Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Implementing a microphysics model in hydrodynamic simulations to study the initial plasma formation in dielectric ablator materials for direct-drive implosions

A microphysics model to describe the photoionization and impact ionization processes in dielectric ablator materials like plastic has been implemented into the 1-D hydrodynamic code LILAC for planar and spherical targets. Currently, the initial plasma formation during the early stages of a laser drive are modeled in an ad hoc manner, until the formation of a critical surface. Implementation of the physics-based models predict higher values of electron density, electron temperature, and pressure than the ad hoc model. Moreover, the numerical predictions are consistent with previous experimental observations of the shinethrough mechanism in plastic ablators. For planar targets, a decompression of the rear end of the target was observed, that is similar to recent experiments. An application of this model is to understand the laser-imprint mechanism that is caused by nonuniform laser irradiation due to single beam speckle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Signatures of Radiation-Driven Double Ablation Fronts

In experiments performed with the OMEGA EP laser system, magnetic field generation in double ablation fronts was observed. Proton radiography measured the strength, spatial profile, and temporal dynamics of self-generated magnetic fields as the target material was varied between plastic (CH), aluminum, copper, and gold. Two distinct regions of magnetic field are generated in mid-Z targets -- one produced by gradients from electron thermal transport and the second from radiation-driven gradients. Extended magnetohydrodynamic simulations including radiation transport reproduced key aspects of the experiment, including field generation and double ablation front formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurement of Ice-Ablator Interface Motion for Instability Mitigation in Indirect Drive ICF Implosions

In indirect drive inertial confinement fusion (ICF) implosions hydrodynamic instability growth at the imploding capsule ablator-DT fuel interface can reduce fuel compressibility and inject ablator into the hot spot hence reducing hot spot pressure and temperature. As a mitigation strategy, a gentle acceleration of this interface is predicted by simulations and theory to significantly reduce this instability growth in the early stage of the implosion. We have performed high-contrast, time-resolved x-ray refraction enhanced radiography (RER) to accurately measure the level of acceleration as a function of the initial laser drive time history for indirect-drive implosions on the National Ignition Facility. Here, we demonstrate a transition from no acceleration to 20 ± 1.8μm ns -2 acceleration by tweaking the drive that should reduce the initial instabilities by an order of magnitude at high modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser pulse-length dependent ablation and shock generation in silicon at 5 × 10 14 W/ cm 2 intensities

The effect of laser pulse duration on energy coupling into a planar silicon target is investigated in experiments at the OMEGA-EP facility by varying the laser pulse length τ —spanning 3 orders of magnitude from 100 ps to 10 ns—while maintaining a constant peak laser intensity, I 0 = 5 × 10 14 W/ cm 2 . In theoretical models, the ablation pressure primarily scales for a given material with laser intensity and wavelength, which are all fixed variables here, allowing us to explore the specific role of laser pulse duration. Two-dimensional radiation-hydrodynamics simulations benchmarked with optical probing of the expanding plasma show that the pulse duration is critical for the ablation pressure to reach a steady state. Moreover, the pulse duration impacts shock decay and multiple wave effects, which strongly dictate the evolving shock profile that propagates within the laser-shocked target as ultimately measured by rear-surface diagnostics. The shock velocities inferred from the theoretical model, after considering shock decay, impedance matching, and shock Hugoniot, are found to be in good agreement with velocimetry measurements. However, discrepancies are observed with simulations for the shorter (0.1 ns) and longer (10 ns) pulse durations, which are respectively attributed to unaccounted contributions of kinetic absorption mechanisms and instabilities in simulations. Published by the American Physical Society 2024

Bailly-Grandvaux, M. (ORCID:0000000175294013)↗

Characterization of ablator dynamics initiated by picket-pulse conditions

Direct-drive laser-fusion targets may include low-cost plastic ablator material. Here, this work describes a tabletop experimental system designed to enable the investigation of the interaction of such ablator material as a function of the laser wavelength and the associated excitation mechanism. This experimental system offers time-resolved imaging of the material response with subpicosecond temporal resolution and ≈1-μm spatial resolution. The system involves synchronized femtosecond and picosecond lasers to initiate and characterize the dynamics of polystyrene planar targets irradiated by conditions similar to a “picket” prepulse from a direct-drive pulse shape. Ultrafast imaging of the initial excitation process followed by the resulting critical plasma formation, shock-wave propagation, and blowoff plasma expansion is used to compare the impact of excitation wavelength, 355 nm or 266 nm, on the ensuing dynamics. This work aims to investigate fundamental laser material interactions to help advance physics models that can inform the development of laser driver and target designs.

42 ENGINEERING↗

Single-shot, double-pulse determination of the detonation energy in nanosecond-laser ablation using the blast model

We demonstrate a novel single-shot method to determine the detonation energy of laser-induced plasma and investigate its performance. This approach can be used in cases where there are significant shot-to-shot variations in ablation conditions, such as laser fluctuations, target inhomogeneity, or multiple filamentation with ultrashort pulses. The Sedov blast model is used to fit two time-delayed shadowgrams measured with a double-pulse laser. We find that the reconstruction of detonation parameters is insensitive to the choice of interpulse delay in double-pulse shadowgraphy. In contrast, the initial assumption of expansion dimensionality has a large impact on the reconstructed detonation energy. The method allows for a reduction in the uncertainties of blast wave energy measurements as a diagnostic technique employed in various laser ablation applications.

42 ENGINEERING↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Method Development for Measuring U Isotope Ratios by Laser Ablation MC-ICP-MS. Task 1: Hardware Setup

The aim of this project is to develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The final methodology will ultimately be described in a detailed procedural document that will be shared with IAEA-NWAL laboratories. In this report, we describe the Task-1 deliverable; the setup and optimization of hardware required to perform U isotopic analyses by laser ablation MC-ICP-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of U Isotope Ratios by Laser Ablation MC-ICP-MS for IAEA Safeguards

This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS, that can be shared with IAEANWAL laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Analytical Method for Measuring U and Pu Particles by Laser Ablation MC-ICP-MS for the NWAL

This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS.

07 ISOTOPE AND RADIATION SOURCES↗

Developing Methodology to Determine Pu Isotopic Composition by Laser Ablation MC-ICP-MS

This project will develop methodology to analyze the Pu isotope ratio in mixed U-Pu particles by laser ablation MC-ICP-MS. This will involve: 1) testing and validation of the Pu analytical method using mixed U-Pu solutions and Pu doped glasses, 2) isotopic analysis of mixed U-Pu particles by laser ablation MC-ICP-MS, and 3) continued development of the R-based data reduction program. Details regarding the analytical method development and results of QC testing will be output as a deliverable to the IAEA, along with an updated version of the LARA data reduction software.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using radiochemistry to diagnose fuel-ablator mix in inertial confinement fusion studies at the National Ignition Facility: measurement of Tc/Mo isotopic ratios for the Pushered Single Shell campaign

The development of radiochemical measurement techniques as a diagnostic for fusion experiments at the National Ignition Facility enables a new method for assessing fuel-ablator mix and the impact of this mix on capsule performance. Diagnosing capsule mix in internal confinement fusion studies is difficult due to the small spatial scales (10s of µm) and short-time frames (100s of ps) over which the mix typically evolves in these experiments. For the Pushered Single Shell campaign, radiochemical measurements on debris collected from fusion experiments can be used to determine isotopic ratios of activation products, particularly 96g Tc/ 99 Mo and 95g Tc/ 99 Mo, to provide vital information on nuclear reactions in the burning plasma that can inform simulations that seek to understand the degree of capsule-fuel mix and the impact on the capsule performance. These radiochemical measurements have been conducted regularly since November 2023 providing data on a range of capsule designs and neutron yields. Data from eight NIF experiments is presented, the measured 96g Tc/ 99 Mo and 95g Tc/ 99 Mo range from (0.5–5) × 10 –4 to (0.3–3) × 10 –4 , respectively. The development of radiochemical diagnostics aids in understanding and optimizing the design of fusion experiments, providing unique and valuable insights into capsule behavior and directly measuring fuel-ablator mix.

and nuclear chemistry↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Methods for multiphase laser ablation analysis

Methods of liquid and solid materials analysis by laser induced ablation spectroscopy are disclosed. The liquid and solid materials are analyzed in an instrument having one pulsed laser to produce emissive plasma plumes and ablate solid material. Liquid phase samples are aerosolized before streaming to an analysis zone where they are dissociated into a plasma plume. A large number of sites within solid phase sample structures and be analyzed using a movable x-y-z stage and displayed in a chemical map.

Bol'shakov, Alexander A.↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Fast-charging lithium-ion batteries: Synergy of carbon nanotubes and laser ablation

Advancing lithium-ion battery (LiB) technology to achieve 10–15-min extreme fast charging (XFC) while maintaining high energy density and longevity poses a significant challenge. Addressing Li-plating is crucial, as it depletes useable Li, causing deterioration and safety issues. Here, this study explores a holistic approach incorporating Single-Wall Carbon Nanotubes (SWCNTs) and Laser Ablation (LA) to mitigate Li-plating while maintaining high charge acceptance under 10–15-min XFC. SWCNTs enhance the electrical conductivity and mechanical integrity of the positive electrode (PE), reducing overall cell overpotential at high charging rates. Concurrently, LA is applied to negative electrodes (NE) to reduce tortuosity of ion-diffusion pathways and increase surface wettability, improving Li-ion transport. Combining SWCNTs in the PE and LA on the NE, our experimental findings demonstrate a significant reduction in Li-plating and maintained high charge acceptance of ~84.33 % after 800 5C (12 min) charge cycles for cells having PE with ~3.3 mAh cm –2 and NE with 3.9 mAh cm –2 loadings. This study highlights the potential of combining SWCNTs and LA to address Li-plating in LiBs and opens new avenues for designing battery systems capable of achieving 10–15-min XFC.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Titanium Dioxide Nanomaterial Ink Production Through Laser Ablation Synthesis in Solution for Printed Electronics Applications

Flexible and printed electronics have become increasingly popular as they make possible the production of flexible, low-cost, multifunction devices that are unachievable through traditional manufacturing methods. The printed films are significantly impacted and thus limited by the existing ink production process. Herein, an alternate technique of generating high-quality titanium dioxide (TiO 2 ) nanoparticle ink compatible with aerosol jet printing using laser ablation synthesis in solution (LASiS) is showcased. Dynamic light scattering data and transmission electron microscopy confirm the particle size distribution. UV–vis measurements are performed, and the Beer–Lambert relationship is used to determine the concentration of the generated ink. The inks generated at two different repetition rates are compared: 200 kHz and 1 MHz. X-Ray diffraction analysis of the aerosol jet printed thin film post-thermal sintering confirms the grain size and phase purity of the printed thin films. This work demonstrates the effectiveness of the LASiS technique in producing printable nanoparticle inks with little-to-no postprocessing.

36 MATERIALS SCIENCE↗

Towards synthetic L 1 0 -FeNi: Detecting the absence of cubic symmetry in Laser-Ablated Fe-Ni nanoparticles

The L 1 0 crystal structure underlines an important class of chemically ordered alloys that exhibits uniaxial magnetocrystalline anisotropy. The near-equiatomic L 1 0 -FeNi extracted from meteorites has demonstrated intriguing magnetic properties for permanent magnet applications. However, the synthesis of this chemically ordered non-cubic structure has been a longstanding challenge. Here, in this work, we demonstrate the absence of cubic symmetry in near-equiatomic Fe-Ni nanoparticles synthesized by picosecond-pulsed laser ablation in liquids. The non-cubic phase detected in these particles can only be L 1 0 -FeNi or hexagonal close-packed (HCP) FeNi, and the absence of cubic symmetry was unequivocal. The orientation relationship between the non-cubic phase and the adjacent cubic phase was characterized by a series of transmission electron microscopy (TEM) techniques, which consistently suggests that the formation of the non-cubic phase involves a martensitic transformation process.

36 MATERIALS SCIENCE↗