Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

SU-E-J-06: A Feasibility Study On Clinical Implementation of 4D-CBCT in Lung Cancer Treatment

Purpose: Four-dimensional cone-beam CT (4D-CBCT) is a novel imaging technique to setup patients with pulmonary lesions in radiation therapy. This paper is to perform a feasibility study on the implementation of 4D-CBCT as image guidance for (1) SBRT and (2) Low Modulation (Low-Mod) IMRT in lung cancer treatment. Methods: Image artifacts and observers variability are evaluated by analyzing the 4D-CT QA phantom and patient 4D image data. There are two 4D-CBCT image artifacts: (1) Spatial artifact caused by the patient irregular breathing pattern will generate blurring and anatomy gap/overlap; (2) Cone beam scattering and hardening artifact will affect the image spatial and contrast resolution. The couch shift varies between 1mm to 3mm from different observers during the 4D-CBCT registration. Breath training is highly recommended to improve the respiratory regularity during CT simulation and treatment, especially for SBRT. Elekta XVI 4.5 Symmetry protocol is adopted in the patient 4DCBCT scanning and intensity-based registration. Physician adjustments on the auto-registration are involved prior to the treatment. Physician peer review on 4D-CBCT image acquisition and registration is also recommended to reduce the inter-observer variability. The average 4D-CT in reference volume coordinates is exported to MIM Vista 5.6.2 to manually fuse to the planning CT for further evaluation. Results: (1) SBRT: 4DCBCT is performed in dry-run and in each treatment fraction. Image registration and couch shift are reviewed by another physician on the 1st fraction before the treatment starts. (2) Low-Mod IMRT: 4D-CBCT is performed and peer reviewed on weekly basis. Conclusion: 4D-CBCT in SBRT dry-run can discover the ITV discrepancies caused by the low quality 4D-CT simulation. 4D-CBCT during SBRT and Low-Mod IMRT treatment provides physicians more confidence to target lung tumor and capability to evaluate inter-fractional ITV changes. More advanced 4D-CBCT scan protocol and reconstruction algorithm may be needed in the future.

60 APPLIED LIFE SCIENCES↗

Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms

A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of the Uranium-Bearing Products of the Ammonia Injection Remediation Method - 15707

Commissioned in 1943, the Hanford Site is the home of the world's first full-scale nuclear production facility. After more than 40 years of processing, improper discharge and failed storage tanks have resulted in the contamination of the Hanford vadose zone with radiologically contaminated waste. Remediation methods considered for the area include sequestration of the mobile uranium by injection of ammonia (NH{sub 3}) gas. Injection of this reactive gas increases the pore water pH, promoting the dissolution of soil minerals; a subsequent re-establishment of natural conditions is believed to result in the recrystallization of those soil minerals and the co-precipitation of uranium phases. Characterization of the precipitates formed when the ammonia (NH{sub 3}) injection method, proposed for the Hanford vadose zone, is applied to synthetic pore water on a laboratory scale. This involves: Identification of the uranium-bearing phases; A study of the effect of pore water constitution on the phases produced. Synthetic pore water solutions were prepared to mimic selected constituents of the pore water from the Hanford 200 Area: Varying constituent concentrations; Observations led to modifications to increase relative uranium content: 200 ppm → 500 ppm U; Substituted sodium silicate for silicic acid. Dried samples were analyzed by SEM-EDS and powder X-ray diffraction (XRD). A suspension in ethanol was prepared and analyzed by Transmission Electron Microscope (TEM) with Selective Area Electron Diffraction (SAED). Studied and applied geochemical modeling software (Visual Minteq and Geo-chemist's Workbench) for speciation and prediction of potential species formed. Discussion/Conclusions: - SEM-EDS Analysis: Scanning electron microscopy revealed areas of high average atomic weight which would be confirmed to be uranium-rich by energy dispersive spectroscopy analysis. The samples prepared with a more than two-fold increase in uranium concentration did not show the crystal-like forms spotted in the lower [U] samples. The samples prepared with silicic acid substituted in showed little to no uranium precipitation [not shown]. - Diffraction Analysis: Powder XRD analysis of the low [U] samples confirmed the presence of repeating crystalline patterns in the precipitate samples. Nitratine (NaNO{sub 3}) showed a massive presence, potentially obscuring significant peaks in the low [U] samples. Though it was not predicted, there was a tentative match for cejkaite (Na{sub 4}(UO{sub 2})(CO{sub 3}){sub 3}). Elevated uranium samples showed none of the needle-like crystalline shapes [diffraction data pending]. TEM - SAED confirmed the presence of a polycrystalline phase. Data analysis is complex but a comparison of average d-spacings with those of reference minerals could further support a match with cejkaite. - Geochemical Modeling: The system conditions were input into geochemical modeling software to predict the forms present throughout the reaction process. The model was used to demonstrate that the pH of the system could be increased using [NH{sub 4}{sup +}] in solution to better represent the system. Using the [NH{sub 4}{sup +}] increase, the changes in significant species with increasing pH were observed. Future Work: Repeat samples will be prepared and analyzed to bolster any potential identification. Promising samples will be submitted to the PNNL's EMSL facility, which is better equipped to perform the required analyses. An expanded study on the impact of carbonate (CO{sub 3}{sup 2-}) on the phases produced.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data mining graphene: Correlative analysis of structure and electronic degrees of freedom in graphenic monolayers with defects

The link between changes in the material crystal structure and its mechanical, electronic, magnetic, and optical functionalities known as the structure-property relationship is the cornerstone of the contemporary materials science research. The recent advances in scanning transmission electron and scanning probe microscopies (STEM and SPM) have opened an unprecedented path towards examining the materials structure property relationships on the single-impurity and atomic-configuration levels. Lacking, however, are the statistics-based approaches for cross-correlation of structure and property variables obtained in different information channels of the STEM and SPM experiments. Here we have designed an approach based on a combination of sliding window Fast Fourier Transform, Pearson correlation matrix, linear and kernel canonical correlation, to study a relationship between lattice distortions and electron scattering from the SPM data on graphene with defects. Our analysis revealed that the strength of coupling to strain is altered between different scattering channels which can explain coexistence of several quasiparticle interference patterns in the nanoscale regions of interest. In addition, the application of the kernel functions allowed us extracting a non-linear component of the relationship between the lattice strain and scattering intensity in graphene. Lastly, the outlined approach can be further utilized to analyzing correlations in various multi-modal imaging techniques where the information of interest is spatially distributed and has usually a complex multidimensional nature.

36 MATERIALS SCIENCE↗

Formation and Morphology of "shish-like" Fibril Crystals of Aliphatic Polyesters from the Sheared Melt

We found the formation of 'shish-like' fibril crystals of aliphatic polyesters such as poly(L-lactic acid) (PLLA), poly({var_epsilon}-caprolactone) (PCL), poly(12-hydroxydodecanoic acid) (PHDA) and poly(16-hydroxyhexadecanoic acid) (PHHA) from the sheared melt with shear rate {gamma} = 5 s{sup -1} observed by polarizing optical microscope (POM). The melting temperature T{sub m}s of obtained fibril crystals of PLLA and PCL were higher than those of spherulites and were close to the equilibrium melting temperature T{sub m}{sup 0}. The small angle X-ray scattering (SAXS) patterns from the bulk sample including fibril crystals, small amount of unoriented small crystals and amorphous showed no peaks arose from the existence of long periods in fibril crystals. These are the evidence that the observed fibril crystals consist of assemblies of a lot of extended chain crystals (ECCs). We observed the morphology of moderately extracted single strand of fibril crystals at the magnification of POM by means of scanning electron microscope. We found that macroscopic fibril crystals of PLLA with diameter d = 10 {micro}m consist of the bundle structure of microscopic fibril crystals with d = 2 {micro}m. From POM observation of the formation of fibril crystals of PLLA and PCL, we showed phase diagrams of molecular weight M and crystallization temperature T{sub c} for the formation of fibril crystals. From these phase diagrams, we evaluated a critical M and T{sub c} for the formation of fibril crystals. Moreover, from the sequential melting and crystallization experiments, it was implied that the entanglement and transesterification play an important role on the formation of fibril crystals of aliphatic polyesters.

36 MATERIALS SCIENCE↗

Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer

Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polymorphic, Porous, and Host–Guest Nanostructures Directed by Monolayer–Substrate Interactions: Epitaxial Self-Assembly Study of Cyclic Trinuclear Au(I) Complexes on HOPG at the Solution–Solid Interface

Synthesis, crystallographic characterization, and molecular self-assembly of two novel cyclotrimeric gold(I) complexes, Au 3 [3,5-(COOEt) 2 Pz] 3 (Au 3 Pz 3 ) and Au 3 [(n-Pr–O)C=N(Me)] 3 (Au 3 Cb 3 ) was studied. Single crystal X-ray crystallography data reveal that both gold(I) complexes have one-dimensional stacking patterns caused by intermolecular Au(I)···Au(I) aurophilic interactions. The Au 3 Pz 3 trimer units stack with two alternate and symmetrical Au(I)···Au(I) interactions while the Au 3 Cb 3 units have three alternating and nonsymmetrical Au(I)···Au(I) interactions. Molecular self-assembly of the gold(I) complexes on the 1-phenyloctane/highly ordered pyrolytic graphite (HOPG) (0001) solution–solid interface is studied with scanning tunneling microscopy (STM). The gold(I) cyclotrimers form epitaxial nanostructures on the HOPG surface. At a concentration of ~1 × 10 –4 M, Au 3 Pz 3 complexes exhibit a single morphology, while Au 3 Cb 3 complexes exhibit polymorphology. Two polymorphs, one nonporous and the other porous, are observed at 22.0 ± 2.0 °C for Au 3 Cb 3 complexes. A nonporous, low-surface-density (0.82 molecules/nm 2 ) Au 3 Cb 3 nanostructure forms first and then transforms into a high-density (1.43 molecules/nm2) porous nanostructure. This is the first time any porous surface nanostructure is reported for an organometallic system. The porous structure is thought to be stabilized by a combination of hydrogen bonding and monolayer–substrate interactions. These pores are utilized to incorporate pyrene into the film, rendering this the first organometallic host–guest system imaged at the solid–solution interface. In conclusion, molecular and periodic density functional theory (DFT) calculations shed light on the two-dimensional topography and polymorphic self-assembly revealed by STM; these calculations suggest significant electronic hybridization of the Au 3 trimer orbitals and HOPG. The multiple-technique approach used herein provides insights concerning molecule–substrate and molecule–molecule interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting target vessel location on robot-assisted coronary artery bypass graft using CT to ultrasound registration

Purpose: Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, which is based solely on pre-operative computed tomography (CT) images. In this paper, the authors propose a technique to estimate the global peri-operative displacement of the heart and to predict the intra-operative target vessel location, validated via both an in vitro and a clinical study. Methods: As the peri-operative heart migration during RA-CABG has never been reported in the literatures, a simple in vitro validation study was conducted using a heart phantom. To mimic the clinical workflow, a pre-operative CT as well as peri-operative ultrasound images at three different stages in the procedure (Stage{sub 0}--following intubation; Stage{sub 1}--following lung deflation; and Stage{sub 2}--following thoracic insufflation) were acquired during the experiment. Following image acquisition, a rigid-body registration using iterative closest point algorithm with the robust estimator was employed to map the pre-operative stage to each of the peri-operative ones, to estimate the heart migration and predict the peri-operative target vessel location. Moreover, a clinical validation of this technique was conducted using offline patient data, where a Monte Carlo simulation was used to overcome the limitations arising due to the invisibility of the target vessel in the peri-operative ultrasound images. Results: For the in vitro study, the computed target registration error (TRE) at Stage{sub 0}, Stage{sub 1}, and Stage{sub 2} was 2.1, 3.3, and 2.6 mm, respectively. According to the offline clinical validation study, the maximum TRE at the left anterior descending (LAD) coronary artery was 4.1 mm at Stage{sub 0}, 5.1 mm at Stage{sub 1}, and 3.4 mm at Stage{sub 2}. Conclusions: The authors proposed a method to measure and validate peri-operative shifts of the heart during RA-CABG. In vitro and clinical validation studies were conducted and yielded a TRE in the order of 5 mm for all cases. As the desired clinical accuracy imposed by this procedure is on the order of one intercostal space (10-15 mm), our technique suits the clinical requirements. The authors therefore believe this technique has the potential to improve the pre-operative planning by updating peri-operative migration patterns of the heart and, consequently, will lead to reduced conversion to conventional open thoracic procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Engineered Cracks in Catalyst Layers on PEMFC Catalyst Layer Durability

Proton exchange membrane fuel cells (PEMFCs) are expected to play a pivotal role in decarbonizing the transportation sector, and particularly heavy-duty vehicles (HDVs). However, improvements in durability are needed for PEMFCs to compete with state-of-the-art power sources for HDVs. Here, we examine how catalyst layer (CL) cracks that are engineered affect the CL durability by using patterned silicon templates to control the CL crack density at the micrometer scale. Electrochemical analyses show that the initial PEMFC performance is relatively unaffected by crack density, but the performance after durability testing was strongly affected. Specifically, CLs with high crack density showed higher performance relative to CLs without cracks after application of a carbon corrosion accelerated stress test. Electrochemical analyses coupled with X-ray computed tomography and scanning transmission electron microscopy with energy dispersive X-ray spectroscopy showed that the cracks provide shorter oxygen diffusion pathways to reaction sites, leading to decreased oxygen transport resistance. Additionally, we observed that the catalyst durability is unaffected by cracks. Our results provide a mechanistic explanation of the role of cracks in CL durability.

30 DIRECT ENERGY CONVERSION↗

{sup 18}F-Fluorodeoxyglucose/Positron Emission Tomography Predicts Patterns of Failure After Definitive Chemoradiation Therapy for Locally Advanced Non-Small Cell Lung Cancer

Background: We previously reported that pretreatment positron emission tomography (PET) identifies lesions at high risk for progression after concurrent chemoradiation therapy (CRT) for locally advanced non-small cell lung cancer (NSCLC). Here we validate those findings and generate tumor control probability (TCP) models. Methods: We identified patients treated with definitive, concurrent CRT for locally advanced NSCLC who underwent staging {sup 18}F-fluorodeoxyglucose/PET/computed tomography. Visible hypermetabolic lesions (primary tumors and lymph nodes) were delineated on each patient's pretreatment PET scan. Posttreatment imaging was reviewed to identify locations of disease progression. Competing risks analyses were performed to examine metabolic tumor volume (MTV) and radiation therapy dose as predictors of local disease progression. TCP modeling was performed to describe the likelihood of local disease control as a function of lesion size. Results: Eighty-nine patients with 259 hypermetabolic lesions (83 primary tumors and 176 regional lymph nodes) met the inclusion criteria. Twenty-eight patients were included in our previous report, and the remaining 61 constituted our validation cohort. The median follow-up time was 22.7 months for living patients. In 20 patients, the first site of progression was a primary tumor or lymph node treated with radiation therapy. The median time to progression for those patients was 11.5 months. Data from our validation cohort confirmed that lesion MTV predicts local progression, with a 30-month cumulative incidence rate of 23% for lesions above 25 cc compared with 4% for lesions below 25 cc (P=.008). We found no evidence that radiation therapy dose was associated with local progression risk. TCP modeling yielded predicted 30-month local control rates of 98% for a 1-cc lesion, 94% for a 10-cc lesion, and 74% for a 50-cc lesion. Conclusion: Pretreatment FDG-PET identifies lesions at risk for progression after CRT for locally advanced NSCLC. Strategies to improve local control should be tested on high-risk lesions, and treatment deintensification for low-risk lesions should be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lamellipodial wrinkles in fish keratocytes as markers of imperfect coordination between extension and retraction during cell migration

Highlights: • Migrating fish keratocytes display prominent lamellipodial wrinkles. • A numerical model shows that wrinkles can arise due to compressive stresses. • In the model, wrinkles only arise if the rear of the cell is transiently stuck. • Experimentally pinning the rear of the cell also induces wrinkles. • Wrinkles reflect imbalances between retraction and extension during migration. Cell migration involves the precise coordination between extension at the front of the cell and retraction at the rear. This coordination is particularly evident in fast moving cells such as fish keratocytes, where it leads to highly stable gliding motion, propelled at the front by broad, 0.1-0-2 μm thick lamellipodia. Transient uncoupling between extension and retraction can occur if the rear is temporarily stuck, which might eventually lead to cell shape instabilities. We have frequently observed in fish keratocytes the presence of lamellipodial radial wrinkles, detected by confocal, scanning electron and side-view microscopy as folds in the lamellipodium up to 2 μm in height. Using a linear finite elements analysis, we simulated the displacement of cells either with perfect coordination between extension and retraction or with the rear transiently stuck while the front continues extending, and we observed that in this last condition compression stresses arise in the lamellipodium which predict the formation of the observed pattern of lamellipodial wrinkles. In support of the numerical modeling findings, we observed that the transient halting of retraction at the rear using micromanipulation induced the formation of lamellipodial wrinkles in previously flat lamellipodia. The obtained results suggest that the conspicuous lamellipodial wrinkles observed in migrating fish keratocytes are the product of transient imbalances between front and rear displacements, and are therefore useful markers of the short scale dynamics of extension and retraction coordination during cell migration.

60 APPLIED LIFE SCIENCES↗

Effect of 3D-printed surface textures on wear mechanism in 3-body abrasion of soil

This study systematically investigates the enhancement of wear resistance in 3D printed surface textures through both experimental and theoretical approaches. Three distinct surface morphologies (Smooth Surface, Surface with uniformly distributed Pits, and Surface with uniformly distributed Bumps) were fabricated using High-Impact Polystyrene, where the meso-scale textures were precisely controlled through the 3D printing process. Wear behavior was evaluated using a 3-body wear tester in an abrasive particle environment, analyzing the influence of surface textures under various operating conditions. Systematic wear tests revealed that optimally designed surface textures achieved a remarkable 77 % reduction in wear compared to the worst-performing sample. The wear mechanisms were comprehensively characterized through weight loss measurements, Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS) analyses, elucidating the surface morphology changes and their interaction with wear particles. Notably, the study identified how the geometric characteristics of surface textures influence the movement of wear particles and the distribution of contact stresses. Discrete element method simulations corroborated the experimental findings, providing theoretical validation for the enhanced wear resistance of the optimal structure. The high correlation between simulated wear patterns and experimental results validates the reliability of the proposed design methodology. In conclusion, these results demonstrate that 3D printed surface texturing offers a cost-effective and scalable approach to significantly improve wear resistance in engineering applications, presenting a practical alternative to conventional, high-cost surface engineering methods.

3-body abrasion↗

Physics-informed machine learning analysis for nanoscale grain mapping by synchrotron Laue microdiffraction

Understanding the grain morphology, orientation distribution and crystal structure of nanocrystals is essential for optimizing the mechanical and physical properties of functional materials. Synchrotron X-ray Laue microdiffraction is a powerful technique for characterizing crystal structures and orientation mapping using focused X-rays. However, when the grain sizes are smaller than the beam size, mixed peaks in the Laue pattern from neighboring grains limit the resolution of grain morphology mapping. We propose a physics-informed machine learning (PIML) approach that combines a convolutional neural network feature extractor with a physics-informed filtering algorithm to overcome the spatial resolution limits of X-rays, achieving nanoscale resolution for grain mapping. Our PIML method successfully resolves the grain size, orientation distribution and morphology of Au nanocrystals through synchrotron microdiffraction scans, showing good agreement with electron backscatter diffraction results. This PIML-assisted synchrotron microdiffraction analysis can be generalized to other diffraction-based probes, enabling the characterization of nanosized structures with micrometre-sized probes.

X-ray crystallography↗

Nano-Scale Hydroxyapatite: Synthesis, Two-Dimensional Transport Experiments, and Application for Uranium Remediation

Synthetic nano-scale hydroxyapatite (NHA) was prepared and characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM) methods. The XRD data confirmed that the crystalline structure and chemical composition of NHA correspond to Ca 5 OH(PO 4 ) 3 . The SEM data confirmed the size of NHA to be less than 50 nm. A two-dimensional physical model packed with saturated porous media was used to study the transport characteristics of NHA under constant flow conditions. The data show that the transport patterns of NHA were almost identical to tracer transport patterns. This result indicates that the NHA material can move with water like a tracer, and its movement was neither retarded nor influenced by any physicochemical interactions and/or density effects. We have also tested the reactivity of NHA with 1 mg/L hexavalent uranium (U(VI)) and found that complete removal of U(VI) is possible using 0.5 g/L NHA at pH 5 to 6. Our results demonstrate that NHA has the potential to be injected as a dilute slurry for in situ treatment of U(VI)-contaminated groundwater systems.

Kanel, S. R.↗

A further investigation of the centroid-to-centroid method for stereotactic lung radiotherapy: A phantom study

Purpose: Our previous study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] proposed a deformable-registration-based patient setup strategy called the centroid-to-centroid (CTC) method, which can perform an accurate alignment of internal-target-volume (ITV) centroids between averaged four-dimensional computed tomography and cone-beam computed tomography (CBCT) images. Scenarios with variations between CBCT and simulation CT caused by irregular breathing and/or tumor change were not specifically considered in the patient study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] due to the lack of both a sufficiently large patient data sample and a method of tumor tracking. The aim of this study is to thoroughly investigate and compare the impacts of breathing pattern and tumor change on both the CTC and the translation-only (T-only) gray-value mode strategies by employing a four-dimensional (4D) lung phantom.Methods: A sophisticated anthropomorphic 4D phantom (CIRS Dynamic Thorax Phantom model 008) was employed to simulate all desired respiratory variations. The variation scenarios were classified into four groups: inspiration to expiration ratio (IE ratio) change, tumor trajectory change, tumor position change, tumor size change, and the combination of these changes. For each category the authors designed several scenarios to demonstrate the effects of different levels of breathing variation on both of the T-only and the CTC methods. Each scenario utilized 4DCT and CBCT scans. The ITV centroid alignment discrepancies for CTC and T-only were evaluated. The dose-volume-histograms (DVHs) of ITVs for two extreme cases were analyzed.Results: Except for some extreme cases in the combined group, the accuracy of the CTC registration was about 2 mm for all cases for both the single and the combined scenarios. The performance of the CTC method was insensitive to region-of-registration (ROR) size selections, as suggested by the comparable accuracy between 1 and 2 cm expansions of the ROR selections for the method. The T-only method was suitable for some single scenarios, such as trajectory variation, position variation, and size variation. However, for combined scenarios and/or a large variation in the IE ratio, the T-only method failed to produce reasonable registration results (within 3 mm). The discrepancy was close to, or even greater than, 1 cm. In addition, unlike the CTC method, the T-only method was sensitive to the ROR size selection. The DVH analysis suggested that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.Conclusions: The phantom study demonstrated that the CTC method was reliable for scenarios in which breathing pattern variation was involved. The T-only gray value method worked for some scenarios, but not for scenarios that involved an IE ratio variation. For scenarios involving position variation, the T-only method worked only with a careful selection of the ROR, whereas the CTC method was independent of ROR size as long as the ITVs were included in the ROR. One indication of the dose consequence analysis was that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for the chiral magnetic effect through beam energy dependence of charge separation using event shape selection

High-energy, heavy-ion collisions can create local domains of chirality-imbalanced quarks, reflecting the topological features of quantum chromodynamics. The chiral magnetic effect (CME) predicts an electric charge separation of quarks in such topological domains along the magnetic field ($\vec{B}$) generated by the passing of two high-Z nuclei. Here, we use a correlation observable Δ⁢𝛾$^{112}$ between charged meson pairs to detect the CME-induced charge separation and a novel event shape selection (ESS) method to mitigate the background effects related to elliptic flow (𝑣 2 ). The ESS method classifies events based on the emission pattern of final-state particles and determines Δ⁢𝛾$^{112}_{ESS}$ from the zero-flow limit. We reconstruct the $\vec{B}$ field direction from the spectator nucleons, which minimizes backgrounds unrelated to the collective motion of the system. In this work, we report the measurements of Δ⁢𝛾$^{112}$ and a background indicator Δ⁢𝛾$^{132}$ in Au+Au collisions from the Brookhaven National Laboratory Relativistic Heavy Ion Collider (RHIC) Beam Energy Scan phase II and at the top RHIC energy. After background suppression, Δ⁢𝛾$^{132}_{ESS}$ aligns with zero, and Δ⁢𝛾$^{112}_{ESS}$ is reduced to no more than 20% of Δ⁢𝛾$^{112}$. We observe a finite residual charge separation with 2.5⁢𝜎, 3⁢𝜎, and 3.2⁢𝜎 significance in the 20–50% centrality range of Au + Au collisions at 11.5, 14.6, and 19.6 GeV. The results at 17.3 and 27 GeV also show positive values but with a lower significance of 1.3⁢𝜎 and 1.1⁢𝜎, respectively. The corresponding Δ⁢𝛾$^{112}_{ESS}$ values at 7.7, 9.2, and 200 GeV are consistent with zero within uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-QI-19: Evaluation of a Clinical 1.5T MRI for Prostate Cancer MRS Imaging Using a In Vivo Tumor Model

Purpose: Magnetic resonance spectroscopic (MRS) imaging may provide important bio-markers to distinguish normal/cancerous prostate tissue. While MRS imaging requires a high uniform magnetic field, the ability of a clinical 1.5T MRI to achieve a comparable MRS signal is of interest for radiation treatment planning/assessment. This study is to evaluate the MRS imaging of a 1.5T clinical MRI for prostate cancers by comparing with a small animal 7T MRS scanner. Methods: A tumor model was developed by implanting LNCaP tumor cells in nude mice prostates. Tumor was monitored 3 weeks after implantation using MRI, and MRS imaging was performed on the tumor area when the tumor reached around 1cm in diameter. The 1.5T GE clinical MR scanner and the 7T Bruker small animal MR scanner were used for each mouse. MR spectrums acquired with these scanners were analyzed and compared. The signals of Choline and Citrate were considered. Results: The prostate tumor MR spectrum under the 1.5T clinical MRI showed a similar spectrum pattern to that acquired using the 7T animal MRI. The Choline signal (3.2ppm) is clear and there is no clear peak for Citrate (2.6ppm). However, the signal magnitude for Choline is not dominant compared to the background signal under 1.5T MRI. Typical cancerous prostate tissue MR spectrum with an increased Choline signal and a reduced Citrate signal was observed. In addition, signal variation is noticeable between repeated spectrum scans. The average of these scans showed a comparable and consistent spectrum to those under 7T MRI. Conclusion: The clinical 1.5T MRI is able to acquire a MR spectrum for prostate cancer comparable to those acquired using a dedicated 7T MRS scanner. However, to achieve a consistent and reliable spectrum, multiple repeated scans were necessary to get a statistical result and reduce the noise-induced artifact. This work was supported in part by the National Cancer Institute Grant R21 CA131979 and R01CA172638.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-T-02: Can Pre-Treatment 4DCT-Based Motion Margins Estimates Be Trusted for Proton Radiotherapy?

Purpose: Radiotherapy motion margins are generated using pre-treatment 4DCT data. The purpose of this study is to assess if pre-treatment 4DCT is sufficient in proton therapy to provide accurate estimate of motion margins. A dosimetric assessment is performed comparing pre-treatment margins with daily-customized margins. Methods: Gold fiducial markers implanted in lung tumors of patients were used to track the tumor. A spherical tumor of diameter 20 mm is inserted into a realistic digital respiratory phantom, where the tumor motion is based on real patient lung tumor trajectories recorded over multiple days. Using “Day 1” patient data, 100 ITVs were generated with 1 s interval between consecutive scan start times. Each ITV was made up by the union of 10 tumor positions obtained from 6 s scan time. Two ITV volumes were chosen for treatment planning: ITVmean-σ and ITVmean+σ. The delivered dose was computed on i) 10 phases forming the planning ITV (“10-phase” - simulating dose calculation based on 4DCT) and ii) 50 phantoms produced from 100 s of data from any other day with tumor positions sampled every 2 s (“dynamic” - simulating the dose that would actually be delivered). Results: For similar breathing patterns between “Day 1” and any other “Day N(>1)”, the 95% volume coverage (D95) for “dynamic” case was 8.13% lower than the “10-phase” case for ITVmean+σ. For breathing patterns that were very different between “Day 1” and any other “Day N(>1)”, this difference was as high as 24.5% for ITVmean-σ. Conclusion: Proton treatment planning based on pre-treatment 4DCT can lead to under-dosage of the tumor and over-dosage of the surrounding tissues, because of inadequate estimate of the range of motion of the tumor. This is due to the shift of the Bragg peak compared to photon therapy in which the tumor is surrounded by an electron bath.

60 APPLIED LIFE SCIENCES↗