Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Model optimization using statistical estimation

Program revises initial or prior estimate of stiffness and mass parameters to parameters yielding frequency and mode characteristics in agreement with test data. Variances are also calculated and consequently define uncertainties of final estimates.

Collins, J. D.↗

Apparent motion occurs only between similar spatial frequencies

Whether apparent motion occurs only between targets of similar spatial frequency was examined. A 'crossed phi' method was used, in which two potentially different targets exchange position. If the targets differ in a feature that controls apparent motion then they will appear to move so as to exchange positions; if they differ in an irrelevant feature, no apparent exchange will occur. It was found that apparent motion occurs only between similar spatial frequencies. This result is interpreted in the light of recent models of human visual motion sensing, in which motion estimates are computed separately within a number of spatial frequency bands.

Watson, Andrew B.↗

Single-tone parameter estimation from discrete-time observations

Estimation of the parameters of a single-frequency complex tone from a finite number of noisy discrete-time observations is discussed. The appropriate Cramer-Rao bounds and maximum-likelihood (ML) estimation algorithms are derived. Some properties of the ML estimators are proved. The relationship of ML estimation to the discrete Fourier transform is exploited to obtain practial algorithms. The threshold effect of one algorithm is analyzed and compared to simulation results. Other simulation results verify other aspects of the analysis.

Rife, D. C.↗

Estimation of mass of compact object in H 1743-322 from 2010 and 2011 outbursts using TCAF solution and spectral index–QPO frequency correlation

The well-known black hole candidate (BHC) H 1743-322 exhibited temporal and spectral variabilities during several outbursts. The variation of the accretion rates and flow geometry that change on a daily basis during each of the outbursts can be very well understood using the recent implementation of the two-component advective flow solution of the viscous transonic flow equations as an additive table model in XSPEC. This has dramatically improved our understanding of accretion flow dynamics. Most interestingly, the solution allows us to treat the mass of the BHC as a free parameter and its mass could be estimated from spectral fits. In this paper, we fitted the data of two successive outbursts of H 1743-322 in 2010 and 2011 and studied the evolution of accretion flow parameters, such as two-component (Keplerian and sub-Keplerian) accretion rates, shock location (i.e., size of the Compton cloud), etc. We assume that the model normalization remains the same across the states in both these outbursts. We used this to estimate the mass of the black hole and found that it comes out in the range of 9.25--12.86 M{sub ⊙}. For the sake of comparison, we also estimated mass using the Photon index versus Quasi Periodic Oscillation frequency correlation method, which turns out to be 11.65±0.67 M{sub ⊙} using GRO J1655-40 as a reference source. Combining these two estimates, the most probable mass of the compact object becomes 11.21{sub −1.96}{sup +1.65} M{sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

On detrending stream velocity time series for robust tidal flow turbulence characterization

We investigated the impact of detrending techniques on turbulence quantities from tidal stream flow data, focusing on the autocorrelation function, $ρ_{uu}$, and velocity spectrum, $Φ(f)$. Standard detrending methods, including high-pass frequency-based and polynomial-based techniques, are examined, alongside a proposed alternative method, the empirical mode decomposition (EMD). Our results highlight that intervals of flow acceleration and deceleration, typical in tidal and riverine flows, significantly affect the estimation of turbulence quantities using high-pass frequency filtering and polynomial detrending of varying orders. These methods can strongly influence $ρ_{uu}$ and $Φ(f)$, thereby affecting the accurate estimation of derived quantities. We examine two variations of detrending data using EMD; the first removes only the EMD residue, and the second removes both the residue and the largest scale intrinsic mode function (IMF). By comparing the detrended spectra with the modeled von Kármán spectra, we demonstrate that the second variation (i.e., removing the residue and the largest scale IMF) successfully removed the large-scale trend of the data while retaining the energy of other scales.

Detrend↗

Dusty plasma diagnostics methods for charge, electron temperature, and ion density

Diagnostic methods are developed to measure the microparticle charge Q and two plasma parameters, electron temperature T{sub e}, and ion density n{sub i}, in the main plasma region of a dusty plasma. Using video microscopy to track microparticles yields a resonance frequency, which along with a charging model allows an estimation of Q and T{sub e}. Only measurements of microparticle position and velocity are required, unlike other methods that use measurements of T{sub e} and plasma parameters as inputs. The resonance frequency measurement can also be used with an ion drag model to estimate n{sub i}. These methods are demonstrated using a single-layer dusty plasma suspension under microgravity conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CHANDRA OBSERVATIONS OF NGC 4342, AN OPTICALLY FAINT, X-RAY GAS-RICH EARLY-TYPE GALAXY

Chandra x-ray observations of NGC 4342, a low-stellar mass (M{sub K} = -22.79 mag) early-type galaxy, show luminous, diffuse x-ray emission originating from hot gas with temperature of kT {approx} 0.6 keV. The observed 0.5-2 keV band luminosity of the diffuse x-ray emission within the D{sub 25} ellipse is L{sub 0.5-2keV} = 2.7 Multiplication-Sign 10{sup 39} erg s{sup -1}. The hot gas has a significantly broader distribution than the stellar light, and shows strong hydrodynamic disturbances with a sharp surface brightness edge to the northeast and a trailing tail. We identify the edge as a cold front and conclude that the distorted morphology of the hot gas is produced by ram pressure as NGC 4342 moves through external gas. From the thermal pressure ratios inside and outside the cold front, we estimate the velocity of NGC 4342 and find that it moves supersonically (M {approx} 2.6) toward the northeast. Outside the optical extent of the galaxy, we detect {approx}17 bright (L{sub 0.5-8keV} > or approx. 3 x 10{sup 37} erg s{sup -1}) excess x-ray point sources. The excess sources are presumably LMXBs located in metal-poor globular clusters (GCs) in the extended dark matter halo of NGC 4342. Based on the number of excess sources and the average frequency of bright LMXBs in GCs, we estimate that NGC 4342 may host roughly 850-1700 GCs. In good agreement with this, optical observations hint that NGC 4342 may harbor 1200 {+-} 500 GCs. This number corresponds to a GC specific frequency of S{sub N} = 19.9 {+-} 8.3, which is among the largest values observed in full-size galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

On the appropriateness of applying chi-square distribution based confidence intervals to spectral estimates of helicopter flyover data

The validity of applying chi-square based confidence intervals to far-field acoustic flyover spectral estimates was investigated. Simulated data, using a Kendall series and experimental acoustic data from the NASA/McDonnell Douglas 500E acoustics test, were analyzed. Statistical significance tests to determine the equality of distributions of the simulated and experimental data relative to theoretical chi-square distributions were performed. Bias and uncertainty errors associated with the spectral estimates were easily identified from the data sets. A model relating the uncertainty and bias errors to the estimates resulted, which aided in determining the appropriateness of the chi-square distribution based confidence intervals. Such confidence intervals were appropriate for nontonally associated frequencies of the experimental data but were inappropriate for tonally associated estimate distributions. The appropriateness at the tonally associated frequencies was indicated by the presence of bias error and noncomformity of the distributions to the theoretical chi-square distribution. A technique for determining appropriate confidence intervals at the tonally associated frequencies was suggested.

Rutledge, Charles K.↗

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

A novel technique for real-time estimation of edge pedestal density gradients via reflectometer time delay data

A new model-based technique for fast estimation of the pedestal electron density gradient has been developed. The technique uses ordinary mode polarization profile reflectometer time delay data and does not require direct profile inversion. Because of its simple data processing, the technique can be readily implemented via a Field-Programmable Gate Array, so as to provide a real-time density gradient estimate, suitable for use in plasma control systems such as envisioned for ITER, and possibly for DIII-D and Experimental Advanced Superconducting Tokamak. The method is based on a simple edge plasma model with a linear pedestal density gradient and low scrape-off-layer density. By measuring reflectometer time delays for three adjacent frequencies, the pedestal density gradient can be estimated analytically via the new approach. Using existing DIII-D profile reflectometer data, the estimated density gradients obtained from the new technique are found to be in good agreement with the actual density gradients for a number of dynamic DIII-D plasma conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Instantaneous Frequency Scaling from Rain Attenuation and Optical Disdrometer Measurements at K/Q bands

Rain attenuation is strongly dependent on the rain rate, but also on the rain drop size distribution (DSD). Typically, models utilize an average drop size distribution, such as those developed by Laws and Parsons, or Marshall and Palmer. However, individual rain events may possess drop size distributions which could be significantly different from the average and will impact, for example, fade mitigation techniques which utilize channel performance estimates from a signal at a different frequency. Therefore, a good understanding of the characteristics and variability of the raindrop size distribution is extremely important in predicting rain attenuation and instantaneous frequency scaling parameters on an event-toevent basis. Since June 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have measured the attenuation due to rain in Milan, Italy, on the 20/40 GHz beacon signal broadcast from the Alphasat TDP#5 Aldo Paraboni Q/V-band Payload. Concomitant with these measurements are the measurements of drop size distribution and rain rate utilizing a Thies Clima laser precipitation monitor (disdrometer). In this paper, we discuss the comparison of the predicted rain attenuation at 20 and 40 GHz derived from the drop size distribution data with the measured rain attenuation. The results are compared on statistical and real-time bases. We will investigate the performance of the rain attenuation model, instantaneous frequency scaling, and the distribution of the scaling factor. Further, seasonal rain characteristics will be analysed.

millimeter wave↗

Nonlinear Dynamic Control Derivative Analysis for Aircraft with Application to Transonic Truss-Braced Wing

This paper presents the development of a nonlinear dynamic control derivative estimation method. A nonlinear aerodynamic model is developed to account for the effects of large control surface deflections on aircraft aerodynamic forces and moments. A series of unsteady RANS CFD simulations is performed to simulate the control surface oscillations at various reduced frequencies. The time-domain data are transformed into the frequency-domain data by a Fourier series analysis. Transfer functions of the dynamic control derivatives are then estimated by a frequency-domain regression. The method is applied to the Transonic Truss-Braced Wing (TTBW) to estimate the dynamic control derivatives for the elevator, aileron, and rudder.

Aircraft Control Derivatives↗

Quantifying the Diversification of Hepatitis C Virus (HCV) during Primary Infection: Estimates of the In Vivo Mutation Rate

Hepatitis C virus (HCV) is present in the host with multiple variants generated by its error prone RNA-dependent RNA polymerase. Little is known about the initial viral diversification and the viral life cycle processes that influence diversity. We studied the diversification of HCV during acute infection in 17 plasma donors, with frequent sampling early in infection. To analyze these data, we developed a new stochastic model of the HCV life cycle. We found that the accumulation of mutations is surprisingly slow: at 30 days, the viral population on average is still 46% identical to its transmitted viral genome. Fitting the model to the sequence data, we estimate the median in vivo viral mutation rate is 2.561025 mutations per nucleotide per genome replication (range 1.6–6.261025 ), about 5-fold lower than previous estimates. To confirm these results we analyzed the frequency of stop codons (N = 10) among all possible non-sense mutation targets (M = 898,335), and found a mutation rate of 2.8–3.261025 , consistent with the estimate from the dynamical model. The slow accumulation of mutations is consistent with slow turnover of infected cells and replication complexes within infected cells. This slow turnover is also inferred from the viral load kinetics. Our estimated mutation rate, which is similar to that of other RNA viruses (e.g., HIV and influenza), is also compatible with the accumulation of substitutions seen in HCV at the population level. Our model identifies the relevant processes (long-lived cells and slow turnover of replication complexes) and parameters involved in determining the rate of HCV diversification.

60 APPLIED LIFE SCIENCES↗

A Reversed Impedance-Based Stability Criterion for IBR Grids

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

Overview of the SCEC/USGS Community Stress Drop Validation Study Using the 2019 Ridgecrest Earthquake Sequence

We present initial findings from the ongoing Community Stress Drop Validation Study to compare spectral stress-drop estimates for earthquakes in the 2019 Ridgecrest, California, sequence. This study uses a unified dataset to independently estimate earthquake source parameters through various methods. Stress drop, which denotes the change in average shear stress along a fault during earthquake rupture, is a critical parameter in earthquake science, impacting ground motion, rupture simulation, and source physics. Spectral stress drop is commonly derived by fitting the amplitude-spectrum shape, but estimates can vary substantially across studies for individual earthquakes. Sponsored jointly by the U.S. Geological Survey and the Statewide (previously, Southern) California Earthquake Center our community study aims to elucidate sources of variability and uncertainty in earthquake spectral stress-drop estimates through quantitative comparison of submitted results from independent analyses. The dataset includes nearly 13,000 earthquakes ranging from M 1 to 7 during a two-week period of the 2019 Ridgecrest sequence, recorded within a 1° radius. Here, in this article, we report on 56 unique submissions received from 20 different groups, detailing spectral corner frequencies (or source durations), moment magnitudes, and estimated spectral stress drops. Methods employed encompass spectral ratio analysis, spectral decomposition and inversion, finite-fault modeling, ground-motion-based approaches, and combined methods. Initial analysis reveals significant scatter across submitted spectral stress drops spanning over six orders of magnitude. However, we can identify between-method trends and offsets within the data to mitigate this variability. Averaging submissions for a prioritized subset of 56 events shows reduced variability of spectral stress drop, indicating overall consistency in recovered spectral stress-drop values.

58 GEOSCIENCES↗

Loop current eddy shedding estimated using Geosat altimeter data

A method for extracting periodic signals from altimeter data is applied in the Gulf of Mexico using data from the first two years of the Geosat Exact Repeat Mission. The least squares fitting of selected frequencies of sine and cosine functions to the time series of sea surface height at each point of the Geosat ground track is used to estimate the dominant frequency in the gulf for this time period. Optimal interpolation of the sine and cosine coefficients at the dominant frequency to a uniformly spaced grid allows reconstruction of the time series in the gulf and shows eddies shedding from the Loop Current with a period of approximately 10.5 months, consistent with shedding periods determined from numerical models and analysis of satellite infrared data. This technique is a novel method for investigation of periodic signals in Geosat altimetry and is not severely affected by the data outages present in the time series.

Jacobs, Gregg A.↗

Enhanced vasomotion of cerebral arterioles in spontaneously hypertensive rats

Intrinsic rhythmic changes in the diameter of pial cerebral arterioles (30-70 microns) in anesthetized normotensive and hypertensive rats were assessed in vivo to determine if any significant differences exist between the two strains. All diameter measurements were analyzed using a traditional graphic analysis technique and a new frequency spectrum analysis technique known as the Prony Spectral Line Estimator. Graphic analysis of the data revealed that spontaneously hypertensive rats (SHR) possess a significantly greater fundamental frequency (5.57 +/- 0.28 cycles/min) of vasomotion compared to the control Wistar-Kyoto normotensive rats (WKY) (1.95 +/- 0.37 cycles/min). Furthermore, the SHR cerebral arterioles exhibited a significantly greater amplitude of vasomotion (10.07 +/- 0.70 microns) when compared to the WKY cerebral arterioles of the same diameter (8.10 +/- 0.70 microns). Diameter measurements processed with the Prony technique revealed that the fundamental frequency of vasomotion in SHR cerebral arterioles (6.14 +/- 0.39 cycles/min) was also significantly greater than that of the WKY cerebral arterioles (2.99 +/- 0.42 cycles/min). The mean amplitudes of vasomotion in the SHR and WKY strains obtained by the Prony analysis were found not to be statistically significant in contrast to the graphic analysis of the vasomotion amplitude of the arterioles. In addition, the Prony system was able to consistently uncover a very low frequency of vasomotion in both strains of rats that was typically less than 1 cycle/min and was not significantly different between the two strains. The amplitude of this slow frequency was also not significantly different between the two strains. The amplitude of the slow frequency of vasomotion (less than 1 cycle/min) was not different from the amplitude of the higher frequency (2-6 cycles/min) vasomotion by Prony or graphic analysis. These data suggest that a fundamental intrinsic defect exists in the spontaneously hypertensive rat that may contribute to the pathogenesis of hypertension in these animals.

NASA Discipline Cardiopulmonary↗

Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: First patient studies

Purpose: Quantitative cone-beam CT (CBCT) imaging is on increasing demand for high-performance image guided radiation therapy (IGRT). However, the current CBCT has poor image qualities mainly due to scatter contamination. Its current clinical application is therefore limited to patient setup based on only bony structures. To improve CBCT imaging for quantitative use, we recently proposed a correction method using planning CT (pCT) as the prior knowledge. Promising phantom results have been obtained on a tabletop CBCT system, using a correction scheme with rigid registration and without iterations. More challenges arise in clinical implementations of our method, especially because patients have large organ deformation in different scans. In this paper, we propose an improved framework to extend our method from bench to bedside by including several new components. Methods: The basic principle of our correction algorithm is to estimate the primary signals of CBCT projections via forward projection on the pCT image, and then to obtain the low-frequency errors in CBCT raw projections by subtracting the estimated primary signals and low-pass filtering. We improve the algorithm by using deformable registration to minimize the geometry difference between the pCT and the CBCT images. Since the registration performance relies on the accuracy of the CBCT image, we design an optional iterative scheme to update the CBCT image used in the registration. Large correction errors result from the mismatched objects in the pCT and the CBCT scans. Another optional step of gas pocket and couch matching is added into the framework to reduce these effects. Results: The proposed method is evaluated on four prostate patients, of which two cases are presented in detail to investigate the method performance for a large variety of patient geometry in clinical practice. The first patient has small anatomical changes from the planning to the treatment room. Our algorithm works well even without the optional iterations and the gas pocket and couch matching. The image correction on the second patient is more challenging due to the effects of gas pockets and attenuating couch. The improved framework with all new components is used to fully evaluate the correction performance. The enhanced image quality has been evaluated using mean CT number and spatial nonuniformity (SNU) error as well as contrast improvement factor. If the pCT image is considered as the ground truth, on the four patients, the overall mean CT number error is reduced from over 300 HU to below 16 HU in the selected regions of interest (ROIs), and the SNU error is suppressed from over 18% to below 2%. The average soft-tissue contrast is improved by an average factor of 2.6. Conclusions: We further improve our pCT-based CBCT correction algorithm for clinical use. Superior correction performance has been demonstrated on four patient studies. By providing quantitative CBCT images, our approach significantly increases the accuracy of advanced CBCT-based clinical applications for IGRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗