Search NASA⌕ Search

SEARCH · Search NASA

Results for “3d imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Model and Standard Operating Procedures Supporting Signal Variation Flow Graph Analysis

This document will describe the principles of the Signal Variation Flow Technique, and the uncertainty models generated using it. We focus on the capture of the variation between the ideal signal and the measured signal. The ideal signal is defined to represent the signal output of a system whose full state behavior is known, with no variation in environment or during operation, and whose photons trajectories are not modified by the object. A CT uncertainty analysis is the result of two main steps. First, the radiography regime extends from the source to the collected image, which is 2D in the case of standard CT. This maps all upstream uncertainties into the variation observed on the radiograph and captures all variation in the physical domain. Second, the reconstruction regime extends from the captured images to the reconstructed 3D image. This regime is purely in the mathematical domain and corrects reconstruction algorithm artifacts/anomalies. The present work focuses on building the model through the radiography regime. The reconstruction regime is expected to be largely a study of algorithmic sensitivity, requiring the definition of a range of standardized tests through which the algorithms would be run. Radiographic variation would then be mapped through reconstruction sensitivities to predict the signal variation in the final image. An incomplete list for the reconstructed image variation output basis includes voxel density, edge blur and length variation, in analogous fashion to the basis functions presented in this work. The signal variation occurs in several forms at the radiograph. These forms are gathered into a complete basis set of functions describing all variation on the radiograph. The scale of each basis function is calculated independently via a specific SVFG. This includes 0D pixel noise (0DI), 0D energy noise (0DE), 1D blur (1DB), 1D length (1DL) or 2D position (2DP). These models are orthogonal in that they each explore a space in the signal variation domain that cannot be reached by the other basis functions. The variation basis functions, and associated SVFG models are split by output dimensionality, a term loosely used for categorization, and explained further below.

42 ENGINEERING↗

Computer-generated 3D ultrasound images of the carotid artery

A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.

Selzer, Robert H.↗

Computed Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding

In friction stir welding (FSW), a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and is carried with the macro-flow of the weld metal. By using CT images, a 3-dimensional (3D) image of the lead flow pattern can be reconstructed. CT imaging was found to be a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.

Schneider, Judy↗

High-Resolution Imaged-Based 3D Reconstruction Combined with X-Ray CT Data Enables Comprehensive Non-Destructive Documentation and Targeted Research of Astromaterials

Providing web-based data of complex and sensitive astromaterials (including meteorites and lunar samples) in novel formats enhances existing preliminary examination data on these samples and supports targeted sample requests and analyses. We have developed and tested a rigorous protocol for collecting highly detailed imagery of meteorites and complex lunar samples in non-contaminating environments. These data are reduced to create interactive 3D models of the samples. We intend to provide these data as they are acquired on NASA's Astromaterials Acquisition and Curation website at http://curator.jsc.nasa.gov/.

Blumenfeld, E. H.↗

3D Backscatter Imaging System

Systems and methods for imaging an object using backscattered radiation are described. The imaging system comprises both a radiation source for irradiating an object that is rotationally movable about the object, and a detector for detecting backscattered radiation from the object that can be disposed on substantially the same side of the object as the source and which can be rotationally movable about the object. The detector can be separated into multiple detector segments with each segment having a single line of sight projection through the object and so detects radiation along that line of sight. Thus, each detector segment can isolate the desired component of the backscattered radiation. By moving independently of each other about the object, the source and detector can collect multiple images of the object at different angles of rotation and generate a three dimensional reconstruction of the object. Other embodiments are described.

Turner, D. Clark↗

Multidimensional Processing and Visual Rendering of Complex 3D Biomedical Images

The proposed technology uses advanced image analysis techniques to maximize the resolution and utility of medical imaging methods being used during spaceflight. We utilize COTS technology for medical imaging, but our applications require higher resolution assessment of the medical images than is routinely applied with nominal system software. By leveraging advanced data reduction and multidimensional imaging techniques utilized in analysis of Planetary Sciences and Cell Biology imaging, it is possible to significantly increase the information extracted from the onboard biomedical imaging systems. Year 1 focused on application of these techniques to the ocular images collected on ground test subjects and ISS crewmembers. Focus was on the choroidal vasculature and the structure of the optic disc. Methods allowed for increased resolution and quantitation of structural changes enabling detailed assessment of progression over time. These techniques enhance the monitoring and evaluation of crew vision issues during space flight.

Sams, Clarence F.↗

General approaches for shear-correcting coordinate transformations in Bragg coherent diffraction imaging. Part I

This two-part article series provides a generalized description of the scattering geometry of Bragg coherent diffraction imaging (BCDI) experiments, the shear distortion effects inherent in the 3D image obtained from presently used methods and strategies to mitigate this distortion. Part I starts from fundamental considerations to present the general real-space coordinate transformation required to correct this shear, in a compact operator formulation that easily lends itself to implementation with available software packages. Such a transformation, applied as a final post-processing step following phase retrieval, is crucial for arriving at an undistorted, correctly oriented and physically meaningful image of the 3D crystalline scatterer. As the relevance of BCDI grows in the field of materials characterization, the available sparse literature that addresses the geometric theory of BCDI and the subsequent analysis methods are generalized here. This geometrical aspect, specific to coherent Bragg diffraction and absent in 2D transmission CDI experiments, gains particular importance when it comes to spatially resolved characterization of 3D crystalline materials in a reliable nondestructive manner. This series of articles describes this theory, from the diffraction in Bragg geometry to the corrections needed to obtain a properly rendered digital image of the 3D scatterer. Part I of this series provides the experimental BCDI community with the general form of the 3D real-space distortions in the phase-retrieved object, along with the necessary post-retrieval correction method. Part II builds upon the geometric theory developed in Part I with the formalism to correct the shear distortions directly on an orthogonal grid within the phase-retrieval algorithm itself, allowing more physically realistic constraints to be applied. Taken together, Parts I and II provide the X-ray science community with a set of generalized BCDI shear-correction techniques crucial to the final rendering of a 3D crystalline scatterer and for the development of new BCDI methods and experiments.

36 MATERIALS SCIENCE↗

Quantitatively accounting for the effects of surface topography on the oxidation kinetics of additive manufactured Hastelloy X processed by electron beam melting

In this work, the effects of surface roughness on the high-temperature corrosion of nickel-based superalloy X produced through electron-beam melting (EBM) additive manufacturing were studied. Surface area of samples in the rough, as-fabricated condition was measured using a 2D cross-section image analysis technique and a 3D image analysis technique. To verify the accuracy of surface area measurements, oxidation testing of samples in the as-fabricated and polished conditions was performed; polished sample oxidation curves were then compared to the as-fabricated sample oxidation curves before and after being adjusted using obtained surface area measurements. It was found that the 2D technique accurately measured surface area and accounted for the overlapping features present on EBM sample surfaces, whereas the 3D technique did not. Further, it was also observed that oxidation kinetics were moderately faster on the alloy X samples in the as-fabricated condition than for the polished condition.

36 MATERIALS SCIENCE↗

Perspectives of active Si photonics devices for data communication and optical sensing

Si photonics has made rapid progress in research and commercialization in the past two decades. While it started with electronic–photonic integration on Si to overcome the interconnect bottleneck in data communications, Si photonics has now greatly expanded into optical sensing, light detection and ranging (LiDAR), optical computing, and microwave/RF photonics applications. From an applied physics point of view, this perspective discusses novel materials and integration schemes of active Si photonics devices for a broad range of applications in data communications, spectrally extended complementary metal–oxide–semiconductor (CMOS) image sensing, as well as 3D imaging for LiDAR systems. We also present a brief outlook of future synergy between Si photonic integrated circuits and Si CMOS image sensors toward ultrahigh capacity optical I/O, ultrafast imaging systems, and ultrahigh sensitivity lab-on-chip molecular biosensing.

electronic band structure↗

Tomography Analysis of Orion Artemis 1 Heatshield Sample

The Orion spacecraft, under NASA's Artemis program, is an integral step in humanity's ambitions of deep space exploration, including our return to the Moon and subsequent mission to Mars. The performance of Orion's heatshield is central to ensuring the safety and success of such missions. This presentation offers a comprehensive overview of the process used in and findings derived from tomography scans of an Artemis 1 heatshield sample executed at the Lawrence Berkeley National Laboratory's Advanced Light Source. These tomography scans captured high-resolution X-Ray images of the heatshield's microstructure, allowing advanced imaging to be employed for 3D image segmentation and visualization of the sample. The Porous Media Analysis (PuMA) software stands central to our analysis, offering robust computational algorithms and methodologies to digitally compute properties of the heatshield material. The presentation discusses the following derived metrics: - Volume fractions, representing the spatial distribution and amounts of various components throughout the heatshield’s depth. - Porosity and crack distributions, offering insights into the void space within the material, critical for understanding the heatshield's structural integrity. - Fiber orientation, detailing the alignment and arrangement of fibers, significant for material orthotropy. - Permeability estimates, quantifying the passage of gas through the material, relevant for re-entry conditions and pyrolysis gasses. One distinctive feature of this study is the comparative evaluation against data obtained from tomography scans of the Exploration Flight Test-1 (EFT-1) heatshield. Such a comparison offers multiple insights, including evaluation of the consistency and repeatability of manufacturing processes as well as understanding of any evolutionary changes in heatshield design or material properties.

Micro-tomography↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗