Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Lithium–Sulfur Batteries: 3D Printed Tools and Assembly Techniques for Repeatable Lab-Scale Coin Cell Manufacturing

The coin cell form factor has become a standard in energy storage research owing to its relatively low cost, low quantity of requisite electroactive material, fast experimental turnover, and capability to generate publishable quality data. Coin cell assembly at the lab-scale requires precise manual alignment of the many internal components of a cell to yield a properly functioning device. Truly repeatable device assembly presents a significant challenge to the acquisition of reliable data. In this report, we present a three-dimensional (3D) printable design for a coin cell alignment device and describe techniques for a generalized workflow to achieve reproducible coin cell assembly of lithium-based batteries. Standardized assembly techniques using readily accessible, purpose-built tools were demonstrated for labscale production of lithium−sulfur (Li−S) coin cells. Li−S batteries fabricated using the alignment device as well as conductive adhesive incorporated workflows afforded coin cells with up to 35% reduction of assembly times, comparable or better functional cell yields, and improved electrochemical device performance with more consistent and up to 150 mAh/g higher average discharge capacities coupled with Coulombic efficiency increases of up to 2.0% over manually aligned cell assembly techniques.

Batteries↗

A Mechanistic Study of a-Amino Acid-N-Carboxy Anhydride Polymerization: Comparing Initiation and Termination Events in High Vacuum and Traditional Polymerization Techniques

High-vacuum polymerization of -amino acid-N-carboxyanhydride (NCAs) affords polymers with controlled molecular weights and narrow polydispersities, however a comprehensive study of the end-group composition of the resulting poly(amino acid)s has not yet been performed. This reveals crucial information, as the end-groups are indicative of both the polymerization mechanism (i.e., initiation event) as well as the termination pathways. To this end, poly(O-benzyl-L-tyrosine) initiated by 1,6-diaminohexane was synthesized and subsequently characterized by MALDI-TOF MS, NALDI -TOF MS and 13C NMR spectroscopy to ascertain the end-group structure. Polymers were prepared by both high vacuum and glove box techniques in DMF/THF. Preparation of poly(O-benzyl-L-tyrosine) by high vacuum techniques yielded a polymer initiated exclusively by the normal amine mechanism, and termination by reaction with DMF was observed. In contrast, polymers prepared in the glove box were initiated by the normal amine and activated monomer mechanisms, and several termination products are evident. To our knowledge, this is the first rigorous and comparative analysis of the end-group structure, and it demonstrates the advantage of high vacuum techniques for polymerization of NCAs for the preparation of well-defined poly(amino acid)s with end-group fidelity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimized fractional cloudiness determination from five ground-based remote sensing techniques

A one-year record of fractional cloudiness at 10 minute intervals was generated for the Cabauw Experimental Site for Atmospheric Research [CESAR] (51°58’N, 4° 55’E) using an integrated assessment of five different observational methods. The five methods are based on active as well as passive systems and use either a hemispheric or column remote sensing technique. The one-year instrumental cloudiness data were compared against a 30 year climatology of Observer data in the vicinity of CESAR [1971- 2000]. In the intermediate 2 - 6 octa range, most instruments, but especially the column methods, report lower frequency of occurrence of cloudiness than the absolute minimum values from the 30 year Observer climatology. At night, the Observer records less clouds in the 1, 2 octa range than during the day, while the instruments registered more clouds. During daytime the Observer also records much more 7 octa cloudiness than the instruments. One column method combining a radar with a lidar outstrips all other techniques in recording cloudiness, even up to height in excess of 9 km. This is mostly due to the high sensitivity of the radar that is used in the technique. A reference algorithm was designed to derive a continuous and optimized record of fractional cloudiness. Output from individual instruments were weighted according to the cloud base height reported at the observation time; the larger the height, the lower the weight. The algorithm was able to provide fractional cloudiness observations every 10 minutes for 98% of the total period of 12 months [15 May 2008 - 14 May 2009].

58 GEOSCIENCES↗

How May the Choice of Downscaling Techniques and Meteorological Reference Observations Affect Future Hydroclimate Projections?

Abstract We present an intercomparison of a suite of high‐resolution downscaled climate projections based on a six‐member General Circulation Model (GCM) ensemble from Coupled Models Intercomparison Project (CMIP6). The CMIP6 GCMs have been downscaled using dynamical and statistical downscaling techniques based on two meteorological reference observations over the conterminous United States. We use the regional climate model, RegCM4, for dynamical downscaling, double bias correction constructed analogs method for statistical downscaling, and Daymet and Livneh datasets as the reference observations for statistical training and bias‐correction. We evaluate the performances of downscaled data in both historical and future periods under the SSP585 scenario. While dynamical downscaling improves the simulation of some performance evaluation indices, it adds an extra bias in others, highlighting the need for statistical correction before its use in impact assessments. Downscaled datasets after bias‐correction compare exceptionally well with observations. However, the choice of downscaling techniques and the underlying reference observations influence the hydroclimate characteristics of downscaled data. For instance, the statistical downscaling generally preserves the GCMs climate change signal but overestimates the frequency of hot extremes. Similarly, simulated future changes are sensitive to the choice of reference observations, particularly for precipitation extremes that exhibit a higher projected increase in the ensembles trained and/or corrected by Daymet than Livneh. Overall, these results demonstrate that multiple factors, including downscaling techniques and reference observations, can substantially influence the outcome of downscaled climate projections and stress the need for a comprehensive understanding of such method‐based uncertainties.

54 ENVIRONMENTAL SCIENCES↗

Comparison of machine learning techniques to optimize the analysis of plutonium surrogate material via a portable LIBS device

The utilization of machine learning techniques has become commonplace in the analysis of optical emission spectra. These methods are often limited to variants of principal components analysis (PCA), partial-least squares (PLS), and artificial neural networks (ANNs). A plethora of other techniques exist and are well established in the world of data science, yet are seldom investigated for their use in spectroscopic problems. In this study, machine learning techniques were used to analyze optical emission spectra of laser-induced plasma from ceria pellets doped with silicon in order to predict silicon content. Additionally, a boosted regression ensemble model was created, and its predictive accuracy was compared to that of traditional PCA, PLS, and ANN regression models. Boosted regression tree ensembles yielded fits with R-squared (R2) values as high as 0.964 and mean-squared errors of prediction (MSEPs) as low as 0.074, providing the most accurate predictive model. Neural networks performed with slightly lower R2 values and higher MSEPs compared to the ensemble methods, thus indicating susceptibility to overfitting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the Accuracy of Techniques for Determining Neutron Compound-nucleus Formation Cross Sections

We consider three methods for determining neutron nonelastic cross sections: direct measurement by transmission of neutrons through a spherical shell; subtraction of the angle-integrated elastic cross section from the total cross section; and a modification of the subtraction technique using Wick's limit that in favorable cases can significantly reduce the errors in the subtraction method. We show new results using the modified subtraction technique for nonelastic cross sections at 21.6 MeV neutron energy over a wide mass range, and discuss criteria that should be satisfied in order for the modified subtraction technique to be reliable.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Twistor inspired techniques in QCD

I present a short review of the new twistor inspired techniques in perturbative QCD, which are the result of Witten's conjecture of a duality between twistors and string theory. I give an introduction to the main two tree-level techniques, the BCFW recursion and the CSW formalism, and show how the idea of using on-shell QCD amplitudes evaluated for complex momenta can lead to efficient techniques to perform analytic computations. Finally, I briefly discuss how these ideas can be applied to loop calculations if they are combined to the generalized unitarity approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The application of neural networks with artificial intelligence technique in the modeling of industrial processes

Neural networks are a relatively new artificial intelligence technique that emulates the behavior of biological neural systems in digital software or hardware. These networks can 'learn', automatically, complex relationships among data. This feature makes the technique very useful in modeling processes for which mathematical modeling is difficult or impossible. The work described here outlines some examples of the application of neural networks with artificial intelligence technique in the modeling of industrial processes.

99 GENERAL AND MISCELLANEOUS↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of synchrotron-based micro-imaging techniques for the analysis of Cultural Heritage materials

The analysis of cultural Heritage objects is often technically challenging. When analyzing micro-fragments, the amount of matter is usually very tiny, hence requiring sensitive techniques. These samples, in particular painting fragments, may present multi-layered structures, with layer thickness of {approx}10 {mu}m. It leads to favor micro-imaging techniques, with a good lateral resolution (about one micrometer), that manage the discriminative study of each layer. Besides, samples are usually very complex in term of chemistry, as they are made of mineral and organic matters, amorphous and crystallized phases, major and minor elements. Accordingly, a multi-modal approach is generally essential to solve the chemical complexity of such hybrid materials. Different examples will be given, to illustrate the various possibilities of synchrotron-based micro-imaging techniques, such as micro X-ray diffraction, micro X-ray fluorescence, micro X-ray absorption spectroscopy and micro FTIR spectroscopy. Focus will be made on paintings, but the whole range of museum objects (going from soft matter like paper or wood to hard matter like metal and glass) will be also considered.

36 MATERIALS SCIENCE↗

Investigation of Strain in AlGaN/GaN Multi Quantum Wells by Complementary Techniques

Al{sub 0.49}Ga{sub 0.51}N(12 nm)/GaN (13 nm) Multi Quantum Wells of 15 periods are grown on sapphire by MOCVD technique. GaN/AlN, each of thickness 200 nm and 20 nm respectively, are used as buffer layers between substrate and epilayer to incorporate the strain in epilayers. It is a well established technique to engineer the band gap in Al{sub x}Ga{sub 1-x}N by adjusting alloy composition. These samples are used in visible and UV light emitters. In the present study, we employ a photoluminescence technique to estimate the composition and luminescence peak positions of AlGaN and GaN. Crystallinity and quality of interfaces have been studied by Rocking curve scan. The Threading Dislocations formed at the GaN buffer layer travel across the entire layers to the surface to form good quality films. Photo-luminescence results show a very sharp GaN peak at 3.4 eV, as observed and reported by others, which shows that samples are free from point defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Schlieren technique applied to the arc temperature measurement in a high energy density cutting torch

Plasma temperature and radial density profiles of the plasma species in a high energy density cutting arc have been obtained by using a quantitative schlieren technique. A Z-type two-mirror schlieren system was used in this research. Due to its great sensibility such technique allows measuring plasma composition and temperature from the arc axis to the surrounding medium by processing the gray-level contrast values of digital schlieren images recorded at the observation plane for a given position of a transverse knife located at the exit focal plane of the system. The technique has provided a good visualization of the plasma flow emerging from the nozzle and its interactions with the surrounding medium and the anode. The obtained temperature values are in good agreement with those values previously obtained by the authors on the same torch using Langmuir probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A technique for extending the precision and the range of temperature programmed desorption toward extremely low coverages

In this paper, an improvement of the temperature programmed desorption (TPD) technique is introduced, which facilitates fully automated sampling of TPD spectra with excellent reproducibility, especially useful for extremely low coverages. By averaging many sampled TPD spectra, the range of the TPD technique can be extended toward lower coverages, as well as the quality of the spectra can be improved. This allows for easy extraction of information about the adsorbate-surface bond. A state of the art TPD apparatus with a two chamber setup and a high quality quadrupole mass spectrometer was extended by automated components. These are an automated gas dosing system, ensuring precise dosing of gas, combined with a motor driven sample manipulation unit and a liquid nitrogen cryostat with automatic refilling. In addition all components were controlled by a computer. A large number of TPD cycles could be sampled without the need of interaction of an operator. Here, it is shown for up to more than 400 TPD cycles. This opens a wide range of new interesting applications for the TPD technique, especially in the limit of zero coverage. Here, basic experiments on well known adsorbate systems are shown to view the ability and limit of this approach.

36 MATERIALS SCIENCE↗

Useful technique for analysis and control of the acceleration beam phase in the azimuthally varying field cyclotron

We have developed a new technique for analysis and control of the acceleration beam phase in the cyclotron. In this technique, the beam current pattern at a fixed radius r is measured by slightly scanning the acceleration frequency in the cyclotron. The acceleration beam phase is obtained by analyzing symmetry of the current pattern. Simple procedure to control the acceleration beam phase by changing coil currents of a few trim coils was established. The beam phase width is also obtained by analyzing gradient of the decreasing part of the current pattern. We verified reliability of this technique with 260 MeV {sup 20}Ne{sup 7+} beams which were accelerated on different tuning condition of the cyclotron. When the acceleration beam phase was around 0 deg., top of the energy gain of cosine wave, and the beam phase width was about 6 deg. in full width at half maximum, a clear turn pattern of the beam was observed with a differential beam probe in the extraction region. Beam phase widths of ion beams at acceleration harmonics of h=1 and h=2 were estimated without beam cutting by phase-defining slits. We also calculated the beam phase widths roughly from the beam current ratio between the injected beam and the accelerated beam in the cyclotron without operating the beam buncher. Both beam phase widths were almost the same for h=1, while phase compressions by a factor of about 3 were confirmed for h=2.

43 PARTICLE ACCELERATORS↗

An imaging technique for detection and absolute calibration of scintillation light

Triggered by the need of a detection system to be used in experiments of nuclear fusion in laser-generated plasmas, we developed an imaging technique for the measurement and calibration of the scintillation light yield of scintillating materials. As in such experiments, all the reaction products are generated in an ultrashort time frame, the event-by-event data acquisition scheme is not feasible. As an alternative to the emulsion technique (or the equivalent CR39 sheets) we propose a scintillating screen readout by means of a high performance charge coupled device camera. Even though it is not strictly required in the particular application, this technique allows the absolute calibration of the scintillation light yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s{sup 2}). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2p radioactivity studied by tracking technique

The recent advance in experimental studies of short-lived exotic nuclei beyond the proton drip line is presented. In particular, in-flight decays of proton-unbound nuclei with picosecond lifetimes can be probed by a novel technique which tracks all decay products precisely, and the decay vertices as well as the angular correlations of the fragments are deduced from the measured trajectories. The corresponding pioneering experiment which identified a previously-unknown isotope {sup 19}Mg and its two-proton (2p) radioactivity as well as studied the reference 2p decay of the known isotope {sup 16}Ne is described. Systematic studies of other 2p precursors beyond the proton drip line are foreseen with this powerful technique whose sensitivity is larger by factor of 30 in comparison with a conventional invariant-mass method. The 2p radioactivity candidates {sup 30}Ar, {sup 34}Ca and {sup 26}S are discussed. Information about the respective one-proton unbound nuclei can be obtained with this technique by evaluating proton-heavy-fragment correlations. Systematic studies of nuclei beyond the proton drip line, e.g., the well-known proton resonances above the 'waiting points' in the astrophysical rp-process, {sup 69}Br and {sup 73}Br are feasible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

43 PARTICLE ACCELERATORS↗