Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Features”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced antireflection for back-illuminated silicon photomultipliers to detect faint light

Silicon photomultipliers have attracted increasing attention for detecting low-density light in both scientific research and practical applications in recent years; yet the photon losses due to reflection on the light-sensitive planar silicon surface considerably limit its photon detection efficiency. Here we demonstrate an advanced light trapping feature by developing the multi-layer antireflection coatings and the textured silicon surface with upright random nano-micro pyramids, which significantly reduces the reflection of faint light in a wide spectrum, from ultraviolet to infrared. Integrating this advanced photon confinement feature into next-generation back-illuminated silicon photomultiplier would increase the photon detection efficiency with significantly lower reflection and much more active areas. This advanced design feature offers the back-illuminated silicon photomultiplier broader application opportunities exemplified in the emerging scenarios such as nuclear medical imaging, light detection and ranging for autonomous driving, detection of scintillation light in ionizing radiation, as well as high energy physics.

42 ENGINEERING↗

The effect of support functions in a computerized procedure system on interface management tasks - 235

By adapting digital and computer technology, the design of main control rooms (MCR) in nuclear power plants has been changed. When operators operate a nuclear power plant, the tasks using soft controls in advanced MCRs include primary tasks and secondary tasks. Primary tasks are to control nuclear power plant devices and secondary tasks are to find appropriate screens or devices by screen navigations and selections before performing the primary task. The secondary task including interface management tasks is newly introduced in advanced MCRs. In this paper, the tasks are analyzed based on the simulation data of APR1400 which is one of the digitalized nuclear power plants. For analyzing tasks, the unit tasks are divided into three types: navigation, manipulation, and acknowledgement. The primary task represents the manipulation of devices and the secondary task indicates the navigating screens, opening control panels, closing control panels, and confirming the acknowledging alarms. To analyze the effect of support functions of a computerized procedure system (CPS), one of the functions which is expected to have a significant effect on the secondary tasks was considered, that is 'related screen link button.' Two factors, 'ratio of screen alteration' and 'ratio of using screen link button', were used to see the effect of 'related screen link button'. From the task analysis result, it was observed that the secondary tasks which is one of the unique features in advanced MCRs have a quite much portion than that of the primary tasks. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-02: An MRI Simulator From Proposal to Operation

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

High Metal Removal Rate Process for Machining Difficult Materials

Machining methods across many industries generally require multiple operations to machine and process advanced materials, features with micron precision, and complex shapes. The resulting multiple machining platforms can significantly affect manufacturing cycle time and the precision of the final parts, with a resultant increase in cost and energy consumption. Ultrafast lasers represent a transformative and disruptive technology that removes material with micron precision and in a single step manufacturing process. Such precision results from athermal ablation without modification or damage to the remaining material which is the key differentiator between ultrafast laser technologies and traditional laser technologies or mechanical processes. Athermal ablation without modification or damage to the material eliminates post-processing or multiple manufacturing steps. Combined with the appropriate technology to control the motion of the work piece, ultrafast lasers are excellent candidates to provide breakthrough machining capability for difficult-to-machine materials. At the project onset in early 2012, the project team recognized that substantial effort was necessary to improve the application of ultrafast laser and precise motion control technologies (for micromachining difficult-to-machine materials) to further the aggregate throughput and yield improvements over conventional machining methods. The project described in this report advanced these leading-edge technologies thru the development and verification of two platforms: a hybrid enhanced laser chassis and a multi-application testbed.

42 ENGINEERING↗

Thermal enhancement cartridge heater modified tritium hydride bed development, Part 2 - Experimental validation of key conceptual design features

The Thermal Enhancement Cartridge Heater Modified (TECH Mod) tritium hydride bed is an interim replacement for the first generation (Gen1) process hydride beds currently in service in the Savannah River Site (SRS) Tritium Facilities. 3 new features are implemented in the TECH Mod hydride bed prototype: internal electric cartridge heaters, porous divider plates, and copper foam discs. These modifications will enhance bed performance and reduce costs by improving bed activation and installation processes, in-bed accountability measurements, end-of-life bed removal, and He-3 recovery. A full-scale hydride bed test station was constructed at the Savannah River National Laboratory (SRNL) in order to evaluate the performance of the prototype TECH Mod hydride bed. Controlled hydrogen (H{sub 2}) absorption/ desorption experiments were conducted to validate that the conceptual design changes have no adverse effects on the gas transfer kinetics or H{sub 2} storage/release properties compared to those of the Gen1 bed. Inert gas expansions before, during, and after H{sub 2} flow tests were used to monitor changes in gas transfer rates with repeated hydriding/de-hydriding of the hydride material. The gas flow rates significantly decreased after initial hydriding of the material; however, minimal changes were observed after repeated cycling. The data presented herein confirm that the TECH Mod hydride bed would be a suitable replacement for the Gen1 bed with the added enhancements expected from the advanced design features. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced nanoscale characterization of aluminum nanoparticles with modified surface morphology via atmospheric helium and carbon monoxide plasmas

Aluminum nanoparticles (nAl) have the potential as energetic additives in explosive/propellant formulations. Scalable methodologies must be pursued to mitigate the inactive amorphous alumina shell surrounding the active aluminum (Al) core with modified surface morphology and chemistry for increased combustion effects. This work explores the feasibility of making reactive core/shell nAl with thinned oxide shells and modified surface coatings via a two-step atmospheric plasma surface treatment process in a custom dielectric barrier discharge plasma reactor. The commercial nAl of nominal average size similar to 40-60nm was first treated with helium (He) followed by He/carbon monoxide (CO) plasmas for different durations. The resultant samples were characterized via high-resolution transmission electron microscopy (HRTEM) and Fourier transform IR (FTIR) spectra. HRTEM images revealed sporadic patchy gamma -alumina deposits on particle surfaces and in gaps among particles for all samples, suggesting the non-uniform plasma effects of the He/CO glow. Nanoscale chemical analyses via scanning transmission electron microscopy elemental mapping and x-ray energy dispersive spectroscopy were further performed. Although no carbon-associated structure appeared in electron energy loss spectroscopy (EELS) spectra, the presence of carbonaceous materials was confirmed as a thin dispersive layer evenly distributed on the nAl surface suggesting either its amorphous nature or is present at a level insufficient to generate satisfactory EELS spectra. The trend of intensity profiles for key elements acquired by drawing lines across a single particle on the elemental maps confirmed that carbonaceous materials only existed on the surface and they were most likely carboxylates that increased with increased He/CO treatment duration, as evident by FTIR results. Finally, this work demonstrated the success of atmospheric plasma-treated reactive nAl with comprehensively characterized surface features via advanced microscopy and spectroscopy.

36 MATERIALS SCIENCE↗

Novel Supercritical Carbon Dioxide Power Cycle Utilizing Pressured Oxy-combustion in Conjunction with Cryogenic Compression

The team of Southwest Research Institute ® (SwRI) and Thar Energy LLC (Thar) applied technology engineering and economic analysis to evaluate two advanced oxy-combustion power cycles, the Cryogenic Pressurized Oxy-combustion Cycle (CPOC), and the Supercritical Oxy-combustion Cycle. This assessment evaluated the performance and economic cost of the two proposed cycles with carbon capture and included a technology gap analysis of the proposed technologies to determine the technology readiness level of the cycle and the cycle components. The results of the engineering and economic analysis and the technology gap analysis were used to identify the next steps along the technology development roadmap for the selected cycle. The project objectives, as outlined in the FOA, were 90% CO 2 removal at no more than a 35% increase in cost of electricity (COE) as compared to a Supercritical Pulverized Coal Plant without CO 2 capture. The supercritical oxy-combustion power cycle with 99% carbon capture achieves a COE of $\$$121/MWe. This revised COE represents a 21% reduction in cost as compared to supercritical steam with 90% carbon capture ($\$$137/MWe). However, this represents a 49% increase in the COE over supercritical steam without carbon capture ($\$$80.95/MWe), exceeding the 35% target. The supercritical oxy-combustion cycle with 99% carbon capture achieved a 37.9% HHV plant efficiency (39.3% LHV plant efficiency), when coupling a supercritical oxy-combustion thermal loop to an indirect supercritical CO 2 (sCO 2 ) power block. In this configuration, the power block achieved 48% thermal efficiency for turbine inlet conditions of 650°C and 290 atm. Power block efficiencies near 60% are feasible with higher turbine inlet temperatures, however a design tradeoff to limit firing temperature to 650°C was made in order to use austenitic stainless steels for the high temperature pressure vessels and piping and to minimize the need for advanced turbomachinery features such as blade cooling. The overall technical readiness of the supercritical oxy-combustion cycle is TRL 2, Technology Concept, due to the maturity level of the supercritical oxy-combustor for solid fuels, and several critical supporting components, as identified in the Technical Gap Analysis. The supercritical oxycombustor for solid fuels operating at pressures near 100 atm is a unique component of the supercritical oxy-combustion cycle. In addition to the low TRL supercritical oxy-combustor, secondary systems were identified that would require adaptation for use with the supercritical oxycombustion cycle. These secondary systems include the high pressure pulverized coal feed, high temperature cyclone, removal of post-combustion particulates from the high pressure cyclone underflow stream, and micro-channel heat exchangers tolerant of particulate loading. Bench scale testing was utilized to measure coal combustion properties at elevated pressures in a CO 2 environment. This testing included coal slurry preparation, visualization of coal injection into a high pressure fluid, and modification of existing test equipment to facilitate the combustion properties testing. Additional bench scale testing evaluated the effectiveness of a rotary atomizer for injecting a coal-water slurry into a fluid with similar densities, as opposed to the typical application where the high density fluid is injected into a low density fluid. The swirl type supercritical oxy-combustor was developed from initial concept to an advanced design stage through numerical simulation using FLUENT and Chemkin to model the flow through the combustor and provide initial assessment of the coal combustion reactions in the flow path. This effort enabled the initial combustor mechanical layout, initial pressure vessel design, and the conceptual layout of a pilot scale test loop. A pilot scale demonstration of the supercritical oxy-combustion cycle is proposed as the next step in the technology development. This demonstration would advance the supercritical oxy-combustion cycle and the supercritical oxy-combustor from a current TRL of 2, Technology Concept, to TRL 6, Pilot Scale System Demonstrated in a Relevant Environment, and enable the evaluation and continued refinement of the supercritical oxy-combustor and critical secondary systems.

42 ENGINEERING↗

Developing an ELM Ecosystem Dynamics Model on GPU with OpenACC

Porting a complex scientific code, such as the E3SM land model (ELM), onto a new computing architecture is challenging. The paper presents design strategies and technical approaches to develop an ELM ecosystem dynamics model with compiler directives (OpenACC) on NVIDIA GPUs. The code has been refactored with advanced OpenACC features (such as deepcopy and routine directives) to reduce memory consumption and to increase the levels of parallelism through parallel loop reconstruction and new data structures. As a result, the optimized parallel implementation achieved more than a 140-time speedup (50 ms vs 7600 ms), compared to a naive implementation that uses OpenACC routine directive and parallelizes the code across existing loops on a single NVIDIA V100. On a fully loaded computing node with 44 CPUs and 6 GPUs, the code achieved over a 3.0-times speedup, compared to the original code on the CPU. Furthermore, the memory footprint of the optimized parallel implementation is 300 MB, which is around 15% of the 2.15 GB of memory consumed by a naive implementation. This study is the first effort to develop the ELM component on GPUs efficiently to support ultra-high-resolution land simulations at continental scales.

Schwartz, Peter↗

OpenEdge: A collaborative, open-source, multi-purpose direct simulation Monte Carlo for plasma simulation in magnetic fusion environments

OpenEdge is a collaborative, open-source, object-oriented Direct Simulation Monte Carlo (DSMC) code, designed specifically for plasma simulations in magnetic fusion environments. Here, the code features include advanced structures, robust capabilities, and an effective parallelization strategy, all of which significantly enhance performance. It includes specialized modules for managing complex particle interactions, including collisions, ionization/recombination, and reflection/sputtering. Benchmarks and performance analyses have confirmed its efficiency and scalability. Versatile and adaptable, OpenEdge is applied across a broad spectrum of plasma-material interaction studies and charged particle transport in various fusion research settings.

Boundary plasma↗

Assessment of CASL VERA for BWR analysis and application to accident tolerant SiC/SiC channel box

Application of the Virtual Environment for Reactor Applications (VERA) to BWR analysis is assessed in this paper by comparing results to those calculated using other widely-used modeling tools, namely the U.S. Nuclear Regulatory Commission’s PARCS/PATHS and the Serpent Monte Carlo particle transport code. Additionally, VERA is used to calculate 3-D temperature and fast neutron flux distributions in silicon carbide (SiC) fiber-reinforced, SiC matrix composite (SiC/SiC) BWR channel boxes, which are being studied as an Accident Tolerant Fuel core structural material concept. We found that the code-to-code comparisons were favorable, and the SiC/SiC channel box evaluation demonstrates the many advanced modeling features VERA provides while also highlighting the non-uniformity in fast neutron flux distributions that can play a role in potential SiC/SiC channel box deformation. Traditional BWR analysis tools do not have the calculation fidelity necessary for coupled assessment of flux and temperature gradients in a SiC/SiC channel box. VERA is a state-of-the-art modeling environment that was developed to increase the safety and economic competitiveness of nuclear power through improved modeling accuracy. While VERA has already been deployed in the nuclear industry for PWR applications, the current study is a vital initial step in the extensive development, validation, and verification that VERA must go through to be useful for BWR applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Overexpressed ACBD3 has prognostic value in human breast cancer and promotes the self-renewal potential of breast cancer cells by activating the Wnt/beta-catenin signaling pathway

Highlights: • Up-regulated ACBD3 is associated with clinicopathological featuresin breast cancer. • ACBD3 regulates the enrichment of BCSCs via Wnt/beta-catenin pathway. • ACBD3 may represent candidate therapeutic targets to enable the elimination of BCSCs. Acyl-CoA binding domain containing 3 (ACBD3) is involved in the maintenance of Golgi structure and function through its interaction with the integral membrane protein. However, the clinical significance and biological role of ACBD3 in breast cancer remain unclear. Herein, we found that the mRNA and protein levels of ACBD3 were markedly up-regulated in breast cancer cells and tissues. Immunohistochemical analysis of breast cancer tissues demonstrated that ACBD3 overexpression was significantly associated with advanced clinicopathological features. Univariate and multivariate analysis indicated that ACBD3 overexpression correlates with poor prognosis in breast cancer. Furthermore, overexpressing ACBD3 promoted, while silencing ACBD3 inhibited, self-renewal and tumorigenesis in breast cancer cells in vitro and in vivo respectively. Importantly, upregulating ACBD3 promoted the self-renewal and tumorigenesis of breast cancer cells via activating the Wnt/beta-catenin signaling, and the pro-self-renewal effect of ACBD3 in breast cancer was antagonized by the Wnt signaling inhibitor TCF4-siRNA and Lef1-siRNA.These findings indicate that ACBD3 may represent candidate therapeutic targets to enable the elimination of breast cancer stem cells, providing the preclinical proof-of-concept for the prevention and treatment of breast cancer.

60 APPLIED LIFE SCIENCES↗

Decoding defect statistics from diffractograms via machine learning

Abstract Diffraction techniques can powerfully and nondestructively probe materials while maintaining high resolution in both space and time. Unfortunately, these characterizations have been limited and sometimes even erroneous due to the difficulty of decoding the desired material information from features of the diffractograms. Currently, these features are identified non-comprehensively via human intuition, so the resulting models can only predict a subset of the available structural information. In the present work we show (i) how to compute machine-identified features that fully summarize a diffractogram and (ii) how to employ machine learning to reliably connect these features to an expanded set of structural statistics. To exemplify this framework, we assessed virtual electron diffractograms generated from atomistic simulations of irradiated copper. When based on machine-identified features rather than human-identified features, our machine-learning model not only predicted one-point statistics (i.e. density) but also a two-point statistic (i.e. spatial distribution) of the defect population. Hence, this work demonstrates that machine-learning models that input machine-identified features significantly advance the state of the art for accurately and robustly decoding diffractograms.

36 MATERIALS SCIENCE↗

Reply to: Reconsidering X-ray plasmons

In this response we show a spectral and X-ray intensity analysis that unequivocally proves a spectrally resolved plasmon reported in ref. 1. The analysis takes the f-sum rules into account, is consistent with the independently and simultaneously measured wavenumber-resolved X-ray scattering signal and compares well with advanced elastic feature modelling, including density functional theory for molecular dynamics (DFTMD) as well as pseudoatom molecular dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New customizable phased array UT instrument opens door for furthering research and better industrial implementation

Phased array UT as an inspection technique in itself continues to gain wide acceptance. However, there is much room for improvement in terms of implementation of Phased Array (PA) technology for every unique NDT application across several industries (e.g. oil and petroleum, nuclear and power generation, steel manufacturing, etc.). Having full control of the phased array instrument and customizing a software solution is necessary for more seamless and efficient inspections, from setting the PA parameters, collecting data and reporting, to the final analysis. NDT researchers and academics also need a flexible and open platform to be able to control various aspects of the phased array process. A high performance instrument with advanced PA features, faster data rates, a smaller form factor, and capability to adapt to specific applications, will be discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optical activity of chirally distorted nanocrystals

We develop a general theory of optical activity of semiconductor nanocrystals whose chirality is induced by a small perturbation of their otherwise achiral electronic subsystems. The optical activity is described using the quantum-mechanical expressions for the rotatory strengths and dissymmetry factors introduced by Rosenfeld. We show that the rotatory strengths of optically active transitions are decomposed on electric dipole and magnetic dipole contributions, which correspond to the electric dipole and magnetic dipole transitions between the unperturbed quantum states. Remarkably, while the two kinds of rotatory strengths are of the same order of magnitude, the corresponding dissymmetry factors can differ by a factor of 10{sup 5}. By maximizing the dissymmetry of magnetic dipole absorption one can significantly enhance the enantioselectivity in the interaction of semiconductor nanocrystals with circularly polarized light. This feature may advance chiral and analytical methods, which will benefit biophysics, chemistry, and pharmaceutical science. The developed theory is illustrated by an example of intraband transitions inside a semiconductor nanocuboid, whose rotatory strengths and dissymmetry factors are calculated analytically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗