Accelerated thermal aging of harvested hypalon jacket for remaining useful life determination and diagnosis - 210

For nuclear power plants (NPPs) considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80 deg. C and 120 deg. C was carried out on a multi-conductor control rod cable that had been inservice for over 30 years and was made by Boston Insulated Wire with Hypalon{sup TM} cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45 deg. C, was estimated to be 80 years. These values were slightly below previous measurements on similar BIW Hypalon cable jacket and could either be attributed to inservice degradation or variations in material properties from process variations. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance and control study of a low-pressure-ratio turbojet engine for a drone aircraft

The results of analog and digital computer studies of a low-pressure-ratio turbojet engine system for use in a drone vehicle are presented. The turbojet engine consists of a four-stage axial compressor, single-stage turbine, and a fixed area exhaust nozzle. Three simplified fuel schedules and a generalized parameter fuel control for the engine system are presented and evaluated. The evaluation is based on the performance of each schedule or control during engine acceleration from a windmill start at Mach 0.8 and 6100 meters to 100 percent corrected speed. It was found that, because of the higher acceleration margin permitted by the control, the generalized parameter control exhibited the best dynamic performance.

Seldner, K.↗

Status and Plans for a Superconducting RF Accelerator Test Facility at Fermilab

The Advanced Superconducting Test Accelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750 MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

43 PARTICLE ACCELERATORS↗

805 MHz Beta = 0.47 Elliptical Accelerating Structure R & D

A 6-cell 805 MHz superconducting cavity for acceleration in the velocity range of about 0.4 to 0.53 times the speed of light was designed. After single-cell prototyping, three 6-cell niobium cavities were fabricated. In vertical RF tests of the 6-cell cavities, the measured quality factors (Q{sub 0}) were between 7 {center_dot} 10{sup 9} and 1.4 {center_dot} 10{sup 10} at the design field (accelerating gradient of 8 to 10 MV/m). A rectangular cryomodule was designed to house 4 cavities per cryomodule. The 4-cavity cryomodule could be used for acceleration of ions in a linear accelerator, with focusing elements between the cryomodules. A prototype cryomodule was fabricated to test 2 cavities under realistic operating conditions. Two of the 6-cell cavities were equipped with helium tanks, tuners, and input coupler and installed into the cryomodule. The prototype cryomodule was used to verify alignment, electromagnetic performance, frequency tuning, cryogenic performance, low-level RF control, and control of microphonics.

43 PARTICLE ACCELERATORS↗

Advancing Conduction-Cooled 650 MHz SRF Technology for Industrial Accelerators at Fermilab's IARC

The National Nuclear Security Administration (NNSA) funds the Illinois Accelerator Research Center (IARC) at Fermilab in developing a high-power, conduction-cooled Superconducting Radio Frequency (SRF) accelerator tailored for industrial applications requiring robust and efficient operation. A 650 MHz, 1.6 MeV, 20 kW SRF accelerator is currently under development, employing a conduction cooling approach to simplify cryogenic requirements and enhance accessibility for industrial use. The accelerator’s control system is implemented on the Blinky Lite platform, selected for its open-source architecture, secure remote access capabilities, and operational flexibility—attributes advantageous for industrial deployment and sustained operation. A dedicated beamline is designed to measure essential beam parameters and test the integrated performance of the accelerator and control systems, thereby validating their operational readiness for intended applications

Ji, Y. [Fermilab] (ORCID:0000000233981752)↗

Collaboration for Advanced Modeling of Particle Accelerators

The pverarching purpose is to accelerate and expand the scope of discoveries from high energy physics (HEP) particle accelerators by enabling the design of accelerators that are significantly more compact and cheaper to build and run. This will be realized through (i) developing high-performance computing (HPC) accelerator and beam modeling capabilities to design the full range of systems required (ii) developing community simulation ecosystems that seamlessly integrate accelerator elements to facilitate the design and control of next-generation accelerators.

43 PARTICLE ACCELERATORS↗

A Study of Fixed-Order Mixed Norm Designs for a Benchmark Problem in Structural Control

This study investigates the use of H2, p-synthesis, and mixed H2/mu methods to construct full-order controllers and optimized controllers of fixed dimensions. The benchmark problem definition is first extended to include uncertainty within the controller bandwidth in the form of parametric uncertainty representative of uncertainty in the natural frequencies of the design model. The sensitivity of H2 design to unmodelled dynamics and parametric uncertainty is evaluated for a range of controller levels of authority. Next, mu-synthesis methods are applied to design full-order compensators that are robust to both unmodelled dynamics and to parametric uncertainty. Finally, a set of mixed H2/mu compensators are designed which are optimized for a fixed compensator dimension. These mixed norm designs recover the H, design performance levels while providing the same levels of robust stability as the u designs. It is shown that designing with the mixed norm approach permits higher levels of controller authority for which the H, designs are destabilizing. The benchmark problem is that of an active tendon system. The controller designs are all based on the use of acceleration feedback.

Whorton, Mark S.↗

Chaotic Advection and Unsteady Flow in Groundwater Remediation - 17237

This paper reviews an ongoing research program of numerical and laboratory studies on chaotic advection applied to groundwater remediation, including numerically simulated effects of sorption and heterogeneity, and experiments aimed at demonstrating chaotic advection in refractive index matched (i.e., transparent) porous media. Additionally, this paper outlines a proposed approach to test chaotic advection at an appropriate field site. If shown to be successful in a field application, chaotic advection offers the possibility of better hydraulic control of contaminant plumes, accelerated remediation, consequent reduction in cost, and improvement in environmental health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-FG-201-05: Varian MPC as a Statistical Process Control Tool

Purpose: Quality assurance in radiotherapy requires the measurement of various machine parameters to ensure they remain within permitted values over time. In Truebeam release 2.0 the Machine Performance Check (MPC) was released allowing beam output and machine axis movements to be assessed in a single test. We aim to evaluate the Varian Machine Performance Check (MPC) as a tool for Statistical Process Control (SPC). Methods: Varian’s MPC tool was used on three Truebeam and one EDGE linac for a period of approximately one year. MPC was commissioned against independent systems. After this period the data were reviewed to determine whether or not the MPC was useful as a process control tool. Analyses on individual tests were analysed using Shewhart control plots, using Matlab for analysis. Principal component analysis was used to determine if a multivariate model was of any benefit in analysing the data. Results: Control charts were found to be useful to detect beam output changes, worn T-nuts and jaw calibration issues. Upper and lower control limits were defined at the 95% level. Multivariate SPC was performed using Principal Component Analysis. We found little evidence of clustering beyond that which might be naively expected such as beam uniformity and beam output. Whilst this makes multivariate analysis of little use it suggests that each test is giving independent information. Conclusion: The variety of independent parameters tested in MPC makes it a sensitive tool for routine machine QA. We have determined that using control charts in our QA programme would rapidly detect changes in machine performance. The use of control charts allows large quantities of tests to be performed on all linacs without visual inspection of all results. The use of control limits alerts users when data are inconsistent with previous measurements before they become out of specification. A. Carver has received a speaker’s honorarium from Varian.

07 ISOTOPE AND RADIATION SOURCES↗

Real-Time Dosimetry for Radiobiology Experiments Using 25 MeV LINAC

The next generation of radiobiology research requires increasingly more complex radiation sources to address questions ranging from the effects of space-based radiation to the influence of dose rate on biological systems. The Idaho Accelerator Center (IAC) has developed a radiobiology research facility to address some of these questions. The irradiation challenge is to deliver stable and reproducible conditions of high dose rate with well-controlled beam uniformity, dose, and dose rate under controlled temperature. In this work, we used a 25 MeV modified medical grade linear accelerator (LINAC) to obtain a high and adjustable electron dose rate. To overcome electron beam drift we used a collimator that both assisted the LINAC operator to steer the beam and ensured that regardless of beam drift, only the fixed collimated beam would irradiate the specimens. In addition, we utilized a beam flattener to keep the beam variation as low as 3% at 2.5 cm from the beam's center, and 1% variation between the simultaneously irradiated sample tubes. We also demonstrated that a segmented Faraday 'cup'(FC) array provides a useful real-time beam scanning and monitoring system, and is promising for implementing real-time dosimetry and control.

43 PARTICLE ACCELERATORS↗

JBluIce-EPICS control system for macromolecular crystallography.

The trio of macromolecular crystallography beamlines constructed by the General Medicine and Cancer Institutes Collaborative Access Team (GM/CA-CAT) in Sector 23 of the Advanced Photon Source (APS) have been in growing demand owing to their outstanding beam quality and capacity to measure data from crystals of only a few micrometres in size. To take full advantage of the state-of-the-art mechanical and optical design of these beamlines, a significant effort has been devoted to designing fast, convenient, intuitive and robust beamline controls that could easily accommodate new beamline developments. The GM/CA-CAT beamline controls are based on the power of EPICS for distributed hardware control, the rich Java graphical user interface of Eclipse RCP and the task-oriented philosophy as well as the look and feel of the successful SSRL BluIce graphical user interface for crystallography. These beamline controls feature a minimum number of software layers, the wide use of plug-ins that can be written in any language and unified motion controls that allow on-the-fly scanning and optimization of any beamline component. This paper describes the ways in which BluIce was combined with EPICS and converted into the Java-based JBluIce, discusses the solutions aimed at streamlining and speeding up operations and gives an overview of the tools that are provided by this new open-source control system for facilitating crystallographic experiments, especially in the field of microcrystallography.

43 PARTICLE ACCELERATORS↗

Further developments in generating type-safe messaging

At ICALEPCS 09, we introduced a source code generator that allows processes to communicate safely using data types native to each host language. In this paper, we discuss further development that has occurred since the conference in Kobe, Japan, including the addition of three more client languages, an optimization in network packet size and the addition of a new protocol data type. The protocol compiler is continuing to prove itself as an easy and robust way to get applications written in different languages hosted on different computer architectures to communicate. We have two active Erlang projects that are using the protocol compiler to access ACNET data at high data rates. We also used the protocol compiler output to deliver ACNET data to an iPhone/iPad application. Since it takes an average of two weeks to support a new language, we're willing to expand the protocol compiler to support new languages that our community uses.

43 PARTICLE ACCELERATORS↗