Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Effectiveness of supercritical-CO 2 and N 2 huff-and-puff methods of enhanced oil recovery in shale fracture networks using microfluidic experiments

Current oil recovery methods in hydraulically fractured shale reservoirs have a low recovery efficiency of about 10%. The objective of this work is to investigate the effectiveness of nitrogen and supercritical carbon dioxide in the huff-and-puff method for enhanced oil recovery as a means to re-energize reservoirs and improve recovery rates. Here, we conduct direct visualization experiments with a microfluidic system to reveal the mechanisms and to quantify the recovery rates of oil from fracture networks. We compared the effectiveness of water, nitrogen and supercritical carbon dioxide at reservoir conditions in a process mimicking the huff-and-puff method in both dead-end and connected fracture systems. The microfluidic chips were made of glass and placed in a confining pressure system pressurized to 10 MPa, 50 °C. The system was allowed to equilibrate, and then depressurized to simulate huff-and-puff oil recovery. Fluorescence microscope images were continuously taken to visualize and calculate residual oil saturation as a function of pressure drawdown. As the system was depressurized from 10 MPa, gas exsolution from the oil liquid phase, including bubble nucleation, growth, and coalescence, appeared to be the main driver for mobilizing oil from the fracture networks. Injection of supercritical CO 2 resulted in the highest recovery rate with an average end-point recovery of about 90% in the connected fracture network and 60% in the dead-end fracture network. N 2 has lower solubility in oil and hence showed a lower recovery rate of 40% in the connected fracture network and 25% in the dead-end fracture network. Injection of water had no effect on oil mobilization since water is insoluble, immiscible and incompressible. The main mechanism of enhanced recovery was gas exsolution from the liquid phase as pressure was decreased below the bubble point pressure. Because the gas was distributed throughout the oil phase, bubble nucleation, growth, coalescence, and elongation occurred throughout the fracture network. Expansion of the gas forced oil out of the network through piston displacement in continuous oil areas and film flow in the dispersed oil areas. Bubbles began as spheres and grew until they touched the fracture walls where they elongated along the fracture length. The bubble growth rate depended on local mass transfer from liquid to gas phase and gas volume expansion due to pressure drop. The efficiency of the huff-and-puff process is dependent on the solubility and miscibility of the injection fluid with oil. High gas solubility allows for more bubble nucleation, growth and expansion during the depressurization cycle.

58 GEOSCIENCES↗

Overview and Performance of the LOFTID Instrumentation Suite

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an enabling technology that facilitates atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to overcome the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher payload mass and/or volume, higher landing altitude at Mars). On November 10th, 2022 the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. After the primary payload was delivered to its orbit, the LOFTID reentry vehicle was inflated, positioned, and then separated to reenter Earth’s atmosphere at a velocity of 8.1km/s, ultimately splashing down safely in the Pacific Ocean. The flight successfully demonstrated a 6m diameter, 70-deg sphere-cone HIAD on a high-energy orbital reentry. This demonstration has provided invaluable fight data essential to characterize the vehicle performance and support the ongoing effort to further scale the HIAD technology to vehicles of 10m in diameter or greater. Aeroshells of this scale are applicable to near-term commercial applications and future NASA robotic and human exploration missions. LOFTID incorporated an extensive instrumentation suite totaling over 150 science measurements. This included thermocouples, total heat flux sensors, and a radiometer to characterize the aeroheating environment and aeroshell thermal response. An Inertial Measurement Unit (IMU), Global Positioning System (GPS), and flush air data system was included to allow post-flight reconstruction of the vehicle trajectory including a decoupling of the aerodynamics from the atmospheric density. Loadcells were used to measure HIAD structural response during entry, and cameras (both visual-spectrum and infrared) were mounted on the aft segment looking at the aeroshell to monitor structural deflection and surface temperature distribution. Finally, a single up-look camera was included which has provided a surprising amount of science potential from the spectacular footage. In addition to the primary instrumentation suite, a new Fiber Optic Sensing System (FOSS) was used to provide global temperature distributions as a technology demonstration. The system provided over 200 thermal measurements creating a thermal map for the backside of the nose Flexible Thermal Protection System. Another pair of FOSS cables were run along the rigid center structure and measured the temperature response to the vehicle wake environment. The LOFTID instrumentation suite leveraged Agency-wide expertise, with hardware development occurring at Ames Research Center, Langley Research Center, Marshall Space Flight Center, and Armstrong Flight Research Center. This presentation will discuss the instrumentation selected for LOFTID to capture the HIAD performance during the high-energy orbital reentry flight test, provide examples of data products, and snippets of the spectacular reentry video.

G T Swanson↗

Overview and Performance of the LOFTID Instrumentation Suite

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an enabling technology that facilitates atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to overcome the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher payload mass and/or volume, higher landing altitude at Mars). On November 10th, 2022 the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. After the primary payload was delivered to its orbit, the LOFTID reentry vehicle was inflated, positioned, and then separated to reenter Earth’s atmosphere at a velocity of 8.1km/s, ultimately splashing down safely in the Pacific Ocean. The flight successfully demonstrated a 6m diameter, 70-deg sphere-cone HIAD on a high-energy orbital reentry. This demonstration has provided invaluable fight data essential to characterize the vehicle performance and support the ongoing effort to further scale the HIAD technology to vehicles of 10m in diameter or greater. Aeroshells of this scale are applicable to near-term commercial applications and future NASA robotic and human exploration missions. LOFTID incorporated an extensive instrumentation suite totaling over 150 science measurements. This included thermocouples, total heat flux sensors, and a radiometer to characterize the aeroheating environment and aeroshell thermal response. An Inertial Measurement Unit (IMU), Global Positioning System (GPS), and flush air data system was included to allow post-flight reconstruction of the vehicle trajectory including a decoupling of the aerodynamics from the atmospheric density. Loadcells were used to measure HIAD structural response during entry, and cameras (both visual-spectrum and infrared) were mounted on the aft segment looking at the aeroshell to monitor structural deflection and surface temperature distribution. Finally, a single up-look camera was included which has provided a surprising amount of science potential from the spectacular footage. In addition to the primary instrumentation suite, a new Fiber Optic Sensing System (FOSS) was used to provide global temperature distributions as a technology demonstration. The system provided over 200 thermal measurements creating a thermal map for the backside of the nose Flexible Thermal Protection System. Another pair of FOSS cables were run along the rigid center structure and measured the temperature response to the vehicle wake environment. The LOFTID instrumentation suite leveraged Agency-wide expertise, with hardware development occurring at Ames Research Center, Langley Research Center, Marshall Space Flight Center, and Armstrong Flight Research Center. This paper will discuss the instrumentation selected for LOFTID, a summary of sensor in-flight performance, and will provide examples of data products from the post-flight analysis effort.

Gregory T Swanson↗

Overview and Performance of the LOFTID Instrumentation Suite

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an enabling technology that facilitates atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to overcome the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher payload mass and/or volume, higher landing altitude at Mars). On November 10th, 2022 the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. After the primary payload was delivered to its orbit, the LOFTID reentry vehicle was inflated, positioned, and then separated to reenter Earth’s atmosphere at a velocity of 8.1km/s, ultimately splashing down safely in the Pacific Ocean. The flight successfully demonstrated a 6m diameter, 70-deg sphere-cone HIAD on a high-energy orbital reentry. This demonstration has provided invaluable fight data essential to characterize the vehicle performance and support the ongoing effort to further scale the HIAD technology to vehicles of 10m in diameter or greater. Aeroshells of this scale are applicable to near-term commercial applications and future NASA robotic and human exploration missions. LOFTID incorporated an extensive instrumentation suite totaling over 150 science measurements. This included thermocouples, total heat flux sensors, and a radiometer to characterize the aeroheating environment and aeroshell thermal response. An Inertial Measurement Unit (IMU), Global Positioning System (GPS), and flush air data system was included to allow post-flight reconstruction of the vehicle trajectory including a decoupling of the aerodynamics from the atmospheric density. Loadcells were used to measure HIAD structural response during entry, and cameras (both visual-spectrum and infrared) were mounted on the aft segment looking at the aeroshell to monitor structural deflection and surface temperature distribution. Finally, a single up-look camera was included which has provided a surprising amount of science potential from the spectacular footage. In addition to the primary instrumentation suite, a new Fiber Optic Sensing System (FOSS) was used to provide global temperature distributions as a technology demonstration. The system provided over 200 thermal measurements creating a thermal map for the backside of the nose Flexible Thermal Protection System. Another pair of FOSS cables were run along the rigid center structure and measured the temperature response to the vehicle wake environment. The LOFTID instrumentation suite leveraged Agency-wide expertise, with hardware development occurring at Ames Research Center, Langley Research Center, Marshall Space Flight Center, and Armstrong Flight Research Center. This paper will discuss the instrumentation selected for LOFTID, a summary of sensor in-flight performance, and will provide examples of data products from the post-flight analysis effort.

Greg Swanson↗

Steady Nuclear Combustion in Rockets

The astrophysical theory of stationary nuclear reactions in stars is applied to the conditions that would be met in the practical engineering cases that would differ from the former, particularly with respect to the much lower combustion pressures, dimensions of the reacting volume, and burnup times. This application yields maximum rates of hear production per unit volume of reacting gas occurring at about 10(exp 8) K in the cases of reactions between the hydrogen isotopes, but yields higher rates for heavier atoms. For the former, with chamber pressures of the order of 100 atmospheres, the energy production for nuclear combustion reaches values of about 10(exp 4) kilocalories per cubic meter per second, which approaches the magnitude for the familiar chemical fuels. The values are substantially lower for heavier atoms, and increase with the square of the combustion pressure. The half-life of the burnup in the fastest reactions may drop to values as low as those for chemical fuels so that, despite the high temperature, the radiated energy can remain smaller than the energy produced, particularly if an inefficiently radiating (i.e., easily completely ionized reacting material like hydrogen), is used. On the other hand, the fraction of completely ionized particles in the gases undergoing nuclear combustion must not exceed a certain upper limit because the densities (approximately 10(exp -10) grams per cubic centimeter)) lie in the range of high vacua and only for the previously mentioned fraction of nonionized particles can mean free paths be retained small enough so that the chamber diameters of several dozen meters will suffice. Under these conditions it appears that continuously maintained stable nuclear reactions at practical pressures and dimensions are fundamentally possible and their application can be visualized as energy sources for power plants and propulsion units.

Saenger, E.↗

Noise suppressed partial volume correction for cardiac SPECT/CT

Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility. Conclusions: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.

60 APPLIED LIFE SCIENCES↗

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗

Large-deviation joint statistics of the finite-time Lyapunov spectrum in isotropic turbulence

One of the hallmarks of turbulent flows is the chaotic behavior of fluid particle paths with exponentially growing separation among them while their distance does not exceed the viscous range. The maximal (positive) Lyapunov exponent represents the average strength of the exponential growth rate, while fluctuations in the rate of growth are characterized by the finite-time Lyapunov exponents (FTLEs). In the last decade or so, the notion of Lagrangian coherent structures (which are often computed using FTLEs) has gained attention as a tool for visualizing coherent trajectory patterns in a flow and distinguishing regions of the flow with different mixing properties. A quantitative statistical characterization of FTLEs can be accomplished using the statistical theory of large deviations, based on the so-called Cramér function. To obtain the Cramér function from data, we use both the method based on measuring moments and measuring histograms and introduce a finite-size correction to the histogram-based method. We generalize the existing univariate formalism to the joint distributions of the two FTLEs needed to fully specify the Lyapunov spectrum in 3D flows. The joint Cramér function of turbulence is measured from two direct numerical simulation datasets of isotropic turbulence. Results are compared with joint statistics of FTLEs computed using only the symmetric part of the velocity gradient tensor, as well as with joint statistics of instantaneous strain-rate eigenvalues. When using only the strain contribution of the velocity gradient, the maximal FTLE nearly doubles in magnitude, highlighting the role of rotation in de-correlating the fluid deformations along particle paths. We also extend the large-deviation theory to study the statistics of the ratio of FTLEs. The most likely ratio of the FTLEs λ{sub 1} : λ{sub 2} : λ{sub 3} is shown to be about 4:1:−5, compared to about 8:3:−11 when using only the strain-rate tensor for calculating fluid volume deformations. The results serve to characterize the fundamental statistical and geometric structure of turbulence at small scales including cumulative, time integrated effects. These are important for deformable particles such as droplets and polymers advected by turbulence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗

Parallel runway requirement analysis study. Volume 1: The analysis

The correlation of increased flight delays with the level of aviation activity is well recognized. A main contributor to these flight delays has been the capacity of airports. Though new airport and runway construction would significantly increase airport capacity, few programs of this type are currently underway, let alone planned, because of the high cost associated with such endeavors. Therefore, it is necessary to achieve the most efficient and cost effective use of existing fixed airport resources through better planning and control of traffic flows. In fact, during the past few years the FAA has initiated such an airport capacity program designed to provide additional capacity at existing airports. Some of the improvements that that program has generated thus far have been based on new Air Traffic Control procedures, terminal automation, additional Instrument Landing Systems, improved controller display aids, and improved utilization of multiple runways/Instrument Meteorological Conditions (IMC) approach procedures. A useful element to understanding potential operational capacity enhancements at high demand airports has been the development and use of an analysis tool called The PLAND_BLUNDER (PLB) Simulation Model. The objective for building this simulation was to develop a parametric model that could be used for analysis in determining the minimum safety level of parallel runway operations for various parameters representing the airplane, navigation, surveillance, and ATC system performance. This simulation is useful as: a quick and economical evaluation of existing environments that are experiencing IMC delays, an efficient way to study and validate proposed procedure modifications, an aid in evaluating requirements for new airports or new runways in old airports, a simple, parametric investigation of a wide range of issues and approaches, an ability to tradeoff air and ground technology and procedures contributions, and a way of considering probable blunder mechanisms and range of blunder scenarios. This study describes the steps of building the simulation and considers the input parameters, assumptions and limitations, and available outputs. Validation results and sensitivity analysis are addressed as well as outlining some IMC and Visual Meteorological Conditions (VMC) approaches to parallel runways. Also, present and future applicable technologies (e.g., Digital Autoland Systems, Traffic Collision and Avoidance System II, Enhanced Situational Awareness System, Global Positioning Systems for Landing, etc.) are assessed and recommendations made.

Ebrahimi, Yaghoob S.↗

Machine learning methods for fission product identification from Bragg curves

A fission time projection chamber (fission-TPC) was developed to provide precise neutron-induced fission measurements for several major actinides. As fission fragments lose energy in one of the gas volumes of the fission-TPC, energy loss information is captured and may be used to determine fission product yields as the stopping power of an ion is dependent on the atomic number. The work presented here demonstrates the ability to apply machine learning techniques for Bragg curve classification. A set of one million energy loss curves for 24 different fission-fragment elements was generated using common stopping power software. A ResNet architecture optimized for 1D data was used to train, test, and validate a model for light and heavy fission fragments using the simulated data. The resultant classification accuracy for the light and heavy fragments indicates that this could be a viable method for elemental classification of data from the fission-TPC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contrast-Enhanced Proton Radiography for Patient Set-up by Using X-Ray CT Prior Knowledge

Purpose: To obtain a contrasted image of the tumor region during the setup for proton therapy in lung patients, by using proton radiography and x-ray computed tomography (CT) prior knowledge. Methods and Materials: Six lung cancer patients' CT scans were preprocessed by masking out the gross tumor volume (GTV), and digitally reconstructed radiographs along the planned beam's eye view (BEV) were generated, for a total of 27 projections. Proton radiographies (PR) were also computed for the same BEV through Monte Carlo simulations. The digitally reconstructed radiograph was subtracted from the corresponding proton image, resulting in a contrast-enhanced proton radiography (CEPR). Michelson contrast analysis was performed both on PR and CEPR. The tumor region was then automatically segmented on CEPR and compared to the ground truth (GT) provided by physicians in terms of Dice coefficient, accuracy, precision, sensitivity, and specificity. Results: Contrast on CEPR was, on average, 4 times better than on PR. For 10 lateral projections (±45° off of 90° or 270°), although it was not possible to distinguish the tumor region in the PR, CEPR offers excellent GTV visibility. The median ± quartile values of Dice, precision, and accuracy indexes were 0.86 ± 0.03, 0.86 ± 0.06, and 0.88 ± 0.02, respectively, thus confirming the reliability of the method in highlighting tumor boundaries. Sensitivity and specificity analysis demonstrated that there is no systematic over- or underestimation of the tumor region. Identification of the tumor boundaries using CEPR resulted in a more accurate and precise definition of GTV compared to that obtained from pretreatment CT. Conclusions: In most proton centers, the current clinical protocol is to align the patient using kV imaging with bony anatomy as a reference. We demonstrated that CEPR can significantly improve tumor visualization, allowing better patient set-up and permitting image guided proton therapy (IGPT)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Smart Proxy Modeling of SACROC CO2-EOR

Large CO2-enhanced oil recovery (EOR) projects usually contain an abundance of geological and good performance data. While this volume of data leads to robust models, it often results in difficult to manage, slow-running numerical flow models. To dramatically reduce the numerical run-times associated with the traditional simulation techniques, this work investigated the feasibility of using artificial intelligence and machine learning technologies to develop a smart proxy model of the Scurry Area Canyon Reef Operators Committee (SACROC) oilfield, located in the Permian Basin, TX, USA. Smart proxy models can be used to facilitate injection-production optimization for CO2-EOR projects. The use of a coupled grid-based, and well-based surrogate reservoir model (SRM) (also known as smart proxy modeling) was investigated as the base of the optimization. A fit-for-purpose coupled SRM, which executes in seconds, was built based on high-resolution numerical reservoir simulation models of the northern platform of the SACROC oilfield. This study is unique as it is the first application of coupled SRM at a large oilfield. The developed SRM was able to identify the dynamic reservoir properties (pressure, saturations, and component mole-fraction) at every grid-block, along with the production characteristics (pressure and rate) at each well. Recent attempts to use machine learning and pattern recognition to build proxy models have been simplistic, with limited predictive capabilities. The geological model used in this study is comprised of more than nine million grid blocks. The high correlation between the actual component and SRM, which can be visualized by mapping the properties, along with the fast footprint of the developed model demonstrate the successful application of this methodology.

Vida, Gholami↗

Discovery of a visual T-dwarf triple system and binarity at the L/T transition

We present new high contrast imaging of eight L/T transition brown dwarfs (BDs) using the NIRC2 camera on the Keck II telescope. One of our targets, the T3.5 dwarf 2MASS J08381155+1511155, was resolved into a hierarchal triple with projected separations of 2.5 ± 0.5 AU and 27 ± 5 AU for the BC and A(BC) components, respectively. Resolved OSIRIS spectroscopy of the A(BC) components confirms that all system members are T dwarfs. The system therefore constitutes the first triple T-dwarf system ever reported. Using resolved photometry to model the integrated-light spectrum, we infer spectral types of T3 ± 1, T3 ± 1, and T4.5 ± 1 for the A, B, and C components, respectively. The uniformly brighter primary has a bluer J – K{sub s} color than the next faintest component, which may reflect a sensitive dependence of the L/T transition temperature on gravity, or alternatively divergent cloud properties among components. Relying on empirical trends and evolutionary models we infer a total system mass of 0.034-0.104 M {sub ☉} for the BC components at ages of 0.3-3 Gyr, which would imply a period of 12-21 yr assuming the system semimajor axis to be similar to its projection. We also infer differences in effective temperatures and surface gravities between components of no more than ∼150 K and ∼0.1 dex. Given the similar physical properties of the components, the 2M0838+15 system provides a controlled sample for constraining the relative roles of effective temperature, surface gravity, and dust clouds in the poorly understood L/T transition regime. For an age of 3 Gyr we estimate a binding energy of ∼20 × 10{sup 41} erg for the wide A(BC) pair, which falls above the empirical minimum found for typical BD binaries, and suggests that the system may have been able to survive a dynamical ejection during formation. Combining our imaging survey results with previous work we find an observed binary fraction of 4/18 or 22{sub −8}{sup +10}% for unresolved spectral types of L9-T4 at separations ≳ 0.''1. This translates into a volume-corrected frequency of 13{sub −6}{sup +7}%, which is similar to values of ∼9%-12% reported outside the transition. Our reported L/T transition binary fraction is roughly twice as large as the binary fraction of an equivalent L9-T4 sample selected from primary rather than unresolved spectral types (6{sub −4}{sup +6}%); however, this increase is not yet statistically significant and a larger sample is required to settle the issue.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear Analysis of ITER - Paper 129

The world record fusion power production is 16.1 MW (5.7x10{sup 18} n/s). This was achieved at JET in 1995. The neutron budget during that experimental campaign was 2.5x10{sup 20} neutrons. In the first few seconds of an ITER full power pulse, the neutron production will exceed that the total from the entire history of previous controlled fusion experiments. It is envisaged that ITER should produce as much as 700 MW of fusion power. (This is the maximum envisaged power production from the plasma and does not include power multiplication in the blankets or shielding). This equates to the production of 2.48x10{sup 20} 14-MeV neutrons/s which will give an uncollided flux at the first wall of approximately 4x10{sup 13} n/cm{sup 2}/s and a total with the addition of the collided flux of some 10{sup 14} n/cm{sup 2}/s. For safety and licensing purposes it is the responsibility of ITER to satisfy the host state regulations and must limit doses to the public and staff. Furthermore, sufficient shielding must be provided to ensure that all components function adequately; and for decommissioning, ITER has a responsibility to reduce the volume and radio-toxicity of waste. The construction, operational and decommissioning phases of ITER are expected to last in excess of 30 years and the nuclear issues will be of critical importance throughout this time. The huge leap in neutron production in fusion experiments means that extensive nuclear analysis is required for ITER and it is the thesis of this paper that it is required at an unprecedented level. This is because of the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry and the complexity of the sources and level of detail required. As a result of this unprecedented challenge the latest techniques for analysis, variance reduction and data display are being employed and in some cases being specifically developed. In this paper a few of the many representative examples of nuclear analysis will illustrate the thesis. The paper includes an examination of areas where further development could be made in the areas of radiation shield and nuclear analysis. Extensive nuclear analysis is required at ITER and the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry, and the complexity of the sources mean that analysis is required at an unprecedented level of detail and quality. The latest techniques for analysis, variation reduction and data display are being employed and in some cases being specifically developed. Developments are required in areas of analysis, data visualization and experimental verification. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Diurnal Cycle of Convection in the East Pacific ITCZ during EPIC-2001

During the last three weeks of September 2001, the EPIC-2001 intensive field campaign focused on studies of deep convection in the ITCZ over the Mexican warm pool region (10N, 95W) of the East Pacific. This study focuses on the pronounced observed diurnal cycle of environmental and convective parameters within the experiment domain. Data from three primary sources are examined: the R/V Ronald H. Brown C-band weather radar, 4-hourly soundings from the Brown and the Global Atmospherics, Inc. National Lightning Detection Network (long range product). Satellite data from TRMM, GOES and OV-1 are also used. The domain boundary layer shows a robust daily evolution of moist enthalpy (as reflect by equivalent potential temperature, theta-e, or wet bulb potential temperature, theta-w), with contributions from changes in both dry and moist entropy. Peak theta-w is found after local nightfall; the average diurnal range of theta-w is approximately 1 deg C. A composite diurnal cycle of convective properties was derived from the C-band volume scans, sampled continuously through the experiment at 10 minute updates. Products derived from the volumetric data include a surface PPI, 15 and 30 dBZ echo top height, vertically integrated liquid, and 6 km (mixed phase region) reflectivity CAPPIs. For almost all products, the parameter means showed virtually no diurnal cycle. However, for the upper-level products, the parameter spectra showed a clear peak in the occurrence of deep/vigorous convection (the "tail end of the distribution") between 7-9 UTC (1-3 AM local), while overall frequency of occurrence peaked later, from 12-15 UTC (6-9 AM local). This represents a daily "outbreak" of isolated deep cells a couple of hours after sunset and subsequent growth, organization and decay through the nighttime hours. The coherence of the diurnal cycle of the convective spectrum is impressive given the wide variety of convective organization observed during the experiment, and given the modulation by passage of 3-5 day easterly waves. While earlier satellite OLR composites suggested an offshore coastal migration of storms into the domain at night, examination of the 150 km and 300 km range radar products showed little evidence of such organization; almost all convection developed "in-place" within the analysis domain. Consistent with the diurnal thermodynamic and microphysical evolution, a clear cycle in cloud-to-ground (CG) lightning occurrence was observed. The local CG diurnal cycle is significantly stronger than the satellite-derived tropical ocean diurnal cycle of total (IC+CG) lightning. Flash rates of 3-4 fl/min were often visually observed after nightfall; these are fairly 'healthy' flash rates for tropical ocean storms, and the domain was qualitatively noted to be unusually lightning-productive by the R/V Brown crew (also consistent with satellite-based climatologies).

Boccippio, Dennis J.↗

Building a Bilingual Google Earth Engine Dashboard to Increase Accessibility to Long-term Time Series Remote Sensing Data for Monitoring Saline System Changes in Chile’s Atacama Desert

Saline systems, consisting of salt flats, ponds, and marshes, provide vital water resources to wildlife and communities in northern Chile’s Atacama Desert, one of the driest regions in the world. Mining is extensive in the Atacama, which contains 30% of the world’s lithium reserves and is abundant in potassium and boron. The groundwater that feeds into salt marshes and ponds is extracted in large volumes for mining operations, limiting the availability of water for ecosystems. However, identifying long-term and large-scale environmental impacts from local lithium mining on the saline systems is limited by region inaccessibility and terrain variability. Open access satellite imagery and cloud computing technology has made studying Atacama saline systems feasible and allowed for collaboration across different agencies and countries. The NASA DEVELOP Program partnered with Chile’s la Universidad de La Serena and Servicio Nacional de Geología y Minería (SERNAGEOMIN) to create the Saline Analysis Tool (SalT) in Google Earth Engine (GEE). SalT is used to analyze the extent and distribution of remote saline systems in the Atacama from 1986 to the present day. The tool filters Landsat 5 Thematic Mapper (TM) and Landsat 8 Operational Land Imager (OLI) data from GEE’s data catalog and creates a single composite image per year for analysis. Additional output analyses include land cover classification, Normalized Difference Vegetation Index (NDVI) and Normalized Difference Water Index (NDWI) raster images that can be displayed on the map interface or exported. The tool can also generate time-lapse videos and charts displaying NDVI, NDWI, and land cover over time. A key feature of the tool is the use of a bilingual graphical user interface to make analysis accessible and customizable to different users’ needs—SalT provides options to select an analysis area, analysis time period, and outputs to display or export. The tool also incorporates new Earth observations as they are added to GEE’s catalog. The ability to easily visualize and analyze long-term remote sensing imagery will enable SERNAGEOMIN and la Universidad de la Serena to continually monitor changes in these saline systems and inform future land management policy.

NASA DEVELOP↗