Search NASA⌕ Search

SEARCH · Search NASA

Results for “4D STEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE↗

TEM Approaches for Microstructure-Informed Prediction of Mechanical Properties in Structural Alloys

Predicting the mechanical performance of structural alloys from their evolving microstructure remains a major challenge in materials science, particularly for nuclear structural materials, where irradiation-induced defects span multiple types and length scales and interact through complex mechanisms. The dispersed barrier hardening (DBH) [1] and Friedel–Kroupa–Hirsch (FKH) [2,3] models have been widely used to evaluate the hardening contributions of individual obstacles and to estimate tensile strength from quantified microstructures; however, when multiple size-dependent obstacles coexist and evolve, predicting temperature-dependent tensile strength becomes significantly more complex, and a fully consistent hardening model is still lacking. Transmission electron microscopy (TEM) plays a central role in refining hardening models and enabling predictive assessments of tensile strength evolution by providing quantitative characterization of dislocations, irradiation-induced defects (e.g., dislocation loops and cavities), precipitates, and grain structure (Fig. 1.). These experimentally measured defect densities are incorporated into physically based hardening models with size- and shape- dependent obstacle strengths [4], using root-sum-square superposition for obstacles of comparable strength and linear superposition for dissimilar ones [5]. In addition, recent advances in TEM [6-8], including high-resolution imaging, 4D-STEM strain mapping, EDS/EELS elemental analysis, and flash-polishing-based TEM specimen preparation and extraction-replica methods (Fig. 2), further improve the accuracy of microstructural quantification. By comparison with prior studies as well as our own results, we show that when TEM-derived microstructural information is carefully integrated with physically grounded hardening models, yield strength (or irradiation-induced hardening) measured at room temperature can be predicted with good quantitative agreement across multiple alloy classes. In-situ TEM combined with high-temperature mechanical testing represents an important next step for refining hardening models by directly probing dislocation–obstacle interactions across varying irradiation doses and temperatures [9]. Because the barrier strength factor (α) depends on both temperature and obstacle size, it should not be treated as a constant fitting parameter; rather, it must be explicitly evaluated to achieve physically meaningful predictions of mechanical behaviour at operating temperatures. This presentation therefore discusses why all strengthening contributions (e.g., Peierls stress, solid-solution strengthening, voids, bubbles, dislocation loops, dislocation lines, and grain boundaries) must be considered collectively, why appropriate superposition methods are essential when obstacles possess different barrier strength factors, how hardness measurements can be meaningfully related to tensile properties, and how TEM-derived microstructural information can be systematically incorporated into hardening models. More broadly, it outlines a pathway toward microstructure-informed prediction of mechanical properties and supports the goal of establishing science-based tools for evaluating structural materials in extreme environments [10].

Lin, Yan-Ru [ORNL] (ORCID:0000000339991473)↗

Strain mapping of three-dimensionally structured two-dimensional materials

Strain plays a crucial role in tuning materials’ properties, influencing their optical, electrical, and chemical performances. In two-dimensional (2D) materials, applied stress often induces out-of-plane deformation, resulting in a more intricate three-dimensional (3D) topography, where mapping the strain remains a challenge due to the limitations of conventional characterization techniques. In this work, we introduce BRIGHT (Bragg-Rod Informed, Gradient-based Height-mapping Technique), an integrated method for reconstructing both the topography and planar strain profile of 3D-structured 2D materials using nanobeam four-dimensional scanning transmission electron microscopy (4D-STEM). We apply BRIGHT to a MoS2-MoSe2 transition metal dichalcogenide (TMD) lateral heterojunctions exhibiting built-in strain and out-of-plane ripples and show that varying heterojunction widths lead to distinct surface morphologies and corresponding changes in the planar strain distribution. These results establish a foundation for more effective strain engineering in 2D materials by accounting for out-of-plane structural features, thereby enabling more precise control of strain-dependent properties.

Mireles, Adan [Rice Univ., Houston, TX (United Sta↗

Data for Magnetic Anisotropy due to Localized Structural Defects in Strained Yttrium Iron Garnet Thin Films

This dataset contains electron microscopy, magnetic, and X-ray diffraction characterization data for YIG/YSGG thin films associated with the manuscript "Magnetic anisotropy due to localized structural defects in strained yttrium iron garnet thin films". Characterizations include: scanning electron nano diffraction (SEND, or 4D-STEM), dark field transmission electron microscopy (DF-TEM), energy dispersive X-ray spectroscopy (EDS), ferrimagnetic resonance (FMR), superconducting quantum interference device (SQUID), scanning transmission electron microscopy (STEM), X-ray diffraction (XRD).

Electron microscopy↗

Elucidating the mechanical and thermal response of nanotwinned Ni alloys

Transformative advances in nanoscale materials synthesis, characterization and modeling are enabling the synthesis of materials with unprecedent properties and greater understanding of the nanoscale mechanisms that underpin these properties. Nanotwinned Cu alloys have received considerable attention due to their impressive balance of strength and ductility, but they have limited microstructural stability. Recent instantiation of nanotwins in sputter deposited Ni-Mo-W, and several commercial Ni-based superalloys, point to the potential development of a new class of high temperature materials with a very beneficial suite of mechanical and physical properties. The experimental study described in this report was undertaken to elucidate the nanoscale origins of the thermal and mechanical behavior of nanotwinned Ni alloys. Micropillar compression experiments have shown nanotwinned Ni 85 Mo 15-x W x alloys to possess unusually high strengths above 3.5GPa and enhanced microstructural stability. The strength of these nanotwinned alloys is determined by the abrupt formation of shear bands. This study focused on identifying the nanoscale trigger, or triggers, for shear banding in nanotwinned materials using in situ experiments and atomic-scale postmortem analysis. Contrasting and comparing the mechanical response and postmortem nanostructures of “Mo-rich” and “W-rich” nanotwinned specimens elucidated the importance of the lateral motion of easy glide defects that results in erasure of twins and local coarsening of the nanotwinned microstructure. This twin coarsening was then associated with very localized plasticity, strain softening, and shear band formation. The difference between alloys was further studied by considering the role of various material factors: stacking fault energy, coherent twin boundary spacing and flatness, grain size, and the interactions of solute atoms with twin and grain boundaries. The effect of alloy composition and sputtering power and temperature were also investigated and used to control twin spacing and geometry. Combined with atomic-scale simulations, these experiments insights should allow us to identify strategies for achieving concomitant ultrahigh strength and ductility in nanotwinned Ni alloys. In parallel but synergistic studies, our work was buoyed by collaborative state-of-the-art nanoscale orientation and strain mapping at the DOE National Center for Electron Microscopy (NCEM). For example, novel 4D-STEM techniques were used to acquire nanoscale strain maps. The extremely fine twin spacing limited our measurements of atomic-scale thermal expansion within twins, but recent results from NCEM suggest that it will soon be possible to conduct such measurements and to unravel the origins of the novel thermal expansion characteristics of nanotwinned Ni alloys.

36 MATERIALS SCIENCE↗

A three-dimensional reconstruction algorithm for scanning transmission electron microscopy data from thick samples

Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data and transcends the prevalent structure retrieval algorithm assumption of a very thin specimen homogenous along the optic axis. We demonstrate this approach by reconstructing the different layers of a lead iridate (Pb$_2$Ir$_2$O$_7$) and yttrium-stabilized zirconia (Y$_{0.095}$Zr$_{0.905}$O$_2$) heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction.

Brown, Hamish G↗

Advances in Molecular Beam Epitaxy Growth of Ultra-Wide Bandgap Ga2O3 Based Alloys

Gallium oxide (Ga2O3) is an emerging ultra-wide bandgap semiconductor material that has attracted attention for its potential to outperform existing SiC and GaN based devices operating at high breakdown voltages and high temperature. Isovalent alloying of In and Al in Ga2O3 provides the ability to engineer bandgap energy and strain of the material. Alloying with Al increases the bandgap energy and the theoretically achievable Baliga's figure of merit, a key measure of a material's ultimate performance limits for high power switching devices. Alloying with In introduces compressive strain and can be used to counteract the tensile strain of Al incorporation. The resulting (AlxGa1-x-yIny)2O3 alloy can be lattice-matched to commercially available Ga2O3 wafers and has a tunable bandgap energy greater than that of Ga2O3, 4.76 eV. Such lattice-matched material can be grown arbitrarily thick without the detrimental effects of elastic strain and relaxation, making it suitable for high voltage diodes and transistors. However, efforts to synthesize isovalent alloys are complicated by their tendency to phase separate into corundum Al2O3 or bixbyite In2O3. Literature reports of the quaternary (AlxGa1-x-yIny)2O3 are limited to <1% unintentional indium incorporation in In-catalyzed (AlxGa1-x)2O3. The primary limitation to quaternary growth is the limited incorporation of indium at elevated growth temperatures. This limited incorporation is due to both the volatility of indium oxide and Al and Ga cation exchange reactions which replace indium in In2O3. We report on the development of a novel high-throughput molecular beam epitaxy (MBE) technique to screen the growth conditions for the ternary alloy (InyGa1-y)2O3, and the application of these findings to the first successful synthesis of phase pure monoclinic (AlxGa1-x-yIny)2O3 by MBE. By leveraging the unique sub-oxide chemistry of Ga2O3 and in-situ monitoring of crystal properties by reflection high-energy electron diffraction (RHEED), a cyclical growth and etch-back method is developed and applied to rapidly characterize the (InyGa1-y)2O3 growth space. This cyclical method provides approximately 10x increase in experimental throughput and up to 46x improvement in Ga2O3 substrate utilization. Appropriate growth conditions for monoclinic (InyGa1- y)2O3 are identified by machine learning analysis of RHEED patterns and targeted growths are characterized ex-situ to confirm improved In incorporation. These growth conditions are then combined with established (AlxGa1-x)2O3 growth conditions to grow quaternary (AlxGa1-x-yIny)2O3 with Al mole fractions ranging from 1.4% - 24.4% and In mole fractions ranging from 3.1% to 15.5%. The chemical and optical properties of the alloys are investigated by XRD, XPS, and spectroscopic ellipsometry. A lattice-matched (AlxGa1-x-yIny)2O3 alloy is examined by 4D-STEM and the chemical and physical uniformity of Al and In incorporation are discussed.

alloy↗

Time at Temperature Abstract and Intern Poster

Current NRC regulations for BWR operations dictate that any occurrence reaching the point of Departure from Nucleate Boiling (DNB) disqualifies the use of the fuel rod for further reactor operation. That criteria does not account for duration of rate of the power increase, the corresponding effects on material properties or rewetting that may occur. Previous Anticipated Operational Occurrences (AOOs) show short durations power increase that may require limited amounts of heat removal. Industrial experience has shown evidence that fuel can reach dryout yet continue to safely operate in regular reactor conditions. The gap in research into such occurrences is the motivation for a series of experiments, including this current work. Time-at-Temperature experiments aim to identify and characterize the microstructural changes in Zircaloy-2 under oxygen-free high temperatures. This work uses the FlashDSC instrument to rapidly ramp up and down the temperature of a focus ion beam (FIB) prepared large area lift-out (LALO) of Zircaloy-2 at a rate of 10,000 K/s to desired values. The focus is to characterize the microstructure evolution, if any, of Zircaloy-2 that may impact its performance under typical BWR conditions. This characterization includes analyzing grain structure and size, secondary phase particle (SPPs) size, shape, composition, and location using Transmission Electron Microscopy (TEM). Further data collection and analysis is in progress including diffraction pattern indexing and 4D STEM processing. While current results focus on the testing and characterizing unirradiated material, future plans include expansion to irradiated material to explore the effects of rapid transition rates seen in DNB and dryout conditions on irradiationg damage and defect annealing.

36 - MATERIALS SCIENCE↗

Time at Temperature Experiments on Neutron Irradiated Zircaloy-2 using Conventional & Flash DSC

Dryout events in Boiling Water Reactors (BWRs) are currently treated by NRC regulations as automatic disqualification for continued fuel rod operation, even though this criterion does not account for the rate or duration of power increases, associated changes in material behavior, or the possibility of rewetting. Operational history from Anticipated Operational Occurrences (AOOs) shows that short, transient power excursions often demand only modest heat removal, and industry experience suggests that fuel can briefly enter dryout yet return to safe, stable operation. The lack of detailed understanding of the material response during such events motivates the present series of experiments. This study uses unique and innovative methods to investigate microstructural evolution in irradiated Zircaloy-2 exposed to high temperatures in inert environments. Differential Scanning Calorimetry (DSC) and FlashDSC are combined to build a comprehensive experimental framework capable of identifying the a–ß phase transformation in zirconium and examining defect annealing under steep thermal gradients. FlashDSC enables rapid heating and cooling of Focused Ion Beam (FIB)–prepared large-area lift-outs (LALOs) of irradiated Zircaloy-2 at rates of 1,000 K/s to peak temperatures of 600°C, 750°C, and 900°C. The goal is to determine whether these conditions produce measurable microstructural changes that could influence cladding performance in typical BWR environments. Microstructural characterization includes quantifying dislocation density and assessing secondary phase particle (SPP) size and distribution using Transmission Electron Microscopy (TEM). Ongoing analysis, such as diffraction pattern indexing and 4D STEM processing, will further refine these observations.

36 - MATERIALS SCIENCE↗

Investigation of the thermal decomposition of Pu(IV) oxalate: a transmission electron microscopy study

The degradation of the internal structure of plutonium (IV) oxalate during calcination was investigated with Transmission Electron Microscopy (TEM), electron diffraction, Electron Energy-Loss Spectroscopy (EELS), and 4D Scanning TEM (STEM). TEM lift-outs were prepared from samples that had been calcined at 300°C, 450°C, 650°C and 950°C. The resulting phase at all calcination temperatures was identified as PuO 2 with electron diffraction. The grain size range was obtained with high-resolution TEM. In addition, 4D STEM images were analyzed to provide grain size distributions. In the 300°C calcined sample, the grains were <10 nm in diameter, at 650°C, the grains ranged from 10 to 20 nm, and by 950°C, the grains were 95–175 nm across. Using the Kolmogorov-Smirnov (K-S) two sample test, it was shown that morphological measurements obtained from 4D-STEM provided statistically significant distributions to distinguish samples at the different calcination conditions. Using STEM-EELS, carbon was shown to be present in the low temperature calcined samples associated with oxalate but had formed carbon (possibly graphite) deposits in the 950°C calcined sample. This work highlights the new methods of STEM-EELS and 4D-STEM for studying the internal structure of special nuclear materials (SNM).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The structure, composition, and performance impact of a YSZ-GDC interdiffusion layer in solid oxide electrolysis cells

This study provides a combined experimental and computational investigation into the structure and impact of the cation interdiffusion layer that appears at the gadolinium doped ceria (GDC)/yttria stabilized zirconia (YSZ) interface in solid oxide electrolysis cells (SOECs). Scanning transmission electron microscopy (STEM) illustrates that a ∼0.4 μm interdiffusion layer (IDL) with an intermixed cation distribution and fine grain size forms upon sintering. STEM identifies that the interdiffusion layer exists in the cubic fluorite structure despite changes in cation composition. The interdiffusion layer microstructure formed during sintering does not change during SOEC testing at either 1.3V or heightened voltage pulse testing. Modeling predicts that ionic conductivity may decrease in the interdiffusion layer due to Coulombic trapping between mobile oxygen vacancies and excess Gd 3+ acceptor dopants. Yet, the density and continuous nature of the layer should benefit cell stability by substantially reducing the formation of SrZrO 3 , which is corroborated by STEM and Synchrotron X-ray diffraction (XRD). We conclude that the interdiffusion layer acts as a beneficial barrier to Sr diffusion, when operating in a regime where electrolyte void formation is not observed.

organic↗

Probing atomic-scale symmetry breaking by rotationally invariant machine learning of multidimensional electron scattering

Abstract The 4D scanning transmission electron microscopy (STEM) method maps the structure and functionality of solids on the atomic scale, yielding information-rich data sets describing the interatomic electric and magnetic fields, structural and electronic order parameters, and other symmetry breaking distortions. A critical bottleneck is the dearth of analytical tools that can reduce complex 4D-STEM data to physically relevant descriptors. We propose an approach for the systematic exploration of 4D-STEM data using rotationally invariant variational autoencoders (rrVAE), which disentangle the general rotation of the object from other latent representations. The implementation of purely rotational rrVAE is discussed as are applications to simulated data for graphene and zincblende structures. The rrVAE analysis of experimental 4D-STEM data of defects in graphene is illustrated and compared to the classical center-of-mass analysis. This approach is universal for probing symmetry-breaking phenomena in complex systems and can be implemented for a broad range of diffraction methods.

36 MATERIALS SCIENCE↗

Lattice Strain Measurement of Core@Shell Electrocatalysts with 4D Scanning Transmission Electron Microscopy Nanobeam Electron Diffraction

Strain engineering enables the direct modification of atomic bonding and is currently an active area of research aimed at improving electrocatalytic activity. However, directly measuring the lattice strain of individual catalyst nanoparticles is challenging, especially at the scale of a single unit cell. In this study, we quantitatively map the strain present in rhodium@platinum (core@shell) nanocube electrocatalysts using conventional aberration-corrected scanning transmission electron microscopy (STEM) and the recently developed technique of 4D-STEM nanobeam electron diffraction. We demonstrate that 4D-STEM combined with data preconditioning allows for quantitative lattice strain mapping with subpicometer precision and without the influence of scan distortions. When combined with multivariate curve resolution, 4D-STEM allows us to distinguish the nanocube core from the shell and to quantify the unit cell size as a function of distance from the core–shell interface. Our results demonstrate that 4D-STEM has significant precision and accuracy advantages in strain metrology of catalyst materials compared to aberration-corrected STEM imaging and is beneficial for extracting information about the evolution of strain in catalyst nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

Probing Light Atoms at Subnanometer Resolution: Realization of Scanning Transmission Electron Microscope Holography

Atomic resolution imaging of light elements in electron-transparent materials has long been a challenge. Biomolecular materials, for example, are rapidly altered by incident electrons. We demonstrate a scanning transmission electron microscopy (STEM) technique, called STEM holography, capable of efficient structural analysis of beam-sensitive nanomaterials. STEM holography measures the absolute phase and amplitude of electrons passed through a specimen via interference with a vacuum reference wave. We use an amplitude-dividing nanofabricated grating to prepare multiple beams focused at the sample. We configure the postspecimen microscope imaging system to overlap the beams, forming an interference pattern. We record and analyze the pattern at each 2D-raster-scan-position, reconstructing the complex object wave. As a demonstration, we image gold nanoparticles on an amorphous carbon substrate at 2.4 Å resolution. In conclusion STEM holography offers higher contrast of the carbon while maintaining gold atomic lattice resolution compared to high angle annular dark field STEM.

4D-STEM↗

Robust Atomic-Resolution Imaging of Lithium in Battery Materials by Center-of-Mass Scanning Transmission Electron Microscopy

The performance of energy storage materials is often governed by their structure at the atomic scale. Conventional electron microscopy can provide detailed information about materials at these length scales, but direct imaging of light elements such as lithium presents a challenge. While several recent techniques allow lithium columns to be distinguished, these typically either involve complex contrast mechanisms that make image interpretation difficult or require significant expertise to perform. In this work, we demonstrate how center-of-mass scanning transmission electron microscopy (CoM-STEM) provides an enhanced ability for simultaneous imaging of lithium and heavier element columns in lithium ion conductors. Through a combination of experiments and multislice electron scattering calculations, we show that CoM-STEM is straightforward to perform and produces directly interpretable contrast for thin samples, while being more robust to variations in experimental parameters than previously demonstrated techniques. As a result, CoM-STEM is positioned to become a reliable and facile method for directly probing all elements within energy storage materials at the atomic scale.

25 ENERGY STORAGE↗

Design of Electrostatic Aberration Correctors for Scanning Transmission Electron Microscopy

Abstract In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably imperfect, introducing aberrations that limit resolution. Modern STEMs overcome this by using hardware aberration correctors comprised of many multipole elements, but these devices are complex, expensive, and can be difficult to tune. We demonstrate a design for an electrostatic phase plate that can act as an aberration corrector. The corrector is comprised of annular segments, each of which is an independent two-terminal device that can apply a constant or ramped phase shift to a portion of the electron beam. We show the improvement in image resolution using an electrostatic corrector. Engineering criteria impose that much of the beam within the probe-forming aperture be blocked by support bars, leading to large probe tails for the corrected probe that sample the specimen beyond the central lobe. We also show how this device can be used to create other STEM beam profiles such as vortex beams and probes with a high degree of phase diversity, which improve information transfer in ptychographic reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗