Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Generalizing synthetic data-trained acoustic predictive models to real-world measurements

Acoustic Resonance Spectroscopy (ARS) is highly sensitive to structural properties such as material, geometry, and environmental conditions; as a consequence, it can noninvasively measure internal properties that are unobservable by most other methods. Because of its sensing capabilities and low implementation cost and complexity, ARS has potential as a paradigm shift in noninvasive sensing, characterization, and monitoring applications. However, extracting specific properties from ARS measurements, comprising the vibration spectrum of a test object, is challenging due to the sensitivity of the spectra to other structural changes not being measured, e.g. manufacturing tolerances, component coupling, environmental variation, etc. Neural Networks are promising tools for identifying trends in ARS measurements, but their training typically requires large datasets, which are often impractical to obtain for real-world systems. Synthetic data can be simulated efficiently, but discrepancies between synthetic and real-world data frequently lead to poor generalization when testing on the real-world data. We propose a novel ARS model training framework that enables networks trained exclusively on synthetic ARS data to generalize effectively to real-world measurements. Our approach leverages the Correlation Alignment (CORAL) technique to enforce the extraction of features common to both synthetic and real-world domains. As a case study, we demonstrate noninvasive ARS-based pressure measurements in sealed systems. Finite element method (FEM) simulations were used to generate synthetic training data across diverse vessel configurations and pressure conditions, and model performance was then tested on real-world measurements. We demonstrate that robust machine learning models for ARS can be developed without large real-world datasets, significantly broadening the applicability of ARS for noninvasive sensing. Moreover, the approach is extensible to other sensing modalities where synthetic data are abundant but real-world data are limited.

36 MATERIALS SCIENCE↗

An all fiber-optic sensor for surface acoustic wave measurements

A surface acoustic wave (SAW) sensor constructed from single-mode fiber-optic components is described. An analysis of reciprocal and nonreciprocal modes of operation of the sensor is presented. Results from measurements on a variety of SAW devices illustrate the use of the sensor. The amplitude sensitivity is 0.0003 A for an integration time of 0.1 s.

Bowers, J. E.↗

The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey quasar sample: testing observational systematics on the Baryon Acoustic Oscillation measurement

ABSTRACT Baryon Acoustic Oscillations (BAO) are considered to be a very robust standard ruler against various systematics. This premise has been tested against observational systematics, but not to the level required for the next generation of galaxy surveys such as the Dark Energy Spectroscopic Instrument (DESI) and Euclid. In this paper, we investigate the effect of observational systematics on the BAO measurement of the final sample of quasars from the extended Baryon Oscillation Spectroscopic Survey Data Release 16 in order to prepare and hone a similar analysis for upcoming surveys. We employ catalogues with various treatments of imaging systematic effects using linear and neural network-based non-linear approaches and consider how the BAO measurement changes. We also test how the variations to the BAO fitting model respond to the observational systematics. As expected, we confirm that the BAO measurements obtained from the DR16 quasar sample are robust against imaging systematics well within the statistical error, while reporting slightly modified constraints that shift the line-of-sight BAO signal by less than 1.1 per cent. We use realistic simulations with similar redshift and angular distributions as the DR16 sample to conduct statistical tests for validating the pipeline, quantifying the significance of differences, and estimating the expected bias on the BAO scale in future high-precision data sets. Although we find a marginal impact for the eBOSS QSO data, the work presented here is of vital importance for constraining the nature of dark energy with the BAO feature in the new era of big data cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Phased Acoustic Array Measurements of a 5.75 Percent Hybrid Wing Body Aircraft

Detailed acoustic measurements of the noise from the leading-edge Krueger flap of a 5.75 percent Hybrid Wing Body (HWB) aircraft model were recently acquired with a traversing phased microphone array in the AEDC NFAC (Arnold Engineering Development Complex, National Full Scale Aerodynamics Complex) 40- by 80-Foot Wind Tunnel at NASA Ames Research Center. The spatial resolution of the array was sufficient to distinguish between individual support brackets over the full-scale frequency range of 100 to 2875 Hertz. For conditions representative of landing and take-off configuration, the noise from the brackets dominated other sources near the leading edge. Inclusion of flight-like brackets for select conditions highlights the importance of including the correct number of leading-edge high-lift device brackets with sufficient scale and fidelity. These measurements will support the development of new predictive models.

Krueger noise↗

Automated acoustic intensity measurements and the effect of gear tooth profile on noise

Acoustic intensity measurements were made at NASA Lewis Research Center on a spur gear test apparatus. The measurements were obtained with the Robotic Acoustic Intensity Measurement System developed by Cleveland State University. This system provided dense spatial positioning, and was calibrated against a high quality acoustic intensity system. The measured gear noise compared gearsets having two different tooth profiles. The tests evaluated the sound field of the different gears for two speeds and three loads. The experimental results showed that gear tooth profile had a major effect on measured noise. Load and speed were found to have an effect on noise also.

Atherton, William J.↗

Automated acoustic intensity measurements and the effect of gear tooth profile on noise

Acoustic intensity measurements were made at NASA Lewis Research Center on a spur gear test apparatus. The measurements were obtained with the Robotic Acoustic Intensity Measurement System developed by Cleveland State University. This system provided dense spatial positioning, and was calibrated against a high quality acoustic intensity system. The measured gear noise compared gearsets having two different tooth profiles. The tests evaluated the sound field of the different gears for two speeds and three loads. The experimental results showed that gear tooth profile had a major effect on measured noise. Load and speed were found to have an effect on noise also.

Atherton, W. J.↗

Rotating Microphone Rake Measures Spinning Acoustic Modes

Rotating rake of pressure transducers developed for use in experimental studies of sources and propagation of noise generated by subsonic fan engines. Pressure transducers used as microphones to measure acoustic modes generated by, and spin with, fans. Versatility of control software used in rake-drive system enables measurements of acoustic modes on wide range of test-engine configurations. Rake-drive hardware easily adapted to different engines because not mechanically coupled to engine under test.

Konno, Kevin E.↗

Dynamical dark energy in light of the DESI DR2 baryonic acoustic oscillations measurements

Understanding whether cosmic acceleration arises from a cosmological constant or a dynamical component is a central goal of cosmology, and the Dark Energy Spectroscopic Instrument (DESI) enables stringent tests with high-precision distance measurements. Here we analyse measurements of baryon acoustic oscillations in DESI Data Release 1 and Data Release 2 and consider type Ia supernovae and a distance prior for the cosmic microwave background. With the larger statistical power and wider redshift coverage of Data Release 2, the preference for dynamical dark energy does not diminish relative to Data Release 1. Using both a shape-function reconstruction and non-parametric approaches with a Horndeski-motivated correlation prior, we find that the equation of state for dark energy w(z) varies with redshift. Baryon acoustic oscillation data alone yield modest constraints, but in combination with independent supernova compilations and the prior for the cosmic microwave background, they strengthen the evidence for dynamics. A Bayesian comparison of models shows moderate support for departures from Λ cold dark matter (ΛCDM) when several degrees of freedom in w(z) are allowed, corresponding to ~3σ tension with ΛCDM (and higher for some datasets). Despite methodological differences, our results are consistent with companion DESI papers, underscoring the complementarity of the approaches. Possible systematics remain under study; forthcoming DESI, Euclid and next-generation cosmic microwave background data will provide decisive tests.

cosmology↗

Dynamical dark energy in light of the DESI DR2 baryonic acoustic oscillations measurements

Understanding whether cosmic acceleration arises from a cosmological constant or a dynamical component is a central goal of cosmology, and the Dark Energy Spectroscopic Instrument (DESI) enables stringent tests with high-precision distance measurements. Here we analyse measurements of baryon acoustic oscillations in DESI Data Release 1 and Data Release 2 and consider type Ia supernovae and a distance prior for the cosmic microwave background. With the larger statistical power and wider redshift coverage of Data Release 2, the preference for dynamical dark energy does not diminish relative to Data Release 1. Using both a shape-function reconstruction and non-parametric approaches with a Horndeski-motivated correlation prior, we find that the equation of state for dark energy w(z) varies with redshift. Baryon acoustic oscillation data alone yield modest constraints, but in combination with independent supernova compilations and the prior for the cosmic microwave background, they strengthen the evidence for dynamics. A Bayesian comparison of models shows moderate support for departures from Λ cold dark matter (ΛCDM) when several degrees of freedom in w(z) are allowed, corresponding to ~3σ tension with ΛCDM (and higher for some datasets). Despite methodological differences, our results are consistent with companion DESI papers, underscoring the complementarity of the approaches. Possible systematics remain under study; forthcoming DESI, Euclid and next-generation cosmic microwave background data will provide decisive tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Measuring Acoustic-Radiation Stresses in Materials

System measures nonlinearity parameters of materials. Uses static strain generated by acoustic wave propagating in material. Since static strain is effectively "dc" component of waveform distortion, problems associated with phase-cancellation artifacts disappear. Further, sign of nonlinearity parameter obtained by simple inspection of measured signal polarity. These features make this system very amenable to use in field. System expected to become standard for acoustic-radiation-stress measurements for solids and liquids and for characterization of material properties related to strength and residual or applied stresses. Also expected to become standard for transducer calibration.

Cantrell, John H.↗

Coherence and phase techniques applied to wind tunnel acoustics

Measurements have been made of coherence and phase spectra for the acoustic field in a subsonic wind tunnel. The data are interpreted in terms of simple analytical models for propagating and diffuse noise fields, including the presence of uncorrelated noise signals. It is found that low frequency noise propagates upstream and downstream from the fan, with the noise in the test section arriving in the upstream direction. High frequency sound appears to be generated in the test section and propagates upstream and downstream. In the low frequency range, the ratio of diffuse to propagating energy is about 8 for all locations in the test section, diffuser, and settling chamber; the value of the ratio increases with frequency. Further analysis is required to describe in better detail the effects of reverberation and incoherent sources in a duct-like environment.

Wilby, J. F.↗

Acoustic Mode Measurements in the Inlet of a Model Turbofan Using a Continuously Rotating Rake

Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

Heidelberg, Laurence J.↗

Acoustic mode measurements in the inlet of a model turbofan using a continuously rotating rake

Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

Heidelberg, Laurence J.↗