Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Detecting Unclassified Electromagnetic Signals for Secure Wireless Communication Using Open Set Recognition

We developed multiple machine learning methods for the detection and classification of new wireless communication waveforms, which is critical for targeted attacks in wireless networks and electronic warfare. Our machine learning models are capable of dynamically detecting security threats in near real time through our advanced open set recognition (OSR) approach. This model has demonstrated significant improvements in the detection of unknown waveforms, thereby enhancing the security and reliability of mission critical communications. Our approach to detecting uncertain security threats is novel; we advanced OSR techniques by incorporating domain knowledge of wireless signals. Specifically, we combined time and frequency domain model features to enhance the model’s performance. Utilizing an OSR approach eliminates the need for training data to be distributed similarly to the deployment environment and removes the requirement for the training set to contains all possible threat classes. This is crucial because it is often infeasible to determine and characterize all potential security threats in advance. Our model were trained on simulated data, generated in partnership with the University at Albany, State of New York. The data set contained a diverse array of wireless signals, including those with additive white Gaussian noise and multipath signals, with and without line of sight. This comprehensive training set allowed us to optimize our models to detect unknown waveforms under various challenging scenarios, such as low signal-to-noise ratios. By training on various waveforms, varying signal-to-noise ratio, and different sample sizes under normal conditions, our models were fine tuned to perform effectively in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

The HTR-Proteus Benchmark: Analysis and Use as a Verification and Validation Case

This presentation outlines the evaluation and application of the HTR-Proteus benchmark as a verification and validation (V&V) case for advanced reactor modeling tools. The work supports the U.S. Department of Energy’s HALEU Availability Program (HAP) and the joint DOE/NRC DNCSH project, which aims to reduce criticality safety uncertainties in commercial-scale HALEU fuel cycle and transportation systems. The HTR-Proteus experiments, conducted at the Paul Scherrer Institute, provide high-fidelity data for TRISO-fueled, graphite-moderated pebble bed reactors with high neutron leakage—conditions relevant to HALEU transport scenarios. This study focuses on Cores 4.2 and 4.3 of the HTR-Proteus benchmark, analyzing key sources of uncertainty including pebble packing, TRISO particle positioning, and core height. Using Project Chrono for realistic pebble geometries and Serpent, SHIFT, and MCNP for neutronics simulations, the study quantifies the impact of these uncertainties on the effective multiplication factor (keff). Results show that a sample size of 110 pebble configurations is sufficient to converge keff, with ±30 pcm uncertainty due to packing randomness. TRISO positioning and core height variations also significantly influence keff, highlighting the importance of detailed modeling in V&V efforts. The benchmark serves as a valuable test case for validating the Griffin reactor physics code and improving confidence in HALEU system simulations.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lessons Learned on Benchmarking from the International Human Reliability Analysis Empirical Study

The International Human Reliability Analysis (HRA) Empirical Study is a comparative benchmark of the prediction of HRA methods to the performance of nuclear power plant crews in a control room simulator. There are a number of unique aspects to the present study that distinguish it from previous HRA benchmarks, most notably the emphasis on a method-to-data comparison instead of a method-to-method comparison. This paper reviews seven lessons learned about HRA benchmarking from conducting the study: (1) the dual purposes of the study afforded by joining another HRA study; (2) the importance of comparing not only quantitative but also qualitative aspects of HRA; (3) consideration of both negative and positive drivers on crew performance; (4) a relatively large sample size of crews; (5) the use of multiple methods and scenarios to provide a well-rounded view of HRA performance; (6) the importance of clearly defined human failure events; and (7) the use of a common comparison language to “translate” the results of different HRA methods. These seven lessons learned highlight how the present study can serve as a useful template for future benchmarking studies.

99 GENERAL AND MISCELLANEOUS↗

Measurement of phi(s) and Delta gamma(s) at the Tevatron

We present bounds on the CP violation phase {phi}{sub s} and on the decay width difference {Delta}{Gamma}{sub s} which characterize the neutral B{sub s}{sup 0}-{bar B}{sub s}{sup 0} meson system. The measurements are performed by the CDF and D0 experiments at the Fermilab Tevatron using B{sub s}{sup 0} {yields} J/{Psi}{phi} decays with 2.8 fb{sup -1} of data per experiment. A data sample of 5 fb{sup -1} has already been recorded by each experiment and expect up to doubling this amount by the end of the Tevatron running. Neither of the two Tevatron experiments can provide accurate measurement of the CP violation phase with the current or even expected sample sizes. However they can significantly constrain the allowed parameter space and search for physics beyond the standard model manifested as a large deviation from zero of the CP violation parameter {phi}{sub s}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Capillary Liquid Chromatography-Mass Spectrometry for Proteomics

The liquid chromatography (LC)-mass spectrometric (MS) analysis of peptides has become a routine method for proteomics – the study of the entire complement of proteins e.g., expressed by a cell under a specific set of conditions at a specific time. Mixtures of peptides, such as those generated from enzymatic (e.g., trypsin) digestion of globally recovered proteins (i.e. a proteome), are typically very complex and >100,000 different molecular species may be observable using MS detection [1]. LC separations implemented prior to MS for broad protein identification have three major roles: 1) to isolate individual components or reduce complexity as much as possible, 2) to increase sensitivity by concentrating the components into narrow zones prior to MS, and 3) to eliminate or displace interfering species (e.g., salts and polymers) that may be present in proteomics samples. A desired quality of LC separation can be achieved from the use of either multiple steps of moderate quality separations, or fewer steps of high power separations. The former approach is generally more easily accessible for very high quality separations due to the variety of commercialized LC platforms available, while the latter still often requires considerable developmental efforts (for both columns and instrumentation). In addition to proteomics data quality, other differences between these two approaches include proteomics analysis time and sample consumption (and subsequent analysis costs), as well as direct impact on potential proteomics applications that have special requirements in terms of analysis coverage, sample size, dynamic range, sensitivity, and throughput.

59 BASIC BIOLOGICAL SCIENCES↗

Response characteristics of laser diffraction particle size analyzers - Optical sample volume extent and lens effects

The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.

Hirleman, E. D.↗

Aircraft studies of size-dependent aerosol sampling through inlets

Representative measurement of aerosol from aircraft-aspirated systems requires special efforts in order to maintain near isokinetic sampling conditions, estimate aerosol losses in the sample system, and obtain a measurement of sufficient duration to be statistically significant for all sizes of interest. This last point is especially critical for aircraft measurements which typically require fast response times while sampling in clean remote regions. This paper presents size-resolved tests, intercomparisons, and analysis of aerosol inlet performance as determined by a custom laser optical particle counter. Measurements discussed here took place during the Global Backscatter Experiment (1988-1989) and the Central Pacific Atmospheric Chemistry Experiment (1988). System configurations are discussed including (1) nozzle design and performance, (2) system transmission efficiency, (3) nonadiabatic effects in the sample line and its effect on the sample-line relative humidity, and (4) the use and calibration of a virtual impactor.

Porter, J. N.↗

Size Selectivity of Sampling Gears Used to Sample Kokanee

Abstract Kokanee Oncorhynchus nerka provide valued recreational fisheries and also serve as a prey resource for economically, socially, and ecologically important fishes. As such, management of kokanee is a major focus of natural resource agencies. Kokanee are typically monitored using midwater trawls, but the interpretation of data collected using midwater trawls is difficult due to the unknown size selectivity of the gear. We sought to assess the length selectivity of midwater trawls by comparing estimates obtained from midwater trawls with estimates obtained from gill nets adjusted for size selectivity. Experimental curtain gill nets and midwater trawls were used in conjunction to sample kokanee in seven lentic systems in Idaho. The size selectivity of gill nets was estimated by accounting for the probability of encounter and the probability of retention. Estimates of size selectivity were then used to adjust the length distribution of fish sampled in gill nets. The adjusted length distribution of fish sampled in gill nets was compared with estimates obtained from midwater trawls to identify potential size selectivity of midwater trawls. A pattern of size selectivity was apparent for both sampling techniques. The average length of kokanee sampled with midwater trawls was 111 mm; whereas, kokanee sampled with gill nets had a mean length of 235 mm. Our results suggest experimental gill nets are useful for common sampling of kokanee (e.g., trend monitoring) because the gear is less size selective than midwater trawls and is adjustable for size selectivity. However, midwater trawls are likely the best gear for addressing questions associated with early life history. Overall, our results provide a better understanding of gill-net and midwater trawl selectivity and ultimately improve the ability to sample and manage the species.

Klein, Zachary B.↗

Reduced diffusion and enhanced retention of multiple radionuclides from pore structure characterization of barrier materials for enhanced repository performance

Fluid flow and chemical transport in porous media are the macroscopic consequences of pore structure, which integrates geometry (e.g., pore size and surface area, pore-size distribution) and topology (e.g., pore connectivity). Low-permeability geological media whose pores are poorly interconnected will exhibit the characteristics of anomalous diffusion and sample size-dependent effective porosity, which will strongly impact long-term net diffusion and retention of radionuclides in geological repository settings involving different host rocks and barrier materials. A suite of innovative and complementary experimental approaches is utilized to study the microscopic pore structure and macroscopic fluid flow & chemical transport for a range of host rocks and barrier materials, in addition to standard clay minerals and reference rocks. With a particular focus on quantifying the presence and magnitude of “isolated” pores for a reduced effective porosity in low-permeability geomedia, the integrated methodologies for basic properties and pore structure characterization of these geomedia include X-ray diffraction, thin section petrography, grain size distribution, water immersion porosimetry after vacuum-pulling for full saturation, mercury intrusion porosimetry, nitrogen physisorption, scanning electron microscopy, X-ray computed tomography, and (ultra-)small angle neutron (X-ray) scattering. In addition, custom-designed gas diffusion, tracer recipe involving a range of anionic and cationic chemicals with subsequent analyses by laser ablation and inductively coupled plasma-mass spectrometry, along with batch sorption, column transport, and imbibition tests were conducted for coupled effects of pore structure and chemical retention/transport. From the perspectives of pore structure in conjunction with multiple and complementary approaches to examining a range of sample sizes under different observational scales, we find that the poor pore connectivity is prevalent in low-permeability media (mudstone and crystalline rock) that is related to geological processes (e.g., compaction, diagenesis and thermal maturation). For example, the deep and organic matter-rich mudstones have a much smaller effective porosity than the total porosity (as a result of poor pore connectivity) and associated diffusion coefficient, and the effective porosity & diffusion coefficients are also dependent upon the sample sizes used in the measurement. Similarly, most of the pore space in the shallow mudstone is also controlled by pore-throat diameters in the 5-50 nm range of intergranular pore types from its fine-grained nature, but with an overall good pore connectivity. However, the nm-sized pore space (physically pore-network architecture) and strong sorption capacities (chemical retention from clay minerals) of both shallow and deep mudstones lead to the synergistic retention of cationic radionuclides and their utilities as effective host rocks and barrier materials. Our unique approaches of studying how the micro-scale pore structure affect macro-scale fluid flow, diffusion & retention, and chemical transport produce improved mechanistic understanding, and realistic quantification, of diffusion and retention of typical radionuclides in a range of generic host rocks and barrier materials (clay/shale, salt, crystalline rock, and tuff), with the overall results leading to scientifically-based understanding of enhanced isolation (from both diffusion and retention) of radionuclides and improved confidence on the long-term performance of geological repository to store high-level radioactive wastes. In addition to the training of 25 undergraduates, graduates, and postdocs of UTA, the scientists (organizations) involved in performing this work (e.g., discussion, sample sharing, and operation of SANS and SAXS instruments) include Ed Matteo, Yifeng Wang, and Kristopher Kuhlman (Sandia National Laboratories), Jens Birkholzer, Liange Zheng, Tim Kneafsey, and Sharon Borglin (Lawrence Berkeley National Laboratory), Mavrik Zavarin (Lawrence Livermore National Laboratory), Yukio Tachi and Yuta Fukatsu (Japan Atomic Energy Agency), Mieke de Craen (Euridice, Belgium), Markus Bleuel (NIST), Wei-Ren Chen, Gergely Nagy, Changwoo Do, William Heller, Larry Anovitz, and Kenneth Littrell (ORNL), as well as Jan Illvsky, Ivan Kuzmenko, Ju-Sang Park and Jon Almers (ANL). Key deliverables include a total of 13 peer-reviewed journal articles (nine published and three under review), 23 presentations at scientific conferences (AAPG, AAPG Southwest Section, AGU, Asian Clay Conference, GSA, GSA South-Central Section, IHLRWM, InterPore, International Conference on Chemistry and Migration Behavior of Actinides and Fission Products in the Geosphere, International Conference on Coupled Processes in Fractured Geological Media: Observation, Modeling and Application), and academic institutions (UTA, New Mexico State University; University of Poitiers, France; University of Helsinki, Finland; Uppsala University, Sweden; Istanbul Technical University, Turkey) and other organizations (Andra, France; Posiva Oy, Finland).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact X-band split electron linac for cabinet-size small-sample irradiators

Many small-scale industrial radiation facilities rely on hazardous radioisotope-based gamma ray irradiators, which are being gradually replaced by alternative technologies, such as particle accelerators. RadiaBeam has developed a compact, cabinet-size, 3 MeV electron-linac-based irradiator to match the penetration of Co-60 and provide high irradiation throughput. Here the linac utilizes X-band RF power to reduce size, employs an innovative split-linac approach to lower costs, and features a novel X-ray conversion target geometry that spreads the beam out across the target, providing a low dose uniformity ratio. In this paper, we discuss the accelerator design, fabrication, and test results.

43 PARTICLE ACCELERATORS↗

Some physical properties of Apollo 12 lunar samples

The size distribution of the lunar fines is measured, and small but significant differences are found between the Apollo 11 and 12 samples as well as among the Apollo 12 core samples. The observed differences in grain size distribtuion in the core samples are related to surface transportation processes, and the importance of a sedimentation process versus meteoritic impact gardening of the mare grounds is discussed. The optical and the radio frequency electrical properties are measured and are also found to differ only slightly from Apollo 11 results.

Gold, T.↗

Stoichiometric analysis of compositionally graded combinatorial amorphous thin film oxides using laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is a recently developed locally destructive elemental analysis technique that can be used to analyze solid, liquid, and gaseous samples. In the system explored here, a neodymium-doped yttrium aluminum garnet laser ablates a small amount of the sample and spectral emission from the plume is analyzed using a set of synchronized spectrometers. We explore the use of LIBS to map the stoichiometry of compositionally graded amorphous indium zinc oxide thin-film libraries. After optimization of the experimental parameters (distance between lens and samples, spot size on the samples, etc.), the LIBS system was calibrated against inductively coupled plasma atomic emission spectroscopy which resulted in a very consistent LIBS-based elemental analysis. Various parameters that need to be watched closely in order to produce consistent results are discussed. We also compare LIBS and x-ray fluorescence as techniques for the compositional mapping of libraries.

36 MATERIALS SCIENCE↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial heterogeneity analyses of pore structure and mineral composition of Barnett Shale using X-ray scattering techniques

The spatial heterogeneity of pore structure and mineral composition at mu m to mm scales in mm to cm-sized shale samples complicates the laboratory measurements of porosity & pore size distribution and consequently reservoir quality evaluation. Traditional fluid invasion characterization methods typically take hours to days to get data and can only test relatively small samples (usually 2.54 cm diameter core plugs and mm-sized rock chips). Furthermore, the Xray scattering techniques at the Advanced Photon Source of the Argonne National Laboratory have the capability to non-destructively determine the pore structure and mineral composition of mm x mm area in a short time of seconds and to hold several to hundreds of mm 2 sized sample to conduct large area heterogeneity analysis in the short duration of hours. With the use of ultra-small angle X-ray scattering (USAXS), small-angle X-ray scattering (SAXS), and wide-angle X-ray scattering (WAXS), the porosity, surface area and pore size distribution of two Barnett Shale samples have been mapped out and the mineral compositions are determined qualitatively. Overall, the porosity and pore surface area of the Barnett Shale Sample A over a 36 cm2 area ranges from 1.70 % to 8.13 % and 8.87 m 2 /g to 40.2 m 2 /g respectively. The porosity and surface area of Sample B over a 24 cm 2 area varies from 3.15 % to 11.7 % and 18.3 m 2 /g to 60.2 m 2 /g. In Sample A, the mineral composition shows a shift from carbonate-rich to siliciclastic-rich over a distance of several millimeters. For Sample B, the mineral compositions are mainly siliciclastic and do not show an obvious lithological change. The direct observations of high spatial heterogeneity of pore structure and mineral composition in shale illustrate the utility of integrated X-ray scattering techniques to provide valuable insights into shale studies and reservoir evaluation.

58 GEOSCIENCES↗

Freeze-cast yttria-stabilized zirconia pore networks: Effects of alcohol additives

Freeze casting yttria-stabilized zirconia (YSZ) can be useful in making electrodes for solid oxide fuel cells (SOFCs) by introducing hierarchical porosity to increase triple-phase boundary (TPB) area while maintaining adequate fuel flow. Here, in this work, the influence of alcohol additives on pore structure of aqueous YSZ freeze-cast samples was investigated. Slurries with ethanol, iso-propyl alcohol, or methanol as additives were compared to a control sample. Pore characteristics along sample lengths were measured using X-ray computed tomography reconstructions. The control sample showed significant changes in pore size along sample length, whereas pore size of the alcohol additive samples remained similar, indicating that freezing rates of the additive samples remained constant during solidification. Finally, ice lens formation and interactions between alcohols and slurry functional additives (dispersant, surfactant, and binder) resulted in complex pore structures which show promise in increasing SOFC TPB area.

36 MATERIALS SCIENCE↗

Accurate temperature model for absorptance determination of optical components with laser calorimetry

In the international standard (International Organization for Standardization 11551) for measuring the absorptance of optical components (i.e., laser calorimetry), the absorptance is obtained by fitting the temporal behavior of laser irradiation-induced temperature rise to a homogeneous temperature model in which the infinite thermal conductivity of the sample is assumed. In this paper, an accurate temperature model, in which both the finite thermal conductivity and size of the sample are taken into account, is developed to fit the experimental temperature data for a more precise determination of the absorptance. The difference and repeatability of the results fitted with the two theoretical models for the same experimental data are compared. The optimum detection position when the homogeneous model is employed in the data-fitting procedure is also analyzed with the accurate temperature model. The results show that the optimum detection location optimized for a wide thermal conductivity range of 0.2-50W/m{center_dot}K moves toward the center of the sample as the sample thickness increases and deviates from the center as the radius and irradiation time increase. However, if the detection position is optimized for an individual sample with known sample size and thermal conductivity by applying the accurate temperature model, the influence of the finite thermal conductivity and sample size on the absorptance determination can be fully compensated for by fitting the temperature data recorded at the optimum detection position to the homogeneous temperature model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗