An Investigation of the Icing and Heated-air De-icing Characteristics of the R-2600-13 Induction System

A laboratory investigation was made on a Holley 1685-HB carburetor mounted on an R-2600-13 supercharger assembly to determine the icing characteristics and the heated-air de-icing requirements of this portion of the B-25D airplane induction system. Icing has been found to be most prevalent at relatively small throttle openings and, consequently, all runs were made at simulated 60-percent normal rated power condition. Icing characteristics were determined during a series of 15-minute runs over a range of inlet-air conditions. For the de-icing investigation severe impact ice was allowed to form in the induction system and the time required for the recovery of 95 percent of the maximum possible air flow at the original throttle setting was then determined for a range of wet-bulb temperatures. Results of these runs showed that ice on the walls of the carburetor adapter and on the rim of the impeller-shroud portion of the supercharger diffuser plate did not affect engine operation at 60-percent normal rated power. Ice that adversely affected the air flow and the fuel-air ratio was formed only on the central web of the carburetor and then only when the inlet air was saturated or contained free moisture in excess of saturation. No serious ice formations were observed at inlet-air temperatures above 66 0 F or with an inlet-air enthalpy greater than 34 Btu per pound. The maximum temperature at. which any trace of icing could be detected was 1110 F with a relative humidity of approximately 28 percent, The air-flow recovery time for emergency de-icing was 0.3 minute for.an enthalpy of 35 Btu per pound or wet-bulb temperature of 68 0 F. Further increase in enthalpy and wet-bulb temperature above these values resulted in very slight improvement in recovery time. The fuel-air ratio restored by a 5-Minute application of heated air was approximately 7 percent less than the initial value for cold-air conditions.

Chapman, Gilbert E.↗

Preliminary studies of autoignition and flashback in a premixing-prevaporizing flame tube using Jet-A fuel at lean equivalence ratios

Lean equivalence ratios from 0.3 to 0.7 were observed. Combustor inlet air pressures were varied from 0.54 to 2.5 MPa, combustor inlet air temperatures from 550 to 700 K, and reference velocities from 8 to 35 meters per second. Autoignition delay times ranged from 15 to 100 milliseconds and varied inversely with pressure. The Arrhenius activation energy was 41,840 joules per mole. Temperature rise data were obtained in a long premixing-prevaporizing tube at a pressure of 0.56 MPa. Preflame temperature rise data were a function of equivalence ratio, inlet air temperature, and tube residence time. Significant temperature rise occurred above temperatures of 760 K, with autoignition occurring at 775 K for equivalence ratios greater than 0.47. The reactions were similar to cool-flame phenomena. Flashback velocities were measured at temperatures of 610 and 700 K, pressure of 0.56 MPa, and equivalence ratios from 0.6 to 1. Flashback velocities varied from 30 to 65 meters per second.

Marek, C. J.↗

An investigation of the internal and external aerodynamics of cattle trucks

Wind tunnel tests were conducted on a one-tenth scale model of a conventional tractor trailer livestock hauler to determine the air flow through the trailer and the drag of the vehicle. These tests were conducted with the trailer empty and with a full load of simulated cattle. Additionally, the drag was determined for six configurations, of which details for three are documented herein. These are: (1) conventional livestock trailer empty, (2) conventional trailer with smooth sides (i.e., without ventilation openings), and (3) a stream line tractor with modified livestock trailer (cab streamlining and gap fairing). The internal flow of the streamlined modification with simulated cattle was determined with two different ducting systems: a ram air inlet over the cab and NACA submerged inlets between the cab and trailer. The air flow within the conventional trailer was random and variable. The streamline vehicle with ram air inlet provided a nearly uniform air flow which could be controlled. The streamline vehicle with NACA submerged inlets provided better flow conditions than the conventional livestock trailer but not as uniform or controllable as the ram inlet configuration.

Muirhead, V. U.↗

Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

Condon, E. P.↗

Degree of vaporization using an airblast type fuel injector for a premixed-prevaporized combustor

Vaporization data are presented which could be useful in designing premixed-prevaporized fuel preparation systems for gas turbine combustors. Lean, premixed-prevaporized combustion systems are being developed because they operate with low flame temperatures and, therefore, produce low levels of nitrogen oxides. Parametric tests of the effect of inlet air temperature, length (residence time), reference velocity, pressure and fuel-air ratio on the degree of vaporization are reported. Jet A and Diesel no. 2 fuel were tested. A formula is provided which shows the effect of inlet air temperature, residence time, reference velocity, and pressure on the degree of vaporization for a constant fuel-air ratio of 0.020. The results of the effect of inlet air temperature on the degree of vaporization using Jet A and Diesel no. 2 are nearly identical.

Tacina, R. R.↗

Performance and durability of improved air-atomizing splash-cone fuel nozzles

An improved design of air-atomizing fuel nozzles was determined from a study of four differently shaped splash-cone fuel nozzles after 56 hr of durability testing in a combustor segment. Test conditions included fuel-air ratios of 0.008 to 0.018, inlet-air total pressures of 41 to 203 N/cm, inlet-air temperatures of 477 to 811 K, and a reference velocity of 21.3 m/sec. Flat-tip fuel nozzles showed the least erosion damage and at a combustor operating condition of 700 K and 101 N/sq cm an oxides-of-nitrogen emission index of 12 and a smoke number of approximately 18 with a fuel-air ratio of 0.018. Emission indices for carbon monoxide and unburned hydrocarbons were 44 and 16, respectively, at simulated idle conditions of 477 K and 41 N/sq cm.

Ingebo, R. D.↗

The effect of preheat on the structure of a swirl stabilized flame

The effect of preheat on the temperature and species distributions in propane flames stabilized on a NASA contraswirl can has been examined. Flames with compact stable structure, inner-swirler airflow of 0.0091 kg/s, outer-swirler-plus-bypass airflow of 0.0203 kg/s, and propane injected 1 mm upstream of the inner swirler hub have been selected for detailed study. Over the inlet-air-temperature range from 300 to 673 K the maximum temperature in the flame increased by 40 to 60 K per 100-K increase in inlet air temperature. The point of maximum temperature on the center line approached the exit plane as inlet air temperature was increased. Oxygen, CO, H2, and methane were found together in gas samples taken from the flame, including the regions of maximum flame temperature.

Thompson, D.↗

The Role of Design-of-Experiments in Managing Flow in Compact Air Vehicle Inlets

It is the purpose of this study to demonstrate the viability and economy of Design-of-Experiments methodologies to arrive at microscale secondary flow control array designs that maintain optimal inlet performance over a wide range of the mission variables and to explore how these statistical methods provide a better understanding of the management of flow in compact air vehicle inlets. These statistical design concepts were used to investigate the robustness properties of low unit strength micro-effector arrays. Low unit strength micro-effectors are micro-vanes set at very low angles-of-incidence with very long chord lengths. They were designed to influence the near wall inlet flow over an extended streamwise distance, and their advantage lies in low total pressure loss and high effectiveness in managing engine face distortion. The term robustness is used in this paper in the same sense as it is used in the industrial problem solving community. It refers to minimizing the effects of the hard-to-control factors that influence the development of a product or process. In Robustness Engineering, the effects of the hard-to-control factors are often called noise , and the hard-to-control factors themselves are referred to as the environmental variables or sometimes as the Taguchi noise variables. Hence Robust Optimization refers to minimizing the effects of the environmental or noise variables on the development (design) of a product or process. In the management of flow in compact inlets, the environmental or noise variables can be identified with the mission variables. Therefore this paper formulates a statistical design methodology that minimizes the impact of variations in the mission variables on inlet performance and demonstrates that these statistical design concepts can lead to simpler inlet flow management systems.

Anderson, Bernhard H.↗

Effect of increased fuel temperature on emissions of oxides of nitrogen from a gas turbine combustor burning natural gas

An annular gas turbine combustor was tested with heated natural gas fuel to determine the effect of increasing fuel temperature on the formation of oxides of nitrogen. Fuel temperatures ranged from ambient to 800 K (980 F). Combustor pressure was 6 atmospheres and the inlet air temperature ranged from 589 to 894 K (600 to 1150 F). The NOx emission index increased with fuel temperature at a rate of 4 to 9 percent per 100 K (180 F), depending on the inlet air temperature. The rate of increase in NOx was lowest at the highest inlet air temperature tested.

Marchionna, N. R.↗

High-Speed Cascade Tests of the NACA 65-(12A(sub 10))10 and NACA 65-(12A(sub 2)I(sub 8b))10 Compressor Blade Sections

Two-dimensional porous-well cascade tests of the NACA 65- (l2Al0) 10 and NACA 65-(l2A2I8b)10 blade sections were made at Mach numbers from 0.3 to choking in most cases. Data were obtained at solidities of 1.0 and 1.5 et inlet-air angles of 45 deg. and 60 deg. for both blade sections. With a solid--wall modification to the cascade tunnel, schlieren observations were made of the flow in cascade at a solidity of 1.5 and inlet-air angle of 45 deg. and at a solidity of 1.0 and inlet-air angle of 60 deg. Test results for the NACA 65-(12A10)l0 blade section show t hat the turning angles measured at low speed do not change significantly as the speed increases until the critical Mach number is exceed. Because of increasing separation from the highly cambered trailing-edge region, the turning angles for the NACA 65-(12A2I8b)10 blade section decreased as much as 4 deg. from low speed to critical speed. The high-speed performance of the NACA 65-(12A10)10 and the NACA 65-(12A2I8b)l0 blade sections is largely determined by the passage area distribution. The angle of attack for best operation at high Mach numbers is higher than the design angle of attack selected at low speed to have pressure distributions that are free of peaks.

Dunavant, James C.↗

Flame radiation and liner heat transfer in a tubular-can combustor

Heat transfer within a combuster were examined. Total and spectral flame radiation in a tubular can combustor at a series of parametric operating conditions was measured. Radiation measurements were taken for a range of inlet air pressures from 0.34 to 2.0 MPa, inlet air temperatures from 533 to 700 K, with two different fuels, Jet-A and ERBS. Measurements of liner temperatures combined with the parametric radiation results allowed a calculation of the combustor liner heat loads. Flame emissivity was determined from the spectral measurements.

Claus, R. W.↗

Flame radiation and linear heat transfer in a tubular can combustor

Heat transfer within a combuster were examined. Total and spectral flame radiation in a tubular can combustor at a series of parameteric operating conditions was measured. Radiation measurements were taken for a range of inlet air pressures from 0.34 to 2.0 MPa, inlet air temperatures from 533 to 700 K, with two different fuels, Jet-A and ERBS. Measurements of linear temperatures combined with the parametric radiation results allowed a calculation of the combustor linear heat loads. Flame emissivity was determined from the spectral measurements. Previously announced in STAR as N84-13188

Claus, R. W.↗

Combustion Dynamics Characteristics and Fuel Pressure Modulation Responses of a Three-Cup Third-Generation Swirl-Venturi Lean Direct Injection Combustion Concept

This paper presents the combustion dynamic data and fuel modulation response of a three-cup Lean Direct Injection combustor developed by Woodward, FST. The test was conducted at the NASA Glenn Research Center CE-5 flame tube test facility. The facility provided inlet air up to 922 K and pressure up to 19.0 bar. At the low-power configuration, the combustion noise was quiet. Large combustion pressure oscillations were observed with the High-power configuration at an off design condition, with low inlet air temperature and pressure conditions and a high equivalence ratio (about T3=600 K, P3 = 800 kPa, and ER =0.46). The noise amplitude was as high as 1.5 psi at around 220 Hz. As inlet air pressure and temperature increased, this combustion instability decreased. Fuel modulated signals were produced with the WASK fuel modulator located in the fuel line upstream of the center cup pilot fuel-air mixer. The amplitudes of the modulated signals detected in the combustor were low. Only less than 0.13% (0.06 psi) of the input energy was detected, and the signal amplitudes decreased as the modulated frequencies increased. Interaction between the modulated signals and the combustion noise varied with operating conditions. At a condition with low combustion noise around 150 hz, modulating a signal at around the same frequency would increase the combustion noise from 0.2 psi to as high as 0.6 psi, whereas at a condition with a high combustion instability around 250 hz, the modulated signal did not seem to have much effect on the combustion noise.

Fuel flexible combustor↗

Spontaneous ignition temperature limits of jet A fuel in research-combustor segment

The effects of inlet-air pressure and reference velocity on the spontaneous-ignition temperature limits of Jet A fuel were determined in a combustor segment with a primary-zone length of 0.076 m (3 in.). At a constant reference velocity of 21.4 m/sec (170 ft/sec), increasing the inlet-air pressure from 21 to 207 N/sq cm decreased the spontaneous-ignition temperature limit from approximately 700 to 555 K. At a constant inlet-air pressure of 41 N/sq cm, increasing the reference velocity from 12.2 to 30.5 m/sec increased the spontaneous-ignition temperature limit from approximately 575 to 800 K. Results are compared with other data in the literature.

Ingebo, R. D.↗

Knock-Limited Performance of Triptane and 28-R Fuel Blends as Affected by Changes in Compression Ratio and in Engine Operating Variables

A knock-limited performance investigation was conducted on blends of triptane and 28-P fuel with a 12-cylinder, V-type, liquid-cooled aircraft engine of 1710-cubic-inch displacement at three compression ratios: 6.65, 7.93, and 9.68. At each compression ratio, the effect of changes in temperature of the inlet air to the auxiliary-stage supercharger and in fuel-air ratio were investigated at engine speeds of 2280 and. 3000 rpm. The results show that knock-limited engine performance, as improved by the use of triptane, allowed operation at both take-off and cruising power at a compression ratio of 9.68. At an inlet-air temperature of 60 deg F, an engine speed of 3000 rpm ; and a fuel-air ratio of 0,095 (approximately take-off conditions), a knock-limited engine output of 1500 brake horsepower was possible with 100-percent 28-R fuel at a compression ratio of 6.65; 20-percent triptane was required for the same power output at a compression ratio of 7.93, and 75 percent at a compression ratio of 9.68 allowed an output of 1480 brake horsepower. Knock-limited power output was more sensitive to changes in fuel-air ratio as the engine speed was increased from 2280 to 3000 rpm, as the compression ratio is raised from 6.65 to 9.68, or as the inlet-air temperature is raised from 0 deg to 120 deg F.

Brun, Rinaldo J.↗

Atomizing characteristics of swirl can combustor modules with swirl blast fuel injectors

Cold flow atomization tests of several different designs of swirl can combustor modules were conducted in a 7.6 cm diameter duct at airflow rates (per unit area) of 7.3 to 25.7 g/sq cm sec and water flow rates of 6.3 to 18.9 g/sec. The effect of air and water flow rates on the mean drop size of water sprays produced with the swirl blast fuel injectors were determined. Also, from these data it was possible to determine the effect of design modifications on the atomizing performance of various fuel injector and air swirler configurations. The trend in atomizing performance, as based on the mean drop size, was then compared with the trends in the production of nitrogen oxides obtained in combustion studues with the same swirl can combustors. It was found that the fuel injector design that gave the best combustor performance in terms of a low NOx emission index also gave the best atomizing performance as characterized by a spray of relatively small mean drop diameter. It was also demonstrated that at constant inlet air stream momentum the nitrogen oxides emission index was found to vary inversely with the square of the mean drop diameter of the spray produced by the different swirl blast fuel injectors. Test conditions were inlet air static pressures of 100,000 to 200,000 N/sq m at an inlet air temperature of 293 K.

Ingebo, R. D.↗