Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Development, characterization and experimental performance of x-ray optics for the LCLS free-electron laser

This manuscript discusses the development of reflective optics for the x-ray offset mirror systems of the Linac Coherent Light Source (LCLS), a 0.15-1.5 nm free-electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC). The unique properties (such as the high peak brightness) of the LCLS FEL beam translate to strict limits in terms of materials choice, thus leading to an x-ray mirror design consisting of a reflective coating deposited on a silicon substrate. Furthermore, the physics requirements for these mirrors result in stringent surface figure and finish specifications that challenge the state-of-the-art in x-ray substrate manufacturing, thin film deposition, and metrology capabilities. Recent experimental results on the development, optimization, and characterization of the LCLS soft x-ray mirrors are presented in this manuscript, including: precision surface metrology on the silicon substrates, and the development of boron carbide reflective coatings with reduced stress and thickness variation < 0.14 nm rms across the 175-mm clear aperture area of the LCLS soft x-ray mirrors.

36 MATERIALS SCIENCE↗

WE-AB-BRB-06: A Temperature Independent Plastic Scintillation Detector Capable of Simultaneous Dose and Temperature Measurement

Purpose: To evaluate a measurement method that renders plastic scintillation detectors temperature independent and capable of recovering dose and temperature information simultaneously. Methods: A novel approach was developed to account for the temperature dependence of plastic scintillation detectors (PSDs) without prior knowledge of the temperature. To enable this, the optical response of the scintillating element is separated into two sub-components, one being the response at a given temperature and the other accounting for the change in the optical emission spectrum with temperature. Using a previously demonstrated hyperspectral approach and following the proper calibration protocol, the contribution to scintillator emission and physical value of both dose and temperature can be obtained in real-time. To validate the method, dose and temperature were measured under cobalt irradiation in a temperature controlled water tank developed for this study. The temperature was varied from 22°C to 42°C. Depth-dose curves were also obtained during irradiations from a linear accelerator, first maintaining the water at room temperature and then warming it to 40°C and letting it cool down naturally over the course of the second measurement. Results: Dose measurements delivered with the Co-60 unit showed an average relative difference to the expected value of (1.0±0.8)%, with a maximum difference of 2.3% over the entire range of temperatures. The measured temperatures using the PSD were all within 1°C of the expected values. The difference between room temperature and warmer depth dose measurements differed by only (1.2±0.4)%. The dosimeter showed to be accurate for temporal resolution down to 0.1s. Conclusion: The proposed method was shown to reliably correct for the temperature dependence of a PSD. Additionally, it makes it possible to assess the temperature at the point of measurement. These are significant advances in PSD technology, particularly in relation to real-time in vivo dosimetry. Part of this research was supported by the Odyssey Program at The University of Texas MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

SU-E-J-02: 4D Digital Tomosynthesis Based On Algebraic Image Reconstruction and Total-Variation Minimization for the Improvement of Image Quality

Purpose: In this paper, we implemented the four-dimensional (4D) digital tomosynthesis (DTS) imaging based on algebraic image reconstruction technique and total-variation minimization method in order to compensate the undersampled projection data and improve the image quality. Methods: The projection data were acquired as supposed the cone-beam computed tomography system in linear accelerator by the Monte Carlo simulation and the in-house 4D digital phantom generation program. We performed 4D DTS based upon simultaneous algebraic reconstruction technique (SART) among the iterative image reconstruction technique and total-variation minimization method (TVMM). To verify the effectiveness of this reconstruction algorithm, we performed systematic simulation studies to investigate the imaging performance. Results: The 4D DTS algorithm based upon the SART and TVMM seems to give better results than that based upon the existing method, or filtered-backprojection. Conclusion: The advanced image reconstruction algorithm for the 4D DTS would be useful to validate each intra-fraction motion during radiation therapy. In addition, it will be possible to give advantage to real-time imaging for the adaptive radiation therapy. This research was supported by Leading Foreign Research Institute Recruitment Program (Grant No.2009-00420) and Basic Atomic Energy Research Institute (BAERI); (Grant No. 2009-0078390) through the National Research Foundation of Korea(NRF) funded by the Ministry of Science, ICT and Future Planning (MSIP)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photonuclear reaction based high-energy x-ray spectrometer to cover from 2 MeV to 20 MeV

A photonuclear-reaction-based hard x-ray spectrometer is developed to measure the number and energy spectrum of fast electrons generated by interactions between plasma and intense laser light. In this spectrometer, x-rays are converted to neutrons through photonuclear reactions, and the neutrons are counted with a bubble detector that is insensitive to x-rays. The spectrometer consists of a bundle of hard x-ray detectors that respond to different photon-energy ranges. Proof-of-principle experiment was performed on a linear accelerator facility. A quasi-monoenergetic electron bunch (N{sub e} = 1.0 × 10{sup −6} C, E{sub e} = 16 ± 0.32 MeV) was injected into a 5-mm-thick lead plate. Bremsstrahlung x-rays, which emanate from the lead plate, were measured with the spectrometer. The measured spectral shape and intensity agree fairly well with those computed with a Monte Carlo simulation code. The result shows that high-energy x-rays can be measured absolutely with a photon-counting accuracy of 50%–70% in the energy range from 2 MeV to 20 MeV with a spectral resolution (Δhν/hν) of about 15%. Quantum efficiency of this spectrometer was designed to be 10{sup −7}, 10{sup −4}, 10{sup −5}, respectively, for 2–10, 11–15, and 15–25 MeV of photon energy ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study the sensitivity of dose calculation in prism treatment planning system using Monte Carlo simulation of 6 MeV electron beam

Prism is a non-commercial Radiotherapy Treatment Planning System (RTPS) develop by Ira J. Kalet from Washington University. Inhomogeneity factor is included in Prism TPS dose calculation. The aim of this study is to investigate the sensitivity of dose calculation on Prism using Monte Carlo simulation. Phase space source from head linear accelerator (LINAC) for Monte Carlo simulation is implemented. To achieve this aim, Prism dose calculation is compared with EGSnrc Monte Carlo simulation. Percentage depth dose (PDD) and R50 from both calculations are observed. BEAMnrc is simulated electron transport in LINAC head and produced phase space file. This file is used as DOSXYZnrc input to simulated electron transport in phantom. This study is started with commissioning process in water phantom. Commissioning process is adjusted Monte Carlo simulation with Prism RTPS. Commissioning result is used for study of inhomogeneity phantom. Physical parameters of inhomogeneity phantom that varied in this study are: density, location and thickness of tissue. Commissioning result is shown that optimum energy of Monte Carlo simulation for 6 MeV electron beam is 6.8 MeV. This commissioning is used R50 and PDD with Practical length (R{sub p}) as references. From inhomogeneity study, the average deviation for all case on interest region is below 5 %. Based on ICRU recommendations, Prism has good ability to calculate the radiation dose in inhomogeneity tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Impact of Breathing Motion in Lung Stereotactic Body Radiotherapy Treatment Using Image-Modulated Radiotherapy and Volumetric Modulated Arc Therapy

Purpose: The objective of this study was to investigate the influence of tumor motion on dose delivery in stereotactic body radiotherapy (SBRT) for lung cancer, using fixed field intensity- modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods and Materials: For each of 10 patients with stage I/II non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was carried out. The internal target volume was delineated on the maximum intensity projection CT, which was reconstructed from the 4DCT dataset. A 5-mm margin was used for generation of the planning target volume. VMAT and five-field IMRT plans were generated using Pinnacle{sup 3} SmartArc and direct machine parameter optimization, respectively. All plans were generated for an Elekta Synergy linear accelerator using 6-MV photons. Simulation was performed to study the interplay between multileaf collimator (MLC) sequences and target movement during the delivery of VMAT and IMRT. For each plan, 4D dose was calculated using deformable image registration of the 4DCT images. Target volume coverage and doses to critical structures calculated using 4D methodology were compared with those calculated using 3D methodology. Results: For all patients included in this study, the interplay effect was found to present limited impact (less than 1% of prescription) on the target dose distribution, especially for SBRT, in which fewer fractions (three fractions) are delivered. Dose to the gross tumor volume (GTV) was, on average, slightly decreased (1% of prescription) in the 4D calculation compared with the 3D calculation. The motion impact on target dose homogeneity was patient-dependent and relatively small. Conclusions: Both VMAT and IMRT plans experienced negligible interplay effects between MLC sequence and tumor motion. For the most part, the 3D doses to the GTV and critical structures provided good approximations of the 4D dose calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of residual target motion for image-tracked spine radiosurgery

A quality assurance method was developed to investigate the effects of residual target motion for hypofractionated spine radiosurgery. The residual target motion (target movement between successive image-guided corrections) was measured on-line via dual x-ray imagers for patients treated with CyberKnife (Accuray, Inc., Sunnyvale, CA), a robotic linear accelerator with intrafractional image-tracking capability. The six degree-of-freedom characteristics of the residual target motion were analyzed, the effects of such motion on patient treatment delivery were investigated by incorporating the probability distribution of the residual motion into the treatment planning dose calculations, and deviations of the doses from those originally planned were calculated. Measurements using a programmable motion phantom were also carried out and compared with the static treatment plan calculations. It was found that the residual target motions were patient specific and typically on the order of 2 mm. The measured dose distributions incorporating the residual target motion also exhibited 2.0 mm discrepancy at the prescription isodose level when compared with the static treatment plan calculations. For certain patients, residual errors introduced significant uncertainties ({approx}1 Gy) for the dose delivered to the spinal cord, especially at the high dose levels covering a small volume of the spinal cord (e.g., 0.1 cc). In such cases, stringent cord constraints and frequent monitoring of the target position should be implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Active Detection and Imaging of Nuclear Materials with High-Brightness Gamma Rays

A Compton scattering {gamma}-ray source, capable of producing photons with energies ranging from 0.1 MeV to 0.9 MeV has been commissioned and characterized, and then used to perform nuclear resonance fluorescence (NRF) experiments. The performances of the two laser systems (one for electron production, one for scattering), the electron photoinjector, and the linear accelerator are also detailed, and {gamma}-ray results are presented. The key source parameters are the size (0.01 mm{sup 2}), horizontal and vertical divergence (6 x 10 mrad{sup 2}), duration (10 ps), spectrum and intensity (10{sup 5} photons/shot). These parameters are summarized by the peak brightness, 1.5 x 10{sup 15} photons/mm{sup 2}/mrad{sup 2}/s/0.1% bandwidth, measured at 478 keV. Additional measurements of the flux as a function of the timing difference between the drive laser pulse and the relativistic photo-electron bunch, {gamma}-ray beam profile, and background evaluations are presented. These results are systematically compared to theoretical models and computer simulations. NRF measurements performed on {sup 7}Li in LiH demonstrate the potential of Compton scattering photon sources to accurately detect isotopes in situ.

42 ENGINEERING↗

Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer

Purpose: Matching the penumbra of a 6 MeV electron beam to the penumbra of a 6 MV photon beam is a dose optimization challenge, especially when the electron beam is applied from an extended source-to-surface distance (SSD), as in the case of some head and neck treatments. Traditionally low melting point alloy blocks have been used to define the photon beam shielding over the spinal cord region. However, these are inherently time consuming to construct and employ in the clinical situation. Multileaf collimators (MLCs) provide a fast and reproducible shielding option but generate geometrically nonconformal approximations to the desired beam edge definition. The effects of substituting Cerrobend for the MLC shielding mode in the context of beam matching with extended-SSD electron beams are the subject of this investigation. Methods: Relative dose beam data from a Varian EX 2100 linear accelerator were acquired in a water tank under the 6 MeV electron beam at both standard and extended-SSD and under the 6 MV photon beam defined by Cerrobend and a number of MLC stepping regimes. The effect of increasing the electron beam SSD on the beam penumbra was assessed. MLC stepping was also assessed in terms of the effects on both the mean photon beam penumbra and the intraleaf dose-profile nonuniformity relative to the MLC midleaf. Computational techniques were used to combine the beam data so as to simulate composite relative dosimetry in the water tank, allowing fine control of beam abutment gap variation. Idealized volumetric dosimetry was generated based on the percentage depth-dose data for the beam modes and the abutment geometries involved. Comparison was made between each composite dosimetry dataset and the relevant ideal dosimetry dataset by way of subtraction. Results: Weighted dose-difference volume histograms (DDVHs) were produced, and these, in turn, summed to provide an overall dosimetry score for each abutment and shielding type/angle combination. Increasing the electron beam SSD increased the penumbra width (defined as the lateral distance of the 80% and 20% isodose contours) by 8-10 mm at the depths of 10-20 mm. Mean photon beam penumbra width increased with increased MLC stepping, and the mean MLC penumbra was {approx_equal}1.5 times greater than that across the corresponding Cerrobend shielding. Intraleaf dose discrepancy in the direction orthogonal to the beam edge also increased with MLC stepping. Conclusions: The weighted DDVH comparison techniques allowed the composite dosimetry resulting from the interplay of the abovementioned variables to be ranked. The MLC dosimetry ranked as good or better than that resulting from beam matching with Cerrobend for all except large field overlaps (-2.5 mm gap). The results for the linear-weighted DDVH comparison suggest that optimal MLC abutment dosimetry results from an optical surface gap of around 1{+-}0.5 mm. Furthermore, this appears reasonably lenient to abutment gap variation, such as that arising from uncertainty in beam markup or other setup errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pygmy dipole strength in {sup 90}Zr

The dipole response of the N=50 nucleus {sup 90}Zr was studied in photon-scattering experiments at the electron linear accelerator ELBE with bremsstrahlung produced at kinetic electron energies of 7.9, 9.0, and 13.2 MeV. We identified 189 levels up to an excitation energy of 12.9 MeV. Statistical methods were applied to estimate intensities of inelastic transitions and to correct the intensities of the ground-state transitions for their branching ratios. In this way we derived the photoabsorption cross section up to the neutron-separation energy. This cross section matches well the photoabsorption cross section obtained from ({gamma}, n) data and thus provides information about the extension of the dipole-strength distribution toward energies below the neutron-separation energy. An enhancement of E1 strength has been found in the range of 6 to 11 MeV. Calculations within the framework of the quasiparticle-phonon model ascribe this strength to a vibration of the excessive neutrons against the N=Z neutron-proton core, giving rise to a pygmy dipole resonance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K{sub sat}) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-38: A Head to Head Comparison of Two Commercial Phantoms Used for SRS QA

Purpose: To compare and contrast two commercial SRS QA phantoms. Methods: Both phantoms were evaluated in terms of their ease of setup as well as the time required to switch inserts for different tests. They were both used to evaluate the coincidence of the radiation and laser isocenters of a linear accelerator. End-to-end dosimetric tests were also performed using both ion chambers and films along two planes through the center of the phantoms. Since one phantom allows for multiple ion chamber orientations, a test was also performed to determine the effect of having the chamber oriented along the radiation beam axis’. Results: Changing inserts took 2 minutes on average for one phantom compared to 5 minutes for the other. The laser/radiation isocenter coincidence as determined from each phantom showed a maximum difference of 0.2mm. Ion chamber results were within 0.5% of the expected values when the chamber was perpendicular to the beams but measured a 3% underdose when the chamber was along the beam direction. Gamma (2%,2mm) pass rates of corresponding films were within 1% between phantoms. Conclusion: The results of the corresponding tests run on both phantoms were comparable, showing that the phantoms were equivalent for the subset of SRS QA tests run here. However, the under dose observed when the chamber was parallel to the beam direction suggests that this configuration should be avoided.

60 APPLIED LIFE SCIENCES↗

WE-A-207-00: In Memoriam of Jacques Ovadia - Reinvigorating Scientific Excellence: Electron Beam Therapy - Past, Present and Future

The Medical Physics community lost one of its early pioneers in radiation oncology physics, Jacques Ovadia, who passed away in April of 2014 at the age of 90. Jacques received his Ph.D. in Nuclear Physics from the University of Illinois at Urbana in 1951. Subsequently, under the guidance of John Laughlin, he was introduced to the field of Medical Physics. When John moved to Memorial Sloan Kettering, Jacques followed him. There he gained clinical experience and expertise in the then cutting-edge field of high energy electron beam therapy. In 1956, Jacques joined Dr. Erich Uhlmann at Michael Reese Hospital in Chicago where one of the country’s first high energy medical linear accelerators had just been installed. During his 35 year tenure, Dr. Ovadia built a strong Medical Physics department that merged in 1984 with that of the University of Chicago. Jacques pioneered the use of high energy electron beams to treat deep seated tumors, multiple-field chest wall irradiation with variable electron energies, and even anticipated the current interest in high energy electron beam grid-therapy. At an early stage, he introduced a simulator, computerized treatment planning and in-house developed record and verify software. He retired in 1990 as Professor emeritus in Radiation and Cellular Biology at the University of Chicago. Dr. Ovadia was an early and strong supporter of AAPM. He was present at the Chicago ROMPS meeting where the decision was made to form an independent professional society for medical physics. He served as AAPM president in 1976. Jacques Ovadia is survived by his wife of 58 years, Florence, their daughter Corinne Graefe and son Marc Ovadia, MD, as well as four grandchildren and one great-grandchild. Jacques’ dynamic and ever enthusiastic personality inspired all who collaborated with him. He will be greatly missed.

60 APPLIED LIFE SCIENCES↗

Small field segments surrounded by large areas only shielded by a multileaf collimator: Comparison of experiments and dose calculation

Purpose: Complex radiotherapy fields delivered using a tertiary multileaf collimator (MLC) often feature small open segments surrounded by large areas of the beam only shielded by the MLC. The aim of this study was to test the ability of two modern dose calculation algorithms to accurately calculate the dose in these fields which would be common, for example, in volumetric modulated arc treatment (VMAT) and study the impact of variations in dosimetric leaf gap (DLG), focal spot size, and MLC transmission in the beam models. Methods: Nine test fields with small fields (0.6-3 cm side length) surrounded by large MLC shielded areas (secondary collimator 12 Multiplication-Sign 12 cm{sup 2}) were created using a 6 MV beam from a Varian Clinac iX linear accelerator with 120 leaf MLC. Measurements of output factors and profiles were performed using a diamond detector (PTW) and compared to two dose calculations algorithms anisotropic analytical algorithm [(AAA) and Acuros XB] implemented on a commercial radiotherapy treatment planning system (Varian Eclipse 10). Results: Both calculation algorithms predicted output factors within 1% for field sizes larger than 1 Multiplication-Sign 1 cm{sup 2}. For smaller fields AAA tended to underestimate the dose. Profiles were predicted well for all fields except for problems of Acuros XB to model the secondary penumbra between MLC shielded fields and the secondary collimator. A focal spot size of 1 mm or less, DLG 1.4 mm and MLC transmission of 1.4% provided a generally good model for our experimental setup. Conclusions: AAA and Acuros XB were found to predict the dose under small MLC defined field segments well. While DLG and focal spot affect mostly the penumbra, the choice of correct MLC transmission will be essential to model treatments such as VMAT accurately.

60 APPLIED LIFE SCIENCES↗

SU-E-T-256: Development of a Monte Carlo-Based Dose-Calculation System in a Cloud Environment for IMRT and VMAT Dosimetric Verification

Purpose: Intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are techniques that are widely used for treating cancer due to better target coverage and critical structure sparing. The increasing complexity of IMRT and VMAT plans leads to decreases in dose calculation accuracy. Monte Carlo simulations are the most accurate method for the determination of dose distributions in patients. However, the simulation settings for modeling an accurate treatment head are very complex and time consuming. The purpose of this work is to report our implementation of a simple Monte Carlo simulation system in a cloud-computing environment for dosimetric verification of IMRT and VMAT plans. Methods: Monte Carlo simulations of a Varian Clinac linear accelerator were performed using the BEAMnrc code, and dose distributions were calculated using the DOSXYZnrc code. Input files for the simulations were automatically generated from DICOM RT files by the developed web application. We therefore must only upload the DICOM RT files through the web interface, and the simulations are run in the cloud. The calculated dose distributions were exported to RT Dose files that can be downloaded through the web interface. The accuracy of the calculated dose distribution was verified by dose measurements. Results: IMRT and VMAT simulations were performed and good agreement results were observed for measured and MC dose comparison. Gamma analysis with a 3% dose and 3 mm DTA criteria shows a mean gamma index value of 95% for the studied cases. Conclusion: A Monte Carlo-based dose calculation system has been successfully implemented in a cloud environment. The developed system can be used for independent dose verification of IMRT and VMAT plans in routine clinical practice. The system will also be helpful for improving accuracy in beam modeling and dose calculation in treatment planning systems. This work was supported by JSPS KAKENHI Grant Number 25861057.

60 APPLIED LIFE SCIENCES↗

Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Combined kV and MV imaging for real-time tracking of implanted fiducial markers

In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is required throughout the beam delivery process. The recent integration of onboard kV diagnostic imaging together with MV electronic portal imaging devices on linear accelerators can allow for real-time three-dimensional (3D) tumor position monitoring during a treatment delivery. The aim of this study is to demonstrate a near real-time 3D internal fiducial tracking system based on the combined use of kV and MV imaging. A commercially available radiotherapy system equipped with both kV and MV imaging systems was used in this work. A hardware video frame grabber was used to capture both kV and MV video streams simultaneously through independent video channels at 30 frames per second. The fiducial locations were extracted from the kV and MV images using a software tool. The geometric tracking capabilities of the system were evaluated using a pelvic phantom with embedded fiducials placed on a moveable stage. The maximum tracking speed of the kV/MV system is approximately 9 Hz, which is primarily limited by the frame rate of the MV imager. The geometric accuracy of the system is found to be on the order of less than 1 mm in all three spatial dimensions. The technique requires minimal hardware modification and is potentially useful for image-guided radiation therapy systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-36: Comparison of CBCT Image Quality for Manufacturer Default Imaging Modes

Purpose CBCT is being increasingly used in patient setup for radiotherapy. Often the manufacturer default scan modes are used for performing these CBCT scans with the assumption that they are the best options. To quantitatively assess the image quality of these scan modes, all of the scan modes were tested as well as options with the reconstruction algorithm. Methods A CatPhan 504 phantom was scanned on a TrueBeam Linear Accelerator using the manufacturer scan modes (FSRT Head, Head, Image Gently, Pelvis, Pelvis Obese, Spotlight, & Thorax). The Head mode scan was then reconstructed multiple times with all filter options (Smooth, Standard, Sharp, & Ultra Sharp) and all Ring Suppression options (Disabled, Weak, Medium, & Strong). An open source ImageJ tool was created for analyzing the CatPhan 504 images. Results The MTF curve was primarily dictated by the voxel size and the filter used in the reconstruction algorithm. The filters also impact the image noise. The CNR was worst for the Image Gently mode, followed by FSRT Head and Head. The sharper the filter, the worse the CNR. HU varied significantly between scan modes. Pelvis Obese had lower than expected HU values than most while the Image Gently mode had higher than expected HU values. If a therapist tried to use preset window and level settings, they would not show the desired tissue for some scan modes. Conclusion Knowing the image quality of the set scan modes, will enable users to better optimize their setup CBCT. Evaluation of the scan mode image quality could improve setup efficiency and lead to better treatment outcomes.

60 APPLIED LIFE SCIENCES↗