Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Bench testing of a heterodyne CO 2 laser dispersion interferometer for high temporal resolution plasma density measurements

Here, a heterodyne detection scheme is combined with a 10.59 μm CO 2 laser dispersion interferometer for the first time to allow large bandwidth measurements in the 10-100 MHz range. The approach employed utilizes a 40 MHz acousto-optic cell operating on the frequency doubled CO 2 beam which is obtained using a high 2nd harmonic conversion efficiency orientation patterned gallium arsenide crystal. The measured standard deviation of the line integrated electron density equivalent phase resolution obtained with digital phase demodulation technique, is 4 × 10 17 m –2 . Air flow was found to significantly affect the baseline of the phase signal, which an optical table cover was able to reduce considerably. The heterodyne dispersion interferometer (DI) approach is found to be robustly insensitive to motion, with measured phase shifts below baseline drifts even in the presence of several centimeters of retroreflector induced path length variations. Plasma induced dispersion was simulated with a wedged ZnSe plate and the measured DI phase shifts are consistent with expectations.

47 OTHER INSTRUMENTATION↗

Depth-resolved Laue microdiffraction with coded apertures

A rapid data acquisition and reconstruction method is introduced to image the crystalline structure of materials and the associated strain and orientations at micrometre resolution using Laue diffraction. The method relies on scanning a coded aperture across the diffracted X-ray beam from broadband illumination and a reconstruction algorithm to resolve Laue microdiffraction patterns as a function of depth along the incident illumination path. It provides rapid access to full diffraction information for sub-micrometre volume elements in bulk materials. Both the theory and the experimental validation of this imaging approach are presented in this report.

36 MATERIALS SCIENCE↗

Solvent minimization induces preferential orientation and crystal clustering in serial micro-crystallography on micro-meshes, in situ plates and on a movable crystal conveyor belt

X-ray diffraction data were obtained at the National Synchrotron Light Source from insulin and lysozyme crystals that were densely deposited on three types of surfaces suitable for serial micro-crystallography: MiTeGen MicroMeshes™, Greiner Bio-One Ltd in situ micro-plates, and a moving kapton crystal conveyor belt that is used to deliver crystals directly into the X-ray beam. 6° wedges of data were taken from ~100 crystals mounted on each material, and these individual data sets were merged to form nine complete data sets (six from insulin crystals and three from lysozyme crystals). Insulin crystals have a parallelepiped habit with an extended flat face that preferentially aligned with the mounting surfaces, impacting the data collection strategy and the design of the serial crystallography apparatus. Lysozyme crystals had a cuboidal habit and showed no preferential orientation. Preferential orientation occluded regions of reciprocal space when the X-ray beam was incident normal to the data-collection medium surface, requiring a second pass of data collection with the apparatus inclined away from the orthogonal. In addition, crystals measuring less than 20 µm were observed to clump together into clusters of crystals. Clustering required that the X-ray beam be adjusted to match the crystal size to prevent overlapping diffraction patterns. No additional problems were encountered with the serial crystallography strategy of combining small randomly oriented wedges of data from a large number of specimens. Lastly, high-quality data able to support a realistic molecular replacement solution were readily obtained from both crystal types using all three serial crystallography strategies.

36 MATERIALS SCIENCE↗

Simulations of X-ray diffraction of shock-compressed single-crystal tantalum with synchrotron undulator sources

Polychromatic synchrotron undulator X-ray sources are useful for ultrafast single-crystal diffraction under shock compression. Here, simulations of X-ray diffraction of shock-compressed single-crystal tantalum with realistic undulator sources are reported, based on large-scale molecular dynamics simulations. Purely elastic deformation, elastic–plastic two-wave structure, and severe plastic deformation under different impact velocities are explored, as well as an edge release case. Transmission-mode diffraction simulations consider crystallographic orientation, loading direction, incident beam direction, X-ray spectrum bandwidth and realistic detector size. Diffraction patterns and reciprocal space nodes are obtained from atomic configurations for different loading (elastic and plastic) and detection conditions, and interpretation of the diffraction patterns is discussed.

Tang, M. X.↗

SU-F-T-686: Considerations About Dose Protraction Factor in TCP Calculations for Prostate VMAT Treatments

Purpose: Dose protraction factor should be considered in order to model the TCP calculations. Nevertheless, this study describes a brief discussion showing that the lack of its inclusion should not invalidate these calculations for prostate VMAT treatments. Methods: Dose protraction factor (G) modifies the quadratic term of the linear-quadratic expression in order to take into account the sublethal damage repair of protracting the dose delivery. If the delivery takes a short time (instantaneous), G = 1. For any other dose delivery pattern, G < 1. The Lea-Catcheside dose protraction factor for external beam radiotherapy contains terms depending of on the tissue specific repair parameter (λ) and the irradiation time (T). Expanding the exponential term using a Taylor’s series and neglecting terms of order (λT){sup 3}, the approximation leads to G = 1. The described situation occurs for 3DCRT techniques, where treatment times are about few minutes. For IMRT techniques, fraction times are prolonged compared to 3DCRT times. Wang et al. (2003) and Fowler et al. (2004) investigated the protraction effect with respect to IMRT treatments, reporting clinically significant loss in biological effect associated with IMRT delivery times. Results: Treatment times are noticeably reduced for prostate treatments using VMAT techniques. These times are comparable to 3DCRT times, leading to consider the previous approximation. Conclusion: Dose protraction factor can be approximated by G = 1 in TCP calculations for prostate treatments using VMAT techniques.

60 APPLIED LIFE SCIENCES↗

Calculations on the production and use of superfine holographic X-ray gratings for astrophysical observations

Superfine holograhic X-ray gratings may be produced by transferring onto metal an interference pattern generated by two branches of a sufficiently coherent X-ray beam, emitted in the form of synchrotron radiation from high energy electron storage rings. Generation of the coherent beam requires restrictions on the beam size. A calculation is presented which allows an exact evaluation of this restriction. The effect of defocusing optics on the expected resolution is also studied.

Csonka, P. L.↗

Advanced Communication Technology Satellite (ACTS) multibeam antenna analysis and experiment

One of the most important aspects of a satellite communication system design is the accurate estimation of antenna performance degradation. Pointing error, end coverage gain, peak gain degradation, etc. are the main concerns. The thermal or dynamic distortions of a reflector antenna structural system can affect the far-field antenna power distribution in a least four ways. (1) The antenna gain is reduced; (2) the main lobe of the antenna can be mispointed thus shifting the destination of the delivered power away from the desired locations; (3) the main lobe of the antenna pattern can be broadened, thus spreading the RF power over a larger area than desired; and (4) the antenna pattern sidelobes can increase, thus increasing the chances of interference among adjacent beams of multiple beam antenna system or with antenna beams of other satellites. The in-house developed NASA Lewis Research Center thermal/structural/RF analysis program was designed to accurately simulate the ACTS in-orbit thermal environment and predict the RF antenna performance. The program combines well establish computer programs (TRASYS, SINDA and NASTAN) with a dual reflector-physical optics RF analysis program. The ACTS multibeam antenna configuration is analyzed and several thermal cases are presented and compared with measurements (pre-flight).

Acosta, Roberto J.↗

Phase holograms in polymethyl methacrylate

A procedure is described for the fabrication of complex computer-generated phase holograms in polymethyl methacrylate (PMMA) by means of partial-exposure e-beam lithography and subsequent carefully controlled partial development. Following the development, the pattern appears (rendered in relief) in the PMMA, which then acts as the phase-delay medium. The devices fabricated were designed with 16 equal phase steps per retardation cycle, were up to 3 mm square, and consisted of up to 10 millions of 0.3-2.0-micron square pixels. Data files were up to 60 Mb-long, and the exposure times ranged to several hours. A Fresnel phase lens was fabricated with a diffraction-limited optical performance of 83-percent efficiency.

Maker, P. D.↗

Linearly Tapered Slot Antenna Radiation Characteristics at Millimeter-Wave Frequencies

An endfire travelling wave antenna, such as, a linearly tapered slot antenna (LTSA) is a viable alternative to a patch antenna at millimeter-wave frequencies because of its simple design and ease of fabrication. This paper presents the radiation characteristics of LTSA at higher millimeter-wave frequencies. The measured radiation patterns are observed to be well behaved and symmetric with the main beam in the endfire direction. The measured gain is about 10 dB. The LTSAs have potential wireless applications at 50 GHz, 77 GHz, and 94 GHz.

Simons, Rainee N.↗

Dual beam optical interferometer

A dual beam interferometer device is disclosed that enables moving an optics module in a direction, which changes the path lengths of two beams of light. The two beams reflect off a surface of an object and generate different speckle patterns detected by an element, such as a camera. The camera detects a characteristic of the surface.

Gutierrez, Roman C.↗

Taking SiC Power Devices to the Final Frontier: Addressing Challenges of the Space Radiation Environment

Silicon carbide power device technology has the potential to enable a new generation of aerospace power systems that demand high efficiency, rapid switching, and reduced mass and volume in order to expand space-based capabilities. For this potential to be realized, SiC devices must be capable of withstanding the harsh space radiation environment. Commercial SiC components exhibit high tolerance to total ionizing dose but to date, have not performed well under exposure to heavy ion radiation representative of the on-orbit galactic cosmic rays. Insertion of SiC power device technology into space applications to achieve breakthrough performance gains will require intentional development of components hardened to the effects of these highly-energetic heavy ions. This work presents heavy-ion test data obtained by the authors over the past several years for discrete SiC power MOSFETs, JFETs, and diodes in order to increase the body of knowledge and understanding that will facilitate hardening of this technology to space radiation effects. Specifically, heavy-ion irradiation data taken under different bias, temperature, and ion beam conditions is presented for devices from different manufacturers, and the emerging patterns discussed.

Power semiconductor devices↗

High-Resolution UV Relay Lens for Particle Size Distribution Measurements Using Holography

Shock waves passing through a metal sample can produce ejecta particulates at a metal-vacuum interface. Holography records particle size distributions by using a highpower, short-pulse laser to freeze particle motion. The sizes of the ejecta particles are recorded using an in-line Fraunhofer holography technique. Because the holographic plate would be destroyed in this energetic environment, a high-resolution lens has been designed to relay the interference fringes to a safe environment. Particle sizes within a 12-mm-diameter, 5-mm-thick volume are recorded on holographic film. To achieve resolution down to 0.5 microns, ultraviolet (UV) light (in this case supplied by a tripled Nd:YAG laser) is needed. The design and assembly of a nine-element lens that achieves >2000 lp/mm resolution and operates at f/0.85 will be described. To set up this lens system, a doublet lens is temporarily attached that enables operation with 532-nm (green) light and 1100 lp/mm resolution. Thus, the setup and alignment is performed with green light, but the dynamic recording is done with UV light. During setup, the 532-nm beam provides enough focus shift to accommodate the placement of a resolution pattern outside the ejecta volume; this resolution pattern does not interfere with the calibrated wires and pegs surrounding the ejecta volume. A television microscope archives images of resolution patterns that prove that the calibration wires, interference filter, holographic plate, and relay lenses are in their correct positions. Part of this lens is under vacuum, at the point where the laser illumination passes through a focus. Alignment and tolerancing of this high-resolution lens will be presented, and resolution variation through the 5-mm depth of field will be discussed.

43 PARTICLE ACCELERATORS↗

Mapping mesoscale heterogeneity in the plastic deformation of a copper single crystal

The work reported here is part of a 'multiscale characterization' study of heterogeneous deformation patterns in metals. A copper single crystal was oriented for single slip in the (111)[{bar 1}01] slip system and tested to {approx}10% strain in roughly uniaxial compression. The macroscopic strain field was monitored during the test by optical 'image correlation'. The strain field was measured on orthogonal surfaces, one of which (the x-face) was oriented perpendicular to [1{bar 2}1] and contained the [{bar 1}01] direction of the preferred slip system. The macroscopic strain developed in an inhomogeneous pattern of broad, crossed shear bands in the x-face. One, the primary band, lay parallel to (111). The second, the 'conjugate' band, was oriented perpendicular to (111) with an overall ({bar 1}01) habit that contains no common slip plane of the fcc crystal. The mesoscopic deformation pattern was explored with selected area diffraction, using a focused synchrotron radiation polychromatic beam with a resolution of 1-3 {micro}m. Areas within the primary, conjugate and mixed (primary + conjugate) strain regions of the x-face were identified and mapped for their orientation, excess defect density and shear stress. The mesoscopic defect structure was concentrated in broad, somewhat irregular primary bands that lay nominally parallel to (111) in an almost periodic distribution with a period of about 30 {micro}m. These primary bands were dominant even in the region of conjugate strain. There were also broad conjugate defect bands, almost precisely perpendicular to the primary bands, that tended to bridge primary bands and terminate at them. The residual shear stresses were large (ranging to well above 500 MPa) and strongly correlated with the primary shear bands; interband stresses were small. The maximum resolved shear stresses within the primary bands were oriented out of the plane of the bands, and, hence, could not recover the dislocation structure in the bands. The maximum resolved shear stresses in the interband regions lay predominantly in {l_brace}111{r_brace} planes. The results are compared to the mesoscopic defect patterns found in Cu in etch pit studies done some decades ago, which also revealed a mesoscopic dislocation structure made up of orthogonal bands.

36 MATERIALS SCIENCE↗

Command of active and responsive elastomers by topological defects and patterns

The project resulted in the development of stimuli-responsive elastomer coatings formed by photopolymerized liquid crystal molecules. The molecular orientation of the liquid crystal elastomers is coupled to rubber-like elasticity. The project developed an approach to produce complex patterns of molecular orientation in elastomers by employing photopatterning technique based on plasmonic metamasks that convert unpolarized incoming light into a transmitted light beam with spatially-varying linear polarization. The polarization-modulated light beam aligns the film of azodye molecules, which serves as the substrate for liquid crystal elastomer coating. The alignment of the azodye molecules follows the polarization pattern with a phase shift of the alignment direction by 90 degrees. The azodye substrate imposes orientation of molecules in the adjacent liquid crystal layer which is preserved after the monomers are polymerized into a liquid crystal elastomer. By using differently aligned substrates one could produce various patterns of molecular orientation in the elastomer, which dictate the mechanical properties of the elastomers and their response to external stimuli such as temperature, humidity, and ultraviolet irradiation. In particular, the predesigned molecular orientation produces deterministically defined topography response of the liquid crystal coatings, in which their free surface changes from flat to either locally elevated or locally compressed, depending on whether the pre-inscribed molecular orientation is predesigned with a splay or bend deformation. The research established that the mechanism of this deterministic relation between the dynamic topography and pre-inscribed molecular orientation is rooted in the change of the tensorial order parameter that characterizes the degree of orientational order, and in the contraction/expansion of polymer molecules in response to the order parameter changes. In particular, lowering the order causes contraction of polymer globules. The work demonstrated that the dynamic topography of elastomer coatings with three-dimensional pattern of orientational order includes up and down motion of the material (along the normal to the coating) and also shifts in lateral directions. We demonstrate that the deterministic relationship between the orientational patterns and variations of coatings’ profile is caused by forces that are mathematically equivalent to active forces in the system of “pullers” or “pushers” in active matter, demonstrating universality of the out-of-equilibrium behavior. The project resulted in theoretical models that predictively describe the dynamic response of coatings. The topography of liquid crystal elastomers is sensitive to stimuli such as temperature, ultraviolet irradiation, and humidity. The applicability of the patterned approach to produce dynamic coatings was expanded from nematic elastomers to their smectic counterparts. The project combined a battery of imaging techniques to unveil the dynamic properties of the coatings, ranging from the state-of-the-art dynamic holographic microscopy to fluorescent confocal polarizing microscopy and polscope microscopy. The research uncovered potential applications of dynamic elastomer coatings, such as control placement of colloidal particles, engineering of living tissues with alignment patterns of cells that follow the orientational order of elastomer coatings. The approach developed in the project can be used to design programmable dynamic coatings with functionalities that mimic biological tissues such as skin.

36 MATERIALS SCIENCE↗

Plasma heating, electric fields and plasma flow by electron beam ionospheric injection

The electric fields and the floating potentials of a Plasma Diagnostics Payload (PDP) located near a powerful electron beam injected from a large sounding rocket into the auroral zone ionosphere have been studied. As the PDP drifted away from the beam laterally, it surveyed a region of hot plasma extending nearly to 60 m radius. Large polarization electric fields transverse to B were imbedded in this hot plasma, which displayed large ELF wave variations and also an average pattern which has led to a model of the plasma flow about the negative line potential of the beam resembling a hydrodynamic vortex in a uniform flow field. Most of the present results are derived from the ECHO 6 sounding rocket mission.

Winckler, J. R.↗

Epitaxial growth of diluted magnetic semiconductor Ge{sub 1−x}Cr{sub x}Te with high Cr composition

IV–VI diluted magnetic semiconductor Ge{sub 1−x}Cr{sub x}Te layers up to x = 0.1 were grown on SrF{sub 2} substrates by molecular beam epitaxy. In situ reflection high-energy electron diffraction shows a streaky pattern with a sixfold symmetry in the plane for the Ge{sub 1−x}Cr{sub x}Te layer, implying an epitaxial growth of Ge{sub 1−x}Cr{sub x}Te (111)/SrF{sub 2} (111). A clear hysteresis loop is observed in the anomalous Hall effect measurements due to the strong spin-orbit interaction in the host GeTe. The Curie temperature increases with increasing Cr composition up to 200 K, but there is no clear dependence of the Curie temperature on the hole concentration, implying that the mechanism of the ferromagnetic interaction among Cr ions is different from Mn doped diluted magnetic semiconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Propagation of high power electromagnetic beams in overdense plasmas: Higher order paraxial theory

This article presents the paraxial theory of the propagation of an initially Gaussian electromagnetic beam in an inhomogeneous plasma with an overdense region; in contrast to earlier work on penetration in overdense plasma, higher order terms (up to r{sup 4}) in the expansion of the dielectric function and the eikonal have been taken into account. Three types of nonlinearities, viz., collisional, ponderomotive, and relativistic, have been considered. As expected the higher order terms do not affect the critical curves, corresponding to initial propagation without convergence or divergence. It is seen that the inclusion of higher order terms does significantly affect the dependence of the beam width on the distance of propagation. Corresponding to the case of ponderomotive nonlinearity numerical results for the dependence of beam width parameter and the axial dielectric function on the distance of propagation have been presented for specific values of the initial beam width and axial irradiance and specific spatial dependence of the electron density in the absence of the beam. Both the situations, viz., formation of bright or dark rings in the transverse irradiation pattern, have been considered. From a parametric analysis the dependence of the maximum penetration (when the axial dielectric function tends to zero) on the axial irradiance and an inhomogeneity parameter has been graphically illustrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-kilovolt coherent electron diffractive imaging instrument based on a single-atom electron source

In this work, a transmission-type, low-kilovolt coherent electron diffractive imaging instrument was constructed. It comprised a single-atom field emitter, a triple-element electrostatic lens, a sample holder, and a retractable delay line detector to record the diffraction patterns at different positions behind the sample. It was designed to image materials thinner than 3 nm. The authors analyzed the asymmetric triple-element electrostatic lens for focusing the electron beams and achieved a focused beam spot of 87 nm on the sample plane at the electron energy of 2 kV. High-angle coherent diffraction patterns of a suspended graphene sample corresponding to (0.62 Å){sup −1} were recorded. This work demonstrated the potential of coherent diffractive imaging of thin two-dimensional materials, biological molecules, and nano-objects at a voltage between 1 and 10 kV. The ultimate goal of this instrument is to achieve atomic resolution of these materials with high contrast and little radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗