Search NASA⌕ Search

SEARCH · Search NASA

Results for “high performance visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position measurements was equal to 0.79 mm(0.37 mm). The update rate and latency of the FBG-based needle position measurement were 100 and 300 ms, respectively. Conclusions: The FBG-based needle tracking procedure proposed in this paper is able to determine the position of the complete needle, under MR-imaging, with better accuracy and precision, higher update rate, and lower latency compared to current MR-based needle localization methods. This system would be eligible for MR-guided brachytherapy, in particular, for an improved needle guidance and reconstruction.

60 APPLIED LIFE SCIENCES↗

Plant Disease Detection Technology Assessment

Visual inspections by US Customs and Border Protection agriculture specialists have identified approximately 20,000 regulated, quarantined pests each year in agricultural products entering the United States. Most of these pests identified in the Agriculture Quarantine and Inspection (AQI) program are insects. Many pathogens are difficult to detect in agricultural products, particularly in early stages of infection. New technologies can help to detect plant pathogens and the diseases that they cause. This technology assessment was performed for the US Department of Homeland Security Science and Technology Directorate (DHS S&T) through the Food, Agriculture, and Veterinary Defense (FAV-D) program to identify emerging technologies that could address this hard problem. These emerging technologies differ in their diagnostic sensitivities and specificities, as well as in their measurement time and training requirements. New instruments that detect volatile organic compounds characteristic of plant disease or pathogens could provide a less invasive inspection method. Dogs, which can successfully detect many concealed agricultural products, have also been trained to detect some plant pests and pathogens. Simple immunological tests offer sensitive and specific detection of many pathogens at the point of use. Advanced imaging methods that use AI to sort fruits and vegetables and recognize anomalies at high speeds could be used in cooperation with exporters to improve food quality and reduce pests. Advances in nucleic acid–based detection methods that have become gold standards for confirmatory diagnostics are now making those methods available for faster, point-of-use detection. These new methods should be developed in the context of AQI operational requirements, which apply risk-based sampling protocols to protect agriculture and facilitate commerce and passenger transit.

59 BASIC BIOLOGICAL SCIENCES↗

Visualization of the High-Burnup Spent Fuel Rod Phase 1 Test Plan: Technical Memo - Spent Fuel and Waste Disposition (Technical Memo)

Twenty-five high-burnup fuel rods were extracted from seven different fuel assemblies used for power production at the North Anna nuclear power plant and shipped to Oak Ridge National Laboratory (ORNL) in 2016 for detailed non-destructive examination (NDE) and destructive examination (DE). The spent fuel rods were from 17×17 lattices and consist of four cladding types—Zirlo ® , M5 ® , Zircaloy-4, and low tin Zircaloy-4 (Zirc-4). These spent fuel rods are being tested to provide: (a) baseline characterization and mechanical property data that can be used as a comparison to fuel that was loaded into a modified TN-32B cask in November 2017, as part of the high-burnup confirmatory data project and (b) data applicable to high-burnup fuel rods (>45 GWd/MTU) currently stored and to be stored in the dry-cask fleet. The TN-32B cask is referred to as the “Demo” cask and is currently expected to be transported to a separate location and the internal contents inspected in approximately ten years. ORNL has completed the NDE of the twenty-five fuel rods. The purpose of this technical memorandum is to present a simplified summary of the first phase of destructive examinations and test conditions that will be used for communicating with various stakeholders. The destructive examinations will leverage the expertise and capabilities from multiple national laboratories for performing independent measurements of relevant data. Close coordination is required to ensure that all examinations follow well documented procedures and are performed so that measured data and characteristics can be readily compared. Pacific Northwest National Laboratory (PNNL) has published a detailed overview of the test program. ORNL and PNNL developed detailed draft test plans for testing to be performed at their facilities. ORNL and PNNL are in the process of refining these test plans to apply specifically to the testing described in this memorandum. Argonne National Laboratory (ANL) contributed to the ORNL test plan by describing tests to be conducted at ANL. Testing will be based on continuous learning. If a test produces results that are inconsistent with expectations or current trends, further testing will be paused until a path forward is established to understand the results and to identify follow-on testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-situ determination of strain during transient burst testing and the temperature dependence of Zircaloy-4 claddings

Understanding fuel system behavior during postulated loss-of-coolant accidents is pertinent for continued safe and efficient operation of light water reactors, particularly as higher burnups are being pursued and safety margins re-evaluated. Conventional mechanical models for the incumbent Zr alloys typically rely on the assumption that steady-state creep is the dominant fuel cladding response during transient accident conditions. To investigate this assumption, simulated accident burst testing was performed on Zircaloy-4 claddings with balloon behavior measured in-situ. Here, two distinct loading conditions were utilized during burst testing: (1) constant-gas-inventory where pressure was allowed to increase with temperature and (2) constant pressure. In-situ strains and strain rates were measured via 2-dimensional digital image correlation techniques and synchronized with temperature to determine deformation dependencies. The temperature dependence of strain rate was characterized by a two segment Arrhenius relationship, with a distinct transition between the high and low temperature/strain regimes. The average activation energy of the lower temperature/strain regime was 328 ± 25 kJ/mol, in agreement with the ~320 kJ/mol used for conventional LOCA models. However, the higher temperature/strain segment, which encompassed most of ballooning, showed increased activation energies as well as a dependence on whether the burst region was in view. For tests that burst away from the camera view, the average high temperature/strain segment activation energy was 635 ± 150 kJ/mol. For samples where the rupture opening formed in view, the average activation energy was 1015 ± 179 kJ/mol. This observed shift in temperature dependence indicates a transition in deformation mechanism at the end of life, possibly to time independent failure mechanisms, which has not yet been visualized in the literature for Zr alloys. Parameters at the transition points were analyzed to determine thresholds for this change in behavior, which occurred at an average hoop strain of 6.9 ± 2.1 %.

36 MATERIALS SCIENCE↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Tractometry of the Human Connectome Project: resources and insights

The Human Connectome Project (HCP) has become a keystone dataset in human neuroscience, with a plethora of important applications in advancing brain imaging methods and an understanding of the human brain. We focused on tractometry of HCP diffusion-weighted MRI (dMRI) data. We used an open-source software library (pyAFQ; https://yeatmanlab.github.io/pyAFQ) to perform probabilistic tractography and delineate the major white matter pathways in the HCP subjects that have a complete dMRI acquisition (n = 1,041). We used diffusion kurtosis imaging (DKI) to model white matter microstructure in each voxel of the white matter, and extracted tract profiles of DKI-derived tissue properties along the length of the tracts. We explored the empirical properties of the data: first, we assessed the heritability of DKI tissue properties using the known genetic linkage of the large number of twin pairs sampled in HCP. Second, we tested the ability of tractometry to serve as the basis for predictive models of individual characteristics (e.g., age, crystallized/fluid intelligence, reading ability, etc.), compared to local connectome features. To facilitate the exploration of the dataset we created a new web-based visualization tool and use this tool to visualize the data in the HCP tractometry dataset. Finally, we used the HCP dataset as a test-bed for a new technological innovation: the TRX file-format for representation of dMRI-based streamlines. We released the processing outputs and tract profiles as a publicly available data resource through the AWS Open Data program's Open Neurodata repository. We found heritability as high as 0.9 for DKI-based metrics in some brain pathways. We also found that tractometry extracts as much useful information about individual differences as the local connectome method. We released a new web-based visualization tool for tractometry—“Tractoscope” (https://nrdg.github.io/tractoscope). We found that the TRX files require considerably less disk space-a crucial attribute for large datasets like HCP. In addition, TRX incorporates a specification for grouping streamlines, further simplifying tractometry analysis.

59 BASIC BIOLOGICAL SCIENCES↗

An LES study of secondary motion and wall shear stresses in a pipe bend

In this study, large-eddy simulations (LES) of a single-phase, turbulent flow in a 90 ° pipe bend are performed at three Reynolds numbers (5300, 27 000, and 45 000) to investigate the correlation between secondary flow motion and wall shear stresses, which is suspected to be a potential mechanism responsible for material erosion. The isothermal flows are validated against available experimental and numerical data first. The snapshot proper orthogonal decomposition (POD) is applied for the medium and high Reynolds number flows to identify the secondary flow motions and the oscillation of the Dean vortices that are found to cause swirl-switching. Distinguished frequencies of the POD time coefficients at Strouhal numbers of 0.25 and 0.28 are identified for Reynolds numbers at 27 000 and 45 000, respectively. Moreover, shear stress on the pipe wall and the associated power spectral density are obtained and shown to have the same oscillating frequency as the swirl-switching.

42 ENGINEERING↗

Understanding How Ligand Functionalization Influences CO2 and N2 Adsorption in a Sodalite Metal–Organic Framework

In this work, a detailed study is conducted to understand how ligand substitution influences the CO2 and N2 adsorption properties of two highly crystalline sodalite metal–organic frameworks (MOFs) known as Cu–BTT (BTT–3 = 1,3,5-benzenetristetrazolate) and Cu–BTTri (BTTri–3 = 1,3,5-benzenetristriazolate). The enthalpy of adsorption and observed adsorption capacities at a given pressure are significantly lower for Cu–BTTri compared to its tetrazole counterpart, Cu–BTT. In situ X-ray and neutron diffraction, which allow visualization of the CO2 and N2 binding sites on the internal surface of Cu–BTTri, provide insights into understanding the subtle differences. As expected, slightly elongated distances between the open Cu2+ sites and surface-bound CO2 in Cu–BTTri can be explained by the fact that the triazolate ligand is a better electron donor than the tetrazolate. The more pronounced Jahn–Teller effect in Cu–BTTri leads to weaker guest binding. The results of the aforementioned structural analysis were complemented by the prediction of the binding energies at each CO2 and N2 adsorption site by density functional theory calculations. In addition, variable temperature in situ diffraction measurements shed light on the fine structural changes of the framework and CO2 occupancies at different adsorption sites as a function of temperature. Finally, simulated breakthrough curves obtained for both sodalite MOFs demonstrate the materials’ potential performance in dry postcombustion CO2 capture. The simulation, which considers both framework uptake capacity and selectivity, predicts better separation performance for Cu–BTT. The information obtained in this work highlights how ligand substitution can influence adsorption properties and hence provides further insights into the material optimization for important separations.

adsorption capacities↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis

Purpose: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis. Methods: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis. Results: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10{sup −3} and 1.26 × 10{sup −3} mm{sup 2}/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10{sup −3} and 0.91 × 10{sup −3} mm{sup 2}/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%. Conclusions: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm{sup 3}, respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-675: Remote Dosimetry with a Novel PRESAGE Formulation

Purpose: 3D-gel dosimetry provides high-resolution treatment validation; however, scanners aren’t widely available. In remote dosimetry, dosimeters are shipped out from a central base institution to a remote site for irradiation, then shipped back for scanning and analysis, affording a convenient service for treatment validation to institutions lacking the necessary equipment and resources. Previous works demonstrated the high-resolution performance and temporal stability of PRESAGE. Here the newest formulation is investigated for remote dosimetry use. Methods: A new formulation of PRESAGE was created with the aim of improved color stability post irradiation. Dose sensitivity was determined by irradiating cuvettes on a Varian Linac (6MV) from 0–15Gy and measuring change in optical density at 633nm. Sensitivity readings were tracked over time in a temperature control study to determine long-term stability. A large volume study was performed to evaluate the accuracy for remote dosimetry. A 1kg dosimeter was pre-scanned, irradiated on-site with an 8Gy 4field box treatment, post-scanned and shipped to Princess Margaret Hospital for remote reading on an identical scanner. Results: Dose sensitivities ranged from 0.0194–0.0295 ΔOD/(Gy*cm)—similar to previous formulations. Post-irradiated cuvettes stored at 10°C retained 100% initial sensitivity over 5 days and 98.6% over 10 weeks while cuvettes stored at room temperature fell to 95.8% after 5 days and 37.4% after 10 weeks. The immediate and 5-day scans of the 4field box dosimeter data was reconstructed, registered to the corresponding eclipse dose-distribution, and compared with analytical tools in CERR. Immediate and 5-day scans looked visually similar. Line profiles revealed close agreement aside from a slight elevation in dose at the edge in the 5-day readout. Conclusion: The remote dosimetry formulation exhibits excellent temporal stability in small volumes. While immediate and 5-day readout scans of large volume dosimeters show promising agreement, further development is required to reduce an apparent time dependent edge elevation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components (Final Technical Report)

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study. In another approach, we investigate Thermal Tomography (TT), which is a computational method for reconstruction of depth profile of internal material defects from PIT nondestructive evaluation (NDE). TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of subsurface internals defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. Performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shape imported from scanning electron microscopy (SEM) images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on TT images of elliptical defects is capable of classifying shape and orientation of irregular defects. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN. We also investigate several approaches based on Gaussian Random Circle and Bezier Curves for constructing parametric models of irregular-shape defects.

36 MATERIALS SCIENCE↗

Machine Learning-Based Anomaly Detection for PMT Data Quality Monitoring in the SBN and DUNE

Maintaining high-quality detector data is essential for achieving the scientific objectives of the Short-Baseline Neutrino (SBN) Program at Fermilab. Current data quality monitoring (DQM) procedures rely primarily on threshold-based metrics and manual inspection of detector monitoring plots, making the detection of subtle or gradually developing anomalies both time-consuming and dependent on expert interpretation. This project developed and evaluated a machine-learning workflow for automatically identifying anomalous photomultiplier tube (PMT) channels in the Short-Baseline Near Detector (SBND) using optical-hit amplitude data. A Python-based analysis program was developed to process ROOT files, extract statistical features describing individual PMT amplitude distributions, and generate feature vectors for anomaly detection. These features were used to train an Isolation Forest model using data representing normal detector operation. The trained model was subsequently applied to independent detector runs to identify channels exhibiting statistically unusual behavior relative to the learned reference response. To support expert interpretation, the workflow generated complementary diagnostic products, including anomaly score distributions, normalized amplitude comparisons, decision-tree visualizations, and principal component analysis (PCA) projections. This project demonstrated the feasibility of integrating unsupervised machine learning into detector data-quality monitoring and developed a complete workflow for automated PMT performance assessment to aid expert-driven review. Beyond its technical contributions, the VFP appointment fostered a research collaboration between Aurora University and Fermilab and provided direct workforce development benefits by training the visiting faculty member in detector-scale machine-learning methods that are now being incorporated into undergraduate coursework and research. The methodology developed here provides a foundation for future applications to ProtoDUNE and other liquid argon time projection chamber (LArTPC) detectors, contributing to ongoing efforts to improve detector reliability, reduce manual monitoring requirements, and enable scalable data quality monitoring for future large-scale neutrino experiments, including the Deep Underground Neutrino Experiment (DUNE).

Colón Santana, Juan A. [Unlisted, US, IL]↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Enabling immersive simulation.

The object of the 'Enabling Immersive Simulation for Complex Systems Analysis and Training' LDRD has been to research, design, and engineer a capability to develop simulations which (1) provide a rich, immersive interface for participation by real humans (exploiting existing high-performance game-engine technology wherever possible), and (2) can leverage Sandia's substantial investment in high-fidelity physical and cognitive models implemented in the Umbra simulation framework. We report here on these efforts. First, we describe the integration of Sandia's Umbra modular simulation framework with the open-source Delta3D game engine. Next, we report on Umbra's integration with Sandia's Cognitive Foundry, specifically to provide for learning behaviors for 'virtual teammates' directly from observed human behavior. Finally, we describe the integration of Delta3D with the ABL behavior engine, and report on research into establishing the theoretical framework that will be required to make use of tools like ABL to scale up to increasingly rich and realistic virtual characters.

99 GENERAL AND MISCELLANEOUS↗

Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target-stretching, partial-missing, and other motion artifacts in various phases, whereas the 4D-MRI images are visually free of those artifacts. Volume percentage difference for the 6.37 ml target ranged from 5.3% ± 4.3% to 10.3% ± 5.9% for 4D-CT, and 1.47 ± 0.52 to 2.12 ± 1.60 for 4D-MRI. With an increase of respiratory rate, the target volumetric and geometric deviations increase for 4D-CT images while remaining stable for the 4D-MRI images. Target motion amplitude errors at different RRs were measured with a range of 0.66–1.25 mm for 4D-CT and 0.2–0.42 mm for 4D-MRI. The results of Mann–Whitney tests indicated that 4D-MRI significantly outperforms 4D-CT in phase-based target volumetric (p = 0.027) and geometric (p < 0.001) measures. Both modalities achieve equivalent accuracy in measuring motion amplitude (p = 0.828). Conclusions: The k-space self-gated 4D-MRI technique provides a robust method for accurately imaging phase-based target motion and geometry. Compared to 4D-CT, the current 4D-MRI technique demonstrates superior spatiotemporal resolution, and robust resistance to motion artifacts caused by fast target motion and irregular breathing patterns. The technique can be used extensively in abdominal targeting, motion gating, and toward implementing MRI-based adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗