At least 127 records · Page 7

Nonlinear control of the minimum safety factor in tokamaks by optimal allocation of spatially moving electron cyclotron current drive

The minimum value of the safety factor profile is related to the magnetohydrodynamic (MHD) stability of the plasma confined in a tokamak. Therefore, active control of the minimum safety factor may mitigate MHD instabilities that can degrade or even terminate plasma confinement. Typically, in most tokamak scenarios, the minimum safety factor evolves spatially with time, i.e., the location at which the safety factor achieves the minimum value changes with time. In addition to the inherent nonlinearities in the minimum safety factor evolution, its spatial variation makes the control design challenging. In particular, complexity in control design may arise from the need for time-dependent nonlinear models that account for spatial variation of the minimum safety factor. Furthermore, the minimum safety factor may drift to locations where the actuator authority is low. The problem of minimum safety factor control with target location tracking and moving electron cyclotron current drive (ECCD) is addressed in this work. A nonlinear time-dependent model that incorporates the spatial variation of the minimum safety factor is presented. A nonlinear controller based on optimal feedback linearization is developed to track a target minimum safety factor. The proposed controller treats the ECCD position as a controllable variable. In other words, the controller prescribes the ECCD position (in addition to the non-inductive powers) in real time based on an optimal criterion that is defined a priori. This work also presents the steps necessary to integrate the minimum safety factor controller with a total energy controller to achieve multiple control objectives simultaneously. In conclusion, the proposed integrated control algorithm is tested using nonlinear simulations in the Control Oriented Transport SIMulator (COTSIM) for a DIII-D tokamak scenario.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Allocation of Proton Therapy Slots in Combined Proton-Photon Radiation Therapy

Proton therapy is a limited resource that is not available to all patients who may benefit from it. We investigated combined proton-photon treatments, in which some fractions are delivered with protons and the remaining fractions with photons, as an approach to maximize the benefit of limited proton therapy resources at a population level.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Valued peaks: Sustainable water allocation for small hydropower plants in an era of explicit ecological needs

Optimizing hydropower operations to balance economic profitability and support functioning ecosystem services is integral to river management policy. In this article, we propose a dynamic, constrained optimization framework for small hydropower plants (SHPs) to evaluate trade-offs between economic profitability and socio-ecological requirements. Specifically, we examine the balance between short-term losses in hydropower generation and the potential for compensatory benefits in the form of revenue from recreational ecosystem services, irrespective of the direct beneficiary. Our framework integrates a fish habitat model, a hydropower optimization model, and a recreational ecosystem service estimate to evaluate different environmental flow scenarios. The optimization process gives three outflow release scenarios, informed by previous streamflow realisations (dam inflow), and designed environmental flow constraints. The framework is applied and tested for the river Kuusinkijoki in North-eastern Finland, which is a habitat for migratory brown trout and grayling populations. We show that the revenue loss due to the environmental flow constraints arises through a reduction in revenue per generated energy unit and through a reduction in turbine efficiency. Additionally, the simulation results reveal that all the designed environmental flow constraints cannot be met simultaneously. Under the environmental flow scenario with both minimum flow and flow ramping rate constraints, the annual hydropower revenue decreases by 16.5 %. An annual increase of 8 % in recreational fishing visits offsets the revenue loss. In conclusion, the developed framework provides knowledge of the costs and benefits of hydropower environmental flow constraints and guides the prioritizing process of environmental measures.

13 HYDRO ENERGY↗

Belowground allocation and dynamics of recently fixed plant carbon in a California annual grassland

Plant roots and the organisms that surround them are a primary source for stabilized soil organic carbon (SOC). While grassland soils have a large capacity to store organic carbon (C), few field-based studies have quantified the amount of plant-fixed C that moves into soil and persists belowground over multiple years. Yet this characteristic of the soil C cycle is critical to C storage, soil water holding capacity, nutrient provisions, and the management of soil health. Here, we tracked the fate of plant-fixed C following a five-day 13 CO 2 labeling of a Northern California annual grassland, measuring C pools starting at the end of the labeling period, at three days, four weeks, six months, one year, and two years. Soil organic carbon was fractionated using a density-based approach to separate the free-light fraction (FLF), occluded-light fraction (OLF), and heavy fraction (HF). Using isotope ratio mass spectrometry, we measured 13 C enrichment and total C content for plant shoots, roots, soil, soil dissolved organic carbon (DOC), and the FLF, OLF, and HF. The chemical nature of C in the HF was further analyzed by solid state 13 C nuclear magnetic resonance (NMR) spectroscopy.

13C-NMR↗

Allocation and Operation of A Hydropneumatic Energy Storage with Building Microgrid

Behind-meter application for a recently invented hydropneumatic Ground-Level Integrated Diverse Energy Storage (GLIDES) is focused in this research. Considering possible uncertainties from solar radiation and electricity load in a building microgrid, two-stage stochastic programming is adopted for 15-min operation and a mixed-integer nonlinear stochastic model is built with integrated energy systems of GLIDES, solar panel and power generating unit. In order to make the model computationally tractable, we use sample average approximate method to decrease associated complexity with sample size and improve solving efficiency. The experimental results in deterministic and stochastic operation indicate that best candidate solution from SAA are superior to the solution from expected value problem in terms of optimality gap and variance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗