Search NASA⌕ Search

SEARCH · Search NASA

Results for “100”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Characterization of a 100-kW Class Nested-Channel Hall Thruster

The next generation of electric propulsion consists of systems in excess of 300 kW of power. These systems enable a wide variety of missions, including crewed missions to near-Earth asteroids and Mars. Hall thrusters are a particularly attractive technology for these missions, but development and demonstration of 100-kW class devices has been limited to date. Here, a 100-kW class three-channel nested Hall thruster called the X3 was operated up to 102 kW total discharge power. The three channels of the X3 can be operated in any combination, providing seven unique configurations and a total throttling envelope of 2-200 kW. Previous testing of the X3 was limited to 30 kW and found that it was not providing state-of-the-art performance.Two low-power test campaigns were completed at the University of Michigan which identified potential mechanisms for this under-performance. Improvements to the thruster were made before a high-power performance characterization at NASA Glenn Research Center. There, the X3 was fired on xenon propellant from 5-102 kW total power. The thruster demonstrated stable operation in all seven channel combinations at discharge voltages from 300 V to 500 V and three different current densities. All seven channel combinations demonstrated similar performance at a given discharge voltage and current density. The largest thrust recorded was 5.4 N, and total efficiency and specific impulse ranged from 0.54 to 0.67 and 1800 seconds to 2650 seconds, respectively.In addition to the performance measurements, a suite of plasma diagnostics and a high-speed camera were used to study the operation of the thruster in greater detail. The probe results are compared against those in the literature and demonstrate that the X3, even in multi-channel operation, is producing similar charge, mass, current, and voltage utilization efficiencies as state of the art single-channel Hall thrusters. High-speed camera analysis identified that the X3 operated with similar discharge current oscillations at all conditions tested. Additionally, a preliminary calculation of cross-channel ingestion and its effect on thruster efficiency is made. This work represents the highest total power (102 kW), thrust (5.4 N), and discharge current (247 A) demonstrated by a Hall thruster to date, improvements of 6 percent, 64 percent, and 119 percent respectively over previous values. These results are discussed in the context of continued high-power Hall thruster development and future mission applications.

Hall, Scott James↗

High-Power Performance of a 100-kW Class Nested Hall Thruster

The performance of a three-channel, 100-kW class nested Hall thruster was evaluated on xenon propellant for total powers up to 102 kW at NASA Glenn Research Center. The thruster demonstrated stable operation in all seven available channel combinations at discharge voltages from 300 V to 500 V and three different current densities. The resulting test matrix contained forty-six unique conditions ranging from 5 to 102 kW total power and 16 to 247 A discharge current. At each operating condition, thruster performance was measured, and from these measurements specific impulse and efficiency were calculated. All seven channel combinations showed similar performance at a given discharge voltage and current density. The largest thrust recorded was 5.4 N ± 0.1 N at 99 kW, 400 V discharge voltage. Total efficiency and specific impulse ranged from 0.54 to 0.67 ± 0.03 and 1800 seconds to 2650 seconds ± 60 seconds, respectively. It was found that the thrust of the three channels firing together was not larger than the sum of each channel firing individually. Discharge current oscillations were also characterized with peak-to-peak and root-mean-square values and with power spectral density analysis. The implications of these results are discussed in the context of operation beyond 100 kW, as well as the general viability of NHT technology for future mission applications.

Hall, Scott J.↗

High Power Demonstration of a 100 kW Nested Hall Thruster System

The XR-100 team successfully completed high power system testing of a Nested Hall Thruster system made up of the X3 Nested Hall Thruster, a modular Power Processing Unit, and a 5 valve Mass Flow Controller as the culmination of work performed under a NASA NextSTEP program. The test campaign attained several key firsts, including highest directly measured thrust of an electric propulsion (EP) string, highest demonstrated current of an EP string, and highest power operation of an EP string at thermal equilibrium published to date. Most importantly, the XR-100 system testing demonstrated that a 100 kW-class Nested Hall Thruster system has comparable performance and behavior to current state-of-the-art mid power Hall Thrusters, validating that the heritage technology can be scaled up to 100+ kW

Shark, Sarah↗

High Power Demonstration of a 100 kW Nested Hall Thruster System

The XR-100 team successfully completed high power system testing of a Nested Hall Thruster system made up of the X3 Nested Hall Thruster, a modular Power Processing Unit, and a 5 valve Mass Flow Controller as the culmination of work performed under a NASA NextSTEP program. The test campaign attained several key firsts, including highest directly measured thrust of an electric propulsion (EP) string, highest demonstrated current of an EP string, and highest power operation of an EP string at thermal equilibrium published to date. Most importantly, the XR-100 system testing demonstrated that a 100 kW-class Nested Hall Thruster system has comparable performance and behavior to current state-of-the-art mid power Hall Thrusters, validating that the heritage technology can be scaled up to 100+ kW

Shark, Sarah↗

100-kHz Rate Rayleigh Imaging for Combustion and Flow Diagnostics

Two-dimensional (2D) Rayleigh scattering (RS) imaging at an ultrahigh repetition rate of 100 kHz is demonstrated in non-reacting and reacting flows employing a high-energy burst-mode laser system. Image sequences of flow mixture fraction were directly derived from high-speed RS images. Additionally, a 2D instantaneous flow velocity field at 100 kHz was obtained through optical-flow-based analysis of the RS images. The technique was also applied to study turbulent flames having a near-constant Rayleigh cross section. The demonstrated high-speed RS technique in conjunction with optical-flow-based analysis provides non-intrusive, simultaneous measurements of the flow mixing and velocity field, extending the measurement capability of the RS technique to high-speed non-reacting and reacting flows.

Jiang, Naibo↗

Performance and High-Speed Characterization of a 100-kW Nested Hall Thruster

The performance of a three-channel, 100-kW class nested Hall thruster was evaluated on xenon propellant for total powers up to 102 kW. The thruster demonstrated stable operation in all seven available channel combinations at discharge voltages from 300 V to 500 V and three different current densities. The resulting test matrix contained forty-six unique conditions ranging from 5 to 102 kW total power and 16 to 247 A discharge current. At each operating condition, thrust and telemetry was measured, and from these measurements specific impulse and efficiency were calculated. All seven channel combinations showed similar performance at a given discharge voltage and current density. The largest thrust recorded was 5.4 N ± 0.1 N at 99 kW, 400 V discharge voltage. Total efficiency and specific impulse ranged from 0.54 to 0.67 ± 0.03 and 1800 seconds to 2650 seconds ± 60 seconds, respectively. It was found that the thrust of the three channels firing together was not larger than the sum of each channel firing individually. Discharge current oscillations were also characterized with peak-to-peak and root-mean-square values and with high-speed camera analysis, which provide insight into how the discharge channels oscillate, and how those oscillations are affected by the presence of other operating channels. The implications of these results are discussed in the context of operation beyond 100 kW, as well as the general viability of NHT technology for future mission applications.

High-power↗

Simultaneous 100-kHz Acetone Planar Laser-Induced Fluorescence and OH* Chemiluminescence in a Linear Non-Premixed Detonation Channel

Reactant mixing and combustion are investigated in an optically accessible, self-excited linear detonation combustor. The mixing field is captured using 100 kHz planar laser-induced fluorescence (PLIF) imaging of acetone as a tracer in the fuel supply, while 100 kHz chemiluminescence imaging of excited-state hydroxyl (OH*) radicals simultaneously resolves the evolution of the detonation wave. Time sequences are acquired over multiple detonation cycles in each test, with acetone-PLIF images collected along multiple orthogonal planes to reveal the complex three-dimensional topography of the fuel distribution. The instantaneous and phase averaged acetone-PLIF images enable measurement of key fuel injection characteristics, such as the injector recovery time, fuel jet velocity, and refill height for a range of operating conditions. Instantaneous and phase-averaged measurements of acetone-PLIF with the time-coincident OH* chemiluminescence images also reveal a number key features, such as fuel stratification and weak detonation in the injector near field, incomplete combustion and deflagration behind the detonation wave, vitiation and deflagration of reactants ahead of the detonation wave, and fuel and oxidizer recovery time mismatch leading to combustion inefficiency. These measurements significantly enhance the ability to obtain detailed information on the intracycle and intercycle spatiotemporal evolution of the reactant refill process and its coupled effects on the detonation wave structure and propagation.

Propulsion↗

Hybrid pulse-burst / cross-correlation DGV for high-speed flow measurements at 100 kHz

Hybrid pulse-burst Doppler global velocimetry (PB-DGV)/pulse-burst, cross-correlation DGV (PB-CC-DGV) was demonstrated for the first time in the NASA Langley 4-foot Supersonic Unitary Plan Wind Tunnel, allowing simultaneous acquisition of mean and instantaneous high-repetition-rate velocity fields. The technique was used to make planar velocity measurements across an oblique shockwave generated by a large splitter plate set at a -2° angle of attack in a Mach 2.4 flow. Sequences of more than 100 consecutive instantaneous velocity images were obtained at a rate of 100 kHz. Velocity fields from both aspects of the hybrid measurement indicated errors less than 1-percent of anticipated velocities. Likewise, all assessments of measurement precision were approximately 1.6-percent of the local velocities. Additional demonstrations in different flowfields including a subsonic axi-symmetric jet and a supersonic Mars reentry vehicle model further illustrate the utility of the new hybrid method.

laser↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

HIGH-SENSITIVITY 100- TO 300-GC RADIOMETERS

High thermal sensitivity 100 to 300 gc radiometers with 4 mm reflex klystrons as local oscillator sources for operation in the 2.1 and 1.3 mm atmospheric absorption region

RADIOMETER↗