Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Particle model of full-size ITER-relevant negative ion source

This work represents the first attempt to model the full-size ITER-relevant negative ion source including the expansion, extraction, and part of the acceleration regions keeping the mesh size fine enough to resolve every single aperture. The model consists of a 2.5D particle-in-cell Monte Carlo collision representation of the plane perpendicular to the filter field lines. Magnetic filter and electron deflection field have been included and a negative ion current density of j{sub H{sup −}} = 660 A/m{sup 2} from the plasma grid (PG) is used as parameter for the neutral conversion. The driver is not yet included and a fixed ambipolar flux is emitted from the driver exit plane. Results show the strong asymmetry along the PG driven by the electron Hall (E × B and diamagnetic) drift perpendicular to the filter field. Such asymmetry creates an important dis-homogeneity in the electron current extracted from the different apertures. A steady state is not yet reached after 15 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

TINY PORES OBSERVED BY HINODE/SOLAR OPTICAL TELESCOPE

The study of pores, small penumbraless sunspots, can give us a chance to understand how strong magnetic fields interact with convective motions in the photosphere. For a better understanding of this interaction, we investigate the temporal variation of several tiny pores smaller than 2''. These pores were observed by the Solar Optical Telescope on board Hinode on 2006 December 29. We have analyzed the high-resolution spectropolarimetric (SP) data and the G-band filtergrams taken during the observation. Magnetic flux density and Doppler velocities of the pores are estimated by applying the center-of-gravity method to the SP data. The horizontal motions in and around the pores are tracked by adopting the nonlinear affine velocity estimator method to the G-band filter images. As a result, we found the following. (1) The darkness of the pores is positively correlated with the magnetic flux density. (2) Downflows always exist inside and around the pores. (3) The speed of downflows inside the pores is negatively correlated with their darkness. (4) The pores are surrounded by strong downflows. (5) Brightness changes of the pores are correlated with the divergence of mass flow (correlation coefficient >0.9). (6) The pores in the growing phase are associated with the converging flow pattern and the pores in the decay phase with the diverging flow pattern. Our results support the idea that a pore grows as the magnetic flux density increases due to the convergence of ambient mass flow and it decays with the decrease of the flux density due to the diverging mass flow.

79 ASTRONOMY AND ASTROPHYSICS↗

A NUMERICAL METHOD FOR THE VISUALIZATION OF THE Fe XIV EMISSION IN THE SOLAR CORONA USING BROADBAND FILTERS

The goal of this article is to demonstrate how the emission from the Fe XIV 530.3 nm coronal emission line, also known as the green line, can be extracted from images taken during total solar eclipses with commercially available color cameras. This concept is technically feasible because Fe XIV is the brightest optical emission line in the inner corona, and because the sensors of these cameras are retrofitted with a standard Bayer mask, namely, a square grid of spectrally broad (about 100 nm) green, blue, and red filters in the ratio of 2:1:1. The technique presented here, and developed for this purpose, yields qualitatively accurate Fe XIV images, as tested by comparing with Fe XIV eclipse images taken with a 0.15 nm narrow-bandpass filter. While this approach cannot replace narrow-bandpass Fe XIV images for quantitative studies of the corona, it provides a simple and affordable tool for studying the morphology of coronal structures emitting preferentially at the peak ionization temperature of Fe XIV, namely, 1.8 Multiplication-Sign 10{sup 6} K.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of core neutrals using passive measurements of the D α spectrum near the X -point in the DIII-D tokamak

New spectroscopic measurements of deuterium Balmer-α emission are used to infer the spatial distribution of neutral particles near the X-point in a diverted high confinement mode plasma. The charge exchange neutral spectroscopy (CENS) diagnostic—recently installed on the DIII-D tokamak—uses 15 lines of sight extending from the edge of the confined region (ρ ≈ 0.7) to the X-point in lower single-null plasmas. Each CENS line of sight is spectrally resolved around the deuterium Balmer-α wavelength (6561 Å) to measure the Doppler shift, line broadening, and intensity of Dα emission. Thermal line broadening is used to identify emission from neutrals undergoing charge-exchange (CX) with high temperature ions in the confined plasma. This spectral information allows a more accurate determination of the neutral density deeper inside the confined plasma compared to traditional filter-based diagnostics. We present two methods of analyzing CENS measurements: (1) fitting the spectrum from each view-chord separately, and (2) a tomographic method for inverting the neutral density over a 2D region of space using all CENS views collectively. The neutral density profile is found to decay exponentially in the radial direction with two scale-lengths. In the pedestal region the neutral density decays at a rate approximately equal to the local mean-free-path for CX collisions, $L_{n_\mathrm{D0}}\approx \lambda_\text{CX}$. Further inside the plasma the neutral density decays at a rate equal to the mean-free-path for ionization, $L_{n_\mathrm{D0}}\approx \lambda_\text{inz.}$. The separatrix $n_\mathrm{D0}$ value is found to be approximately $2\times10^{15}$ m−3. Based on results from the 2D inversion, the density of neutrals is found to increase along the separatrix approaching the X-point by a factor of $\approx 5\times$ over the region covered by the CENS diagnostic.

X-point neutrals↗

Unidentified gamma-ray sources as targets for indirect dark matter detection with the Fermi -Large Area Telescope

We report that one of the predictions of the ΛCDM cosmological framework is the hierarchical formation of structure, giving rise to dark matter (DM) halos and subhalos. When the latter are massive enough they retain gas (i.e., baryons) and become visible. This is the case of the dwarf satellite galaxies in the Milky Way (MW) . Below a certain mass, halos may not accumulate significant amounts of baryons and remain completely dark. However, if DM particles are Weakly Interacting Massive Particles (WIMPs), we expect them to annihilate in subhalos, producing gamma rays which can be detected with the Fermi satellite. Using the three most recent point-source Fermi Large Area Telescope (LAT) catalogs (3FGL, 2FHL and 3FHL), we search for DM subhalo candidates among the unidentified sources, i.e., sources with no firm association to a known astrophysical object. We apply several selection criteria based on the expected properties of the DM-induced emission from subhalos, which allow us to significantly reduce the list of potential candidates. Then, by characterizing the minimum detection flux of the instrument and comparing our sample to predictions from the Via Lactea II (VL-II) N-body cosmological simulation, we place conservative and robust constraints on the $\langle$σ v$\rangle$-m DM parameter space. For annihilation via the τ + τ - channel, we put an upper limit of 4 × 10 -26 (5 × 10 -25 ) cm 3 s -1 for a mass of 10 (100) GeV . A critical improvement over previous treatments is the repopulation we made to include low-mass subhalos below the VL\nobreakdash-II mass resolution. Finally, with more advanced subhalo candidate filtering the sensitivity reach of our method can potentially improve these constraints by a factor 3 (2) for τ + τ - (b $\bar{b}$ ) channel.

79 ASTRONOMY AND ASTROPHYSICS↗

The Medical Science DMZ

Objective We describe use cases and an institutional reference architecture for maintaining high-capacity, data-intensive network flows (e.g., 10, 40, 100 Gbpsþ) in a scientific, medical context while still adhering to security and privacy laws and regulations. Materials and Methods High-end networking, packet filter firewalls, network intrusion detection systems. Results We describe a “Medical Science DMZ” concept as an option for secure, high-volume transport of large, sensitive data sets between research institutions over national research networks. Discussion The exponentially increasing amounts of “omics” data, the rapid increase of high-quality imaging, and other rapidly growing clinical data sets have resulted in the rise of biomedical research “big data.” The storage, analysis, and network resources required to process these data and integrate them into patient diagnoses and treatments have grown to scales that strain the capabilities of academic health centers. Some data are not generated locally and cannot be sustained locally, and shared data repositories such as those provided by the National Library of Medicine, the National Cancer Institute, and international partners such as the European Bioinformatics Institute are rapidly growing. The ability to store and compute using these data must therefore be addressed by a combination of local, national, and industry resources that exchange large data sets. Maintaining data-intensive flows that comply with HIPAA and other regulations presents a new challenge for biomedical research. Recognizing this, we describe a strategy that marries performance and security by borrowing from and redefining the concept of a “Science DMZ”—a framework that is used in physical sciences and engineering research to manage high-capacity data flows. Conclusion By implementing a Medical Science DMZ architecture, biomedical researchers can leverage the scale provided by high-performance computer and cloud storage facilities and national high-speed research networks while preserving privacy and meeting regulatory requirements.

97 MATHEMATICS AND COMPUTING↗

Validation of CT dose-reduction simulation

The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The ''just noticeable difference (JND)'' in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p>0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6%{+-}1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1%{+-}1.6%. Cadaver measurements indicated that image noise was matched to within 2.6%{+-}2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p=0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose, which is far larger than the noise accuracy achieved by simulation. In summary, the dose-reduction simulation tool demonstrated excellent accuracy in providing realistic images. The methodology promises to be a useful tool for researchers and radiologists to explore dose reduction protocols in an effort to produce diagnostic images with radiation dose ''as low as reasonably achievable.''.

61 RADIATION PROTECTION AND DOSIMETRY↗

Smoothing of respiratory motion traces for motion-compensated radiotherapy

Purpose: The CyberKnife system has been used successfully for several years to radiosurgically treat tumors without the need for stereotactic fixation or sedation of the patient. It has been shown that tumor motion in the lung, liver, and pancreas can be tracked with acceptable accuracy and repeatability. However, highly precise targeting for tumors in the lower abdomen, especially for tumors which exhibit strong motion, remains problematic. Reasons for this are manifold, like the slow tracking system operating at 26.5 Hz, and using the signal from the tracking camera ''as is''. Since the motion recorded with the camera is used to compensate for system latency by prediction and the predicted signal is subsequently used to infer the tumor position from a correlation model based on x-ray imaging of gold fiducials around the tumor, camera noise directly influences the targeting accuracy. The goal of this work is to establish the suitability of a new smoothing method for respiratory motion traces used in motion-compensated radiotherapy. The authors endeavor to show that better prediction--With a lower rms error of the predicted signal--and/or smoother prediction is possible using this method. Methods: The authors evaluated six commercially available tracking systems (NDI Aurora, PolarisClassic, Polaris Vicra, MicronTracker2 H40, FP5000, and accuTrack compact). The authors first tracked markers both stationary and while in motion to establish the systems' noise characteristics. Then the authors applied a smoothing method based on the a trous wavelet decomposition to reduce the devices' noise level. Additionally, the smoothed signal of the moving target and a motion trace from actual human respiratory motion were subjected to prediction using the MULIN and the nLMS{sub 2} algorithms. Results: The authors established that the noise distribution for a static target is Gaussian and that when the probe is moved such as to mimic human respiration, it remains Gaussian with the exception of the FP5000 and the Aurora systems. The authors also showed that the proposed smoothing method can indeed be used to filter noise. The signal's jitter dropped by as much as 95% depending on the tracking system employed. Subsequently, the 3D prediction error (rms) for a prediction horizon of 150 ms on a synthetic signal dropped by up to 37% when using a normalized LMS prediction algorithm (nLMS{sub 2}) and hardly changed when using a MULIN algorithm. When smoothing a real signal obtained in our laboratory, the improvement of prediction was similar: Up to 30% for both the nLMS{sub 2} and the best MULIN algorithm. The authors also found a noticeable increase in smoothness of the predicted signal, the relative jitter dropped by up to 95% on the real signal, and on the simulated signal. Conclusions: In conclusion, the authors can say that preprocessing of marker data is very useful in motion-compensated radiotherapy since the quality of prediction increases. This will result in better performance of the correlation model. As a side effect, since the prediction of a preprocessed signal is also less noisy, the authors expect less robot vibration resulting in better targeting accuracy and less strain on the robot gears.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Piecewise-Constant-Model-Based Interior Tomography Applied to Dentin Tubules

Dentin is a hierarchically structured biomineralized composite material, and dentin’s tubules are difficult to study in situ. Nano-CT provides the requisite resolution, but the field of view typically contains only a few tubules. Using a plate-like specimen allows reconstruction of a volume containing specific tubules from a number of truncated projections typically collected over an angular range of about 140°, which is practically accessible. Classical computed tomography (CT) theory cannot exactly reconstruct an object only from truncated projections, needless to say a limited angular range. Recently, interior tomography was developed to reconstruct a region-of-interest (ROI) from truncated data in a theoretically exact fashion via the total variation (TV) minimization under the condition that the ROI is piecewise constant. In this paper, we employ a TV minimization interior tomography algorithm to reconstruct interior microstructures in dentin from truncated projections over a limited angular range. Compared to the filtered backprojection (FBP) reconstruction, our reconstruction method reduces noise and suppresses artifacts. Volume rendering confirms the merits of our method in terms of preserving the interior microstructure of the dentin specimen.

59 BASIC BIOLOGICAL SCIENCES↗

SIRT-FILTER v1.0.0

Small Python package to compute tomographic reconstructions using a reconstruction method published in: Pelt, D.M., & De Andrade, V. (2017). Improved tomographic reconstruction of large-scale real-world data by filter optimization. Advanced Structural and Chemical Imaging 2: 17; and Pelt, D. M., & Batenburg, K. J. (2015). Accurately approximating algebraic tomographic reconstruction by filtered backprojection. In Proceedings of The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (pp. 158-161).

PELT, DANIEL↗

THE KEPLER CATALOG OF STELLAR FLARES

A homogeneous search for stellar flares has been performed using every available Kepler light curve. An iterative light curve de-trending approach was used to filter out both astrophysical and systematic variability to detect flares. The flare recovery completeness has also been computed throughout each light curve using artificial flare injection tests, and the tools for this work have been made publicly available. The final sample contains 851,168 candidate flare events recovered above the 68% completeness threshold, which were detected from 4041 stars, or 1.9% of the stars in the Kepler database. The average flare energy detected is ∼10{sup 35} erg. The net fraction of flare stars increases with g − i color, or decreasing stellar mass. For stars in this sample with previously measured rotation periods, the total relative flare luminosity is compared to the Rossby number. A tentative detection of flare activity saturation for low-mass stars with rapid rotation below a Rossby number of ∼0.03 is found. A power-law decay in flare activity with Rossby number is found with a slope of −1, shallower than typical measurements for X-ray activity decay with Rossby number.

79 ASTRONOMY AND ASTROPHYSICS↗

Precipitation mapping with an airborne synthetic aperture imaging radar

Use of an airborne synthetic-aperture radar (SAR) of 3.1-cm wavelength for the detection and mapping of precipitation echoes is described. Difficulties in mapping related to the incoherence of the echoes are discussed; methods of increasing resolution by Doppler filtering are suggested. Observations made with a vertical side-looking SAR system flying above a stratiform storm were found to resemble vertical cross sections obtained with conventional radar showing snow streamers, the bright band and rain. However, the actual section sampled by the SAR after filtering for zero Doppler is shown to depend upon both the relative motion of the particles and the relative winds below the aircraft. Knowledge of the relative winds, deduced from Doppler spectrum variations, and of the particle fall speeds permits the generation of horizontal and vertical cross sections displaced from the aircraft's position.

Atlas, D.↗

Analysis of time dependent phenomena observed with the LPSP OSO-8 instrument

Data obtained by the Laboratoire de Physique Stellaire et Planetaire's ultraviolet spectrometer onboard the OSO-8 spacecraft were analyzed in an effort to dynamically model the solar chromosphere as an aid in enhancing knowledge of the dynamical processes themselves and of spectral line formation in the dynamic chromosphere. Repeated spectral scans of strong, optically thick resonance lines formed in the solar chromosphere were examined for indications of oscillatory velocities and intensities among other indications of velocity which were studied, the blue peak is reasonably well defined, and the position of a parabolic filter fitted by the least squares method was used to define it. Observed chromospheric oscillation periods are discussed as well as the variations in altitude of the emitting region which result primarily from the motion up and down during the oscillation.

Leibacher, J. W.↗

Fast algorithm for calculating chemical kinetics in turbulent reacting flow

This paper addresses the need for a fast batch chemistry solver to perform the kinetics part of a split operator formulation of turbulent reacting flows, with special attention focused on the solution of the ordinary differential equations governing a homogeneous gas-phase chemical reaction. For this purpose, a two-part predictor-corrector algorithm which incorporates an exponentially fitted trapezoidal method was developed. The algorithm performs filtering of ill-posed initial conditions, automatic step-size selection, and automatic selection of Jacobi-Newton or Newton-Raphson iteration for convergence to achieve maximum computational efficiency while observing a prescribed error tolerance. The new algorithm, termed CREK1D (combustion reaction kinetics, one-dimensional), compared favorably with the code LSODE when tested on two representative problems drawn from combustion kinetics, and is faster than LSODE.

Radhakrishnan, K.↗