Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Plasma-sheath instability in Hall thrusters due to periodic modulation of the energy of secondary electrons in cyclotron motion

Particle-in-cell simulation of Hall thruster plasmas reveals a plasma-sheath instability manifesting itself as a rearrangement of the plasma sheath near the thruster channel walls accompanied by a sudden change of many discharge parameters. The instability develops when the sheath current as a function of the sheath voltage is in the negative conductivity regime. The major part of the sheath current is produced by beams of secondary electrons counter-streaming between the walls. The negative conductivity is the result of nonlinear dependence of beam-induced secondary electron emission on the plasma potential. The intensity of such emission is defined by the beam energy. The energy of the beam in crossed axial electric and radial magnetic fields is a quasiperiodical function of the phase of cyclotron rotation, which depends on the radial profile of the potential and the thruster channel width. There is a discrete set of stability intervals determined by the final phase of the cyclotron rotation of secondary electrons. As a result, a small variation of the thruster channel width may result in abrupt changes of plasma parameters if the plasma state jumps from one stability interval to another.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma-Sheath Instability in Hall Thrusters Due to Periodic Modulation of the Energy of Secondary Electrons in Cyclotron Motion

Particle-in-cell simulation of Hall thruster plasmas reveals a plasma-sheath instability manifesting itself as a rearrangement of the plasma sheath near the thruster channel walls accompanied by a sudden change of many discharge parameters. The instability develops when the sheath current as a function of the sheath voltage is in the negative conductivity regime. The major part of the sheath current is produced by beams of secondary electrons counter-streaming between the walls. The negative conductivity is the result of nonlinear dependence of beam-induced secondary electron emission on the plasma potential. The intensity of such emission is defined by the beam energy. The energy of the beam in crossed axial electric and radial magnetic fields is a quasi-periodical function of the phase of cyclotron rotation, which depends on the radial profile of the potential and the thruster channel width. There is a discrete set of stability intervals determined by the final phase of the cyclotron rotation of secondary electrons. As a result, a small variation of the thruster channel width may result in abrupt changes of plasma parameters if the plasma state jumps from one stability interval to another.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced mobility of dislocation network nodes and its effect on dislocation multiplication and strain hardening

Understanding plastic deformation of crystals in terms of the fundamental physics of dislocations has remained a grand challenge in materials science for decades. To overcome this, the Discrete Dislocation Dynamics (DDD) method has been developed, but its lack of atomistic resolution leaves open the possibility that certain key mechanisms may be overlooked. Here, by comparing large-scale Molecular Dynamics (MD) with DDD simulations performed under identical conditions we uncover significant discrepancies in the predicted strength and microstructure evolution in BCC crystals under high-strain rate conditions. These are traced to unexpected behaviors of dislocation network nodes forming at dislocation intersections, that can move in ways not previously anticipated as revealed by MD. Once these newfound freedoms of nodal motion are incorporated, DDD simulations begin to closely match plastic evolution observed in MD. This additional mechanism of motion whereby non-screw dislocations can change their glide plane profoundly affects fundamental processes of dislocation multiplication, recovery and storage that define strength of metals.

36 MATERIALS SCIENCE↗

SU-F-J-116: Clinical Experience-Based Verification and Improvement of a 4DCT Program

Purpose: To demonstrate the role of continuous improvement fulfilled by the Medical Physicist in clinical 4DCT and CBCT scanning. Methods: Lung (SABR and Standard) patients’ 4D respiratory motion and image data were reviewed over a 3, 6 and 12 month period following commissioning testing. By identifying trends of clinically relevant parameters and respiratory motions, variables were tested with a programmable motion phantom and assessed. Patient traces were imported to a motion phantom and 4DCT and CBCT imaging were performed. Cos6 surrogate and sup-inf motion was also programmed into the phantom to simulate the long exhale of patients for image contrast tests. Results: Patient surrogate motion amplitudes were 9.9+5.2mm (3–35) at 18+6bpm (6–30). Expiration/Inspiration time ratios of 1.4+0.5second (0.6–2.9) showed image contrast effects evident in the AveCT and 3DCBCT images. Small differences were found for patients with multiple 4DCT data sets. Patient motion assessments were simulated and verified with the phantom within 2mm. Initial image reviews to check for reconstructed artefacts and data loss identified a small number of patients with irregularities in the automatic placement of inspiration and expiration points. Conclusion: The Physicist’s involvement in the continuous improvements of a clinically commissioned technique, processes and workflows continues beyond the commissioning stage of a project. Our experience with our clinical 4DCT program shows that Physics presence is required at the clinical 4DCT scan to assist with technical aspects of the scan and also for clinical image quality assessment prior to voluming. The results of this work enabled the sharing of information from the Medical Physics group with the Radiation Oncologists and Radiation Therapists. This results in an improved awareness of clinical patient respiration variables and how they may affect 4D simulation images and also may also affect the treatment verification images.

60 APPLIED LIFE SCIENCES↗

Star field simulator

A Star Field Simulator has been developed to serve as a source of radiation for the ASTRO Star Tracker. The star tracker and simulator are components of a motion compensation test facility located at Marshall Space Flight Center in Huntsville, Alabama. Preflight tests and simulations using various levels of guide stars are performed in the test facility to establish performance of the motion compensation system before being used in a flight environment. The ASTRO Star Tracker operates over a wide dynamic range of irradiance corresponding to visual stellar magnitudes of -0.8 to 8. A minimum of three simulated guide stars with variable magnitudes are needed to fully test the Star Tracker performance under simulated mission conditions.

Source record↗

A ROS-based Simulator for Testing the Enhanced Autonomous Navigation of the Mars 2020 Rover

In order to achieve the ambitious objectives of the Mars 2020 (M2020) mission, in particular the ability to autonomously traverse more challenging terrains more efficiently, new surface mobility software was developed for Enhanced Navigation (ENav). That decision was made early in the project, before most of the new surface flight software (FSW) existed, which created a need for a separate framework where the new navigation algorithms could be quickly prototyped and tested, before more realistic FSW-based testbeds became available. The JPL robotics team chose the Robot Operating System [1] (ROS) as the environment in which to test the new ENav algorithms. This made it possible to write the algorithms in the C language required by the FSW, so they could be directly ported over to the flight module later on, while leveraging all the C++ libraries and tools provided by ROS for simulation and testing. The ENav algorithms were developed as a separate C library, and stubs were used to replace any FSW-specific code, such as Event Reporting (EVRs) and data products (DPs). A ROS simulator was developed to generate a rich set of varied 3D terrains representative of the candidate Mars landing sites and simulate the physics of the rover motion, the point cloud perceived by the rover’s stereo vision system, and the new thinking-while-driving (TWD) navigation logic which directs the rover to drive autonomously to user-specified waypoints. To simulate the rover motion and perception, a ROS node was developed that uses a software library called HyperDrive Sim (HDSim), which is a wrapper for the Rover Sequencing and Visualization Program [2] (RSVP). That library provides roverterrain settling, realistic slip modelling, and camera rendering capability based on the rover’s NavCam machine vision models. To simulate the navigation logic, a ROS node was created that initializes and runs the ENav algorithms in a way that mimics the FSW execution, while also providing the capability to load and replay data products, including re-running the recorded inputs through the ENav algorithms for testing. An engineering Graphical User Interface (GUI) was also developed to visualize various elements, such as the rover pose during the drive, the simulated and perceived terrain, the selected local and global paths to the goal, the evaluated candidate paths and the reasons why they were rejected, the keep-in and keep-out zones (KIOZs), etc. Finally, an advanced Monte Carlo (MC) framework that can run many simulations in parallel on the Cloud and automatically generate reports that capture the key ENav performance metrics was developed to evaluate the system in a statisticallymeaningful way. This paper provides an overview of the ROSbased simulator used for testing the M2020 ENav algorithms.

Toupet, Olivier↗

Programmatic Advantages of Linear Equivalent Seismic Models

Underground explosions nonlinearly deform the surrounding earth material and can interact with the free surface to produce spall. However, at typical seismological observation distances the seismic wavefield can be accurately modeled using linear approximations. Although nonlinear algorithms can accurately simulate very near field ground motions, they are computationally expensive and potentially unnecessary for far field wave simulations. Conversely, linearized seismic wave propagation codes are orders of magnitude faster computationally and can accurately simulate the wavefield out to typical observational distances. Thus, devising a means of approximating a nonlinear source in terms of a linear equivalent source would be advantageous both for scenario modeling and for interpretation of seismic source models that are based on linear, far-field approximations. This allows fast linear seismic modeling that still incorporates many features of the nonlinear source mechanics built into the simulation results so that one can have many of the advantages of both types of simulations without the computational cost of the nonlinear computation. In this report we first show the computational advantage of using linear equivalent models, and then discuss how the near-source (within the nonlinear wavefield regime) environment affects linear source equivalents and how well we can fit seismic wavefields derived from nonlinear sources.

58 GEOSCIENCES↗

Pre-Shot Simulations of Near-Field and Far-Field Ground Motion for the Source Physics Experiment (SPE) Explosions at the Climax Stock, Nevada National Security Site: SPE3

The Source Physics Experiment (SPE) is designed to improve ground motion prediction capabilities for underground nuclear testing through the development of new physics-based models together with validation via new chemical explosion data. The SPE shots consist of different size and depth chemical explosions in a granite borehole at the Climax Stock on the Nevada National Security Site (NNSS). The third shot in the series (SPE3) will be the same size (1000 kg TNT equivalent) and depth (45 m canister centroid) as the previous shot (SPE2). The main purpose of the SPE3 is to investigate the effects of the damage zone caused by the SPE2 chemical explosion on the SPE3 explosion, keeping all other parameters (e.g. size, depth, explosive type) the same. This SPE3 pre-shot report addresses progress made in simulation of the expected wavefield in the both the near- and the far-field. In this report we consider the far-field to be where seismic wave motion can be characterized by elastic or visco-elastic approximations, in contrast to the near-field where other, often non-linear effects, play a major role. The current simulations build on previous work from the SPE1 and SPE2 shots. The simulations are intended to highlight differences between SPE2 and SPE3 using a variety to approximations intended to mimic the expected effect of the damage zone. The simplest physics of damage zone effects suggest changes in the source region material properties (density, velocity), and in the yield strength (coupling) of the rock, should both impact the far-field signal. We can illustrate this in a simplistic way for P-waves in Figure A using the empirical Mueller-Muphy (1971) far-field explosion model (MM). First if the SPE2 explosion-induced damage reduces velocities and densities without affecting the yield strength or coupling, then by energy conservation the amplitudes for SPE 3 would increase as shown in the top of Figure A. Similarly if the explosion induced damage increased density (say by compacting pore space) the amplitude would decrease. This impedance effect, where the product of the density, wave-velocity, and ground-velocity squared is conserved, is well known. The second and harder effect to quantify, are changes in the energy coupling or yield strength. In the simple MM model this is represented by the coupling factor between cavity radius and yield. If we assume the granite was slightly weakened by SPE2 such that the cavity radius increases slightly then the overall amplitudes of SPE3 decrease relative to SPE2 as shown in the bottom of Figure A. In reality both effects, may exist due to the damage zone, and furthermore we know they are interrelated in complex ways. For S-waves we expect even more complex effects due to motion on joints and faults. For this reason we are developing physics-based near field simulation models coupled to far-field propagation codes to predict the overall effects of changes in the source emplacement region on observed signals. Near-field simulations have been performed using the Eulerian code (GEODYN). An ensemble model, calibrated to match records from past large-scale nuclear events is used. Both 2D axisymmetric (no faults) and fully three-dimensional GEODYN calculations (with /without faults) were conducted in which the damage zones sustained by SPE2 are retained as the initial condition for the SPE3 calculations. The results indicate that the waveform peak amplitudes are slightly decayed since the ensemble model includes no softening mechanism. The pulse widths are reduced, indicating the energy is dissipated more by the damage zone as expected. The dominant motions calculated in all the scenarios are spherically symmetric and non-spherical components are small as seen for the SPE2 calculations. The arrival time of the SPE3 waveform at the boreholes is shorter than SPE2 due to compaction during the previous explosion. As shown in the SPE 1 and 2 observations shear waves are generated, indicating the potential contributions from the induced motion on distributed joints. The effects of joints are evaluated using the Lagrangian hydrocode (GEODYN-L), which was benchmarked against the GEODYN calculations for the ensemble model. A new granite model calibrated for samples from the SPE site is used. The new model includes effects of poroelasticity and water saturation and may be scaled allowing application to both small and large scales. Parametric tests were performed to evaluate the effect of joints within the granite and the results demonstrate that in situ joints introduce anisotropy and significant tangential motions.

58 GEOSCIENCES↗

Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies

Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data: the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for {>=}91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the treatment time and the in-fraction position fluctuation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bioreactor Mass Transport Studies

The objectives of the proposed research efforts were to develop both a simulation tool and a series of experiments to provide a quantitative assessment of mass transport in the NASA rotating wall perfused vessel (RWPV) bioreactor to be flown on EDU#2. This effort consisted of a literature review of bioreactor mass transport studies, the extension of an existing scalar transport computer simulation to include production and utilization of the scalar, and the evaluation of experimental techniques for determining mass transport in these vessels. Since mass transport at the cell surface is determined primarily by the relative motion of the cell assemblage and the surrounding fluid, a detailed assessment of the relative motion was conducted. Results of the simulations of the motion of spheres in the RWPV under microgravity conditions are compared with flight data from EDU#1 flown on STS-70. The mass transport across the cell membrane depends upon the environment, the cell type, and the biological state of the cell. Results from a literature review of cell requirements of several scalars are presented. As a first approximation, a model with a uniform spatial distribution of utilization or production was developed and results from these simulations are presented. There were two candidate processes considered for the experimental mass transport evaluations. The first was to measure the dissolution rate of solid or gel beads. The second was to measure the induced fluorescence of beads as a stimulant (for example hydrogen peroxide) is infused into the vessel. Either technique would use video taped images of the process for recording the quantitative results. Results of preliminary tests of these techniques are discussed.

Kleis, Stanley J.↗

Evaluation of automated decision making methodologies and development of an integrated robotic system simulation: Study results

The implementation of a generic computer simulation for manipulator systems (ROBSIM) is described. The program is written in FORTRAN, and allows the user to: (1) Interactively define a manipulator system consisting of multiple arms, load objects, targets, and an environment; (2) Request graphic display or replay of manipulator motion; (3) Investigate and simulate various control methods including manual force/torque and active compliance control; and (4) Perform kinematic analysis, requirements analysis, and response simulation of manipulamotion. Previous reports have described the algorithms and procedures for using ROBSIM. These reports are superseded and additional features which were added are described. They are: (1) The ability to define motion profiles and compute loads on a common base to which manipulator arms are attached; (2) Capability to accept data describing manipulator geometry from a Computer Aided Design data base using the Initial Graphics exchange Specification format; (3) A manipulator control algorithm derived from processing the TV image of known reference points on a target; and (4) A vocabulary of simple high level task commands which can be used to define task scenarios.

Haley, D. C.↗

SIMULATING PROTOSTELLAR JETS SIMULTANEOUSLY AT LAUNCHING AND OBSERVATIONAL SCALES

We present the first 2.5-dimensional magnetohydrodynamic (MHD) simulations of protostellar jets that include both the region in which the jet is launched magnetocentrifugally at scale lengths <0.1 AU and where the propagating jet is observed at scale lengths >10{sup 3} AU. These simulations, performed with the new adaptive mesh refinement MHD code AZEuS, reveal interesting relationships between conditions at the disk surface, such as the magnetic field strength, and direct observables such as proper motion, jet rotation, jet radius, and mass flux. By comparing these quantities with observed values, we present direct numerical evidence that the magnetocentrifugal launching mechanism is capable, by itself, of launching realistic protostellar jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Software for Simulating a Complex Robot

RoboSim (Robot Simulation) is a computer program that simulates the poses and motions of the Robonaut a developmental anthropomorphic robot that has a complex system of joints with 43 degrees of freedom and multiple modes of operation and control. RoboSim performs a full kinematic simulation of all degrees of freedom. It also includes interface components that duplicate the functionality of the real Robonaut interface with control software and human operators. Basically, users see no difference between the real Robonaut and the simulation. Consequently, new control algorithms can be tested by computational simulation, without risk to the Robonaut hardware, and without using excessive Robonaut-hardware experimental time, which is always at a premium. Previously developed software incorporated into RoboSim includes Enigma (for graphical displays), OSCAR (for kinematical computations), and NDDS (for communication between the Robonaut and external software). In addition, RoboSim incorporates unique inverse-kinematical algorithms for chains of joints that have fewer than six degrees of freedom (e.g., finger joints). In comparison with the algorithms of OSCAR, these algorithms are more readily adaptable and provide better results when using equivalent sets of data.

Goza, S. Michael↗

Nonlinear vs. linear biasing in Trp-cage folding simulations

Biased simulations have great potential for the study of slow processes, including protein folding. Atomic motions in molecules are nonlinear, which suggests that simulations with enhanced sampling of collective motions traced by nonlinear dimensionality reduction methods may perform better than linear ones. In this study, we compare an unbiased folding simulation of the Trp-cage miniprotein with metadynamics simulations using both linear (principle component analysis) and nonlinear (Isomap) low dimensional embeddings as collective variables. Folding of the mini-protein was successfully simulated in 200 ns simulation with linear biasing and non-linear motion biasing. The folded state was correctly predicted as the free energy minimum in both simulations. We found that the advantage of linear motion biasing is that it can sample a larger conformational space, whereas the advantage of nonlinear motion biasing lies in slightly better resolution of the resulting free energy surface. In terms of sampling efficiency, both methods are comparable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of Median Plane Effects in the Extraction Region of the C235 Cyclotron

The Study of beam dynamics in the C235 cyclotron dedicated for proton therapy is presented. Results of computer simulations of the particle motion in the measured magnetic field are given. This of the median plane effects in the extraction region was carried out. The tolerance on the radial component of the magnetic field was defined using these simulations.

43 PARTICLE ACCELERATORS↗

Convective motion in collisionless trapped electron mode turbulence

Global gyrokinetic particle simulation of collisionless trapped electron mode turbulence in toroidal plasmas finds both diffusive and convective electron motion using a Lagrangian analysis. The convective motion is identified using simulation and analytic theory to arise from the conservation of the second invariant when resonant trapped electrons lose kinetic energy to the drift wave. A resonance broadening model fits well the diffusive and convective electron motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗