Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak

The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

What Is the Best Way to Contour Lung Tumors on PET Scans? Multiobserver Validation of a Gradient-Based Method Using a NSCLC Digital PET Phantom

Purpose: To evaluate the accuracy and consistency of a gradient-based positron emission tomography (PET) segmentation method, GRADIENT, compared with manual (MANUAL) and constant threshold (THRESHOLD) methods. Methods and Materials: Contouring accuracy was evaluated with sphere phantoms and clinically realistic Monte Carlo PET phantoms of the thorax. The sphere phantoms were 10-37 mm in diameter and were acquired at five institutions emulating clinical conditions. One institution also acquired a sphere phantom with multiple source-to-background ratios of 2:1, 5:1, 10:1, 20:1, and 70:1. One observer segmented (contoured) each sphere with GRADIENT and THRESHOLD from 25% to 50% at 5% increments. Subsequently, seven physicians segmented 31 lesions (7-264 mL) from 25 digital thorax phantoms using GRADIENT, THRESHOLD, and MANUAL. Results: For spheres <20 mm in diameter, GRADIENT was the most accurate with a mean absolute % error in diameter of 8.15% (10.2% SD) compared with 49.2% (51.1% SD) for 45% THRESHOLD (p < 0.005). For larger spheres, the methods were statistically equivalent. For varying source-to-background ratios, GRADIENT was the most accurate for spheres >20 mm (p < 0.065) and <20 mm (p < 0.015). For digital thorax phantoms, GRADIENT was the most accurate (p < 0.01), with a mean absolute % error in volume of 10.99% (11.9% SD), followed by 25% THRESHOLD at 17.5% (29.4% SD), and MANUAL at 19.5% (17.2% SD). GRADIENT had the least systematic bias, with a mean % error in volume of -0.05% (16.2% SD) compared with 25% THRESHOLD at -2.1% (34.2% SD) and MANUAL at -16.3% (20.2% SD; p value <0.01). Interobserver variability was reduced using GRADIENT compared with both 25% THRESHOLD and MANUAL (p value <0.01, Levene's test). Conclusion: GRADIENT was the most accurate and consistent technique for target volume contouring. GRADIENT was also the most robust for varying imaging conditions. GRADIENT has the potential to play an important role for tumor delineation in radiation therapy planning and response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Practical Carrier Multiplication: Donor/Acceptor Codoped Si Nanocrystals in SiO 2

Carrier multiplication (CM) is an interesting fundamental phenomenon with application potential in optoelectronics and photovoltaics, and it has been shown to be promoted by quantum confinement effects in nanostructures. However, mostly due to the short lifetimes of additional electron-hole (e-h) pairs generated by CM, major improvements of quantum dot devices that exploit CM are limited. Here we investigate CM in SiO2 solid state dispersions of phosphorus and boron codoped Si nanocrystals (NCs): an exotic variant of Si NCs whose photoluminescence (PL) emission energy, the optical bandgap, is significantly red-shifted in comparison to undoped Si NCs. By combining the results obtained by ultrafast induced absorption (IA) with PL quantum yield (PL QY) measurements, we demonstrate CM with a long (around 100 us) lifetime of the additional e-h pairs created by the process, similar as previously reported for undoped Si NCs, but with a significantly lower CM threshold energy. This constitutes a significant step toward the practical implementation of Si-based NCs in optoelectronic devices: we demonstrate efficient CM at the energy bandgap optimal for photovoltaic conversion.

36 MATERIALS SCIENCE↗

Insights into ultraviolet-induced electrical degradation of thermally grown SiO{sub 2}/4H-SiC(0001) interface

The harmful impact of ultraviolet (UV) light irradiation on thermally grown SiO{sub 2}/4H-SiC structures was investigated by means of electrical measurements of metal-oxide-semiconductor (MOS) capacitors. Unlike Si-based MOS devices, significant electrical degradation, such as positive flatband voltage (V{sub FB}) shift and hysteresis in the capacitance-voltage (C-V) curves of SiC-MOS capacitors was induced by UV irradiation with a low-pressure mercury lamp. The interfacial fixed charge density increased with UV-irradiation (22.6 mW/cm{sup 2} for 16 h) to 1.7 × 10{sup 12} cm{sup −2}, which was an order of magnitude larger than that of the as-grown SiO{sub 2}/SiC interface. A detailed study based on single wavelength solid-state UV lasers revealed that there was a threshold photon energy at around 5 eV and a moderate dependence of UV-induced degradation on temperature. These experimental findings imply that pre-existing inactive defects accumulated at the thermally grown SiO{sub 2}/SiC interface were transformed to active carrier traps with high-energy UV irradiation through transparent SiO{sub 2} layers.

36 MATERIALS SCIENCE↗

X-ray tomographic in-service inspection of girth welds - The European project TomoWELD

The new standard 'ISO 17636-2:2013: Non-destructive testing of welds - Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors', defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.

36 MATERIALS SCIENCE↗

Investigation of InGaN/GaN laser degradation based on luminescence properties

Degradation of InGaN/GaN laser diode (LD) is investigated based on the luminescence properties. Gradual degradation of the LD is presented with the threshold current increase and the slope efficiency decrease. The cathodoluminescence and photoluminescence characterizations of the LD show a dislocation independent degradation of the active region under the ridge. Detailed studies on the temperature-dependent micro-photoluminescence and the electroluminescence indicate that the degradation of the LD is attributed to the generation of non-radiative recombination centers in the local multiple quantum well regions with lower indium content. The activation energy of the non-radiative recombination centers is about 10.2 meV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved inertial confinement fusion gamma reaction history 12 C gamma-ray signal by direct subtraction

The Gamma Reaction History Diagnostic (GRH) located at the National Ignition Facility (NIF) measures time resolved gamma rays released from inertial confinement fusion experiments by converting emitted gamma rays into Cherenkov light. Imploded capsules have a bright 4.4 MeV gamma ray from fusion neutrons inelastically scattering with carbon atoms in the remaining ablator. The strength of 4.4 MeV gamma ray line is proportional to the capsule’s carbon ablator areal density and can be used to understand the dynamics and energy budget of a carbon-based ablator capsule implosion. Historically, the GRH’s four gas cells use the energy thresholding from the Cherenkov process to forward fit an estimation of the experiment’s complete gamma ray spectrum by modeling the surrounding environment in order to estimate the 4.4 MeV neutron induced carbon gamma ray signal. However, the high number of variables, local minima and uncertainties in detector sensitivities and relative timing had prevented routine use of the forward fit to generate carbon areal density measurements. A new, more straightforward, process of direct subtraction of deconvolved signals was developed to simplify the extraction of the carbon areal density. Beryllium capsules are used as a calibration to measure a capsule environment with no carbon signal. This is then used to appropriately subtract and isolate the carbon signal on shots with carbon ablators. The subtraction algorithm achieves good results across all major capsule campaigns, achieving similar results to the forward fit. This method is now used routinely to measure carbon areal density for NIF shots.

47 OTHER INSTRUMENTATION↗

Jülich-Bonn-Washington model for pion electroproduction multipoles

Pion electroproduction off the proton is analyzed in a new framework based on a general parametrization of transition amplitudes, including constraints from gauge invariance and threshold behavior. Data with energies 1.13 GeV < W < 1.6 GeV and Q 2 below 6 Ge V 2 are included. The model is an extension of the latest Jülich-Bonn solution incorporating constraints from pion-induced and photoproduction data. Here, performing large-scale fits (≈10 5 data) we find a set of solutions with $χ^2_{\text{dof}}$ = 1.69–1.81 which allows us to assess the systematic uncertainty of the approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of the {phi}(1680) and the Y(2175) in e{sup +}e{sup -}{yields}{phi}{pi}{sup +}{pi}{sup -}

The cross sections for e{sup +}e{sup -}{yields}{phi}{pi}{sup +}{pi}{sup -} and e{sup +}e{sup -}{yields}{phi}f{sub 0}(980) are measured from threshold to {radical}(s)=3.0 GeV using initial-state radiation. The analysis is based on a data sample of 673 fb{sup -1} collected on and below the {upsilon}(4S) resonance with the Belle detector at the KEKB asymmetric-energy e{sup +}e{sup -} collider. First measurements are reported for the resonance parameters of the {phi}(1680) in the {phi}{pi}{sup +}{pi}{sup -} mode: m=(1689{+-}7{+-}10) MeV/c{sup 2} and {gamma}=(211{+-}14{+-}19) MeV/c{sup 2}. A structure at {radical}(s)=2.1 GeV/c{sup 2}, corresponding to the so called Y(2175), is observed; its mass and width are determined to be (2079{+-}13{sub -28}{sup +79}) MeV/c{sup 2} and (192{+-}23{sub -61}{sup +25}) MeV/c{sup 2}, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AutoReP: Automatic ReLU Replacement for Fast Private Network Inference

The proliferation of the Machine-Learning-As-A-Service (MLaaS) market has brought to light a number of clients’ data privacy and security concerns. One promising solution is private inference (PI) techniques using cryptographic primitives. These techniques often come with high computation and communication overhead associated with the non-linear operator such as ReLU. Several approaches have been developed in reducing the number of ReLU operations, however, they either require a heuristic threshold selection or introduce significant accuracy drop. This work presents AutoReP, a gradient-based framework for non-linear operators reduction that aims to mitigate these concerns from a systematic perspective. AutoReP automates the process of discrete selection of ReLU and polynomial functions on neurons to accelerate PI applications. We also introduce distribution-aware polynomial approximation (DaPa) to accurately approximate ReLUs under given distribution, preserving model expressivity. Our experimental results demonstrate significant accuracy improvements of 6.12% (94.31%, 12.9K ReLU budget, CIFAR-10), 8.39% (74.92%, 12.9K ReLU budget, CIFAR-100), and 9.45% (63.69%, 55K ReLU budget, Tiny-ImageNet) over current state-of-the-art methods, e.g., SNL. Morever, AutoReP is applied to EfficientNet-B2 on ImageNet dataset, and achieved 75.55% accuracy with 176.1 × ReLU budget reduction.

Peng, Hongwu↗

Monolithically Integrated $\varepsilon$-Ge/In x Ga 1-x As Quantum Well Laser Design: Experimental and Theoretical Investigation

Here, we have analyzed the electrical and optical phenomenon occurring in a $\varepsilon$-Ge/In x Ga 1-x -Ge/In x Ga 1-x As quantum well (QW) laser through self-consistent physical solvers calibrated using in-house experimental results. A separate confinement heterostructure QW design is proposed to enable lasing from tensile strained germanium ($\varepsilon$-Ge/In x Ga 1-x -Ge) in the range of 1.55 um to 4 um wavelengths as a function of QW thickness and indium (In) composition. Different recombination mechanisms were analyzed as a function of tensile strain in $\varepsilon$-Ge/In x Ga 1-x -Ge QW. Minority carrier lifetime and band alignment are key attributes of a QW laser, which were measured using microwave photoconductive decay and x-ray photoelectron spectroscopy (as a function of In composition), respectively. The transition point of Ge to a direct bandgap material is re-affirmed to be at $\varepsilon$-Ge/In x Ga 1-x = 1.6% (In ~24%) and the transition from type I to type II for $\varepsilon$-Ge/In x Ga 1-x -Ge/In x Ga 1-x As QW is found to be at In ~55%. Also, the transition to a TM mode dominant laser is identified at In ~15%. Using a tunable waveguide design to optimize confinement as a function of In composition, strain, wavelength, QW thickness, refractive index, and geometry, the $\varepsilon$-Ge/In x Ga 1-x -Ge QW laser design provided a net material gain of ~2000 cm -1 and a threshold current density of ~5 kA/cm 2 , which is an improvement over existing Ge based lasers. In conclusion, the impact of In composition and QW thickness on the band structure, polarized gain spectra, and various lasing metrics were analyzed to show $\varepsilon$-Ge/In x Ga 1-x -Ge/InGaAs QW lasers as promising for integrated photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated quantitative 3D analysis of aorta size, morphology, and mural calcification distributions

Purpose: The purpose of this work is to develop a fully automated pipeline to compute aorta morphology and calcification measures in large cohorts of CT scans that can be used to investigate the potential of these measures as imaging biomarkers of cardiovascular disease. Methods: The first step of the automated pipeline is aorta segmentation. The algorithm the authors propose first detects an initial aorta boundary by exploiting cross-sectional circularity of aorta in axial slices and aortic arch in reformatted oblique slices. This boundary is then refined by a 3D level-set segmentation that evolves the boundary to the location of nearby edges. The authors then detect the aortic calcifications with thresholding and filter out the false positive regions due to nearby high intensity structures based on their anatomical location. The authors extract the centerline and oblique cross sections of the segmented aortas and compute the aorta morphology and calcification measures of the first 2500 subjects from COPDGene study. These measures include volume and number of calcified plaques and measures of vessel morphology such as average cross-sectional area, tortuosity, and arch width. Results: The authors computed the agreement between the algorithm and expert segmentations on 45 CT scans and obtained a closest point mean error of 0.62 ± 0.09 mm and a Dice coefficient of 0.92 ± 0.01. The calcification detection algorithm resulted in an improved true positive detection rate of 0.96 compared to previous work. The measurements of aorta size agreed with the measurements reported in previous work. The initial results showed associations of aorta morphology with calcification and with aging. These results may indicate aorta stiffening and unwrapping with calcification and aging. Conclusions: The authors have developed an objective tool to assess aorta morphology and aortic calcium plaques on CT scans that may be used to provide information about the presence of cardiovascular disease and its clinical impact in smokers.

60 APPLIED LIFE SCIENCES↗

WE-D-BRA-06: IMRT QA with ArcCHECK: The MD Anderson Experience

Purpose: The objective of this project was to report our initial IMRT QA results and experience with the SunNuclear ArcCHECK. Methods: Three thousand one-hundred and sixteen cases were treated with IMRT or VMAT at our institution between October 2013 and September 2014. All IMRT/VMAT treatment plans underwent Quality Assurance (QA) using ArcCHECK prior to therapy. For clinical evaluation, a Gamma analysis is performed following QA delivery using the SNC Patient software (Sun Nuclear Corp) at the 3%/3mm level. QA Gamma pass rates were analyzed based on categories of treatment site, technique, and type of MLCs. Our current clinical threshold for passing a QA (Tclin) is set at a Gamma pass rate greater than 90%. We recorded the percent of failures for each category, as well as the Gamma pass rate threshold that would Result in 95% of QAs to pass (T95). Results: Using Tclin a failure rate of 5.9% over all QAs was observed. The highest failure rate was observed for gynecological (22%) and the lowest for CNS (0.9%) treatments. T95 was 91% over all QAs and ranged from 73% (gynecological) to 96.5% (CNS) for individual treatments sites. T95 was lower for IMRT and non-HD (high definition) MLCs at 88.5% and 94.5%, respectively, compared to 92.4% and 97.1% for VMAT and HD MLC treatments, respectively. There was a statistically significant difference between the passing rates for IMRT vs. VMAT and for HD MLCs vs. non-HD MLCs (p-values << 0.01). Gynecological, IMRT, and HD MLC treatments typically include more plans with larger field sizes. Conclusion: On average, Tclin with ArcCHECK was consistent with T95, as well as the 90% action level reported in TG-119. However, significant variations between the examined categories suggest a link between field size and QA passing rates and may warrant field size-specific passing rate thresholds.

60 APPLIED LIFE SCIENCES↗

Detection of Disruptions in the High-β Spherical Torus NSTX

This paper describes the prediction of disruptions based on diagnostic data in the high-β spherical torus NSTX. The disruptive threshold values on many signals are examined. In some cases, raw diagnostic data can be used as a signal for disruption prediction. In others, the deviations of the plasma data from simple models provides the signal used to determine the proximity to disruption. However, no single signal and threshold value can form the basis for disruption prediction in NSTX; thresholds that produce an acceptable false positive rate have too large a missed or late warning rate, while combinations that produce an acceptable rate of missed or late warnings have an unacceptable false positive rate. To solve this problem, a novel means of combining multiple threshold tests has been developed. After being properly tuned, this algorithm can produce a false positive rate of 2.8%, with a late warning rate of 3.7% when applied to a database of ~2000 disruptions collected from three run campaigns. Furthermore, many of these false positives are triggered by near-disruptive MHD events that might indeed be disruptive in larger plasmas with more stored energy. However, the algorithm is less efficient at detecting the MHD event that prompts the disruption process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of moving base simulation motion cues utilizing washout technique

The present study was conducted to derive data on non-visual motion thresholds utilizing washout technique, and to develop specific threshold values for use as washout parameters. It describes the results of acceleration detection studies carried out using the NASA MSFC General Purpose Simulator which provides six degree-of-freedom cab motion. A series of experiments was performed to test the hypothesis that constant velocity visual cues might suppress non-visual deceleration sensitivity. The psychophysical method employed was the forced-choice procedure which theoretically yields a pure sensitivity measure. The MSFC General Purpose Simulator was programmed to provide velocity ramps in three axes - pitch, fore-aft translation, and vertical translation. Data were collected with and without a constant velocity visual input. Comparison of the current results with classical data suggested significantly greater sensitivity of the human observer to fore-aft accelerations than has generally been reported, sensitivity tending to depend on motion direction and sign of velocity change.

Kirkpatrick, M., III↗

Guide to the evaluation of human exposure to noise from large wind turbines

Guidance for evaluating human exposure to wind turbine noise is provided and includes consideration of the source characteristics, the propagation to the receiver location, and the exposure of the receiver to the noise. The criteria for evaluation of human exposure are based on comparisons of the noise at the receiver location with the human perception thresholds for wind turbine noise and noise-induced building vibrations in the presence of background noise.

Stephens, D. G.↗

A comparison between coherent and noncoherent mobile systems in large Doppler shift, delay spread, and C/I environment

The performance and implementation complexity of coherent and of noncoherent QPSK and GMSK modulation/demodulation techniques in a complex mobile satellite systems environment, including large Doppler shift, delay spread, and low C/I, are compared. We demonstrate that for large f(sub d)T(sub b) products, where f(sub d) is the Doppler shift and T(sub b) is the bit duration, noncoherent (discriminator detector or differential demodulation) systems have a lower BER floor than their coherent counterparts. For significant delay spreads, e.g., tau(sub rms) greater than 0.4 T(sub b), and low C/I, coherent systems outperform noncoherent systems. However, the synchronization time of coherent systems is longer than that of noncoherent systems. Spectral efficiency, overall capacity, and related hardware complexity issues of these systems are also analyzed. We demonstrate that coherent systems have a simpler overall architecture (IF filter implementation-cost versus carrier recovery) and are more robust in an RF frequency drift environment. Additionally, the prediction tools, computer simulations, and analysis of coherent systems is simpler. The threshold or capture effect in low C/I interference environment is critical for noncoherent discriminator based systems. We conclude with a comparison of hardware architectures of coherent and of noncoherent systems, including recent trends in commercial VLSI technology and direct baseband to RF transmit, RF to baseband (0-IF) receiver implementation strategies.

Feher, Kamilo↗

Binarization of Gray-Scaled Digital Images Via Fuzzy Reasoning

A new fast-computational technique based on fuzzy entropy measure has been developed to find an optimal binary image threshold. In this method, the image pixel membership functions are dependent on the threshold value and reflect the distribution of pixel values in two classes; thus, this technique minimizes the classification error. This new method is compared with two of the best-known threshold selection techniques, Otsu and Huang-Wang. The performance of the proposed method supersedes the performance of Huang-Wang and Otsu methods when the image consists of textured background and poor printing quality. The three methods perform well but yield different binarization approaches if the background and foreground of the image have well-separated gray-level ranges.

Dominquez, Jesus A.↗