Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Sample-morphology effects on x-ray photoelectron peak intensities. II. Estimation of detection limits for thin-film materials

The authors show that the National Institute of Standards and Technology database for the simulation of electron spectra for surface analysis (SESSA) can be used to determine detection limits for thin-film materials such as a thin film on a substrate or buried at varying depths in another material for common x-ray photoelectron spectroscopy (XPS) measurement conditions. Illustrative simulations were made for a W film on or in a Ru matrix and for a Ru film on or in a W matrix. In the former case, the thickness of a W film at a given depth in the Ru matrix was varied so that the intensity of the W 4d{sub 5/2} peak was essentially the same as that for a homogeneous RuW{sub 0.001} alloy. Similarly, the thickness of a Ru film at a selected depth in the W matrix was varied so that the intensity of the Ru 3p{sub 3/2} peak matched that from a homogeneous WRu{sub 0.01} alloy. These film thicknesses correspond to the detection limits of each minor component for measurement conditions where the detection limits for a homogeneous sample varied between 0.1 at. % (for the RuW{sub 0.001} alloy) and 1 at. % (for the WRu{sub 0.01} alloy). SESSA can be similarly used to convert estimates of XPS detection limits for a minor species in a homogeneous solid to the corresponding XPS detection limits for that species as a thin film on or buried in the chosen solid.

36 MATERIALS SCIENCE↗

Radiation Effects on High Thermal Conductivity Fuels (Final Scientific Report)

High thermal conductivity nuclear fuels offer important potential advantages over traditional oxide-based fuels such as higher burnup, reduction in fission gas release, and better overall safety of the reactor system. One interesting approach to high thermal conductivity fuels utilizes high thermal conductivity nonfissile additives to UO 2 fuel to lower the fuel operating temperature and thereby take advantage of the highly favorable radiation resistance of UO 2 at lower operating temperatures. However, differential swelling between the matrix and high conductivity additive phases during high dose irradiation could lead to internal cracking and poor performance. In the current study, ceria (CeO 2 ) and zirconia (ZrO 2 ) surrogate matrices were used to model UO 2 behavior. Al 2 O 3 or SiC in the form of nanoscale powder or platelets, respectively, were used for the high conductivity second phase. The nuclear fuel surrogates were sintered to achieve densities greater than 93% of the ideal values. Scanning electron microscopy (SEM) imaging and X-ray diffraction confirmed the uniform distribution of the second phase and that no intermetallic second phase was formed during sintering. The thermal conductivity of the sintered samples was measured from 50°C to 900°C and revealed an important increase compared to pure CeO2 and ZrO2 pellets. Samples were irradiated with 20 MeV Ni6+ ions at midrange doses ranging from 1 to 15 displacements per atom (dpa) and temperatures from 300°C to 700°C. Post irradiation characterization revealed a good stability of the samples at low to medium doses (1 to 5 dpa) but showed a significant microstructural deterioration and decrease of the mechanical properties at 15 dpa. Although microcracking is not observed at the interface between the matrix and high conductivity phase for any investigated irradiation condition, the strength degradation at 15 dpa suggests that these high thermal conductivity fuel forms may not be suitable for high burnup applications in current or proposed fission reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plasma Biomarker Profiles Differ Depending on Breast Cancer Subtype but RANTES is Consistently Increased

Background: Current biomarkers for breast cancer have little potential for detection. We determined if breast cancer subtypes influence circulating protein biomarkers. Methods: A sandwich-ELISA microarray platform was used to evaluate 23 candidate biomarkers in plasma samples that were obtained from subjects with either benign breast disease or invasive breast cancer. All plasma samples were collected at the time of biopsy, after a referral due to a suspicious screen (e.g., mammography). Cancer samples were evaluated based on breast cancer subtypes, as defined by the HER2 and estrogen receptor statuses. Results: Ten proteins were statistically altered in at least one breast cancer subtype, including four epidermal growth factor receptor ligands, two matrix metalloproteases, two cytokines, and two angiogenic factors. Only one cytokine, RANTES, was significantly increased (P<0.01 for each analysis) in all four subtypes, with areas under receiver operating characteristic curves (AUC) that ranged from 0.76 to 0.82, depending on cancer subtype. The best AUC values were observed for analyses that combined data from multiple biomarkers, with values ranging from 0.70 to 0.99, depending on the cancer subtype. Although the results for RANTES are consistent with previous publications, the multi-assay results need to be validated in independent sample sets. Conclusions: Different breast cancer subtypes produce distinct biomarker profiles, and circulating protein biomarkers have potential to differentiate between true and false positive screens for breast cancer. Impact: Subtype-specific biomarker panels may be useful for detecting breast cancer or as an adjunct assay to improve the accuracy of current screening methods.

59 BASIC BIOLOGICAL SCIENCES↗

Cryogenic Treatment of CoCrFeMnNi(NbC) High-Entropy Alloys

The effect of cryogenic treatment on the microstructure and mechanical properties of CoCrFeMnNi and CoCrFeMnNi(NbC) high-entropy alloys was investigated during annealing. The heat-treated samples were characterized by optical microscopy, scanning electron microscopy–wavelength-dispersive x-ray spectroscopy, x-ray diffraction technique, differential scanning calorimetry, Vickers hardness testing and tensile testing. The results showed a single-phase FCC crystal structure matrix in both alloys during cryogenic treatment and annealing. Cryogenic treatment altered the recrystallization behavior of CoCrFeMnNi high-entropy alloy, while it did not influence the recrystallization of CoCrFeMnNi(NbC) high-entropy alloy. It was also found that cryogenic treatment changed the precipitation behavior of CoCrFeMnNi(NbC) high-entropy alloy during annealing. In both studied high-entropy alloys, the mechanical testing indicated that the cryogenic treatment can effectively reduce the yield strength of cold-rolled samples after annealing. This was primarily attributed to the effect of cryogenic treatment in enhancing crystalline defects annihilation. Furthermore, the cryogenic treatment increased the ultimate tensile strength of CoCrFeMnNi(NbC). A lager plastic deformation and precipitates were considered as the main reasons for the higher ultimate tensile strength.

36 MATERIALS SCIENCE↗

Implantation of sodium ions into germanium

The donor properties of Na atoms introduced by ion implantation into p-Ge with the resistivity 20-40 {Omega} cm are established for the first time. Na profiles implanted into Ge (the energies 70 and 77 keV and the doses (0.8, 3, 30) Multiplication-Sign 10{sup 14} cm{sup -2}) are studied. The doses and annealing temperatures at which the thermoprobe detects n-type conductivity on the sample surface are established. After implantation, the profiles exhibit an extended tail. The depth of the concentration maximum is in good agreement with the calculated mean projected range of Na ions R{sub p}. Annealing for 30 min at temperatures of 250-700 Degree-Sign C brings about a redistribution of Na atoms with the formation of segregation peaks at a depth, which is dependent on the ion dose, and is accompanied by the diffusion of Na atoms to the surface with subsequent evaporation. After annealing at 700 Degree-Sign C less than 7% of the implanted ions remain in the matrix. The shape of the profile tail portions measured after annealing at temperatures 300-400 Degree-Sign C is indicative of the diffusion of a small fraction of Na atoms into the depth of the sample.

36 MATERIALS SCIENCE↗

Measurement of the matrix element for the decay {eta}' {yields} {eta}{pi}0{pi}0 with the GAMS-4{pi} spectrometer

The parameters of the Dalitz diagram for the decay {eta}' {yields} {eta}{pi}0{pi}0 in a generalized and a linear representation were determined by using a statistical sample of 15 x 10{sup 3} events. A charge-exchange reaction at a momentum of 32 GeV/c was a source of monoenergetic {eta}' mesons. The experiment was performed with the aid of the GAMS-4{pi} spectrometer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray Phase Contrast Imaging of the Impact of Multiple HMX Particles in a Polymeric Matrix

The initiation of high explosives (HEs) under shock loading lacks a comprehensive understanding: particularly at the particle scale. One common explanation is the hot spot theory, which suggests that energy in the material resulting from the impact event is localized in a small area causing an increase in temperature that can lead to ignition. This study focuses on the response of HMX particles (a common HE) within a polymer matrix (Sylgard-184 (R)), a simplified example of a polymer-bound explosive (PBX). These PBXs consist of multiple HMX particles in a single polymer-bound sample. A light gas gun was used to load the samples at impact velocities above 400 m/s. The impact events were visualized using X-ray phase-contrast imaging (PCI) allowing real-time observation of the impact event. The experiment used two different types of samples (multi-particle and two crystals) and found evidence of cracking and debonding in both sample types. Additionally, it was found that the multiple particle samples showed similar evidence of damage at lower velocities than that of single particle samples. This is an expected result as the multiple particles add additional interfaces for stress concentration and frictional heating.

42 ENGINEERING↗

Segmentation of RDX and TNT in X‐Ray Computed Tomography Reconstructions of Melt‐Cast Explosives

ABSTRACT Three‐dimensional mesoscale characterization of heterogeneous melt‐cast high explosives is challenging because of the difficulty differentiating binder from explosive crystals: two functionally different materials which are typically similar in density by design. Here, we report an algorithm which can differentiate hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) from 2,4,6‐trinitrotoluene (TNT) in x‐ray computed tomography (CT) volumes with tens of microns resolution. This method allows us to quantify RDX/TNT content, porosity, and RDX domain size. We calibrated the segmentation algorithm using simulated x‐ray CT volumes containing object models of RDX crystals within a TNT matrix. We then segmented and analyzed CT data for Composition B (Comp B), a 60/40 RDX/TNT mixture, and Cyclotol, a 75/25 RDX/TNT mixture. We examined melt‐cast samples fabricated with 100% theoretical maximum density (TMD) and 85% TMD. For the 100% TMD Comp B and Cyclotol samples, the RDX content values calculated by segmentation were 3% and 9% lower, respectively, than the values measured by high‐performance liquid chromatography on material from the same synthesis lots. This result is consistent with the expected underreporting of RDX content resulting from x‐ray CT resolution limits on RDX particles with diameters smaller than 25 µm. The 85% TMD samples were less accurately segmented with our algorithm due to the confounding presence of voids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the Role of Metallic Matrix on Environmentally Assisted Embrittlement of Austempered Ductile Iron (ADI) Using High Si Steel

The objective of this work stems from the environmentally assisted embrittlement suffered by austempered ductile iron (ADI) when its surface is submerged in water. This phenomenon leads to a drop in elongation and ultimate tensile strength of about 75% and 10%, respectively, while the 0.2% offset strain stress remains unaffected. Heat-treating a high Si steel, an ausferritic matrix similar to that present in the ADI under study is obtained, yielding giving a very good combination of tensile strength and elongation. In this manner, it was possible to examine the influence of the metallic matrix such as that present in ADI, though without nodules and cell boundaries, also called last to freeze zones (LTF). Tensile test evaluations on ADI and steel samples under dry and wet conditions were carried out. Additionally, a very specific test, introducing surface cracks, was conducted with the purpose of expanding the current knowledge on this particular kind of fracture. Earlier investigations on ADI have suggested that the process of embrittlement starts in a surface crack generated at the early stages of plastic deformation in LTF zones, which results from the solidification process, where pores, inclusions and unreacted austenite are present. In this manner, water penetrates and weakens the material strength, making the crack grow very fast and leading to an instantaneous samples failure. The main results obtained in this work include the confirmation of the deleterious effect of the LTF zones in the embrittlement process and the fracture surface analysis showing characteristic features of this kind of failure.

36 MATERIALS SCIENCE↗

High pressure synthesis and thermoelectric properties of micro/nano structures CoSb{sub 3}

Nano-particle and defect have been proved to be effective in depressing the lattice thermal conductivity and improving the performance of thermoelectric materials. In this work, In{sub 0.5}Sn{sub x}Co{sub 4}Sb{sub 12} were prepared using a high pressure and high temperature (HPHT) method, In and Sn was assumed that In plays the role of a filler and occupies the Sb-icosahedron voids. Doping of In and Sn results in the defects, nanostructuring, and mesoscale structuring were all combined into a single skutterudite matrix. The thermoelectric properties were measured in the temperature range of 321–710 K. As expected, with the synthetic pressures increased,the thermal conductivity of samples improved significantly. The minimum value of In{sub 0.5}Sn{sub 0.4}Co{sub 4}Sb{sub 12} synthesized at 3.8 GPa is 1.79 Wm{sup −1} K{sup −1} and the highest Seebeck coefficient of sample In{sub 0.5}Sn{sub 0.2}Co{sub 4}Sb{sub 12} synthesized at 2.8 GPa reached 222 μV K{sup −1} finally. - Graphical abstract: Micro/nano structures CoSb{sub 3} could be quickly prepared by HPHT method, the defects, nanostructuring and mesoscale structuring are uniformly distributed in the whole sample. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modification of eutectic Mg2Si in AlMg5Si2Mn alloy by pre-homogenization deformation treatment with different reduction conditions

Highlights: • PHD treatment was proposed to modify Mg{sub 2}Si morphology of extruded AlMg5Si2Mn alloy. • PHD treatment accelerated spheroidization of eutectic Mg{sub 2}Si in AlMg5Si2Mn alloy. • Tensile properties of AlMg5Si2Mn extrudates were improved by introduction of PHD. - Abstract: The effect of a novel pre-homogenization deformation (PHD) treatment on the microstructure and mechanical properties of extruded AlMg5Si2Mn alloy was investigated. By introducing the cold compression prior to homogenization treatment, the brittle and interconnected eutectic Mg{sub 2}Si phase in the as-cast AlMg5Si2Mn alloy transformed into fine and spherical particles uniformly dispersed in the aluminum matrix. As the amount of PHD increased, up to 10%, the size of the Mg{sub 2}Si particles decreased and their sphericity increased in the extruded samples, resulting in a gradual increase in both strength and elongation after heat treatment. The mechanical properties of the PHD-treated AlMg5Si2Mn extrudates were compared with those of materials prepared using various casting and deformation processes, and the potential application to wrought products was discussed.

36 MATERIALS SCIENCE↗

An automated micro-separation system for the chromatographic removal of uranium matrix for trace element analysis by ICP-OES

An automated, miniaturized, off-line separation technique is presented here using an Elemental Scientific Inc. microFAST MC system with UTEVA resin to extract the uranium matrix from its trace element impurities in aqueous media. The collected fractions were analyzed for ~30 trace elements using inductively coupled plasma – optical emission spectroscopy. Ten replicate samples were processed with a single column resulting in precision ranging from 3.3% to 6.2% relative standard deviation with regards to the trace element recoveries. Accuracy, with respect to trace element concentrations in the U 3 O 8 Certified Reference Material 124-1, resulted in an average of 13.9% relative deviation while accuracy to the Canadian U3O8 reference material, CUP-2, resulted in an average relative deviation of 8.6%. In conclusion, the total separation time of this automated process was reduced to ~30 min per sample while employing a 0.5 mL UTEVA chromatographic resin bed and 2.5 mg of uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploiting the Semidestructive Nature of Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry Imaging for Simultaneous Localization and Confident Lipid Annotations

Lipids have been considered as key players in cell signaling and disease. Information on their location and distribution within a biological system, under varying conditions, is necessary to understand the contributions of different lipid species to an altered phenotype. Imaging mass spectrometry techniques, such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and matrix-assisted laser desorption/ionization (MALDI), are capable of revealing global lipid distributions in tissues in an untargeted fashion. Yet, to confidently identify the species present in a sample, orthogonal analyses like tandem MS (MS/MS) are often required. This can be accomplished by bulk sample analysis with liquid chromatography (LC)-MS/MS, which can provide confident lipid identifications, at the expense of losing location-specific information. Here, using planarian flatworms as a model system, we demonstrate that imaging gas cluster ion beam (GCIB)-ToF-SIMS has the unique capability to simultaneously detect, identify, and image lipid species with subcellular resolution in tissue sections. The parallel detection of both, intact lipids and their respective fragments, allows for unique identification of some species without the need of performing an additional orthogonal MS/MS analysis. This was accomplished by correlating intact lipid and associated fragment SIMS images. The lipid assignments, respective fragment identities, and locations gathered from ToF-SIMS data were confirmed via LC-MS/MS on lipid extracts and ultrahigh mass resolution MALDI-MS imaging. Together, these data show that the semidestructive nature of ToF-SIMS can be utilized advantageously to enable both confident molecular annotations and to determine the locations of species within a biological sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phased array performance evaluation with photoelastic visualization

New instrumentation and a widening range of phased array transducer options are affording the industry a greater potential. Visualization of the complex wave components using the photoelastic system can greatly enhance understanding of the generated signals. Diffraction, mode conversion and wave front interaction, together with beam forming for linear, sectorial and matrix arrays, will be viewed using the photoelastic system. Beam focus and steering performance will be shown with a range of embedded and surface targets within glass samples. This paper will present principles and sound field images using this visualization system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetocaloric properties of distilled gadolinium: Effects of structural inhomogeneity and hydrogen impurity

High-purity Gd prepared by distillation is a structurally inhomogeneous system consisting of needle-shaped crystals of cross section 0.5–2.5 μm with near-c-axis orientation embedded in a matrix of nanosized (30–100 nm) grains. By measuring the magnetocaloric effect (MCE) directly, we find that the MCE values differ markedly for the plate-shaped samples cut out of a distillate along and perpendicular to the crystals. The effect of small controlled amounts of impurity (hydrogen) on the properties of distilled Gd is further studied. We observe opposite trends in the MCE response to hydrogen charging with respect to the crystal's orientation within the samples and discuss mechanisms interrelating the unique structural morphology with the impurity behavior. As an overall assessment, the Curie temperatures of α-GdH{sub x} solid solutions increase from 291 K up to 294 K when increasing hydrogen concentration x from 0 to 0.15. Hydrogenation is found to broaden the ferromagnetic-to-paramagnetic phase transition. Hydrogen-containing specimens demonstrate reversibility of MCE at these temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Separation and determination of ultratrace rhenium quantities in molybdenum matrix

The production of very pure molybdenum, free of Re even at ultratrace levels, is extremely important in meeting target purity specifications during the production of 99 Mo for medical applications. Here we propose two methods for separating ultratrace levels of Re from a bulk Mo matrix using either solvent extraction or extraction chromatography, combined with inductively coupled plasma quadrupole mass spectrometry (ICP-MS) detection. Re is extracted (D > 70) from solutions in sulfuric acid as a complex with tri-n-butyl phosphate. Scrubbing and washing steps result in total decontamination factors for Mo up to 1,700 for solvent extraction and 3,500 for extraction chromatography. Re is stripped into a 3 M NH 4 OH matrix and analyzed by ICP-MS. Detection (L D ) and quantification (L Q ) limits were optimized by matrix-matching to allow detection of Re in strip solutions at levels of L D = 0.1 ng Re/g-Mo and L Q = 0.3 ng Re/g-Mo in Mo powder samples. By employing these two extraction methods, excellent recoveries of Re from bulk Mo are achieved, and the L Q is improved by a factor of 5 x 10 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The two-point correlation function covariance with fewer mocks

We present FITCOV an approach for accurate estimation of the covariance of two-point correlation functions that requires fewer mocks than the standard mock-based covariance. This can be achieved by dividing a set of mocks into jackknife regions and fitting the correction term first introduced in Mohammad & Percival (2022), such that the mean of the jackknife covariances corresponds to the one from the mocks. This extends the model beyond the shot-noise limited regime, allowing it to be used for denser samples of galaxies. We test the performance of our fitted jackknife approach, both in terms of accuracy and precision, using lognormal mocks with varying densities and approximate EZmocks mimicking the Dark Energy Spectroscopic Instrument LRG and ELG samples in the redshift range of z = [0.8, 1.1]. We find that the Mohammad–Percival correction produces a bias in the two-point correlation function covariance matrix that grows with number density and that our fitted jackknife approach does not. We also study the effect of the covariance on the uncertainty of cosmological parameters by performing a full-shape analysis. We demonstrate that our fitted jackknife approach based on 25 mocks can recover unbiased and as precise cosmological parameters as the ones obtained from a covariance matrix based on 1000 or 1500 mocks, while the Mohammad–Percival correction produces uncertainties that are twice as large.

79 ASTRONOMY AND ASTROPHYSICS↗