Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

An Overview Of Activation Analysis Techniques And Applications

Activation analysis can be performed using three different techniques, namely: activation with neutrons, with high-energy photons, and with charged particles. The different features as well as the advantages and drawbacks of these separate techniques will be discussed in this paper. During exposure radionuclides are produced in the activated sample and, the turn, the radiation emitted during radioactive decay (photons in the most cases) is measured with appropriate spectrometers. By evaluating the produced spectra, the elemental components of the activated material can be quantitatively ascertained. Through means of activation analysis, basically any kind of material can be studied. And frequently the sample can be analysed as is(instrumentally without complicated radiochemical separation steps), and in favourable cases, the analysis may be conducted non-destructively, i.e. without removing pieces of the interrogated sample. Several common applications will be discussed in this paper.

07 ISOTOPE AND RADIATION SOURCES↗

Compact Permanent Magnet Microwave-Driven Neutron Generator

Permanent magnet microwave-driven neutron generators have been developed at Lawrence Berkeley National Laboratory. The 2.45 GHz microwave signal is directly coupled into the plasma chamber via a microwave window. Plasma is confined in an axial magnetic field produced by the permanent magnets surrounding the plasma chamber. The source chamber is made of aluminum with a diameter of 4 cm and length of 5 cm. A stack of five alumina discs, which are 3 cm in diameter and total length of 3 cm, works as microwave window. Three permanent ring magnets are used to generate the axial magnetic field required for the microwave ion source. Both hydrogen and deuterium plasma have been successfully ignited. With 330W of microwave power, source chamber pressure of 5 mTorr, and an extraction aperture of 2 mm in diameter, the deuterium ion beam measured on the target was approximately 2.5 mA. Over 90% of the ions are atomic. With the ion source at ground potential and titanium target at -40 kV, the analysis of the activated gold foil and calibrated neutron dose monitor both indicated that roughly 10{sup 7} n/s of D-D neutrons have been produced. The D-D neutron yield can be easily scaled up to 10{sup 8} n/s when the titanium target is biased at -100 kV.

43 PARTICLE ACCELERATORS↗

Ion Beam Collimation For Improved Resolution In Associated Particle Imaging

Beam spot size on target for a Penning ion source has been measured under different source operating pressures as a function of the extraction channel length and beam energy. A beam halo/core structure was observed for ion extraction at low extraction voltages, and was greatly reduced at higher beam energy. Collimation through use of longer extraction channels results in reduced ion current on target; the resultant reduction in neutron yield for an API system driven by such an ion source can be compensated for by use of even higher beam energies.

43 PARTICLE ACCELERATORS↗

Radioactive Ion Beam Production Capabilities At The Holifield Radioactive Ion Beam Facility

The Holifield Radioactive Ion Beam Facility (HRIBF) is a national user facility for research with radioactive ion beams (RIBs) that has been in routine operation since 1996. It is located at Oak Ridge National Laboratory (ORNL) and operated by the ORNL Physics Division. The principal mission of the HRIBF is the production of high quality beams of shortlived radioactive isotopes to support research in nuclear structure physics and nuclear astrophysics. HRIBF is currently unique worldwide in its ability to provide neutron-rich fission fragment beams post-accelerated to energies above the Coulomb barrier for nuclear reactions. HRIBF produces RIBs by the isotope separator on-line (ISOL) technique using a particle accelerator system that consists of the Oak Ridge Isochronous Cyclotron (ORIC) driver accelerator, one of the two Injectors for Radioactive Ion Species (IRIS1 or IRIS2) production systems, and the 25-MV tandem electrostatic accelerator that is used for RIB post-acceleration. ORIC provides a light ion beam (proton, deuteron, or alpha) which is directed onto a thick target mounted in a target-ion source (TIS) assembly located on IRIS1 or IRIS2. Radioactive atoms that diffuse from the target material are ionized, accelerated, mass selected, and transported to the tandem accelerator where they are further accelerated to energies suitable for nuclear physics research. RIBs are transported through a beam line system to various experimental end stations including the Recoil Mass Spectrometer (RMS) for nuclear structure research, and the Daresbury Recoil Separator (DRS) for nuclear astrophysics research. HRIBF also includes two off-line ion source test facilities, one low-power on-line ISOL test facility (OLTF), and one high-power on-line ISOL test facility (HPTL). This paper provides an overview and status update of HRIBF, describes the recently completed $4.7M IRIS2 addition and incorporation of laser systems for beam production and purification, and discusses a proposed replacement of the ORIC driver accelerator.

43 PARTICLE ACCELERATORS↗

Combined electron beam imaging and ab initio modeling of T{sub 1} precipitates in Al-Li-Cu alloys

Among the many considerable challenges faced in developing a rational basis for advanced alloy design, establishing accurate atomistic models is one of the most fundamental. Here we demonstrate how advanced imaging techniques in a double-aberration-corrected transmission electron microscope, combined with ab initio modeling, have been used to determine the atomic structure of embedded 1 nm thick T{sub 1} precipitates in precipitation-hardened Al-Li-Cu aerospace alloys. The results provide an accurate determination of the controversial T{sub 1} structure, and demonstrate how next-generation techniques permit the characterization of embedded nanostructures in alloys and other nanostructured materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrasound nondestructive characterization of transparent spinel

Ceramic materials have attractive attributes for applications that experience high stresses or strain rates. Compared to metal-based systems, ceramics offer a lower areal density which reduces weight, but do not depreciate the integrity of other properties. The ability to tailor the microstructure of ceramics used in armor systems is a common way to increase specific mechanical properties or obtain certain material characteristics. Properties such as elastic modulus, hardness, and density are those that are typically desired to be enhanced. By modifying the microstructure one can obtain a ceramic with these enhanced properties as well as high optical transmission across a wide range of the electromagnetic spectrum. The testing of these properties and ballistic performance is usually destructive, expensive, and time consuming. Common assessments using ultrasonic NDE usually include spatially locating large flaws, sonic velocity measurements, and elastic property measurements. The use of acoustic spectroscopy to go beyond typical ultrasonic NDE in structural ceramics and allow for the use of a microstructural characterization tool is investigated in this paper. Ultrasound absorption by lithium fluoride precipitates in aluminate spinel (MgAl{sub 2}O{sub 4}) present as defined spectral peaks. Average heterogeneity size determination in magnesium aluminate spinel MgAl{sub 2}O{sub 4} by method of acoustic spectroscopy is shown.

36 MATERIALS SCIENCE↗

YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) high temperature vibration sensor

A shear-mode piezoelectric accelerometer using YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) single crystal was designed, fabricated and successfully tested for high temperature vibration sensing applications. The prototyped sensor was tested at temperatures ranging from room temperature to 1000 deg. C and at frequencies ranging from 80 Hz to 1 kHz. The sensitivity of the sensor was found to be 5.7 pC/g throughout the tested frequency and temperature range. In addition, YCOB piezoelectric accelerometers remained the same sensitivity at 1000 deg. C for a dwell time of four hours, exhibiting high stability and reliability.

36 MATERIALS SCIENCE↗

Synthesis of higher diamondoids by pulsed laser ablation plasmas in supercritical CO{sub 2}

Pulsed laser ablation (wavelength 532 nm; fluence 18 J/cm{sup 2}; pulse width 7 ns; repetition rate 10 Hz) of highly oriented pyrolytic graphite was conducted in adamantane-dissolved supercritical CO{sub 2} with and without cyclohexane as a cosolvent. Micro-Raman spectroscopy of the products revealed the presence of hydrocarbons possessing sp{sup 3}-hybridized carbons similar to diamond structures. The synthesis of diamantane and other possible diamondoids consisting of up to 12 cages was confirmed by gas chromatography-mass spectrometry. Furthermore, gas chromatography-mass spectrometry measurements of samples before and after pyrolysis treatment indicate the synthesis of the most compact decamantane, namely, superadamantane. It is thought that oxidant species originating from CO{sub 2} during pulsed laser ablation might lead to the selective dissociation of C-H bonds, enabling the synthesis of low H/C ratio molecules. Therefore, laser ablation in supercritical CO{sub 2} is proposed as a practical method for synthesizing diamondoids.

36 MATERIALS SCIENCE↗

Ethanol Sensitivity of Cu{sub 1-x}Sn{sub x}O(x = 0.00, 0.03, and 0.05) Nanoflakes

Cu{sub 1-x}Sn{sub x}O(x = 0.00, 0.03, and 0.05) nanoflakes were synthesized by a simple wet chemical method and X-Ray diffraction (XRD) result confirms the monoclinic structure of CuO with no secondary phases due to Sn doping. The scanning electron microscopic images indicate the formation of nanoflakes. The fundamental Raman modes were observed at 273, 318, 610, and 1084 cm{sup -1} for undoped CuO sample and theses modes were slightly shifted towards lower frequency side for Sn-doped samples, which indicates the inclusion of Sn in CuO. In addition, XRD and Raman studies infer the decrease of crystallinity in doped samples, which is reflected in the sensitivity towards ethanol. The ethanol sensitivity (resistivity measurement) increases with ethanol gas concentration and decreases with Sn-doping in CuO nanoflakes.

36 MATERIALS SCIENCE↗

Thermoluminescence Characteristics of Nanocrystalline LiF Phosphors Synthesized at Different pH Values

Nanocrystalline lithium fluoride (LiF) phosphors have been prepared by the chemical co-precipitation method at different pH values (7.0, 8.0, 9.0). The formation of nanocrystalline structure has been confirmed by X-ray diffraction and transmission electron microscope. The thermolumniscence (TL) properties of LiF phosphors irradiated with gamma rays at different doses have been studied. The analysis of TL glow curve has revealed the existence of two well resolved glow peaks, one low temperature peak at around 145 deg. C and other one at higher temperature around 375 deg. C. The LiF nano-crystallites synthesized at 8.00 pH have been found to show maximum TL intensity at studied gamma doses (0.1 Gy-15 Gy).

36 MATERIALS SCIENCE↗

Nanocrystalline BaSO{sub 4}:Eu For Dosimetry of Proton Beams

Nanocrystalline BaSO{sub 4} doped with Eu, was prepared by the Chemical Co-precipitation method. The particle size was calculated by the broadening of the XRD peaks using Scherrer's formula with particle size around 45 nm. Samples in the form of pellets were irradiated by 150 MeV proton beam with dose range of 0.1 Gy to 325 Gy. Thermoluminescence (TL) glow curves of the irradiated samples were recorded and studied. It has been found that there are two prominent TL glow peaks at 460 K and 495 K. The TL response is sublinear below 1 Gy, linear in the range 1 Gy to 200 Gy and then becomes supralinear for higher doses. The wider linear TL response of nanocrystalline BaSO{sub 4}:Eu and low fading makes it a superior candidate as a dosimeter to be used for detecting the doses of protons for its various applications in the field of space, therapy and research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Positron Annihilation Studies in Search of Fine Precipitates in Fe-9Cr alloys

Positron annihilation lifetime studies were carried out on cold worked pure Fe and Fe-9Cr alloy subjected to isochronal annealing in the temperature range from 300 to 1323 K. The measured lifetimes of Fe-9Cr alloy showed three distinct annealing stages as compared to pure Fe viz., initial annealing of defects, a plateau between 623 K and 873 K and noticeable increase beyond 1123 K. The second annealing stage is likely due to the formation of chromium rich nanoclusters. Third annealing stage beyond 1123 K is attributed to highly defected martensitic phase formation during cooling from y-phase.

36 MATERIALS SCIENCE↗

Cadmium mass measurements between the neutron shell closures at N = 50 and 82

The mass values of the neutron-deficient cadmium isotopes {sup 99-109}Cd and of the neutron-rich isotopes {sup 114,120,122-124,126,128}Cd have been measured using ISOLTRAP. The behavior of the separation energies of the cadmium isotopes from N = 50 to 82 is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of historical metal objects using Laser Induced Breakdown Spectroscopy (LIBS) technique

Analysis of metal objects is a necessary step for establishing an appropriate conservation treatment of an object or to follow up the application's result of the suggested treatments. The main considerations on selecting a method that can be used in investigation and analysis of metal objects are based on the diagnostic power, representative sampling, reproducibility, destructive nature/invasiveness of analysis and accessibility to the appropriate instrument. This study aims at evaluating the usefulness of the use of Laser Induced Breakdown Spectroscopy (LIBS) Technique for analysis of historical metal objects. In this study various historical metal objects collected from different museums and excavations in Egypt were investigated using (LIBS) technique. For evaluating usefulness of the suggested analytical protocol of this technique, the same investigated metal objects were investigated by other methods such as Scanning Electron Microscope with energy-dispersive x-ray analyzer (SEM-EDX) and X-ray Diffraction (XRD). This study confirms that Laser Induced Breakdown Spectroscopy (LIBS) Technique is considered very useful technique that can be used safely for investigating historical metal objects. LIBS analysis can quickly provide information on the qualitative and semi-quantitative elemental content of different metal objects and their characterization and classification. It is practically non-destructive technique with the critical advantage of being applicable in situ, thereby avoiding sampling and sample preparations. It is can be dependable, satisfactory and effective method for low cost study of archaeological and historical metals. But we have to take into consideration that the corrosion of metal leads to material alteration and possible loss of certain metals in the form of soluble salts. Certain corrosion products are known to leach out of the object and therefore, their low content does not necessarily reflect the composition of the metal at the time of the object manufacture. Another point should be taken into consideration that the heterogeneity of a metal alloy object that often result from poor mixing of the different metal alloy composition.There is a necessity to carry out further research to investigate and determine the most appropriate and effective approaches and methods for conservation of these metal objects.

36 MATERIALS SCIENCE↗

Radiotherapy Dose Fractionation under Parameter Uncertainty

In radiotherapy, radiation is directed to damage a tumor while avoiding surrounding healthy tissue. Tradeoffs ensue because dose cannot be exactly shaped to the tumor. It is particularly important to ensure that sensitive biological structures near the tumor are not damaged more than a certain amount. Biological tissue is known to have a nonlinear response to incident radiation. The linear quadratic dose response model, which requires the specification of two clinically and experimentally observed response coefficients, is commonly used to model this effect. This model yields an optimization problem giving two different types of optimal dose sequences (fractionation schedules). Which fractionation schedule is preferred depends on the response coefficients. These coefficients are uncertainly known and may differ from patient to patient. Because of this not only the expected outcomes but also the uncertainty around these outcomes are important, and it might not be prudent to select the strategy with the best expected outcome.

60 APPLIED LIFE SCIENCES↗

Preliminary Study of Burnup Characteristics for a Simplified Small Pebble Bed Reactor

Simplification of the pebble bed reactor by removing the unloading device from the system was peformed. For this reactor design, a suitable fuel-loading scheme is the Peu a Peu (little by little) fueling scheme. In the Peu a Peu modus, there is no unloading device; as such, the fuels are never discharged and remain at the bottom of the core during reactor operation. This means that the burnup cycle and reactivity is controlled by the addition of fuel. The objectives of the the present study were to find a means of carrying out the exact calculations needed to analyze the Peu a Peu fuel-loading scheme and to optimize the fuel composition, and fuel-loading scheme to achieve better burnup characteristics. The Monte Carlo method is used to perform calculations with high accuracy. Before the calculation of the whole core, the analysis for the infinite geometry was performed. The power generated per mass consumed for each combination of the uranium enrichment and packing fraction was analyzed from the parametric survey. By using the optimal value obtained, a whole-core calculation for the small 20 MWth reactor was performed and the criticality and burnup of this design was analyzed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantum state specific reactant preparation in a molecular beam by rapid adiabatic passage

Highly efficient preparation of molecules in a specific rovibrationally excited state for gas/surface reactivity measurements is achieved in a molecular beam using tunable infrared (IR) radiation from a single mode continuous wave optical parametric oscillator (cw-OPO). We demonstrate that with appropriate focusing of the IR radiation, molecules in the molecular beam crossing the fixed frequency IR field experience a Doppler tuning that can be adjusted to achieve complete population inversion of a two-level system by rapid adiabatic passage (RAP). A room temperature pyroelectric detector is used to monitor the excited fraction in the molecular beam and the population inversion is detected and quantified using IR bleaching by a second IR-OPO. The second OPO is also used for complete population transfer to an overtone or combination vibration via double resonance excitation using two spatially separated RAP processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-dependent delay time in ferromagnet/insulator/ferromagnet heterostructures

We study theoretically spin-dependent group delay and dwell time in ferromagnet/insulator/ferromagnet (FM/I/FM) heterostructure. The results indicate that, when the electrons with different spin orientations tunnel through the FM/I/FM junction, the spin-up process and the spin-down process are separated on the time scales. As the self-interference delay has the spin-dependent features, the variations of spin-dependent dwell-time and spin-dependent group-delay time with the structure parameters appear different features, especially, in low incident energy range. These different features show up as that the group delay times for the spin-up electrons are always longer than those for spin-down electrons when the barrier height or incident energy increase. In contrast, the dwell times for the spin-up electrons are longer (shorter) than those for spin-down electrons when the barrier heights (the incident energy) are under a certain value. When the barrier heights (the incident energy) exceed a certain value, the dwell times for the spin-up electrons turn out to be shorter (longer) than those for spin-down electrons. In addition, the group delay time and the dwell time for spin-up and down electrons also relies on the comparative direction of magnetization in two FM layers and tends to saturation with the thickness of the barrier.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗