Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Wellbore Fracture Imaging Using Inflow Detection Measurements

One of the most striking measurements taken during DOE’s EGS Collab project at the 4850-foot depth location was the so-called ‘sewer cam’, which enabled direct visualization of the flow of water into the production well through fractures during the stimulation. The ability to see directly which fractures were flowing and (roughly) how much was a breakthrough in understanding the topology of the created fracture network. Achieving this kind of fracture flow imaging at FORGE would be more challenging because of the 225°C temperature, but equally or even more valuable if it could be achieved. In 2017, a joint project between Sandia and Stanford developed a downhole tool concept to measure the enthalpy of multiphase fluid entering a geothermal well from individual fractures (Gao et al., 2017). For the FORGE project, measuring enthalpy is of less interest because the fluid is expected to be single-phase liquid water. However, the foundation of the device was the measurement of chloride ion concentration, which could form the basis for a direct measurement of inflow from fractures. During the 2017 project, this novel chloride sensing system was implemented into a laboratory test instrument, and we confirmed the capability of the system to measure the ion concentration of fluid entering a model wellbore through a small entry port. The wellbore was a 6-inch diameter model well, and the port was approximately 0.08 inch (2mm) in diameter. The device could measure the chloride concentration accurately even when the well was flowing in a bubbly flow. Given its accuracy, the tool should be able to identify locations of water entering the wellbore even if the ion concentration differs only slightly from that of the water in the well. It is likely that different fractures may flow slightly different chloride concentrations, which would make it feasible to detect individual fractures as well as to estimate the volume of their flow. Ultimately, we could also recognize different fractures flowing back significantly different ion concentrations after fracturing in the FORGE wells. This could be realized by adding different ions in the fracturing fluids in different fractures created at different stages of stimulation (and modifying the tool to include different ion specificity). Sandia’s tool was shown during the study to have the capability to withstand the 225°C temperature, and the electrochemical sensing elements were tested in the laboratory to 225°C at 1500 psia for 24 hours. An early implementation of the fully integrated downhole electrochemical tool, including high-temperature electronics, robust housing, and wireline truck interface, had previously been constructed and tested successfully at Sandia; thus, hardware development tasks focused on advancing the technology readiness level (TRL) of this promising technology for FORGE deployment, rather than on developing a new scientific basis for its operation. The data collection electronics in this tool allowed for several other sensors (pressure, temperature, flow spinner) to be implemented in parallel as well. The research was a new collaboration between Stanford and Sandia to modify and refine the tool for FORGE deployment, to make the downhole measurements, and to characterize the evolving fractures.

15 GEOTHERMAL ENERGY↗

Signal amplification in a solid-state sensor through asymmetric many-body echo

Electronic spins of nitrogen–vacancy centres in diamond constitute a promising system for micro- and nanoscale magnetic sensing, because of their operation under ambient conditions, ease of placement in close proximity to sensing targets and biological compatibility. At high densities, the electronic spins interact through dipolar coupling, which typically limits but can also potentially enhance sensing performance. Here we report the experimental demonstration of many-body signal amplification in a solid-state, room-temperature quantum sensor. Our approach uses time-reversed two-axis-twisting interactions, engineered through dynamical control of the quantization axis and Floquet engineering in a two-dimensional ensemble of nitrogen–vacancy centres. We observe that optimal amplification occurs when the backward evolution time equals twice the forward evolution time, in sharp contrast to the conventional Loschmidt echo. These observations can be understood as resulting from an underlying time-reversed mirror symmetry of the microscopic dynamics, providing key insights into signal amplification and opportunities for practical entanglement-enhanced quantum sensing.

quantum information↗

Shot-noise-limited magnetometer with sub-picotesla sensitivity at room temperature

We report a photon shot-noise-limited (SNL) optical magnetometer based on amplitude modulated optical rotation using a room-temperature {sup 85}Rb vapor in a cell with anti-relaxation coating. The instrument achieves a room-temperature sensitivity of 70 fT/√(Hz) at 7.6 μT. Experimental scaling of noise with optical power, in agreement with theoretical predictions, confirms the SNL behaviour from 5 μT to 75 μT. The combination of best-in-class sensitivity and SNL operation makes the system a promising candidate for application of squeezed light to a state-of-the-art atomic sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research Opportunities on the Low Temperature Microgravity Physics Facility (LTMPF) on the International Space Station

The Low Temperature Microgravity Physics Facility (LTMPF) is a state-of-the-art facility for long duration science Investigations whose objectives can only be achieved in microgravity and at low temperature. LTMPF consists of two reusable, cryogenic facilities with self-contained electronics, software and communication capabilities. The Facility will be first launched by Japanese HIIA Rocket in 2003 and retrieved by the Space Shuttle, and will have at least five months cryogen lifetime on the Japanese Experiment Module Exposed Facility (JEM EF) of the International Space Station. A number of high precision sensors of temperature, pressure and capacitance will be available, which can be further tailored to accommodate a wide variety of low temperature experiments. This paper will describe the LTMPF and its goals and design requirements. Currently there are six candidate experiments in the flight definition phase to fly on LTMPF. Future candidate experiments will be selected through the NASA Research Announcement process. Opportunities for utilization and collaboration with international partners will also be discussed. This work is being carried out by the Jet Propulsion Laboratory, California Institute of Technology under contract to the National Aeronautics and Space Administration. The work was funded by NASA Microgravity Research Division.

Liu, Feng-Chuan↗

CERES BiDirectional Scans (BDS) data in HDF (CER_BDS_Terra-FM2_Edition2)

Each BiDirectional Scans (BDS) data product contains twenty-four hours of Level-1b data for each CERES scanner instrument mounted on each spacecraft. The BDS includes samples taken in normal and short Earth scan elevation profiles in both fixed and rotating azimuth scan modes (including space, internal calibration, and solar calibration views). The BDS contains Level-0 raw (unconverted) science and instrument data as well as the geolocated converted science and instrument data. The BDS contains additional data not found in the Level-0 input file, including converted satellite position and velocity data, celestial data, converted digital status data, and parameters used in the radiance count conversion equations. The following CERES BDS data sets are currently available: CER_BDS_TRMM-PFM_Edition1 CER_BDS_Terra-FM1_Edition1 CER_BDS_Terra-FM2_Edition1 CER_BDS_Terra-FM1_Edition2 CER_BDS_Terra-FM2_Edition2 CER_BDS_Aqua-FM3_Edition1 CER_BDS_Aqua-FM4_Edition1 CER_BDS_Aqua-FM3_Edition2 CER_BDS_Aqua-FM4_Edition2 CER_BDS_Aqua-FM3_Edition1-CV CER_BDS_Aqua-FM4_Edition1-CV CER_BDS_Terra-FM1_Edition1-CV CER_BDS_Terra-FM2_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1997-12-27; Stop_Date=2006-01-01] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 day; Temporal_Resolution_Range=Daily - < Weekly].

TOTAL DETECTOR OUTPUT↗

Stable Targets for Spaceborne Microwave Radiometer Calibration

Beginning in the 1970s, continuous observations of the Earth have been made by spaceborne microwave radiometers. Since these instruments have different observational characteristics, care must be taken in combining their data to form consistent long term records of brightness temperatures and derived geophysical quantities. To be useful for climate studies, data from different instruments must be calibrated relative to each other and to reference targets on the ground whose characteristics are stable and can be monitored continuously. Identifying such targets over land is not straightforward due to the heterogeneity and complexity of the land surface and cover. In this work, we provide an analysis of multi-sensor brightness temperature statistics over ocean, tropical forest, and ice sheet locations, spanning the period from 1978 to the present, and indicate the potential of these sites as continuous calibration monitoring targets.

microwave radiometers↗

Development of nanosized lanthanum strontium aluminum manganite as electrodes for potentiometric oxygen sensor

Nanocrystalline La 0.8 Sr 0.2 Al 0.9 Mn 0.1 O 3 (LSAM) was synthesized by a microwave-assisted citrate method, and characterized by electron microscopy and X-ray diffraction. Electrical behavior of LSAM was investigated by impedance spectroscopy and activation energy of conduction was obtained. Joining of sintered bodies of LSAM and yttria-stabilized tetragonal zirconia polycrystals (YTZP), an extensively studied oxygen ion conducting electrolyte, was examined by isostatic hot pressing methods. Characteristics of the joining region were evaluated with microprobe Raman spectroscopy, and products formed at the interface, primarily strontium zirconate, was confirmed by examination of high temperature chemical reaction between LSAM and YTZP powders. Finally, the electrical properties of the LSAM were exploited for development of a high temperature oxygen sensor in which LSAM functioned as the electrode and YTZP as electrolyte.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensor capsule for diagnosis of gastric disorders

Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.

Holen, J. T.↗

View angle effects in the radiometric measurement of plant canopy temperatures

The thermal infrared sensor response from a wheat canopy was extremely non-Lambertian because of spatial variations in energy flow processes; the effective radiant temperature of the sensor varied as much as 13 C with changing view angle. This variation of sensor response was accurately quantified (root-mean-square of deviations between theoretical and measured responses reduced to 1.1 C) as a function of vegetation canopy geometry, vertical temperature distribution of canopy components, and sensor view angle. The results have important implications for optimizing sensor view angles for remote sensing missions.

Kimes, D. S.↗

Enhancing the pH sensitivity by laterally synergic modulation in dual-gate electric-double-layer transistors

The sensitivity of a standard ion-sensitive field-effect transistor is limited to be 59.2 mV/pH (Nernst limit) at room temperature. Here, a concept based on laterally synergic electric-double-layer (EDL) modulation is proposed in order to overcome the Nernst limit. Indium-zinc-oxide EDL transistors with two laterally coupled gates are fabricated, and the synergic modulation behaviors of the two asymmetric gates are investigated. A high sensitivity of ∼168 mV/pH is realized in the dual-gate operation mode. Laterally synergic modulation in oxide-based EDL transistors is interesting for high-performance bio-chemical sensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Eu/Tb-mixed MOF for luminescent high-temperature sensing

Temperature measurements and thermal mapping using luminescent MOF operating in the high-temperature range are of great interest in the micro-electronic diagnosis. In this paper, we report a thermostable Eu/Tb-mixed MOF Eu{sub 0.37}Tb{sub 0.63}-BTC-a exhibiting strong luminescence at elevated temperature, which can serve as a ratiometric luminescent thermometer for high-temperature range. The high-temperature operating range (313–473 K), high relative sensitivity and accurate temperature resolution, make such a Eu/Tb-mixed MOF useful for micro-electronic diagnosis. - Graphical abstract: A thermostable Eu/Tb-mixed MOF Eu{sub 0.37}Tb{sub 0.63}-BTC-a was developed as a ratiometric luminescent thermometers in the high-temperature range of 313–473 K. - Highlights: • A thermostable Eu/Tb-codoped MOF exhibiting strong luminescent at elevated temperature is reported. • The high-temperature operating range of Eu{sub 0.37}Tb{sub 0.63}-BTC-a is 313–473 K. • The mechanism of Eu{sub 0.37}Tb{sub 0.63}-BTC-a used as thermometers are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development Plan for Acoustic Emission and Vibration Sensors

This document discusses the need for high temperature, radiation tolerant sensors for monitoring vibration and acoustic emissions in advanced reactors and irradiation experiments. Testing of several commercial sensors using infrastructure available at Idaho National Laboratory was performed to benchmark currently available sensors as well as the test facilities. Finally, a strategy for developing sensors for more extreme environments is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Going Places No Infrared Temperature Devices Have Gone Before

Exergen's IRt/c is a self-powered sensor that matches a thermocouple within specified temperature ranges and provides a predictable and repeatable signal outside of this specified range. Possessing an extremely fast time constant, the infrared technology allows users to measure product temperature without touching the product. The IRt/c uses a device called a thermopile to measure temperature and generate current. Traditionally, these devices are not available in a size that would be compatible with the Exergen IRt/c, based on NASA s quarterinch specifications. After going through five circuit designs to find a thermopile that would suit the IRt/c design and match the signal needed for output, Exergen maintains that it developed a model that totaled just 20 percent of the volume of the previous smallest detector in the world. Following completion of the project with Glenn, Exergen continued development of the IRt/c for other customers, spinning off a new product line called the micro IRt/c. This latest development has broadened applications for industries that previously could not use infrared thermometers due to size constraints. The first commercial use of the micro IRt/c involved an original equipment manufacturer that makes laminating machinery consisting of heated rollers in very tight spots. Accurate temperature measurement for this application requires close proximity to the heated rollers. With the micro IRt/c s 50-millisecond time constant, the manufacturer is able to gain closer access to the intended temperature targets for exact readings, thereby increasing productivity and staying ahead of competition.In a separate application, the infrared temperature sensor is being utilized for avalanche warnings in Switzerland. The IRt/c is mounted about 5 meters above the ground to measure the snow cover throughout the mountainous regions of the country.

Source record↗

System and method for the direct calorimetric measurement of laser absorptivity of materials

A method and system for calorimetrically measuring the temperature-dependent absorptivity of a homogeneous material dimensioned to be thin and flat with a predetermined uniform thickness and a predetermined porosity. The system includes a material holder adapted to support and thermally isolate the material to be measured, an irradiation source adapted to uniformly irradiate the material with a beam of electromagnetic radiation, and an irradiation source controller adapted to control the irradiation source to uniformly heat the material during a heating period, followed by a cooling period when the material is not irradiated. A thermal sensor measures temperature of the material during the heating and cooling periods, and a computing system first calculates temperature-dependent convective and radiative thermal losses of the material based on the measured temperature of the material during the cooling period when beam intensity is zero, followed by calculation of the temperature-dependent absorptivity of the material based on the temperature-dependent convective and radiative thermal losses determined from the cooling period.

Rubenchik, Alexander↗

Development of Bismuth and Platinum Bi-Metallic Nanoparticles to Enhance Melt Wire Temperature Resolution

Advanced manufacturing (AM) based on direct-write (DW) technologies has emerged as the predominant enabler for the fabrication of active and passive sensors to be deployed in harsh operating environments seen in a nuclear reactor. Recently, Idaho National Laboratory and Boise State University have recently established capabilities to incorporate advanced manufacturing (AM) methods to accelerate, modernize and enhance functionality of nuclear sensors and instrumentation to achieve the goal of enhancing the safety and efficiency of nuclear reactors. A significant thrust of this work includes the development of nuclear relevant feedstock materials compatible with a variety of direct-write processes for the development, fabrication and testing of AM sensors for peak temperature detection and neutron flux monitoring. For this report, bismuth and bismuth/platinum (BiPt) bi-metallic nanoparticles were synthesized using wet chemical approaches to develop bi-metallic feedstock materials to enhance the sensitivity of melt wires for peak temperature detection. Nanoparticle characterization was performed with Transmission Electron Microscopy (TEM) for nanoparticle composition and size, Transmission X-Ray Diffraction Fluorescence (TXRF) for nanoparticle composition, and Differential Scanning Calorimetry to elucidate the melting point of BiPt bi-metallic nanoparticles. Preliminary results indicate bi-metallic BiPt nanoparticles as a viable pathway for fabricating high resolution AM melt wires.

36 MATERIALS SCIENCE↗

Realizations of the ITS-90 below 24.5561 K at NMIJ/AIST

The International Temperature Scale of 1990 (ITS-90) down to its defined minimum temperature of 0.65 K has been realized at the National Metrology Institute of Japan (NMIJ), using a {sup 3}He vapor pressure thermometer (VPT) from 0.65 K to 3.2 K, a {sup 4}He VPT from 2.2 K to 4.2 K, an interpolating constant-volume gas thermometer (ICVGT) from 3 K to 24.5561 K and standard platinum resistance thermometers (SPRTs) above 13.8803 K. The scales realized by these different thermometers in the overlapped temperature ranges differ among each other. These differences, also known as the non-uniqueness of the ITS-90, are estimated and reported in this paper. The difference between the scales of the SPRTs and ICVGT has a maximum of about 0.6 mK at temperatures close to 15 K, though it is about half of the propagation of the calibration uncertainties of the SPRT at the fixed points. The difference between the vapor pressure scales of {sup 4}He and {sup 3}He shows temperature dependence, which is consistent with that reported previously and has a maximum of about 0.2 mK at temperatures close to 3.1 K. The differences between the ICVGT scales with different lowest calibration temperatures are also estimated. The difference between the ICVGT scales with or without corrections for the aerostatic pressure head, the dead-space volume effect and the thermomolecular pressure difference has a maximum of about 0.17 mK.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data Link Summary for Peer Review.

New generations of high-temperature (HT) sensors and electronics are enabling increased measurement speed and accuracy allowing collection of more accurate and relevant data by downhole tools. Unfortunately, this increased capability is often not realized due to the bottleneck in the uplink data transmission rates due to poor signal characteristics of HT wireline. The objective of this project is to enable the high transmission rate of raw data from downhole tools such as acoustic logging tools and seismic measurement devices to minimize the need for downhole signal processing. To achieve this objective, Sandia has undertaken the effort to develop an asymmetric high-temperature (HT), highspeed data link system for downhole tools capable of operating at temperatures of 210°C while taking advantage of existing wireline transmission channels. Current data rates over HT single-conductor wireline are limited to approximately 200 kbps. The goal system will be capable of transmitting data from the tool to the surface (uplink) at rates of > 1Mbps over 5,000 feet of single-conductor wireline as well as automatically adapt the data rate to the longer wirelines by adapting modern telecommunications techniques to operate on high temperature electronics. The data rate from the surface to the tool (downlink) will be significantly smaller but sufficient for command and control functions. While 5,000 feet of cable is the benchmark for this effort, improvements apply to all lengths of cable.

47 OTHER INSTRUMENTATION↗

Observed and Imputed Volumetric Soil Water Content Timeseries for the New Mexico Elevation Gradient

Reliable soil water content (SWC) data are essential for understanding dryland ecosystem dynamics, but high-frequency SWC sensors often fail, creating gaps in critical datasets. To address this, we developed a Bayesian mixture model that imputes missing SWC using both linear interpolation and an ecosystem water balance model (SOILWAT2), tested across six AmeriFlux eddy covariance tower sites in the New Mexico Elevation Gradient, demonstrating its effectiveness in reconstructing SWC patterns while providing insights into the factors driving SWC variability. Daily volumetric soil water content (SWC) data are provided as csv-formatted spreadsheets for the six AmeriFlux sites (US-Seg, US-Ses, US-Wjs, US-Mpi, US-Vcp, and US-Vcs). For each site there is an observed SWC file (site_SWC_gapfill.csv) and a file that contains imputed SWC (imputed_SWC_site.csv). The observed SWC files contain temperature corrected sensor values, tower precipitation data, as well as outputs from SOILWAT2 simulations that were used to impute SWC. The imputed files contain the original observed SWC values and the imputed missing SWC values. When SWC was missing from the original data, the missing value was imputed based on the Bayesian imputation mixture model. The posterior mean of all imputed values is reported as "mean_X". When the observed SWC was NOT missing, mean_X = observed SWC value (original data). The standard deviation, 2.5th percentile and the 97.5th percentile for the imputed values are also reported in the imputed files. There are readme text files for each file type explaining the contents of each column.

54 ENVIRONMENTAL SCIENCES↗