Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

On entanglement spreading from holography

A global quench is an interesting setting where we can study thermalization of subsystems in a pure state. We investigate entanglement entropy (EE) growth in global quenches in holographic field theories and relate some of its aspects to quantities characterizing chaos. More specifically we obtain four key results: 1. We prove holographic bounds on the entanglement velocity vE and the butterfly effect speed vB that arises in the study of chaos. 2. We obtain the EE as a function of time for large spherical entangling surfaces analytically. We show that the EE is insensitive to the details of the initial state or quench protocol. 3. In a thermofield double state we determine analytically the two-sided mutual information between two large concentric spheres separated in time. 4. We derive a bound on the rate of growth of EE for arbitrary shapes, and develop an expansion for EE at early times. In a companion paper, these results are put in the broader context of EE growth in chaotic systems: we relate EE growth to the chaotic spreading of operators, derive bounds on EE at a given time, and compare the holographic results to spin chain numerics and toy models. In this paper, we perform holographic calculations that provide the basis of arguments presented in that paper.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cardiac progenitor-derived exosomes protect ischemic myocardium from acute ischemia/reperfusion injury

Highlights: ► Cardiac progenitor-derived (CPC) Exosomes protect H9C2 from apoptosis in vitro. ► CPC-exosomes protect cardiomyoyctes from MI/R induced apoptosis in vivo. ► CPC-exosomes were taken up by H9C2 with high efficiency using PKH26 labeling. ► miR-451, one of GATA4-responsive miRNA cluster, is enriched in CPC-exosomes. -- Abstract: Background: Cardiac progenitors (CPC) mediate cardioprotection via paracrine effects. To date, most of studies focused on secreted paracrine proteins. Here we investigated the CPC-derived-exosomes on protecting myocardium from acute ischemia/reperfusion (MI/R) injury. Methods and results: CPC were isolated from mouse heart using two-step protocol. Exosomes were purified from conditional medium, and confirmed by electron micrograph and Western blot using CD63 as a marker. qRT-PCR shows that CPC-exosomes have high level expression of GATA4-responsive-miR-451. Exosomes were ex vivo labeled with PKH26, We observed exosomes can be uptaken by H9C2 cardiomyoblasts with high efficiency after 12 h incubation. CPC-exosomes protect H9C2 from oxidative stress by inhibiting caspase 3/7 activation invitro. In vivo delivery of CPC-exosomes in an acute mouse myocardial ischemia/reperfusion model inhibited cardiomyocyte apoptosis by about 53% in comparison with PBS control (p < 0.05). Conclusion: Our results suggest, for the first time, the CPC-exosomes can be used as a therapeutic vehicle for cardioprotection, and highlights a new perspective for using non-cell exosomes for cardiac disease.

60 APPLIED LIFE SCIENCES↗

Impact of Gemcitabine Chemotherapy and 3-Dimensional Conformal Radiation Therapy/5-Fluorouracil on Quality of Life of Patients Managed for Pancreatic Cancer

Purpose: To report quality of life (QOL) results for patients receiving chemoradiation therapy for pancreatic cancer. Methods and Materials: Eligible patients (n=41 locally advanced, n=22 postsurgery) entered the B9E-AY-S168 study and received 1 cycle of induction gemcitabine (1000 mg/m{sup 2} weekly Multiplication-Sign 3 with 1-week break) followed by 3-dimensional conformal radiation therapy (RT) (54 Gy locally advanced and 45 Gy postsurgery) and concomitant continuous-infusion 5-fluorouracil (5FU) (200 mg/m{sup 2}/d throughout RT). After 4 weeks, patients received an additional 3 cycles of consolidation gemcitabine chemotherapy. Patients completed the European Organization for Research and Treatment of Cancer QLQ-C30 and QLQ-PAN26 questionnaires at baseline, before RT/5FU, at end of RT/5FU, before consolidation gemcitabine, and at treatment completion. Results: The patterns of change in global QOL scores differed between groups. In the locally advanced group global QOL scores were +13, +8, +3, and +1 compared with baseline before RT/5FU (P=.008), at end of RT/5FU, before consolidation gemcitabine, and at treatment completion, respectively. In the postsurgery group, global QOL scores were -3, +4, +15, and +17 compared with baseline at the same time points, with a significant improvement in global QOL before consolidation gemcitabine (P=.03). No significant declines in global QOL were reported by either cohort. Conclusions: This study demonstrates that global QOL and associated function and symptom profiles for pancreatic chemoradiation therapy differ between locally advanced and postsurgery patients, likely owing to differences in underlying disease status. For both groups, the treatment protocol was well tolerated and did not have a negative impact on patients' global QOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Toxicity After Proton Therapy For Prostate Cancer: An Analysis of Outcomes of Prospective Studies Conducted at the University of Florida Proton Therapy Institute

Purpose: Study goals were to characterize gastrointestinal effects of proton therapy (PT) in a large cohort of patients treated for prostate cancer, identify factors associated with rectal bleeding (RB), and compare RB between patients receiving investigational protocols versus those in outcome-tracking protocols. Methods and Materials: A total of 1285 consecutive patients were treated with PT between August 2006 and May 2010. Potential pre-existing clinical and treatment-related risk factors for rectal toxicity were recorded. Common Terminology Criteria for Adverse Events version 3.0 was used to score toxicity. Results: Transient RB was the predominant grade 2 or higher (GR2+) toxicity after PT, accounting for 95% of gastrointestinal events. GR1 RB occurred in 217 patients (16.9%), GR2 RB in 187 patients (14.5%), and GR3 in 11 (0.9%) patients. There were no GR4 or GR5 events. Univariate analyses showed correlations between GR2+ RB and anticoagulation therapy (P=.008) and rectal and rectal wall dose-volume histogram (DVH) parameters (P<.001). On multivariate analysis, anticoagulation therapy (P=.0034), relative volume of rectum receiving 75 Gy (V75; P=.0102), and relative rectal wall V75 (P=.0017) were significant predictors for G2+ RB. Patients treated with investigational protocols had toxicity rates similar to those receiving outcome-tracking protocols. Conclusions: PT was associated with a low rate of GR2+ gastrointestinal toxicity, predominantly transient RB, which was highly correlated with anticoagulation and rectal DVH parameters. Techniques that limit rectal exposure should be used when possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing cathode–electrolyte interphases in batteries

The cathode-electrolyte interphase plays a pivotal role in determining the usable capacity and cycling stability of electrochemical cells, yet it is overshadowed by its counterpart, the solid-electrolyte interphase. This is primarily due to the prevalence of side reactions, particularly at low potentials on the negative electrode, especially in state-of-the-art Li-ion batteries where the charge cutoff voltage is limited. However, as the quest for high-energy battery technologies intensifies, there is a pressing need to advance the study of cathode-electrolyte interphase properties. Here, we present a comprehensive approach to analyse the cathode-electrolyte interphase in battery systems. We underscore the importance of employing model cathode materials and coin cell protocols to establish baseline performance. Additionally, we delve into the factors behind the inconsistent and occasionally controversial findings related to the cathode-electrolyte interphase. In conclusion, we also address the challenges and opportunities in characterizing and simulating the cathode-electrolyte interphase, offering potential solutions to enhance its relevance to real-world applications.

25 ENERGY STORAGE↗

Chemomechanical behaviors of layered cathode materials in alkali metal ion batteries

Layered cathode materials (LCMs), because of their high energy density and relatively stable performance, represent an important class of cathode materials for alkali metal ion ( e.g. , Li + and Na + ) batteries. Chemomechanical behaviors of LCMs, which affect battery performance dramatically, have drawn extensive attention in recent years. Most chemomechanical processes have some common chemical and structural origins that are at the center of materials chemistry, for example, defects and local bonding environments in the solid state. In this review, we first discuss the chemomechanical breakdown of LCMs by introducing their categories and negative effects on the battery performance. We then systematically analyze factors that govern the initiation and propagation of chemomechanical breakdown and summarize their formation mechanisms. Strategies that can enhance the chemomechanical properties of LCMs or reduce the destructive effects of chemomechanical breakdown are then discussed. Lastly, light is shed on the new state-of-the-art techniques that have been applied to study chemomechanical breakdown. This review virtually includes most aspects of the chemomechanical behaviors of LCMs and provides some insights into the important chemical motifs that determine the chemomechanical properties. Thus, we believe that advanced design protocols of LCMs can be developed to effectively address the chemomechanical breakdown issue of LCMs.

25 ENERGY STORAGE↗

Evaluation of Direct Drive Capsule Fill-Tube Assembly Survivability in Support of the 100 GBar Campaign

Capsule fill-tube target assemblies (CFTAs) for direct-drive have been demonstrated in the past for Laser for Laboratory Energetics (LLE) cryogenic layering studies, evolving and building upon successful deliveries for NIF. The current 100 GigaBar (GBar) campaign requires increased tolerances over prior CFTA work in terms of robustness, cleanliness, reduced fill tube diameter and glue size. To tackle these challenges, GA and LLE are developing a direct drive CFTA that survives all fabrication activities, from assembly, qualification testing and transport to cryogenic layering and target chamber insertion at the OMEGA laser facility. Approximately 55 CFTAs of two main designs have been constructed and tested to date, building off the current LLE cryogenic layering study CFTA design (typically 870 µm diameter x 25 µm thick wall capsule). Variations of glass fill tubes sizes from 30, 20 and 10 µm diameter, which are inserted and glued into the capsule. Testing protocols were developed to enable comparison of different designs against one another and evaluate their robustness at room temperature. The testing protocols include pressure checks, resonant vibration mode sweeps, runout and vibration testing to a power spectral density (PSD) input. In this paper we will compare the different design tradeoffs, measurements and results including glue fillets, sag of the fill tubes under gravity, runout and hysteresis, ringdown response, X-ray imaging of the pipette wall thicknesses, and scanning electron microscope (SEM) images taken of failed fill tubes and glue joints. Assessment of the modal vibration modeling for the designs will be compared against the vibration data. Lastly, a design recommendation is put forth meeting the design constraints, which consists of a polymicro composite tube and 10 µm fill tube, ensuring survivability at cryogenic temperatue, a higher first mode resonance and smaller fuel volume.

100 GBar↗

Spin Squeezing with Itinerant Magnetic Dipoles

Entanglement can improve the measurement precision of quantum sensors beyond the shot noise limit. Neutral atoms, the basis of some of the most precise and accurate optical clocks and interferometers, do not naturally exhibit the all-to-all interactions traditionally used to generate such entangled states. On the other hand, these systems exhibit exceedingly high degrees of experimental control over parameters such as temperature, spatial entropy, and itinerancy. In this work, we investigate spin squeezing in a highly coherent itinerant system of neutral atoms with magnetic dipole-dipole interactions. We achieve 7.1 dB of metrologically useful squeezing using finite-range spin-exchange interactions in an erbium quantum gas microscope, and we demonstrate that introducing atomic motion, realizing a dipolar 𝑡−𝐽 model, protects the spin sector coherence at low fillings, significantly improving the achievable spin squeezing in a 2D dipolar system. This work’s protocol can be implemented with most neutral atoms, opening the door to quantum-enhanced metrology in other itinerant dipolar systems, such as molecules or optical lattice clocks, and serves as a novel method for studying itinerant quantum magnetism with long-range interactions.

Atomic, optical & lattice clocks↗

Constrained Deep Reinforcement Learning for Energy Sustainable Multi-UAV Based Random Access IoT Networks With NOMA

In this paper, we apply the Non-Orthogonal Multiple Access (NOMA) technique to improve the massive channel access of a wireless IoT network where solar-powered Unmanned Aerial Vehicles (UAVs) relay data from IoT devices to remote servers. Specifically, IoT devices contend for accessing the shared wireless channel using an adaptive p-persistent slotted Aloha protocol; and the solar-powered UAVs adopt Successive Interference Cancellation (SIC) to decode multiple received data from IoT devices to improve access efficiency. To enable an energy-sustainable capacity-optimal network, we study the joint problem of dynamic multi-UAV altitude control and multi-cell wireless channel access management of IoT devices as a stochastic control problem with multiple energy constraints. We first formulate this problem as a Constrained Markov Decision Process (CMDP), and propose an online model-free Constrained Deep Reinforcement Learning (CDRL) algorithm based on Lagrangian primal-dual policy optimization to solve the CMDP. Extensive simulations demonstrate that our proposed algorithm learns a cooperative policy in which the altitude of UAVs and channel access probability of IoT devices are dynamically controlled to attain the maximal long-term network capacity while ensuring energy sustainability of UAVs, outperforming baseline schemes. The proposed CDRL agent can be trained on a small network, yet the learned policy can efficiently manage networks with a massive number of IoT devices and varying initial states, which can amortize the cost of training the CDRL agent.

42 ENGINEERING↗

SU-E-T-434: Fixed Margin Or Online Adaptation for Intermediate-Risk Prostate Stereotactic Body Radiation Therapy? A Dosimetric Study

Purpose: To investigate the choice of fixed margin or online adaptation when treating intermediate-risk prostate cancer including seminal vesicles (SV) using stereotactic body radiation therapy (SBRT). Methods: 9 prostate SBRT patients were retrospectively studied. All patients were implanted with fiducial markers in the prostate for daily localization and verification. Each patient had 5 pairs of pre-treatment and post-treatment cone-beam CT (CBCT) per protocol. SVs were contoured on planning CT and all CBCTs by one attending physician. Simultaneous integral boost (SIB) IMRT plans were developed to deliver 25Gy/5fx to the SV while delivering 37Gy/5fx to the prostate. A 3mm isotropic margin was added to the prostate while a 5 mm isotropic margin was used for the SV. The planning CT was registered to daily pre-treatment and post-treatment CBCT based on fiducial markers in the prostate to mimic online prostate localization; and the SV on daily CBCT was transferred to the CT structure set after the prostates were aligned. Daily pre-treatment and post-treatment SV dose coverage and the organ-at-risk (OAR) sparing were evaluated for the SIB regimen. At least 95% of the SV need to receive the prescription dose (5Gy per fraction). Results: For the total of 90 daily SVs analyzed (ten CBCTs for each of nine patients), only 45 daily SVs (50%) were able to meet the coverage that 95% of the SV received 25Gy. The OAR sparing performance was acceptable for most of the dosimetric constraints in low-risk prostate SBRT protocol with only two exceptions in bladder V100 (cc). Conclusion: A fixed 5mm margin for SV is not sufficient to provide consistent daily dose coverage due to SV’s substantial inter- and intra-fractional motion relative to the prostate. This finding calls for innovative strategies in margin design as well as online treatment adaptation. This work is partially supported a master research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation using hybrid PET-MRI imaging techniques.

60 APPLIED LIFE SCIENCES↗

WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation show evidence of a persistent global inflammatory response that can be detected using {sup 18}F-FDG PET imaging. This work was supported through the Translational Breast Cancer Studentship award, funded in part by the Breast Cancer Society of Canada. Additional financial support is provided by the London Regional Cancer Program Catalyst Grant and the Thames Valley Veterinary Services.

60 APPLIED LIFE SCIENCES↗

Positron Emission Tomography in Water Resources and Subsurface Energy Resources Engineering Research

Recent studies have demonstrated that positron emission tomography (PET) is a valuable tool for in-situ characterization of fluid transport in porous and fractured geologic media at the laboratory scale. While PET imaging is routinely used for clinical cancer diagnosis and preclinical medical research—and therefore imaging facilities are available at most research institutes—widespread adoption for applications in water resources and subsurface energy resources engineering have been limited by real and perceived challenges of working with this technique. In this study we discuss and address these challenges, and provide detailed analysis highlighting how positron emission tomography can complement and improve laboratory characterization of different subsurface fluid transport problems. The physics of PET are reviewed to provide a fundamental understanding of the sources of noise, resolution limits, and safety considerations. We then layout the methodology required to perform laboratory experiments imaged with PET, including a new protocol for radioactivity dosing optimization for imaging in geologic materials. Signal-to-noise and sensitivity analysis comparisons between PET and clinical X-ray computed tomography are performed to highlight how PET data can complement more traditional characterization methods, particularly for solute transport problems. Lastly, prior work is critically reviewed and discussed to provide a better understanding of the strengths and weakness of PET and how to best utilize PET-derived data for future studies.

02 PETROLEUM↗

Sonication-based isolation and enrichment of Chlorella protothecoides chloroplasts for illumina genome sequencing

With the increasing world demand for biofuel, a number of oleaginous algal species are being considered as renewable sources of oil. Chlorella protothecoides Krüger synthesizes triacylglycerols (TAGs) as storage compounds that can be converted into renewable fuel utilizing an anabolic pathway that is poorly understood. The paucity of algal chloroplast genome sequences has been an important constraint to chloroplast transformation and for studying gene expression in TAGs pathways. In this study, the intact chloroplasts were released from algal cells using sonication followed by sucrose gradient centrifugation, resulting in a 2.36-fold enrichment of chloroplasts from C. protothecoides, based on qPCR analysis. The C. protothecoides chloroplast genome (cpDNA) was determined using the Illumina HiSeq 2000 sequencing platform and found to be 84,576 Kb in size (8.57 Kb) in size, with a GC content of 30.8 %. This is the first report of an optimized protocol that uses a sonication step, followed by sucrose gradient centrifugation, to release and enrich intact chloroplasts from a microalga (C. prototheocoides) of sufficient quality to permit chloroplast genome sequencing with high coverage, while minimizing nuclear genome contamination. The approach is expected to guide chloroplast isolation from other oleaginous algal species for a variety of uses that benefit from enrichment of chloroplasts, ranging from biochemical analysis to genomics studies.

09 BIOMASS FUELS↗

High-throughput sequencing of the chloroplast and mitochondrion of Chlamydomonas reinhardtii to generate improved de novo assemblies, analyze expression patterns and transcript speciation, and evaluate diversity among laboratory strains and wild isolates

Chlamydomonas reinhardtii is a unicellular chlorophyte alga that is widely studied as a reference organism for understanding photosynthesis, sensory and motile cilia, and for development of an algal-based platform for producing biofuels and bio-products. Its highly repetitive, ~205-kbp circular chloroplast genome and ~15.8-kbp linear mitochondrial genome were sequenced prior to the advent of high-throughput sequencing technologies. Here, high coverage shotgun sequencing was used to assemble both organellar genomes de novo. These new genomes correct dozens of errors in the prior genome sequences and annotations. Gen-ome sequencing coverage indicates that each cell contains on average 83 copies of the chloroplast genome and 130 copies of the mitochondrial genome. Using protocols and analyses optimized for organellar tran-scripts, RNA-Seq was used to quantify their relative abundances across 12 different growth conditions. Forty-six percent of total cellular mRNA is attributable to high expression from a few dozen chloroplast genes. RNA-Seq data were used to guide gene annotation, to demonstrate polycistronic gene expression, and to quantify splicing of psaA and psbA introns. In contrast to a conclusion from a recent study, we found that chloroplast transcripts are not edited. Unexpectedly, cytosine-rich polynucleotide tails were observed at the 3’-end of all mitochondrial transcripts. A comparative genomics analysis of eight laboratory strains and 11 wild isolates of C. reinhardtii identified 2658 variants in the organellargenomes, which is 1/10th as much genetic diversity as is found in the nucleus.

ftsH↗

In vitro dose measurements in a human cadaver with abdomen/pelvis CT scans

Purpose: To present a study of radiation dose measurements with a human cadaver scanned on a clinical CT scanner. Methods: Multiple point dose measurements were obtained with high-accuracy Thimble ionization chambers placed inside the stomach, liver, paravertebral gutter, ascending colon, left kidney, and urinary bladder of a human cadaver (183 cm in height and 67.5 kg in weight) whose abdomen/pelvis region was scanned repeatedly with a multidetector row CT. The flat energy response and precision of the dosimeters were verified, and the slight differences in each dosimeter's response were evaluated and corrected to attain high accuracy. In addition, skin doses were measured for radiosensitive organs outside the scanned region with OSL dosimeters: the right eye, thyroid, both nipples, and the right testicle. Three scan protocols were used, which shared most scan parameters but had different kVp and mA settings: 120-kVp automA, 120-kVp 300 mA, and 100-kVp 300 mA. For each protocol three repeated scans were performed. Results: The tube starting angle (TSA) was found to randomly vary around two major conditions, which caused large fluctuations in the repeated point dose measurements: for the 120-kVp 300 mA protocol this angle changed from approximately 110° to 290°, and caused 8% − 25% difference in the point dose measured at the stomach, liver, colon, and urinary bladder. When the fluctuations of the TSA were small (within 5°), the maximum coefficient of variance was approximately 3.3%. The soft tissue absorbed doses averaged from four locations near the center of the scanned region were 27.2 ± 3.3 and 16.5 ± 2.7 mGy for the 120 and 100-kVp fixed-mA scans, respectively. These values were consistent with the corresponding size specific dose estimates within 4%. The comparison of the per-100-mAs tissue doses from the three protocols revealed that: (1) dose levels at nonsuperficial locations in the TCM scans could not be accurately deduced by simply scaling the fix-mA doses with local mA values; (2) the general power law relationship between dose and kVp varied from location to location, with the power index ranged between 2.7 and 3.5. The averaged dose measurements at both nipples, which were about 0.6 cm outside the prescribed scan region, ranged from 23 to 27 mGy at the left nipple, and varied from 3 to 20 mGy at the right nipple over the three scan protocols. Large fluctuations over repeated scans were also observed, as a combined result of helical scans of large pitch (1.375) and small active areas of the skin dosimeters. In addition, the averaged skin dose fell off drastically with the distance to the nearest boundary of the scanned region. Conclusions: This study revealed the complexity of CT dose fluctuation and variation with a human cadaver.

60 APPLIED LIFE SCIENCES↗

Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner

Purpose: The highest photon fluence rate that a computed tomography (CT) detector must be able to measure is an important parameter. The authors calculate the maximum transmitted fluence rate in a commercial CT scanner as a function of patient size for standard head, chest, and abdomen protocols. Methods: The authors scanned an anthropomorphic phantom (Kyoto Kagaku PBU-60) with the reference CT protocols provided by AAPM on a GE LightSpeed VCT scanner and noted the tube current applied with the tube current modulation (TCM) system. By rescaling this tube current using published measurements on the tube current modulation of a GE scanner [N. Keat, “CT scanner automatic exposure control systems,” MHRA Evaluation Report 05016, ImPACT, London, UK, 2005], the authors could estimate the tube current that these protocols would have resulted in for other patient sizes. An ECG gated chest protocol was also simulated. Using measured dose rate profiles along the bowtie filters, the authors simulated imaging of anonymized patient images with a range of sizes on a GE VCT scanner and calculated the maximum transmitted fluence rate. In addition, the 99th and the 95th percentiles of the transmitted fluence rate distribution behind the patient are calculated and the effect of omitting projection lines passing just below the skin line is investigated. Results: The highest transmitted fluence rates on the detector for the AAPM reference protocols with centered patients are found for head images and for intermediate-sized chest images, both with a maximum of 3.4 ⋅ 10{sup 8} mm{sup −2} s{sup −1}, at 949 mm distance from the source. Miscentering the head by 50 mm downward increases the maximum transmitted fluence rate to 5.7 ⋅ 10{sup 8} mm{sup −2} s{sup −1}. The ECG gated chest protocol gives fluence rates up to 2.3 ⋅ 10{sup 8} − 3.6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} depending on miscentering. Conclusions: The fluence rate on a CT detector reaches 3 ⋅ 10{sup 8} − 6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} in standard imaging protocols, with the highest rates occurring for ECG gated chest and miscentered head scans. These results will be useful to developers of CT detectors, in particular photon counting detectors.

60 APPLIED LIFE SCIENCES↗

Creating Accurate Methane Emission Inventories through Data-Driven Airborne Survey Strategies

Because natural gas emits less carbon than other fossil fuels, it holds promise as a green energy transition fuel. However, the overall carbon footprint of natural gas is significantly elevated by methane emissions that occur during its production and transmission (Cusworth et al. 2022). Methane “super-emitters,” while comprising only about 1% of sites, are responsible for the majority of oil- and gas-sourced methane emissions, making their detection and mitigation critical in reducing the climate impact of natural gas and in meeting national and global sustainability goals (Sherwin et al. 2024). Yet, despite advancements in detection, significant uncertainties remain regarding the size, frequency, and duration distributions of methane emissions (e.g., Frankenberg et al. 2016, Cusworth et al. 2022, Chen, Sherwin et al. 2022, Conrad et al. 2023, Johnson et al. 2023, Sherwin et al. 2024) underscoring the need for comprehensive emissions inventories segmented by basin across the US. Airborne surveys are well-suited for collecting data to build these comprehensive, basin-level inventories because they allow for extensive spatial coverage, and have the spatial resolution, and the sensitivity to pinpoint individual methane sources. As remote sensing technologies enable rapid basin-scale surveys, it is imperative to establish scientifically and statistically robust standards to generate reliable and actionable emissions inventories. Recent work has shown that differences in airborne sampling strategies, detection technologies, and analysis can lead to large differences between survey conclusions if not correctly accounted for (Chen et al. 2024). This elevates the importance of incorporating proper sampling and analysis techniques when designing a methane emissions monitoring campaign to produce accurate results and facilitate cross-study comparisons. In this paper, we describe a survey strategy designed using the latest conclusions from the literature to align results from different aerial surveys. We identify several sampling and analysis principles, including large sample sizes, balanced sampling across oil and gas production, careful survey area definition, and a unified protocol for analysis, to be vital to producing an unbiased estimate of basin-scale emissions. We present results from a Department of Energy-funded project that deployed this survey strategy in two understudied oil and gas- producing regions in the United States: the Haynesville Basin in Texas and Louisiana, and the Woodford Shale in the Anadarko Basin in Oklahoma.

03 NATURAL GAS↗