Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerated beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Collimated Propagation of Fast Electron Beams Accelerated by High-Contrast Laser Pulses in Highly Resistive Shocked Carbon

In this study, collimated transport of ultrahigh intensity electron current was observed in cold and in laser-shocked vitreous carbon, in agreement with simulation predictions. The fast electron beams were created by coupling high-intensity and high-contrast laser pulses onto copper-coated cones drilled into the carbon samples. The guiding mechanism—observed only for times before the shock breakout at the inner cone tip—is due to self-generated resistive magnetic fields of ~ 0.5–1 kT arising from the intense currents of fast electrons in vitreous carbon, by virtue of its specific high resistivity over the range of explored background temperatures. The spatial distribution of the electron beams, injected through the samples at different stages of compression, was characterized by side-on imaging of hard x-ray fluorescence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BEAM ACCELERATION BY A MULTICELL RF CAVITY STRUCTURE PROPOSED FOR AN IMPROVED YIELD IN HYDROFORMING

We study the accelerating properties of a new multicell cavity structure with irises forming a rectangular aperture between the cavity cells. We are interested in this structure because, from a mechanical point of view, it may be possible to manufacture with high quality using a hydroforming process. RF analysis shows that the rectangular iris shape provides some asymmetric transverse focusing per half RF period, particularly for low beam energies. If the horizontal and vertical rectangular irises are interleaved, the net transverse focusing could be increased. Here we present studies of the acceleration and transport properties of these cavities by tracking particles using the ORBIT Code through time-dependent 3D cavity fields taken from CST MWS.

43 PARTICLE ACCELERATORS↗

Particle Rate and Host Accelerator Beam Loss on the MICE Experiment

A study is presented of particle rates in the MICE Muon Beamline and their relationship to beam loss produced in ISIS. A brief overview of neutrino physics is presented, together with a discussion on the Neutrino Factory as a motivation for MICE. An overview of MICE itself is then presented, highlighting the need for a systematic understanding of the relationship between the MICE target parameters, ISIS beam loss, and MICE particle rate. The variation of beam loss with target depth is examined and observed to be non-linear. The variation of beam loss with respect to the target dip time in the ISIS cycle is examined and observed to be approximately linear for dip times between 11.1 ms and 12.6 ms after ISIS injection, before tailing at earlier dip times. The variation of beam loss with particle rate is also observed to follow an approximately linear relationship from 0.05 V.ms to 4.7 V.ms beam loss, with a further strong indication that this continues up to 7.1 V.ms. Particle identification using time-of-flight data is used to give an insight into the relative abundances of each particle species present in the MICE beam. Estimates of muon rate are then produced as a function of beam loss. At a level of 2 V.ms beam loss ~10.9 muons per spill for a 3.2 ms spill with negative π → μ optics, and ~31.1 muons per 1 ms spill with positive π → μ optics are observed. Simulations using the ORBIT particle tracking code of the beam loss distributions around the ISIS ring, caused by the MICE target, are also presented and the implications for MICE running discussed.

43 PARTICLE ACCELERATORS↗

Experimental Measurements of the Secondary Electron Yield in the Experimental Measurement of the Secondary Electron Yield in the PEP-II Particle Accelerator Beam Line

Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders (LC) such as ILC and CLIC. To test a series of promising possible electron cloud mitigation techniques as surface coatings and grooves, in the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed several test vacuum chambers including (i) a special chamber to monitor the variation of the secondary electron yield of technical surface materials and coatings under the effect of ion, electron and photon conditioning in situ in the beam line; (ii) chambers with grooves in a straight magnetic-free section; and (iii) coated chambers in a dedicated newly installed 4-magnet chicane to study mitigations in a magnetic field region. In this paper, we describe the ongoing R&D effort to mitigate the electron cloud effect for the LC damping ring, focusing on the first experimental area and on results of the reduction of the secondary electron yield due to in situ conditioning.

43 PARTICLE ACCELERATORS↗

Secondary particle production from laser accelerated beams

3-MeV protons and fusion neutrons are generated by focused radiation of the 3-TW Prague Asterix Laser System (PALS). 30-mA current of 3-MeV protons is detected behind the target in the forward direction when a hydrogenated silicon foil is used. The co-occurrence of bursts in the emission of ions and fusion neutrons from CD{sub 2} plasma is observed. The energy of produced deuteron bursts is high enough to drive deuterium fusion in CD{sub 2} catcher targets.

43 PARTICLE ACCELERATORS↗

Experimental characterisation of charged particle beams accelerated by irradiating thin targets of different materials with ultrashort laser pulses

We present the results of experimental investigation of ion and electron fluxes produced by irradiating thin foils with laser USPs. These experiments were carried out on the Sokol-P laser facility (pulse duration {approx}1 ps, power {approx}20 TW) using lavsan, aluminium, and copper targets of equal thickness ({approx}5 {mu}m). Ions were recorded employing Thomson spectrometers and a time-of-flight spectrometer with a silicon semiconductor detector. To record electrons, use was made of electron spectrometers involving the rotation of particle trajectories by 180{sup 0} in magnetic field. The ionic composition of the charged particle beam was determined and the beam shape was investigated in relation to the target material. (effects of laser radiation on matter)

36 MATERIALS SCIENCE↗

Early Side Effects of Three-Dimensional Conformal External Beam Accelerated Partial Breast Irradiation to a Total Dose of 40 Gy in One Week (A Phase II Trial)

Purpose: Several accelerated partial breast irradiation (APBI) techniques are described in the literature, and apparently, the three-dimensional (3D)-conformal technique is being used increasingly. Nonetheless, the optimal radiation dose is not yet known. Here, we report feasibility and early toxicities of APBI delivering 40 Gy over 5 days, in a phase II trial. Methods and Materials: From October 2007 to September 2008, 25 patients with pT1N0 cancer received 3D-conformal APBI. The prescribed radiation dose was 40 Gy in 4-Gy fractions given twice daily. This technique used two minitangents and an 'en face' electron field. Toxicities were systematically assessed at 1, 2, and 6 months and then once every 6 months. Results: The planning tumor volume for evaluation (PTV{sub E}VAL) coverage was adequate: the mean dose to the PTV{sub E}VAL was 41.8 Gy (range, 41-42.4 Gy). Mean doses to the ipsilateral lung and heart were 1.6 Gy (range, 1.0-2.3 Gy) and 1.2 Gy (range, 1.0-1.6 Gy), respectively. One and two months after completion of APBI, most patients had no or mild erythema (n = 16 patients at 1 month; n = 25 patients at 2 months); none of these patients developed moist desquamation. After a median follow-up of 12 months, only 1 patient had a significant moderate field contracture (grade 2). Other reported late toxicities were grade 1. Conclusions: 3D-conformal APBI (with two minitangents and an 'en face' electron field) using a total dose of 40 Gy in 10 fractions twice daily over 5 days achieved appropriate PTV{sub E}VAL coverage and offered significant sparing of normal tissue. Early tolerance was excellent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗