive toughness and self-degrading properties than nylon. The compressive toughness of sealers made by adding 1.0 wt% 6 mm-length PVA and 0.5 wt% 19 mm-length PVA was 9.5-fold higher than that of a non-bridged sealer. One factor governing the development of such high toughness was an excellent adherence of PVA to the SSASC cement. The alkali-catalyzed self-decomposition of PVA at 200°C led to the morphological transformation of the material from a fibrous structure to a microscale flake-like structure that helped the desirable conversion of the sealer into small fragments. In contrast, nylon’s decomposition provided a reticular network structure in the self-degraded sealer resulting in bigger fragments compared against the sealer with PVA. The PVA fiber has a high potential as a self-decomposable bridging additive in the SSASC cement sealer.

15 GEOTHERMAL ENERGY↗