Search NASASearch

SEARCH · Search NASA

Results for “12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,771 records · Page 7

Characterization of ceramic fuel powder packing fractions to support INFLUX

Triply periodic minimal surface (TPMS)-based structures show marked potential in novel nuclear reactor fuel designs, as their high surface area-to-volume ratio increases the efficiency of heat transfer out of the fuel, enabling safer, more innovative reactor designs. This milestone report addresses the role of dUO 2 powder processing route on the fill behavior of TPMS-based cladding shells to understand and advance the feasibility of manufacturing TPMS-based nuclear fuel forms. dUO 2 powder was processed through either a dry granulation route, varying consolidation pressure, or through milling, varying milling time, milling method and milled size distribution. The lowest tapped bulk densities (TBD), but best powder flowabilities, were obtained when testing unprocessed dUO 2 powder which was prone to self-agglomeration and formed low-density spheroids. The highest TBD and lowest flowabilities were obtained when using powder produced by hammer-milling dUO 2 powder to pass through a 200-mesh sieve, which led to particles with angular morphologies. Powder produced by dry granulation exhibited TBD that varied according to the consolidation pressure used to form the initial pellets and exhibited improved flowabilities when compared to hammer-milled material. Because of the large span of granule sizes formed as well as the irregular shape associated with the granules, a packing fraction of 0.69 was achieved, exceeding the analytical solution for random close packing of mono-sized spheres. TPMS polymer shells were loaded with unprocessed, granulated, and hammer-milled dUO 2 powders, and their qualitative packing behaviors were analyzed using x-ray computed tomography (xCT). TBDs calculated after loading TPMS polymer shells were 10-20% lower when compared to tapped bulk density measurements taken in a glass graduated cylinder, indicating a non-trivial impact on the tapped bulk density of either the TPMS channel size, TPMS channel surface material, powder cohesiveness, or a combination of the two parameters. A metallic zircaloy-4 TPMS shell will be loaded with hammer-milled dUO 2 powder upon receipt of the shell from Oak Ridge National Laboratory (ORNL) and shipped to Idaho National Labs (INL) for subsequent hot isostatic pressing (HIP) densification experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Optimization of the FRIB beam dump: a hybrid genetic algorithm and reinforcement learning approach

The operational envelope of high-power-density systems, such as particle accelerators and advanced nuclear energy systems, is critically constrained by the need to manage extreme thermal loads. To address this, we present a novel hybrid optimization framework combining a genetic algorithm (GA) with a soft actor-critic (SAC) deep reinforcement learning agent. This framework was applied to a practical high-heat-flux problem: redesigning the beam dump at the Facility for Rare Isotope Beams (FRIB) for a power upgrade from 20 kW to 50 kW. The resulting design, validated by three-dimensional conjugate heat transfer simulations, suppresses hazardous hot spots and yields a markedly more uniform temperature distribution. This provides a robust operating margin, increasing the average power-handling capability by 72% relative to the current design, demonstrating the framework’s potential to solve complex thermal management challenges in both accelerator technology and advanced nuclear systems.

Accelerator

Optical Vibrational Spectroscopic Investigation of Natural and Synthetic Analogs of Uranyl Oxyhydroxyhydrate Minerals

Uranyl oxy-hydroxy-hydrate minerals are common alteration products of uraninite (UO2+x) which is chemically and structurally analogous to uranium dioxide nuclear fuel. Therefore, structural and spectroscopic investigations of these alteration minerals and their analogous anthropogenic counterparts can provide insight into the environmental behavior of nuclear fuel cycle materials. Previously, we compiled available vibrational spectroscopic data for uranyl minerals in the Compendium of Uranium Raman and Infrared Experimental Spectra (CURIES) and found that only 37% of known uranyl oxy-hydroxy-hydrate minerals had spectra readily available in the literature and existing databases for inclusion therein. Furthermore, no available infrared spectra for this mineral group were included in CURIES. To expand our understanding of the spectroscopic features of uranyl oxy-hydroxy-hydrates and the structural origins thereof, we collected, and now include in CURIES, Raman and infrared spectra for an additional 12 uranyl hydroxide phases. To better understand the impact of structural and compositional variations of these phases on their spectroscopic features, we compare Raman spectra of different anion sheet topological groups and of analogous phases hosting different counter cations. We identify spectroscopic variations related to differences in equatorial bonding and structural changes as a result of cation substitution. We also prepare a uranyl hydroxide phase via hydrolysis of uranyl fluoride (UO2F2) as an analog of hydrolysis reactions that occur in nuclear fuel cycle materials; and we find that the alteration product of UO2F2, despite chemical and structural similarities to uranyl oxy-hydroxy-hydrate minerals, is readily distinguishable from related mineral phases using Raman spectroscopy. In this work, we provide new insights into the structural origins of spectroscopic features in uranyl oxy-hydroxy-hydrate minerals, improve the average Raman spectrum for this group of minerals, and thereby improve capabilities for identifying these mineral species and related anthropogenic phases using Raman spectroscopy.

Barth, Brodie [ORNL] (ORCID:0000000256142601)

Relithiation process for direct regeneration of cathode materials from spent lithium-ion batteries

A method for the regeneration of cathode material from spent lithium-ion batteries is provided. The method includes dissolving a lithium precursor in a polyhydric alcohol to form a solution. Degraded cathode material containing lithium metal oxides are dispersed into the solution under mechanical stirring, forming a mixture. The mixture is heat treated within a reactor vessel or microwave oven. During this heat treatment, lithium is intercalated into the degraded cathode material. The relithiated electrode material is collected by filtration, washing with solvents, and drying. The relithiated electrode material is then ground with a lithium precursor and thermally treated at a relatively low temperature for a predetermined time period to obtain regenerated cathode material.

Belharouak, Ilias

Review of Particle Physics

The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 3,200 new measurements from 903 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 118 reviews are updated, including many that are heavily revised.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Method for implant and anneal for high voltage field effect transistors

In an example, the present invention provides a method of forming a semiconductor device on a gallium and nitrogen containing material. The method includes providing a substrate member comprising a surface region, the substrate member comprising a gallium and nitrogen bearing material. The method includes causing an implanted species to electrically activate the implant profile while removing one or more crystalline damage from the epitaxial material to change the amorphous state to a single crystalline state, and thereby creating a substantially electrically activated crystalline material.

Shealy, James R.

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke

Rapid Coal-Ash Characterization using Geophysical Methods & Machine Learning

Coal combustion products (CCP) are challenging to delineate in heterogeneous field settings. Conventional methods (test pits, coring, and laboratory analyses) are labor-intensive, slow, invasive, and provide sparse spatial coverage. This study evaluates whether rapid non-invasive geophysical screening methods—induced polarization (IP), magnetic susceptibility, and nuclear magnetic resonance (NMR) —combined with surface colorimetry (RGB_24), can discriminate CCP-soil mixtures and provide reliable estimates of CCP content. Laboratory measurements were collected on five CCP-soil mixtures (series) and modeled using (i) a linear baseline, (ii) a calibrated non-linear (power-mean) model, and (iii) a machine-learning (ML) Random Forest approach, with validation via leave-one-series-out and site-specific tests. Across the five series, individual signals—particularly IP and magnetic susceptibility—were strongly predictive of ash content but were consistently outperformed by combined models. The pooled calibrated non-linear and ML models captured the observed non-linearity and achieved high accuracy and precision, improving on linear fits. Colorimetry showed the weakest direct relationship with ash content for the tested samples but improved performance when included in multi-signal models. At pre-selected 3.5% decision threshold, calibrated and ML approaches yielded near-perfect classification (Matthews correlation coefficient ˜ 1), suggesting strong practical operability for field screening. Additionally, field-analog tests highlighted the role of endmembers—accuracy declined without access to end-member measurements but was largely recovered by collecting a minimal labeled pair for local recalibration. With end members, accuracy remained high. Globally trained models performed well on three operational unknowns; however, series-specific refits provided the most accurate predictions. Overall, these results highlight the potential of combining rapid geophysics and minimal local calibration for improved coal-ash delineation.

Peshtani, Klaudio

Overcoming the Entropy Penalty of Direct Air Capture for Efficient Gigatonne Removal of Carbon Dioxide

Atmospheric carbon poses an existential threat to civilization via global climate change. Hundreds of gigatonnes of carbon dioxide must be removed from earth’s atmosphere in the next three decades, necessitating a low-cost, energy-efficient process to extract low concentrations of carbon dioxide for conversion to a stable material permanently stored for thousands of years. In this work, the challenge of removing gigatonnes of CO 2 is described via the scale of effort and the thermodynamics of collecting and reducing this diffuse chemical, the accumulation of which imparts a substantial entropy penalty on any atmospheric carbon capture process. The methods of CO 2 reduction combined with upstream direct air capture (DAC) including absorption, membrane separation, and adsorption are compared with biomass torrefaction and permanent burial (BTB). A Monte Carlo model assesses the mass, energy, and economics of the full process of biomass torrefaction from biomass collection and transport to stable carbon burial to determine that 95% of scenarios could remove carbon for less than $200 per CO 2 -tonne-equivalent. Torrefied carbon is further discussed for its long-term stability and availability at the scale required to substantially mitigate the threat of climate change.

biomass

Intake runner for gaseous fuel engine, system, and method

A gaseous fuel engine system includes a hydrogen fuel supply, an engine housing having an intake port extending to a cylinder, and an intake runner. The intake runner includes a valve mount attached to a conduit and having a valve mounting face, and a gaseous fuel admission valve is mounted upon the valve mounting face. A hydrogen fuel passage extends from the valve mount through the conduit and is oriented angularly to at least one of a clamping face of the intake runner or the valve mounting face. Related apparatus and methodology is also disclosed.

Singh, Jaswinder

Iron surface corrosion in supercritical CO2 at atomic scale investigated by molecular dynamics simulations

Understanding the corrosion behavior of steels in supercritical carbon dioxide (S-CO2) is essential for ensuring the safe application of S-CO2 as a heat-transfer fluid in high-temperature energy systems, including advanced nuclear reactors. In this work, molecular dynamics (MD) simulations using ReaxFF potential are performed to explore the atomic-scale corrosion mechanisms of body-centered cubic iron (BCC-Fe) in S-CO2. The results show that CO2 molecules in S-CO2 decompose at the Fe surface, generating free C and O atoms that form Fe-C and Fe-O bonds and subsequently produce oxides and carbides. Concurrently, Fe atoms dissolve from the surface and diffuse into the S-CO2 region, resulting in interdiffusion of Fe, C and O atoms at the interface. The corrosion-layer thickness calculations show that high pressure and temperature induced by S-CO2 have stronger effects than surface orientation on the corrosion process. In addition, surface Fe atoms undergo substantial displacement under S-CO2 exposure, further accelerating corrosion. When a radiation-induced void is introduced near the Fe surface, the corrosion is enhanced. The void-matrix interface expands the reaction surface area and simultaneously induces corrosion reactions inside the bulk, resulting in a deeper penetration of C and O and thicker corrosion layers. All these results indicate that high-temperature, high-pressure and radiation-induced voids can seriously affect the corrosion of Fe in S-CO2, and must be considered to better use S-CO2 in nuclear facilities.

Li, Wenhua

Programmable Digital Devices used in Advanced Reactors

This paper introduces the concepts of common cause failure, diversity, and defense-in-depth used by the nuclear industry to analyze resilience in reactors. A survey of publicly traded and private companies building advanced reactors and their licensing status is presented. Safety and non-safety systems found in the NuScale Power design are summarized and the likely hardware and software categories used by those systems are enumerated. The importance of industry partners is highlighted. This paper also identifies an alternate path forward without industry partners to advance the knowledge needed to use artificial intelligence to analyze HBOMs and SBOMs to better understand reactor resiliency.

cybersecurity

Bypass heat exchanger configuration to reroute core flow

A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.

Terwilliger, Neil

Recognizing Blazars Using Radio Morphology from the VLA Sky Survey

Abstract Blazars are radio-loud active galactic nuclei whose jets have a very small angle to our line of sight. Observationally, the radio emissions are mostly compact or compact-core with a one-sided jet. With 2.″5 resolution at 3 GHz, the Very Large Array Sky Survey (VLASS) enables us to resolve the structure of some blazar candidates in the sky north of decl. −40°. We introduce an algorithm to classify radio sources as either blazar-like or non-blazar-like based on their morphology in the VLASS images. We apply our algorithm to three existing catalogs, including one of the known blazars (Roma-BzCAT) and two blazar candidates identified by Wide-field Infrared Survey Explorer colors and radio emission (WIBRaLS, KDEBLLACS). We show that in all three catalogs, there are objects with morphologies inconsistent with being blazars. Considering all the catalogs, more than 12% of the candidates are unlikely to be blazars, based on this analysis. Notably, we show that 3% of the Roma-BzCATconfirmedblazars could be a misclassification based on their VLASS morphology. The resulting table with all sources and their radio morphological classification is available online.

Astronomy & Astrophysics

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI